<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Current Calibrator - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/calibrator-เครื่องสอบเทียบ/current-calibrator/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 29 Nov 2022 17:07:38 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Current Calibrator - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/calibrator-เครื่องสอบเทียบ/current-calibrator/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Current Calibrator PCE-789</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-789/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 07:29:50 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11234</guid>

					<description><![CDATA[<p><strong>PCE-789</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-789/">Current Calibrator PCE-789</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>Current Calibrator PCE-789 measures and simulates current and voltage signals and </strong><strong>thermocouples / integrates a function generator for specific waveforms / </strong><strong style="font-size: 14.4px;line-height: 1.4em">large graphical display with backlight / </strong><strong style="font-size: 14.4px;line-height: 1.4em">data logger function</strong></div>
<div></div>
</div>
<div>The Current Calibrator PCE-789 is a versatile instrument for measuring and simulating process signals. The Current Calibrator measures and simulates current and voltage signals. The curves of different types of thermocouples are stored on your computer, and because of this you can introduce and display the values in ° C. The main feature of this Current Calibrator is the integrated function generator. Apart from the waveforms of sine, triangle, rectangle and cut sane, the Current Calibrator has saved inside other 10 sinusoidal waveforms. Using the software, which is included in the delivery, you can create specific waveforms and store them on the Current Calibrator. Furthermore, this Current Calibrator can give two overlapping frequencies. For its functionality combined with a robust plastic housing, the Current Calibrator can be used in many sareas . This Current Calibrator is a useful tool with which you can perform many tasks in areas such as maintenance in the industry, and it can be used by engineers and laboratory technicians in the service sector. This system is supplied by mains adapter and battery allowing mobile use.</div>
<div></div>
<div>
<div>&#8211; Different signals simulation and measurement<br />
&#8211; Integrated function generator<br />
&#8211; Graphic display with backlight</div>
<div>&#8211; Battery powered<br />
&#8211; Own waveforms simulation<br />
&#8211; Data logging function</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical Specifications</strong></td>
</tr>
<tr>
<td colspan="2">
<table>
<tbody>
<tr>
<td>Magnitud</td>
<td>
<p align="center">Range</p>
</td>
<td>
<p align="center">Resolution</p>
</td>
<td>
<p align="center">Accuracy</p>
</td>
</tr>
<tr>
<td colspan="4">
<p align="center">Generate / Simulate</p>
</td>
</tr>
<tr>
<td rowspan="4">Current<br />
(no charge voltage &gt;15 V)</td>
<td align="center">-4 &#8230; -0,005 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">0,005 &#8230; 4 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">4 &#8230; 20 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 53gits )</td>
</tr>
<tr>
<td align="center">20 &#8230; 24 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td rowspan="4">Voltage<br />
(máa 1 mA)</td>
<td align="center">-3 &#8230; -0,005 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">0,005 V &#8230; 10 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">10 V &#8230; 15 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">-10 &#8230; 70 mV</td>
<td align="center">0,01 mV</td>
<td align="center">0,05 mV</td>
</tr>
<tr>
<td>Termocouples<br />
Types: K, J, E, T, R, S, N, L, U, B, C</td>
<td align="center">according to type<br />
(see use intructions)</td>
<td align="center">0,1 °C</td>
<td align="center">according to type<br />
(see use intructions)</td>
</tr>
<tr>
<td rowspan="4">Frequency</td>
<td align="center">0,3 &#8230; 99,999 Hz</td>
<td align="center">0,1 Hz</td>
<td align="center">0,002 Hz</td>
</tr>
<tr>
<td align="center">10,00 &#8230; 999,99 Hz</td>
<td align="center">0,1 Hz</td>
<td align="center">0,02 Hz</td>
</tr>
<tr>
<td align="center">1000,0 &#8230; 9999,9 Hz</td>
<td align="center">0,1 Hz</td>
<td align="center">0,2 Hz</td>
</tr>
<tr>
<td align="center">10000 &#8230; 20000 Hz</td>
<td align="center">0,1 Hz</td>
<td align="center">2 Hz</td>
</tr>
<tr>
<td colspan="4" align="center">Mesurement</td>
</tr>
<tr>
<td rowspan="4">Current</td>
<td align="center">-4 &#8230; -0,005 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">0,005 &#8230; 4 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">4 &#8230; 20 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 53gits )</td>
</tr>
<tr>
<td align="center">20 &#8230; 24 mA</td>
<td align="center">1 µA</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td rowspan="3">Voltage</td>
<td align="center">-3 &#8230; 0,005 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">0,005 V &#8230; 10 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td align="center">10 V &#8230; 15 V</td>
<td align="center">1 mV</td>
<td align="center">± (0,03 % + 5 digits )</td>
</tr>
<tr>
<td>Termocouples<br />
Types: K, J, E, T, R, S, N, L, U, B, C</td>
<td align="center">according to type<br />
(see use intructions)</td>
<td align="center">0,1 °C</td>
<td align="center">according to type<br />
(see use intructions)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2">General observations</td>
</tr>
<tr>
<td>Power supply</td>
<td>internal acumulator o mains adapter</td>
</tr>
<tr>
<td>Dimensions</td>
<td>214,0 x 98,7 x 56,0 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>650 g</td>
</tr>
<tr>
<td>Environmental conditions</td>
<td>Operating: 0 &#8230; 50 °C, 85 % R.H..<br />
Stored: -20 &#8230; 60 °C, 75 %  R.H..</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-789/">Current Calibrator PCE-789</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11234</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-RTD 20</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-rtd-20/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 07:24:55 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11232</guid>

					<description><![CDATA[<p><strong>PCE-RTD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-rtd-20/">Current Calibrator PCE-RTD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>PCE-RTD 20 RTD Current calibrator</strong><strong><br />
