<channel>
	<title>Air Quality Meter - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/air-quality-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/air-quality-meter/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Thu, 23 Oct 2025 04:36:22 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Air Quality Meter - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/air-quality-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Air Quality Meter PCE-EM 880</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-pce-em-880/</link>
					<comments>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-pce-em-880/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Dec 2022 04:07:47 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=24859</guid>

					<description><![CDATA[<p>Air quality meter with data memory / Export of the save [...]</p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-pce-em-880/">Air Quality Meter PCE-EM 880</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Air quality meter with data memory / Export of the saved measurement data as CSV /</strong><br />
<strong>HCHO / TVOC / temperature / humidity / measuring range 0.00 &#8230; 9.99 mg/m³ /</strong><br />
<strong>1500 mAh battery / Mobile and stationary use / Micro USB interface</strong></div>
<p>&nbsp;</p>
<div align="justify">
<p>The air quality meter is equipped with various sensors to determine HCHO, TVOC, ambient temperature and ambient humidity. This means that the air quality meter already covers a wide range of measurement tasks. The measuring range for the TVOC measurement is 0.00 … 9.99 mg/m³. With an accuracy of ±5% of the measuring range for HCHO and TVOC measurement, the air quality meter is the ideal measuring tool for indicative measurements.</p>
<p>Thanks to the built-in 1500 mAh battery, it is possible to operate the air quality meter as a mobile device. As soon as the battery is discharged, it can be recharged via the micro USB interface with a 5 V DC power supply.</p>
<p>The air quality meter is therefore used, for example, to check the air quality in offices, workshops, school facilities or in logistics to check the premises for volatile organic substances and formaldehyde.</p>
<p>The readings are stored directly on the air quality meter. A memory with 5000 measuring points is available for the air quality meter. After a measurement, the readings can be analyzed on the air quality meter. In addition, the readings from the air quality meter can be transferred to a PC. When connecting the air quality meter to a PC, the air quality meter is recognized as a mass data storage device. This has the particular advantage that the air quality meter works independently of the operating system. The measured values ​​are saved in CSV file format by the air quality meter.</p>
</div>
<p>&#8211; Memory for 5000 measuring points<br />
&#8211; Measuring range 0.00 &#8230; 9.99 mg/m³ (TVOC)<br />
&#8211; Easy operation by virtual keys<br />
&#8211; Battery and mains operation<br />
&#8211; Tripod mount for stationary use<br />
&#8211; Individually adjustable alarm limits</p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-pce-em-880/">Air Quality Meter PCE-EM 880</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-pce-em-880/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">24859</post-id>	</item>
		<item>
		<title>Air Quality Formaldehyde Gas Meter HFX205</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-formaldehyde-gas-meter-hfx205/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:37:20 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10004</guid>