Simulation and Measurement of Resistance &amp; Pt Sensors, Current and Voltage / Li-Ion Battery / Continuity Checker / Ramp Function</strong></div>
<div></div>
<div>The RTD current calibrator PCE-RTD 20 is used to simulate resistors and resistance temperature sensors. Thus, the RTD current calibrator is able to be used as a calibrator for temperature measuring devices. In addition to the simulation of resistors, the RTD current calibrator has a measuring function for voltage, current and resistance. Both functions work independently. Furthermore, both connections are galvanically separated from each other.</div>
<div></div>
<div>The RTD current calibrator has many different characteristics for RTD sensors, so that a perfect calibration of thermometers of various kinds is possible. The RTD current calibrator has an accuracy of 0.02% in all measurement ranges and measurement functions. In addition to the direct specification of temperatures or resistances, the RTD current calibrator can be operated in ramp mode. Here, the user can decide whether the ramp should be run indefinitely or at defined intervals.</div>
<div></div>
<div>The PCE-RTD 20 RTD current calibrator is equipped with a mini-USB interface. This jack can be used to load the RTD current calibrator. Furthermore, recorded data can be transmitted via this interface.</div>
<div></div>
<div>&#8211; Simulation and measurement mode<br />
&#8211; Battery operation<br />
&#8211; Graphic LCD<br />
&#8211; 24V supply for current loops<br />
&#8211; HART compatible<br />
&#8211; Manual mode &amp; ramp function<br />
&#8211; Continuity test<br />
&#8211; Data logger function</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="276"><strong><span>Measuring range</span></strong></td>
<td valign="top" width="152"><strong><span>Resolution</span></strong></td>
<td valign="top" width="195"><strong><span>Accuracy (</span></strong><strong><span>of rdg.)</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring parameter voltage DC V</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 30V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.02% </span><span>of rdg. + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring parameter current DC mA</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 24-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± 0.02% </span><span>of rdg. + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Measurement parameter resistance</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 400 Ω</span></td>
<td valign="top"><span>0.01 Ω</span></td>
<td valign="top"><span>± 0.02% </span><span>of rdg. + 0.01Ω</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Pt10 &#8230; Pt1000</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-200 &#8230; 200°C / -328 &#8230; 392</span>°F</td>
<td valign="top"><span>Pt10 &#8230; Pt400: 0.01°C / 0.018</span>°F</td>
<td valign="top"><span>± 0.2°C / 0.36</span>°F</td>
</tr>
<tr>
<td valign="top"><span>200 &#8230; 600°C / 392 &#8230; 1112</span>°F</td>
<td valign="top"><span>Pt500 &#8230; Pt100: 0.1°C / 0.18</span>°F</td>
<td valign="top"><span>± 0.3°C / 0.54</span>°F</td>
</tr>
<tr>
<td valign="top"><span>600 &#8230; 850°C / 1112 &#8230; 1562</span>°F</td>
<td valign="top"></td>
<td valign="top"><span>± 0.1°C / 0.18</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Ni100</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-60 &#8230; 180°C / -76 &#8230; 356</span>°F</td>
<td valign="top"><span>0.01°C</span><span> / 0.018</span>°F</td>
<td valign="top"><span>± 0.1°C / 0.18</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Ni120</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-80 &#8230; 260°C / &#8211; 112 &#8230; 500</span>°F</td>
<td valign="top"></td>
<td valign="top"><span>± 0.1°C / 0.18</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Cu10</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-200 &#8230; 260°C / -328 &#8230; 500</span>°F</td>
<td valign="top"></td>
<td valign="top"><span>± 0.2°C / 0.36</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>*In 4-wire measuring mode, a resolution of up to 0.01 Ω in the range 0 &#8230; 1600 Ω is possible. The specified accuracy applies to the 4-wire measuring mode. With 3-wire measurement, measurement inaccuracy increases by 1°C / 1.8°F (Pt10 / Cu10), 0.6°C / 1.08°F (Pt50 / Cu50) and 0.4°C / 0.72°F (remaining types).</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong><span><strong>* </strong></span></td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation parameter resistance</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 400 Ω</span></td>
<td valign="top"><span>0.01 Ω</span></td>
<td valign="top"><span>± 0.02% </span><span>of rdg. + 0.01Ω</span></td>
</tr>
<tr>
<td valign="top"><span>400 &#8230; 4000 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>± 0.02% </span><span>of rdg. + 0.015Ω</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation parameters Pt10 &#8230; Pt1000</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-200 &#8230; 200°C</span><span> / -328 &#8230; 392</span>°F</td>
<td valign="top"><span>Pt10 &#8230; Pt400: 0.01 </span></td>
<td valign="top"><span>± 0.15°C / 0.27</span>°F</td>
</tr>
<tr>
<td valign="top"><span>200 &#8230; 600°C</span><span> / 392 &#8230; 1112</span>°F</td>
<td valign="top"><span>Pt500 &#8230; Pt100: 0.1 </span></td>
<td valign="top"><span>± 0.25°C / 0.45</span>°F</td>
</tr>
<tr>
<td valign="top"><span>600 &#8230; 850°C</span><span> / 1112 &#8230; 1562</span>°F</td>
<td valign="top"></td>
<td valign="top"><span>± 0.15°C</span><span> / 0.27</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation parameter Ni100</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-60 &#8230; 180°C</span></td>
<td valign="top"><span>0.01°C / 0.018</span>°F</td>
<td valign="top"><span>± 0.15°C</span><span> / 0.27</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation </span></strong><strong><span>parameter Ni120</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-80 &#8230; 260°C</span></td>
<td valign="top"><span>0.01°C</span><span> / 0.018</span>°F</td>
<td valign="top"><span>± 0.15°C</span><span> / 0.27</span>°F</td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation </span></strong><strong><span>parameter Cu10</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-200 &#8230; 260°C</span></td>
<td valign="top"><span>0.01°C</span><span> / 0.018</span>°F</td>
<td valign="top"><span>± 0.8°C / 1.4</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>*Accuracy is valid at a current of&gt; 0.2-mA or&gt; 0.4-mA.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Compatible RTD sensor</span></td>
<td colspan="2" valign="top"><span>Pt10 (385), Pt50 (385), Pt100 (385), Pt200 (385), Pt400 (385), Pt500 (385), Pt1000 (385), Pt10 (3926)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Ni100 (672), Ni (618), Ni120 (672), Cu10 (427), Cu50 (427), Cu100 (427)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>General Specifications PCE-RTD 20</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Display modes</span></td>
<td colspan="2" valign="top"><span>Measurement: mA / V / Ω / RTD </span><br />
<span>Simulation: Ω / RTD</span></td>
</tr>
<tr>
<td valign="top"><span>Temperature units</span></td>
<td colspan="2" valign="top"><span>° C / ° F / K</span></td>
</tr>
<tr>
<td valign="top"><span>Current of RTD measurement</span></td>
<td colspan="2" valign="top"><span>About 300 μA</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum current simulation</span></td>
<td colspan="2" valign="top"><span>3-mA (0 &#8230; 650 Ω) </span><br />
<span>I &lt; 2V / Rsim (650 &#8230; 4000 Ω)</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum input voltage</span></td>
<td colspan="2" valign="top"><span>30V DC</span></td>
</tr>
<tr>
<td valign="top"><span>Temperature coefficient</span></td>
<td colspan="2" valign="top"><span>&lt;30 ppm</span></td>
</tr>
<tr>
<td valign="top"><span>Input impedance</span></td>
<td colspan="2" valign="top"><span>Voltage measurement:&gt; 1 MΩ </span><br />
<span>Current measurement: 10 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Response time</span></td>
<td colspan="2" valign="top"><span>&lt;100 ms</span></td>
</tr>
<tr>
<td valign="top"><span>Refresh rate display</span></td>
<td colspan="2" valign="top"><span>10 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="2" valign="top"><span>Internal memory  </span><br />
<span>150000 readings</span></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="2" valign="top"><span>USB 2.0</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>2.4&#8243; TFT LCD </span><br />
<span>240 x 320 pixels </span><br />
<span>LED illuminated</span></td>
</tr>
<tr>
<td valign="top"><span>Output voltage current loop</span></td>
<td colspan="2" valign="top"><span>24V DC / 24-mA</span></td>
</tr>
<tr>
<td valign="top"><span>HART mA loop resistance</span></td>
<td colspan="2" valign="top"><span>250 Ω ± 20%</span></td>
</tr>
<tr>
<td valign="top"><span>Special features</span></td>
<td colspan="2" valign="top"><span>Step and ramp function </span><br />
<span>Automatic and manual </span><br />
<span>mode √x, x2: For the measuring function</span></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td colspan="2" valign="top"><span>Adjustable threshold up to 100 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="2" valign="top"><span>3.7V / 2300-mAh Li-ion battery</span></td>
</tr>
<tr>
<td valign="top"><span>Charging time</span></td>
<td colspan="2" valign="top"><span>About 5 h</span></td>
</tr>
<tr>
<td valign="top"><span>Power adapter</span></td>
<td colspan="2" valign="top"><span>Input: 100 &#8230; 240V AC / 50/60 Hz </span><br />
<span>Output: 5V / 1 A DC</span></td>
</tr>
<tr>
<td valign="top"><span>Battery life</span></td>
<td colspan="2" valign="top"><span>Approx. 15 h: Simulation and measurement with low LCD illumination </span><br />
<span>Approx. 8 h: Measurement with low LCD illumination</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>162 x 82 x 40 mm / 6.4 x 3.2 x 1.6 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>About 300 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Degree of protection</span></td>
<td colspan="2" valign="top"><span>IP20</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="2" valign="top"><span>Battery operation: 0 &#8230; 55°C / 32 &#8230; 131°F, 30 &#8230; 90% RH Mains o</span><span>peration: 0 &#8230; 45°C / 32 &#8230; 113°F, 30 &#8230; 90% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="2" valign="top"><span>-20 .. 60°C / -4 &#8230; 140°F, 30 &#8230; 90% rh non-condensing</span></td>
</tr>
<tr>
<td valign="top"><span>Heating time</span></td>
<td colspan="2" valign="top"><span>About 15 minutes</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-rtd-20/">Current Calibrator PCE-RTD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11232</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-LOC 20</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-20/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 07:21:01 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11230</guid>

					<description><![CDATA[<p><strong>PCE-LOC 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-20/">Current Calibrator PCE-LOC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>PCE-LOC 20 Current calibrator<br />
For Simulation and Measurement of Current and Voltage / Li-Ion battery / Continuity tester / Ramp function / Data logger</strong></div>
<div></div>
<div>The current calibrator PCE-LOC 20 can be used to directly simulate process currents in current loop, mV and mA. This allows the current calibrator to be used to set process displays, data loggers, paperless recorders, etc. Thanks to the galvanically isolated connections, this current calibrator can simultaneously serve as a source and as a measuring device. Here, it does not matter whether currents are measured and voltages are simulated, since the functions work completely independently of each other.</div>
<div></div>
<div>The current calibrator PCE-LOC 20 has a high accuracy of 0.02% of the measured value in all operating modes. The current calibrator is powered by a rechargeable battery that can be charged via a USB power adapter. The memory can also be read out by the current calibrator via this interface. For ease of operation, the LCD contributes from the current calibrator.</div>
<div></div>
<div>In addition to the direct specification of the simulated parameters, the current calibrator has a ramp mode that allows the parameters to be changed incrementally and automatically over a defined period of time. The current calibrator PCE-LOC 20 can also specify the scaled process value. This means, for example, that a temperature in °C / °F is specified directly and the calibrator simulates the analog process value in mA.</div>
<div></div>
<div>&#8211; Simultaneous simulation and measurement mode<br />
&#8211; Battery operation<br />
&#8211; For mA, mV and V<br />
&#8211; Graphic display<br />
&#8211; Supply of sensors possible<br />
&#8211; Manual mode &amp; ramp function<br />
&#8211; Continuity test<br />
&#8211; Data logger function</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="265"><strong><span>Measurement parameter </span><br />
<span>Voltage mV</span></strong></td>
<td valign="top" width="131"></td>