					<description><![CDATA[<p><strong>HFX205</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-formaldehyde-gas-meter-hfx205/">Air Quality Formaldehyde Gas Meter HFX205</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p><strong>Professional formaldehyde Air Quality Meter to measure air after the evaporation of wooden material, flooring, furniture, textiles… / Alarm signal exceeding of limit / USB-interface</strong></p>
<p>This Air Quality Meter is designed to detect formaldehyde in air. The Air Quality Meter shows the formaldehyde-concentration on site and thereby avoids time-consuming and expensive analysis in laboratories. The formaldehyde Air Quality Meter runs with help of an electro-mechanical sensor and is designed to determine the current permitted limit. A measurement can be accomplished in less than 30 seconds. The concentration is measured in ppm units. Some substances such as ethanol, propanol or methanol can interfere with the measuring data. An optionally purchasable hygrometer-sensor allows for a correction of the measured data in order to achieve accurate measurements. The Air Quality Meter can be connected to a computer or laptop by means of the USB-Interface, thereby allowing an automatic and continuous measuring over a long period of time. Time and battery status are shown continuously on a display. Information on all the gass-measuring devices of PCE Instruments is shown below. For further information, please feel free to read the following technical data. Our engineers and technicians will gladly advise you on the measuring device for formaldehyde concentration or any other product in terms of regulation and control, or scales and balances of PCE Instruments.</p>
</div>
<div>
<div>&#8211; <span lang="EN-GB">Short reaction time</span><br />
&#8211; <span lang="EN-GB">Real-time display<br />
&#8211; </span><span lang="EN-GB">Manual and auto data storage</span><br />
&#8211; High-speed USB<br />
&#8211; Software for Online Data transfer</div>
<div>&#8211; <span lang="EN-GB">No warm-up time necessary</span><br />
&#8211; Automatic background lightening<span lang="EN-GB"><br />
&#8211; Self-calibration</span><span lang="EN-GB"><br />
</span><span lang="EN-US">&#8211; </span><span lang="EN-GB">Alarm signal if level of limit is reached<br />
&#8211; Operating time up to 6 hrs</span></div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><span lang="EN-US"><strong>Technical data of Formaldehyde </strong></span><strong>Air Quality Meter<br />
</strong></td>
</tr>
<tr>
<td>Measuring range</td>
<td>0…10 ppm</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01 ppm</td>
</tr>
<tr>
<td>Accuracy</td>
<td>&lt; ± 2%</td>
</tr>
<tr>
<td>Reaction time</td>
<td>&lt; 30 seconds</td>
</tr>
<tr>
<td>Data storage</td>
<td>Up to 500 datasets</td>
</tr>
<tr>
<td>Operation temperature</td>
<td>5 &#8230; 40°C / 41 &#8230; 104°F</td>
</tr>
<tr>
<td>Power Supply</td>
<td>Li-ion battery (3.7 V/1200-mAh)<br />
AC-adapter 100 &#8230; 240V to 5 VDC / 1 A</td>
</tr>
<tr>
<td>Operation time</td>
<td>6 hrs. with batteries</td>
</tr>
<tr>
<td>Dimensions</td>
<td>80 x 36 x 150 mm / 3.1 x 1.4 x 5.9 in</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 200g / 7.9 lb</td>
</tr>
<tr>
<td colspan="2"><strong><br />
Formaldehyde<br />
</strong></td>
</tr>
<tr>
<td colspan="2">Formaldehyde is a colourless, pungent-smelling substance, which is gaseous at room temperature.An improper use can result in allergies, skin and respiratory diseases or eye irritation. It is classified as carcinogenic. In areas of textiles, the voluntary measurement of limits for harmful substances is awarded a seal of approval (e.g. Toxproof or Öko-Tex 100) is by 20 mg/kg (20ppm). In addition, formaldehyde can especially be found in the following materials: wooden materials, furniture, chip boards and groundings.</td>
</tr>
<tr>
<td colspan="2"><strong>Interference with measuring rate of formaldehyde<br />
</strong></td>
</tr>
<tr>
<td>Chemical</td>
<td>Formaldehyde equivalent</td>
</tr>
<tr>
<td>100 ppm methanol</td>
<td>1 ppm</td>
</tr>
<tr>
<td>100 ppm ethanol</td>
<td>1 ppm</td>
</tr>
<tr>
<td>100 ppm isopropanol</td>
<td>0.5 ppm</td>
</tr>
<tr>
<td>100 ppm CO</td>
<td>1 ppm</td>
</tr>
<tr>
<td>25 ppm phenol</td>
<td>0.05 ppm</td>
</tr>
<tr>
<td>100 ppm acetaldehyde</td>
<td>0.5 ppm</td>
</tr>
<tr>
<td>100 ppm hydrogen</td>
<td>3 ppm</td>
</tr>
<tr>
<td>50 ppm hydrogen sulphide</td>
<td>0.5 ppm</td>
</tr>
<tr>
<td>50 ppm sulphur dioxide</td>
<td>0.5 ppm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-formaldehyde-gas-meter-hfx205/">Air Quality Formaldehyde Gas Meter HFX205</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10004</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-PH3 &#8220;Phosphine&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-ph3-phosphine/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:29:03 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10001</guid>

					<description><![CDATA[<p>Gasman-PH3 Unique Air Quality Meter personal protection [...]</p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-ph3-phosphine/">Air Quality Meter Gasman-PH3 &#8220;Phosphine&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-PH3 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO. In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors.</p>
<p align="justify">In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5% v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">Minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; Interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20°C &#8230; +55°C / -4°F &#8230; +131°F<br />
0 &#8230; 99 % R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">Max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C / -4°F &#8230; +131°F)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-ph3-phosphine/">Air Quality Meter Gasman-PH3 &#8220;Phosphine&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10001</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-O3 &#8220;Ozone&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-o3-ozone/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:24:03 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9999</guid>