<td valign="top" width="186"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 250 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage DC V</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 30V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current DC mA</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 24-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Simulation parameters</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage mV</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 250 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage DC V</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 12V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current DC mA</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 24-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± 0.02% of reading + 2 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>General Specifications PCE-LOC 20</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Display modes</span></td>
<td colspan="2" valign="top"><span>Measurement: mA / V / / mV </span><br />
<span>Simulation: mA / V / / mV</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum input voltage</span></td>
<td colspan="2" valign="top"><span>30V DC</span></td>
</tr>
<tr>
<td valign="top"><span>Input impedance measurement</span></td>
<td colspan="2" valign="top"><span>mV / V:&gt; 1 MΩ </span><br />
<span>Current measurement: 10 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Response time</span></td>
<td colspan="2" valign="top"><span>&lt;100 ms</span></td>
</tr>
<tr>
<td valign="top"><span>Load impedance</span></td>
<td colspan="2" valign="top"><span>&gt; 10 kΩ at mV / V </span><br />
<span>&lt;750Ω at mA</span></td>
</tr>
<tr>
<td valign="top"><span>Refresh rate display</span></td>
<td colspan="2" valign="top"><span>10 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Isolation</span></td>
<td colspan="2" valign="top"><span>500V DC</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="2" valign="top"><span>Internal memory </span><br />
<span>150000 readings</span></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="2" valign="top"><span>USB 2.0</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>2.4&#8243; TFT LCD </span><br />
<span>240 x 320 pixels </span><br />
<span>LED illuminated</span></td>
</tr>
<tr>
<td valign="top"><span>Output voltage current loop</span></td>
<td colspan="2" valign="top"><span>24V DC / 24-mA</span></td>
</tr>
<tr>
<td valign="top"><span>HART mA loop resistance</span></td>
<td colspan="2" valign="top"><span>250 Ω ± 20%</span></td>
</tr>
<tr>
<td valign="top"><span>Special features</span></td>
<td colspan="2" valign="top"><span>Step and ramp function </span><br />
<span>Automatic and manual </span><span>mode √x, x2: For the measuring function</span></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td colspan="2" valign="top"><span>Adjustable threshold up to 100 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="2" valign="top"><span>3.7V / 2300-mAh Li-ion battery</span></td>
</tr>
<tr>
<td valign="top"><span>Charging time</span></td>
<td colspan="2" valign="top"><span>About 5 h</span></td>
</tr>
<tr>
<td valign="top"><span>Power adapter</span></td>
<td colspan="2" valign="top"><span>Input: 100 &#8230; 240V AC / 50/60 Hz </span><br />
<span>Output: 5V / 1 A DC</span></td>
</tr>
<tr>
<td valign="top"><span>Battery life</span></td>
<td colspan="2" valign="top"><span>Approx. 18 h: Simulation and measurement with low LCD illumination, approx. 8 h: Measurement with low LCD illumination</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>162 x 82 x 40 mm / 6.4 x 3.2 x 1.6 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>About 300 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Degree of protection</span></td>
<td colspan="2" valign="top"><span>IP20</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="2" valign="top"><span>Battery operation: 0 &#8230; 55°C / 32 &#8230; 131°F, 30 &#8230; 90% RH Main </span><span>operation: 0 &#8230; 45°C / 32 &#8230; 113°F, 30 &#8230; 90% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="2" valign="top"><span>-20 .. 60°C / -4 &#8230; 140°F, 30 &#8230; 90% RH non-condensing</span></td>
</tr>
<tr>
<td valign="top"><span>Heating time</span></td>
<td colspan="2" valign="top"><span>About 15 minutes</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-20/">Current Calibrator PCE-LOC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11230</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-123-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123-ica-incl-iso-calibration-certificate/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 02:54:51 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11219</guid>

					<description><![CDATA[<p><strong>PCE-123-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123-ica-incl-iso-calibration-certificate/">Current Calibrator PCE-123-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Current calibrator PCE-123-ICA<br />
Digital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals / Control signals as well as frequencies and temperature / Incl. ISO Calibration Certificate<br />
</strong></p>
<p>The PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.</p>
<p>The calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.</p>
<div>
<div> &#8211; 4 to 20mA (1kΩ, 24V power)<br />
&#8211; 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V<br />
&#8211; Type-K, J, E, T temperature thermocouple sensors (°C or °F)<br />
&#8211; Frequency range 1 to 62,500Hz<br />
&#8211; Basic accuracy 0.025 %<br />
&#8211; Easy operation via keypad<br />
&#8211; Automatic ramp function<br />
&#8211; Selectable between 0 to 20mA/ 0 to 24mA<br />
&#8211; Input 0 to 100% (mA, mV, V )<br />
&#8211; Alarm beep &#8216;open&#8217; (mA) or &#8216;short circuit&#8217; (mV, V)<br />
&#8211; <strong>Incl. ISO Calibration Certificate</strong></div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>mA DC current<br />
(maximum load at 1kΩ, powered by 24V)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>4 to 20-mA / 0 to 20-mA / 0 to 24-mA</td>
</tr>
<tr>
<td>Resolution</td>
<td>1µA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.025% ±3µA</td>
</tr>
<tr>
<td>Alert</td>
<td>Beeps when there is a short circuit or ouput current &gt;1mA .</td>
</tr>
<tr>
<td colspan="2"><strong>mV current, V DC<br />
(power 1-mA)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>0 to 100.00 mV<br />
0 to 10.000 V<br />
0 to 1.0000 V</td>
</tr>
<tr>
<td>Resolution</td>
<td>10 µV<br />
1 mV<br />
1.0000 V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.05% ±30 µV<br />
± 0.05% ±3 mV<br />
± 0.05% ±300 µV</td>
</tr>
<tr>
<td>Alert</td>
<td>Beeps when there is a short circuit or ouput current &gt;10mV.</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature sensor thermocouple type-K, J, E, T<br />
(1 kΩ min.)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>K: -200 &#8230; 0°C / -328 &#8230; 32°F and 0 &#8230; 1370°C / 32 &#8230; 2498°F<br />
J: -100 &#8230; 0°C / -148 &#8230; 32°F and 0 &#8230; 760°C / 32 &#8230; 1400°F<br />
E: -10 &#8230; 0°C / 14 &#8230; 32°F and 0 &#8230; 700°C / 32 &#8230; 1292°F<br />
T: -200 &#8230; 0°C / -328 &#8230; 32°F and T: 0 &#8230; 400°C / 32 &#8230; 752°F</td>
</tr>
<tr>
<td>Resolution</td>
<td>1°C / 1.8°F (across entire range)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>K: ± 1.1°C / 2°F  and ± 0.8°C /  1.4°F<br />
J:  ± 0.9°C / 1.6°F and ± 0.7°C / 1.3°F<br />
E: ± 0.9°C / 1.6°F and ± 0.7°C / 1.3°F<br />
T:  ± 1.0°C / 1.8°F and ± 0.8°C / 1.4°F</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>1 to 125Hz and 126 to 62.5kHz</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.04Hz</td>
</tr>
<tr>
<td>Selection</td>
<td>604 frequencies</td>
</tr>
<tr>
<td colspan="2"><strong>General characteristics</strong></td>
</tr>
<tr>
<td>Display</td>
<td>5 position LCD</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F, &lt;85% r.h.</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60°C / -4 &#8230; 140 °F; &lt;85% r.h.</td>
</tr>
<tr>
<td>Power</td>
<td>1 9V battery or 6 x 1.5V batteries</td>
</tr>
<tr>
<td>Consumption</td>
<td>60-mA to 180-mA (depending on output)</td>
</tr>
<tr>
<td>Battery indicator</td>
<td>5.5V for 150-mA</td>
</tr>
<tr>
<td>Dimensions</td>
<td>88 x 168 x 26 mm / 3.4 x 6.6 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>330 g / 11.6 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123-ica-incl-iso-calibration-certificate/">Current Calibrator PCE-123-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11219</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-123</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 02:50:30 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11216</guid>

					<description><![CDATA[<p><strong>PCE-123</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123/">Current Calibrator PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Digital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals / control signals as well as frequencies and temperature</strong></p>
<p>The PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.</p>
<p>The calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.</p>
<div>
<div> &#8211; 4 to 20mA (1kΩ, 24V power)<br />
&#8211; 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V<br />
&#8211; Type-K, J, E, T temperature thermocouple sensors (°C or °F)<br />
&#8211; Frequency range 1 to 62,500Hz<br />
&#8211; Basic accuracy 0.025 %<br />
&#8211; Easy operation via keypad<br />
&#8211; Automatic ramp function<br />
&#8211; Selectable between 0 to 20mA/ 0 to 24mA<br />
&#8211; Input 0 to 100% (mA, mV, V )<br />
&#8211; Alarm beep &#8216;open&#8217; (mA) or &#8216;short circuit&#8217; (mV, V)</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td colspan="2"><strong>mA DC current<br />
(maximum load at 1kΩ, powered by 24V)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>4 to 20mA / 0 to 20mA / 0 to 24mA</td>
</tr>
<tr>
<td>Resolution</td>
<td>1µA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.025% ±3µA</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;1mA .</td>
</tr>
<tr>
<td colspan="2"><strong>mV current, V DC<br />
(power 1mA)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>0 to 100.00 mV<br />
0 to 10.000 V<br />
0 to 1.0000 V</td>
</tr>
<tr>
<td>Resolution</td>
<td>10 µV<br />
1 mV<br />
1.0000 V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.05% ±30 µV<br />
± 0.05% ±3 mV<br />
± 0.05% ±300 µV</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;10mV.</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature sensor thermocouple type-K, J, E, T<br />
(1 kΩ min.)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>K: -200 &#8230; 0 °C / -328 &#8230; 32 °F and 0 &#8230; 1370 °C / 32 &#8230; 2498 °F<br />
J: -100 &#8230; 0 °C / -148 &#8230; 32 °F and 0 &#8230; 760 °C / 32 &#8230; 1400 °F<br />
E: -10 &#8230; 0 °C / 14 &#8230; 32 °F and 0 &#8230; 700°C / 32 &#8230; 1292 °F<br />
T: -200 &#8230; 0°C / -328 &#8230; 32 °F and T: 0 &#8230; 400 °C / 32 &#8230; 752 °F</td>
</tr>
<tr>
<td>Resolution</td>
<td>1°C (across entire range)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>K: ±1.1°C and ±0.8°C<br />
J:  ±0.9°C and ±0.7°C<br />
E: ±0.9°C and ±0.7°C<br />
T:  ±1.0°C and ±0.8°C</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>1 to 125Hz and 126 to 62.5kHz</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.04Hz</td>
</tr>
<tr>
<td>Selection</td>
<td>604 frequencies</td>
</tr>
<tr>
<td colspan="2"><strong>General characteristics</strong></td>
</tr>
<tr>
<td>Display</td>
<td>5 position LCD</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50 °C / 32 &#8230; 122 °F &lt;85% r.h.</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60 °C / -4 &#8230; 140 °F; &lt;85% r.h.</td>
</tr>
<tr>
<td>Power</td>
<td>1 9V battery or 6 x 1.5V batteries</td>
</tr>
<tr>
<td>Consumption</td>
<td>60mA to 180mA (depending on output)</td>
</tr>
<tr>
<td>Battery indicator</td>
<td>5.5V for 150mA</td>
</tr>
<tr>
<td>Dimensions</td>
<td>88 x 168 x 26mm / 3.4 x 6.6 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>330 g / 11.6 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-123/">Current Calibrator PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11216</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-LOC 10</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-10/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 02:47:54 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11203</guid>

					<description><![CDATA[<p><strong>PCE-LOC 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-10/">Current Calibrator PCE-LOC 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Current calibrator PCE-LOC 10<br />
Process calibrator for 0/4 &#8230; 20-mA signals / Simulation of active and passive sensors / 24V DC encoder / Measurement of process currents possible</strong></div>
<div></div>
<div>The process calibrator is used to simulate 0/4 &#8230; 20-mA signals. The process calibrator can be used to calibrate display devices, data loggers, process recorders etc. The process calibrator can also be used to measure the process signal 0/4 &#8230; 20-mA to test sensors and transmitters. The process calibrator is able to simulate both active sensors (source) and passive sensors (sink).</div>
<div></div>