					<description><![CDATA[<p><strong>Gasman-O3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-o3-ozone/">Air Quality Meter Gasman-O3 &#8220;Ozone&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-O3 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO. In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors.</p>
<p align="justify">In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5% v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">Minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; Interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20°C &#8230; +55°C / -4°F &#8230; +131°F<br />
0 &#8230; 99 % R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55°C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-o3-ozone/">Air Quality Meter Gasman-O3 &#8220;Ozone&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9999</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-CO2 &#8220;Carbon Dioxide&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-co2-carbon-dioxide/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:21:49 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9996</guid>

					<description><![CDATA[<p><strong>Gasman-CO2-A</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-co2-carbon-dioxide/">Air Quality Meter Gasman-CO2 &#8220;Carbon Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-CO2 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO.</p>
<p align="justify">In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors. In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100 % LEL</td>
<td align="center">20 % LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25 % v/v</td>
<td align="center">19 % and 23 % v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5 % v/v</td>
<td align="center">0.5 and 1.5 % v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20° C &#8230; +55° C / -4° F &#8230; +131° F<br />
0 &#8230; 99 % R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-co2-carbon-dioxide/">Air Quality Meter Gasman-CO2 &#8220;Carbon Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9996</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-NO2 &#8220;Nitrogen Dioxide&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-no2-nitrogen-dioxide/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:19:07 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9992</guid>

					<description><![CDATA[<p><strong>Gasman-NO2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-no2-nitrogen-dioxide/">Air Quality Meter Gasman-NO2 &#8220;Nitrogen Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-NO2 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO. In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors.</p>
<p align="justify">In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5% v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">Minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; Interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20°C &#8230; +55°C / -4°F &#8230; +131°F<br />
0 &#8230; 99% R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-no2-nitrogen-dioxide/">Air Quality Meter Gasman-NO2 &#8220;Nitrogen Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9992</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-H2 &#8220;Hydrogen&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-h2-hydrogen/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:13:53 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9986</guid>

					<description><![CDATA[<p><strong>Gasman-H2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-h2-hydrogen/">Air Quality Meter Gasman-H2 &#8220;Hydrogen&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-H2 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO.</p>
<p align="justify">In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors. In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5% v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20° C &#8230; +55° C / -4° F &#8230; +131° F<br />
0 &#8230; 99% R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-h2-hydrogen/">Air Quality Meter Gasman-H2 &#8220;Hydrogen&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9986</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-NH3 &#8220;Ammonia Gas&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-nh3-ammonia-gas/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 08:07:43 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9980</guid>

					<description><![CDATA[<p><strong>Gasman-NH3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-nh3-ammonia-gas/">Air Quality Meter Gasman-NH3 &#8220;Ammonia Gas&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-NH3 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO. In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors.</p>
<p align="justify">In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5 % v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">Minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; Interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20° C &#8230; +55° C / -4° F &#8230; +131° F<br />
0 &#8230; 99% R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">Max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-nh3-ammonia-gas/">Air Quality Meter Gasman-NH3 &#8220;Ammonia Gas&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9980</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-SO2 &#8220;Sulfur Dioxide&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-so2-sulfur-dioxide/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 07:57:38 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9975</guid>

					<description><![CDATA[<p><strong>Gasman-SO2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-so2-sulfur-dioxide/">Air Quality Meter Gasman-SO2 &#8220;Sulfur Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-SO2 Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, inflammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO.</p>
<p align="justify">In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors. In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for inflammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “inflammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Inflammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5 % v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20° C &#8230; +55° C / -4° F &#8230; +131° F<br />
0 &#8230; 99 % R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm /<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (inflammable gases)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-so2-sulfur-dioxide/">Air Quality Meter Gasman-SO2 &#8220;Sulfur Dioxide&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9975</post-id>	</item>
		<item>
		<title>Air Quality Meter Gasman-FL &#8220;Flammable Gases&#8221;</title>
		<link>https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-fl-flammable-gases/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 18 Jan 2021 07:54:04 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=9963</guid>