<div>The process value can be set directly using the buttons on the process calibrator. However, it is also possible for the process calibrator to run an automatic ramp. As a further feature, the process calibrator can also provide 24V DC for sensors in order to test them in the process before commissioning. The output current from the sensor can be measured at the same time.</div>
<div></div>
<div>&#8211; Simulation of 0/4 &#8230; 20-mA<br />
&#8211; For active and passive sensor simulations<br />
&#8211; Large LCD<br />
&#8211; Easy handling<br />
&#8211; Ramp function<br />
&#8211; 24V sensor supply possible</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong><span>Current simulation (active)</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>(max. burden 1 kOhm)</span></strong></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top" width="67"><strong><span>Resolution </span></strong></td>
<td colspan="2" valign="top" width="218"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 22-mA</span></td>
<td valign="top"><span>0.001-mA               </span></td>
<td colspan="2" valign="top"><span>± 0.05% of sim. value + 4 µA</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current simulation (passive)</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong><span>(max. burden 1 kOhm / max. 5 &#8230; 25V DC)</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 22-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td colspan="2" valign="top"><span>± 0.05% of sim. value + 4 µA</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage transmitter f. current loop</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>24V DC / 25-mA</span></td>
<td valign="top"></td>
<td colspan="2" valign="top"><span>± 10%</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>-0.2 &#8230; 28V</span></td>
<td valign="top"><span>1 mV</span></td>
<td colspan="2" valign="top"><span>± 0.02% of meas. + 2 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current measurement</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>-1 &#8230; 22-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td colspan="2" valign="top"><span>± 0.02% of meas. + 4 µA</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current measurement</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong><span>(Loop current with voltage transmitter function)</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Area</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0 &#8230; 22-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td colspan="2" valign="top"><span>± 0.02% of meas. + 4 µA</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>More specifications</span></strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="3" valign="top"><span>2 x 1.5V AA batteries</span></td>
</tr>
<tr>
<td valign="top"><span>Max. Tension</span></td>
<td colspan="3" valign="top"><span>30V</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="3" valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, &lt; 80% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="3" valign="top"><span>-10 &#8230; 60°C / 14 &#8230; 140°F, &lt; 95% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="3" valign="top"><span>180 x 90 x 47 mm / 7.1 x 3.5 x 1.9 in</span></td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top"><span>Approx. 500 g / 1.1 lbs</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-loc-10/">Current Calibrator PCE-LOC 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11203</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-LT 15</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-lt-15/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 02:28:46 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11198</guid>

					<description><![CDATA[<p><strong>PCE-LT 15</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-lt-15/">Current Calibrator PCE-LT 15</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Current calibrator</strong><strong> PCE-LT 15<br />
LAN tester for fast network cable inspection / Combination device consisting of LAN tester and multimeter with voltage and resistance measurement</strong></div>
<div></div>
<div>The LAN tester PCE-LT 15 is a combination device which detects configuration errors in the network and at the same time can be used as a multimeter. Thus, the periphery of a network can be quickly checked with the LAN tester. With the LAN tester PCE-LT 15 it is possible to check 8-pin data cables with RJ-45 connectors for continuity, open connections, and short circuits. In addition to the LAN test function, the LAN Tester can also measure DC and AC voltages.</div>
<div></div>
<div>With the LAN tester, which also serves as a multimeter, it is possible to perform a continuity test with buzzer and a diode test. The LAN tester is also a device that identifies the most common network installation errors. The two-row LEDs successively indicate the pin assignment of the cable to be tested. In the event of a short circuit, more than two LEDs light up simultaneously.</div>
<div></div>
<div>&#8211; Combination device of LAN tester and multimeter<br />
&#8211; LCD<br />
&#8211; Checks Lankabel and patch fields<br />
&#8211; Continuity test and diode test possible<br />
&#8211; Overload indicator<br />
&#8211; Short circuit display</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measuring function</span></td>
<td valign="top"><strong><span>AC</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>750V</span></td>
<td valign="top"><span>1V</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (1% from + 5 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring function         </span></td>
<td valign="top"><strong><span>DC</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 V</span></td>
<td valign="top"><span>1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (0.5% of v / m + 3Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring function</span></td>
<td valign="top"><strong><span>Resistance</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 kΩ</span></td>
<td valign="top"><span>1 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40 kΩ</span></td>
<td valign="top"><span>10 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400 kΩ</span></td>
<td valign="top"><span>100 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 MΩ</span></td>
<td valign="top"><span>1 kΩ</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (1.2% from + 3 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><strong><span>Resistance</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40 MΩ</span></td>
<td valign="top"><span>10 kΩ</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (2% from + 4 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td colspan="2" valign="top"><span>400 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Alarm</span></td>