					<description><![CDATA[<p><strong>Gasman-FL</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-fl-flammable-gases/">Air Quality Meter Gasman-FL &#8220;Flammable Gases&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Gasman-FL Unique Air Quality Meter<br />
personal protection with datalogger / Optional software and data cable ATEX II 1G EEx ia IIC T4 / ATEX II 2G EEx ia d IIC T4 (EEx ia (d) IIC T3/T4)</strong></p>
<p align="justify">This Air Quality Meter is a unique gas meter which protects against a specific gas, flammable or toxic. The Air Quality Meter Gasman warns with a penetrating alarm and an optical signal (useful when there are loud noises in the surrounding area) of the existence of dangerous gas concentrations and shows on screen the value of the gas measurement. In addition with this gas meter you are able to save measurements and transmit them onto the computer for evaluation. For that, it is necessary to require the additional option of data logger and optional software. The function of logger will allow you to keep all the values in the meter with a quota of measurement from 1 minute to a total of 900 hours. The data saved in the apparatus can be, at any time, transferred onto the computer or laptop for later evaluation. The Air Quality Meter can be calibrated and certified according to DIN ISO.</p>
<p align="justify">In addition it is verified according to the most recent directives (94/9/EG) and disposition on the protection against explosions (ExVo). Every two years recalibrations can be made where you choose the sensor (according to the type of gas) with which the apparatus must be equipped. You will be able to choose between 12 standard sensors, but you can also request other types of special sensors. In addition to the traditional uses of the Air Quality Meter such as in industry, institutions and investigations, this gas meter is an economic alternative to be used by the fire brigades (with Ex- sensor for flammable gases). The Air Quality Meter fulfills all the European and international norms, even ATEX and UL standards. Another special use is the measurement of the ozone concentration, allowing this small Air Quality Meter to be complemented with an ozone sensor. You can send us the Air Quality Meter for maintenance and recalibration, taking into account the indications of the ISO manual of your company (for example, twice a year). The Air Quality Meter can be dismounted, cleaned, and recalibrated. If a sensor can no longer be calibrated or its period of validity has already expired, you will receive the corresponding information and spare sensors can be found in our online shop. You can request the optional software to set up, calibrate, and adjust the limits of the alarm and the function of the datalogger (also optional) to read the values saved in the Air Quality Meter. This software represents the data in the form of graphs or tables and it is also possible to export them to other programs.</p>
<p align="justify"><strong>Notice:</strong> The combined charging station serves as interface for the data transmission, the station is used to load the storage cells of the meter of gas for “flammable gases” + “oxygen” and of interface for the PC for the rest of the models.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify">
<ul>
<li>Free set up level alarm, vibratory alarm, LED alarm, beeper</li>
<li>Comfortable to use all day long</li>
<li>Internal security makes it possible to take it on Ex-zone</li>
<li>Loud sound</li>
<li>Robust housing</li>
<li>Dust and water resistant &#8211; IP 65/67</li>
</ul>
</td>
<td align="justify">
<ul>
<li>Can only be disconnected pressing two keys simultaneously</li>
<li>LCD with backlight</li>
<li>Internal calibration by means of the keyboard in the frontal part of the meter</li>
<li>Datalogger function</li>
<li>Optional software compatible with Windows to set up the meter in a fast and easy way to read the internal memory</li>
<li>Connection to PC takes place by means of the cable of the interface</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical specifications (12 gases choice)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="4" align="center">Typical measurement ranges and alarm adjustments</td>
</tr>
<tr>
<td align="center"><strong>Parameter/Gas</strong></td>
<td align="center"><strong>Symbol</strong></td>
<td align="center"><strong>Range</strong></td>
<td align="center"><strong>Alarm</strong></td>
</tr>
<tr>
<td align="center">Flammable gas</td>
<td align="center">CH4</td>
<td align="center">0 &#8230; 100% LEL</td>
<td align="center">20% LEL</td>
</tr>
<tr>
<td align="center">Oxygen</td>
<td align="center">O2</td>
<td align="center">0 &#8230; 25% v/v</td>