<td colspan="2" valign="top"><span>Measured value &lt;25Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>LED bargraph for LAN testers</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>LC display for multimeter functions</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply   </span></td>
<td colspan="2" valign="top"><span>LAN tester: 1 x 9V 6F22 battery</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Multimeter: 2 x 1.5V AAA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>Handset: 165 x 82 x 42 mm / 6.5 x 3.2 x 1.7 in   </span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Remote unit: 75 x 30 x 25 mm / 3 x 1.2 x 1 in </span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>Handset: 240 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Remote unit: 30 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Electric security</span></td>
<td colspan="2" valign="top"><span>CAT III 600V</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-lt-15/">Current Calibrator PCE-LT 15</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11198</post-id>	</item>
		<item>
		<title>Current Calibrator PCE-DM 4</title>
		<link>https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-dm-4/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 02:21:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11190</guid>

					<description><![CDATA[<p><strong>PCE-DM 4</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-dm-4/">Current Calibrator PCE-DM 4</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Current calibrator </strong><strong>PCE-DM 4<br />
Voltmeter with transistor test / Square function generation / Large LCD display / Voltage test up to 1000V / Protective rubber cover / Diode test / Continuity test / Current measurement up to 20 A.</strong></div>
<div></div>
<div>The voltmeter has many functions. In addition to voltage measurement up to 1000V, the voltmeter can also measure currents directly up to 20 A. This means that this voltmeter can also measure larger currents compared to other multimeters. Another special feature of the voltmeter is the transistor hFE test. During this test, transistors can be inserted into the voltmeter and their amplification can be checked. It does not matter to the voltmeter whether it is an NPN or PNP transistor. The voltmeter shows the current gain for the corresponding transistors.</div>
<div></div>
<div>In addition to the measurement functions, the voltmeter can also generate a square-wave voltage of up to 10 kHz. Thanks to this function on the voltmeter, it can be checked, for example, whether the built-in frequency counters are working properly in industrial operation. The rubber cover on the voltmeter protects the measuring device from rough vibrations. Thanks to this rubber cover on the voltmeter, damage to the measuring equipment is prevented.</div>
<div></div>
<div>&#8211; TRMS measurements AC / DC<br />
&#8211; NPN and PNP transistor testing<br />
&#8211; Rubberized housing with tripod holder<br />
&#8211; Generation of a quadratic function<br />
&#8211; Automatic shutdown<br />
&#8211; Continuity test and diode test</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top">DC</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top" width="74">Resolution</td>
<td colspan="2" valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">200 mV</td>
<td valign="top">100 µV</td>
<td colspan="2" valign="top">± (0.5% +5 digits)</td>
</tr>
<tr>
<td valign="top">2V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">± (0.5% +3 digits)</td>
</tr>
<tr>
<td valign="top">20V</td>
<td valign="top">10 mV</td>
<td colspan="2" valign="top">± (0.5% +3 digits)</td>
</tr>
<tr>
<td valign="top">200V</td>
<td valign="top">100 mV</td>
<td colspan="2" valign="top">± (0.5% +3 digits)</td>
</tr>
<tr>
<td valign="top">1000V</td>
<td valign="top">1V</td>
<td colspan="2" valign="top">± (1.0% +10 digits)</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 1000V DC / AC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">AC</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td colspan="2" valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">2V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">± (0.8% +5 digits)</td>
</tr>
<tr>
<td valign="top">20V</td>
<td valign="top">10 mV</td>
<td colspan="2" valign="top">± (0.8% +5 digits)</td>
</tr>
<tr>
<td valign="top">200V</td>
<td valign="top">100 mV</td>
<td colspan="2" valign="top">± (0.8% +5 digits)</td>
</tr>
<tr>
<td valign="top">1000V</td>
<td valign="top">1V</td>
<td colspan="2" valign="top">± (1.2% +10 digits)</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 1000V DC / AC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">The accuracies refer to 10 &#8230; 100% of the respective measuring ranges, one</td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency of 40 &#8230; 400 Hz with a sine wave (True RMS) and a crest factor</td>
</tr>
<tr>
<td colspan="4" valign="top">(Crest factor): CF &lt; 3. With a crest factor CF &gt; 2 the increases</td>
</tr>
<tr>
<td colspan="4" valign="top">1% accuracy.</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Capacity</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td colspan="2" valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">6 nF</td>
<td valign="top">1 pF</td>
<td colspan="2" valign="top">± (5.0% +40 digits)</td>
</tr>
<tr>
<td valign="top">60 nF</td>
<td valign="top">10 pF</td>
<td colspan="2" valign="top">± (2.5% +20 digits)</td>
</tr>
<tr>
<td valign="top">600 nF</td>
<td valign="top">100 pF</td>
<td colspan="2" valign="top">± (2.5% +20 digits)</td>
</tr>
<tr>
<td valign="top">6 µF</td>
<td valign="top">1 nF</td>
<td colspan="2" valign="top">± (2.5% +20 digits)</td>
</tr>
<tr>
<td valign="top">60 µF</td>
<td valign="top">10 nF</td>
<td colspan="2" valign="top">± (2.5% +20 digits)</td>
</tr>
<tr>
<td valign="top">600μF</td>
<td valign="top">100 nF</td>
<td colspan="2" valign="top">± (5.0% +10 digits)</td>
</tr>
<tr>
<td valign="top">6 mF</td>
<td valign="top">1 µF</td>
<td colspan="2" valign="top">± (5.0% +40 digits)</td>
</tr>
<tr>
<td valign="top">20 mF</td>
<td valign="top">10 µF</td>
<td colspan="2" valign="top">± (5.0% +40 digits)</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 600V DC / AC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">The accuracies refer to 10 &#8230; 100% of the respective measuring ranges</td>
</tr>
<tr>
<td colspan="4" valign="top">Response time for capacities&gt; 1 mF approx. 8 seconds</td>
</tr>
<tr>
<td colspan="4" valign="top">The accuracy does not include the loading capacity</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Transistor test</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td colspan="2" valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">0 &#8230; 1000 hFE</td>