<td align="center">19% and 23% v/v</td>
</tr>
<tr>
<td align="center">Hydrogen sulfide</td>
<td align="center">H2S</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">5 ppm</td>
</tr>
<tr>
<td align="center">Carbon dioxide</td>
<td align="center">CO2</td>
<td align="center">0 &#8230; 5 % v/v</td>
<td align="center">0.5 and 1.5% v/v</td>
</tr>
<tr>
<td align="center">Carbon monoxide</td>
<td align="center">CO</td>
<td align="center">0 &#8230; 500 ppm</td>
<td align="center">30 ppm</td>
</tr>
<tr>
<td align="center">Sulfur dioxide</td>
<td align="center">SO2</td>
<td align="center">0 &#8230; 20 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Chlorine <strong>*</strong></td>
<td align="center">CL2</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Nitrogen dioxide<strong>*</strong></td>
<td align="center">NO2</td>
<td align="center">0 &#8230; 10 ppm</td>
<td align="center">1 ppm</td>
</tr>
<tr>
<td align="center">Phosphine</td>
<td align="center">PH3</td>
<td align="center">0 &#8230; 5 ppm</td>
<td align="center">0.5 ppm</td>
</tr>
<tr>
<td align="center">Ammonia</td>
<td align="center">NH3</td>
<td align="center">0 &#8230; 100 ppm</td>
<td align="center">25 ppm</td>
</tr>
<tr>
<td align="center">Hydrogen</td>
<td align="center">H2</td>
<td align="center">0 &#8230; 1000 ppm</td>
<td align="center">100 ppm</td>
</tr>
<tr>
<td align="center">Ozone</td>
<td align="center">O3</td>
<td align="center">0 &#8230; 1 ppm</td>
<td align="center">0.1 ppm</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>*</strong> With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.</td>
</tr>
<tr>
<td align="justify">Sensors (sensors are exchangeable)</td>
<td align="justify">Response time (T90)</td>
<td align="justify" width="30%">Life</td>
</tr>
<tr>
<td align="justify">Methane</td>
<td align="justify">20 s</td>
<td align="justify">5 years</td>
</tr>
<tr>
<td align="justify">Toxic gases</td>
<td align="justify">20 s</td>
<td align="j8stift">3 years</td>
</tr>
<tr>
<td align="justify">Oxygen</td>
<td align="justify">10 s</td>
<td align="justift">minimum 1 year</td>
</tr>
<tr>
<td align="justify">Acoustic alarms</td>
<td align="justify">&#8211; 85 dB (a) to 1 m of distance (adjustable tone)<br />
&#8211; Tone of regular control that can be disconnected<br />
&#8211; Prolonged tone in case of low battery in the gas meter</td>
</tr>
<tr>
<td align="justify">Optical alarm</td>
<td align="justify">&#8211; Very clear and flashing LED<br />
&#8211; Type of alarm Indicator<br />
&#8211; Green LED with low frequency flashing as operating indicator</td>
</tr>
<tr>
<td align="justify">Vibration alarm</td>
<td align="justify">&#8211; Meter vibrates additionally as a complement to the optical and acoustic alarms</td>
</tr>
<tr>
<td align="justify">Autozero function</td>
<td align="justify">&#8211; In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="justify">&#8211; LCD with backlight<br />
&#8211; 10 mm lines to indicate the gas value<br />
&#8211; Symbols for: Max Hold, Batt Low, calibration<br />
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA</td>
</tr>
<tr>
<td align="justify">Measurement values memory</td>
<td align="justify">Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="justify">Toxic gases and oxygen</td>
<td align="justify">&#8211; interchangeable lithium battery<br />
&#8211; 1 year in normal use conditions</td>
</tr>
<tr>
<td align="justify">in order to load, the charging station is necessary</td>
<td align="justify">&#8211; 2 cells of nickel-metal hydride (reloadable), 8 &#8230; 10 hours of operative duration</td>
</tr>
<tr>
<td align="justify">Environmental conditions</td>
<td align="justify">-20° C &#8230; +55° C / -4° F &#8230; +131° F<br />
0 &#8230; 99 % R.H. non condensed</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td align="justify">IP 65/67</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td align="justify">90 mm x 48 mm x 24 mm<br />
3.5 in x 1.9 in x 0.94 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="justify">max. 130 g / 0.29 lbs (battery included)</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="justify">EN 50014, EN 50020, EN 50018, EN 55022<br />
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721</td>
</tr>
<tr>
<td align="justify">Authorisation</td>
<td align="justify">EEx ia (d) IIC T3 or T4<br />
ATEX II 1G EEx ia IIC T4 (-20 &#8230; +55 °C)<br />
(Toxic gases and oxygen)<br />
ATEX II 2G EEx ia d IIC T4 (flammable gases)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/air-quality-meter/air-quality-meter-gasman-fl-flammable-gases/">Air Quality Meter Gasman-FL &#8220;Flammable Gases&#8221;</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>