<td valign="top">1 hFE</td>
<td colspan="2" valign="top">&#8211;</td>
</tr>
<tr>
<td colspan="4" valign="top">For NPN and PNP transistors</td>
</tr>
<tr>
<td colspan="4" valign="top">Base current approx. 10 µA</td>
</tr>
<tr>
<td colspan="4" valign="top">Collector-emitter voltage approx. 3V</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Direct current</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td valign="top" width="143">Accuracy</td>
<td valign="top" width="189">Voltage recording</td>
</tr>
<tr>
<td valign="top">20 µA</td>
<td valign="top">0.01 µA</td>
<td valign="top">± (1.2% +8 digits)</td>
<td valign="top">1.25 mV / µA</td>
</tr>
<tr>
<td valign="top">200 µA</td>
<td valign="top">0.1 µA</td>
<td valign="top">± (1.2% +8 digits)</td>
<td valign="top">0.125 mV / µA</td>
</tr>
<tr>
<td valign="top">2 mA</td>
<td valign="top">1 µA</td>
<td valign="top">± (1.2% +8 digits)</td>
<td valign="top">125 mV / mA</td>
</tr>
<tr>
<td valign="top">20 mA</td>
<td valign="top">10 µA</td>
<td valign="top">± (1.2% +8 digits)</td>
<td valign="top">3.75 mV / mA</td>
</tr>
<tr>
<td valign="top">200 mA</td>
<td valign="top">100 µA</td>
<td valign="top">± (1.2% +8 digits)</td>
<td valign="top">3.75 mV / mA</td>
</tr>
<tr>
<td valign="top">2 A</td>
<td valign="top">1 mA</td>
<td valign="top">± (1.5% +10 digits)</td>
<td valign="top">37.5 mV / A</td>
</tr>
<tr>
<td valign="top">20 A.</td>
<td valign="top">10 mA</td>
<td valign="top">± (2.0% +6 digits)</td>
<td valign="top">37.5 mV / A</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Fuse up to the measuring range 200-mA: 200-mA / 250V</td>
</tr>
<tr>
<td colspan="4" valign="top">Fuses from a measuring range of 2 A: 20 A / 250V</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Alternating current</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td valign="top">Accuracy</td>
<td valign="top">Voltage recording</td>
</tr>
<tr>
<td valign="top">200-mA</td>
<td valign="top">100 µA</td>
<td valign="top">± (1.5% +15 digits)</td>
<td valign="top">3.75 mV / mA</td>
</tr>
<tr>
<td valign="top">2 A</td>
<td valign="top">1-mA</td>
<td valign="top">± (2.0% +5 digits)</td>
<td valign="top">37.5 mV / A</td>
</tr>
<tr>
<td valign="top">20 A.</td>
<td valign="top">10-mA</td>
<td valign="top">± (3.0% +10 digits)</td>
<td valign="top">37.5 mV / A</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Fuse up to the measuring range 200-mA: 200-mA / 250V</td>
</tr>
<tr>
<td colspan="4" valign="top">Fuses from a measuring range of 2 A: 20 A / 250V</td>
</tr>
<tr>
<td colspan="4" valign="top">The accuracies refer to 10 &#8230; 100% of the respective measuring ranges,</td>
</tr>
<tr>
<td colspan="4" valign="top">a frequency of 40 &#8230; 400 Hz with a sine wave (True RMS) and one</td>
</tr>
<tr>
<td colspan="4" valign="top">Crest factor: CF &lt; 3. With a crest factor CF &gt; 2 the increases</td>
</tr>
<tr>
<td colspan="4" valign="top">1% accuracy.</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Resistance</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Resolution</td>
<td valign="top">Accuracy</td>
<td valign="top">Short circuit current</td>
</tr>
<tr>
<td valign="top">200 Ω</td>
<td valign="top">0.1 Ω</td>
<td valign="top">± (0.8% +5 digits)</td>
<td valign="top">approx.0.4-mA</td>
</tr>
<tr>
<td valign="top">2 kΩ</td>
<td valign="top">1 Ω</td>
<td valign="top">± (0.8% +3 digits)</td>
<td valign="top">approx. 100 µA</td>
</tr>
<tr>
<td valign="top">20 kΩ</td>
<td valign="top">10 Ω</td>
<td valign="top">± (0.8% +3 digits)</td>
<td valign="top">approx. 10 µA</td>
</tr>
<tr>
<td valign="top">200 kΩ</td>
<td valign="top">100 Ω</td>
<td valign="top">± (0.8% +3 digits)</td>
<td valign="top">approx. 1 µA</td>
</tr>
<tr>
<td valign="top">2 MΩ</td>
<td valign="top">1 kΩ</td>
<td valign="top">± (0.8% +3 digits)</td>
<td valign="top">approx. 0.2 µA</td>
</tr>
<tr>
<td valign="top">200 MΩ</td>
<td valign="top">100 kΩ</td>
<td valign="top">± (5% +30 digits)</td>
<td valign="top">approx. 0.2 µA</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Voltage with open circuit: approx. 1V</td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 600V DC / AC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Diode test</td>
<td valign="top">Test current</td>
<td valign="top">Test voltage</td>
<td valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Approx.0.4-mA</td>
<td valign="top">Approx.3.3V</td>
<td valign="top">5%</td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 600 V DC / AC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Continuity test</td>
<td valign="top">Test current</td>
<td valign="top">Test voltage</td>
<td valign="top">Accuracy</td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">Approx.0.4-mA</td>
<td valign="top">Approx.3.3V</td>
<td valign="top">5%</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 600 V DC / AC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">Beep at 50 ± 20Ω</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Function generation</td>
<td colspan="2" valign="top">Tension</td>
<td valign="top">Function generation</td>
</tr>
<tr>
<td valign="top">(square)</td>
<td colspan="2" valign="top">Approx.3.3V</td>
<td valign="top">50 Hz, 100 Hz, 200 Hz, 500</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
<td valign="top">Hz, 1 kHz, 2 kHz</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
<td valign="top">5 kHz, 10 kHz</td>
</tr>
<tr>
<td colspan="4" valign="top">Surge protection: 600V DC / AC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Further specification</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">LCD display</td>
</tr>
<tr>
<td valign="top">Largest display</td>
<td colspan="3" valign="top">1999 (3 1/2)</td>
</tr>
<tr>
<td valign="top">Measuring rate</td>
<td colspan="3" valign="top">Approx. 3 measurements per second</td>
</tr>
<tr>
<td valign="top">Overrange</td>
<td colspan="3" valign="top">&#8220;OL&#8221; display</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">0 &#8230; 40°C / 32 &#8230; 104°F, &lt; 75% RH non-condensing</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">1 x 9V block battery</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">190 x 88.5 x 27.5 mm</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">Approx. 320 g / &lt; 1 lb (with battery)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/calibrator-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%aa%e0%b8%ad%e0%b8%9a%e0%b9%80%e0%b8%97%e0%b8%b5%e0%b8%a2%e0%b8%9a/current-calibrator/current-calibrator-pce-dm-4/">Current Calibrator PCE-DM 4</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>