<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Current Clamp - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/current-clamp/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/current-clamp/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 11 Aug 2026 15:24:32 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.14</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Current Clamp - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/current-clamp/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>TECPEL DCM-2609D AC/DC Digital Clamp Meter + 17025 Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%a7%e0%b8%b1%e0%b8%94%e0%b9%84%e0%b8%9f%e0%b8%9f%e0%b9%89%e0%b8%b2/%e0%b9%81%e0%b8%84%e0%b8%a5%e0%b8%a1%e0%b8%9b%e0%b9%8c%e0%b8%a1%e0%b8%b4%e0%b9%80%e0%b8%95%e0%b8%ad%e0%b8%a3%e0%b9%8c/tecpel-dcm-2609d-ac-dc-digital-clamp-meter-17025-calibration-certificate/</link>
		
		<dc:creator><![CDATA[Alex]]></dc:creator>
		<pubDate>Tue, 11 Aug 2026 15:24:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.amet.co.th/?post_type=product&#038;p=25839</guid>

					<description><![CDATA[<p>Free 17025 Calibration Certificate (Up to 1000A)</p>
<p>The post <a href="https://www.amet.co.th/shop/%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%a7%e0%b8%b1%e0%b8%94%e0%b9%84%e0%b8%9f%e0%b8%9f%e0%b9%89%e0%b8%b2/%e0%b9%81%e0%b8%84%e0%b8%a5%e0%b8%a1%e0%b8%9b%e0%b9%8c%e0%b8%a1%e0%b8%b4%e0%b9%80%e0%b8%95%e0%b8%ad%e0%b8%a3%e0%b9%8c/tecpel-dcm-2609d-ac-dc-digital-clamp-meter-17025-calibration-certificate/">TECPEL DCM-2609D AC/DC Digital Clamp Meter + 17025 Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b data-path-to-node="4" data-index-in-node="4">TECPEL DCM-2609D</b> is a rugged, high-precision digital clamp meter designed for measuring both AC and DC current in demanding industrial, commercial, and electrical maintenance applications. Equipped with a 6600-count digital display, fast analog bargraph, and a large jaw opening, the DCM-2609D allows accurate non-contact current measurements without breaking the electrical circuit. It combines comprehensive multimeter capabilities—including AC/DC voltage, resistance, frequency, continuity—into an ergonomic, heavy-duty instrument built for daily field troubleshooting.</p>
<h3 data-path-to-node="6">Key Features</h3>
<ul data-path-to-node="7">
<li>
<p data-path-to-node="7,0,0"><b data-path-to-node="7,0,0" data-index-in-node="0">AC/DC Current Measurement:</b> Accurately measures both AC and DC current up to 1000A with high resolution.</p>
</li>
<li>
<p data-path-to-node="7,1,0"><b data-path-to-node="7,1,0" data-index-in-node="0">6600-Count Display with Bargraph:</b> Large digital LCD screen accompanied by a fast analog bar graph for rapid trend observation.</p>
</li>
<li>
<p data-path-to-node="7,2,0"><b data-path-to-node="7,2,0" data-index-in-node="0">Data Hold:</b> Capture inrush current peaks or freeze static readings on screen for easy data recording.</p>
</li>
<li>
<p data-path-to-node="7,3,0"><b data-path-to-node="7,3,0" data-index-in-node="0">Zero Adjustment Function:</b> One-touch zero button for precise DC current measurements and offset cancellation.</p>
</li>
<li>
<p data-path-to-node="7,4,0"><b data-path-to-node="7,4,0" data-index-in-node="0">Full Multimeter Functions:</b> Measures AC/DC Voltage, Resistance, Frequency, Continuity (with audible buzzer), and Diode testing.</p>
</li>
<li>
<p data-path-to-node="7,5,0"><b data-path-to-node="7,5,0" data-index-in-node="0">Safety &amp; Durability:</b> Engineered to meet international safety standards (EN61010-1, EN61010-2-032, CAT IV 600V, CAT III 1000V,) with durable, double-molded housing.</p>
</li>
<li>CE approved</li>
<li>
<p data-path-to-node="7,6,0"><b data-path-to-node="7,6,0" data-index-in-node="0">Auto Power Off:</b> Battery preservation feature automatically powers down the device after inactivity.</p>
</li>
</ul>
<div class="preview-body-holder removable-parent order-handle"></div>
<h3 data-path-to-node="9">Technical Specifications</h3>
<table data-path-to-node="10">
<thead>
<tr>
<td><strong>Parameter</strong></td>
<td><strong>Measurement Range</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="10,1,0,0"><b data-path-to-node="10,1,0,0" data-index-in-node="0">DC Current</b></span></td>
<td><span data-path-to-node="10,1,1,0">660A / 2000 A</span></td>
<td><span data-path-to-node="10,1,2,0">±(2.0% rdg + 5 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,2,0,0"><b data-path-to-node="10,2,0,0" data-index-in-node="0">AC Current</b></span></td>
<td><span data-path-to-node="10,2,1,0">660A / 1500A</span></td>
<td><span data-path-to-node="10,2,2,0">±(2.0% rdg + 5 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,3,0,0"><b data-path-to-node="10,3,0,0" data-index-in-node="0">DC Voltage</b></span></td>
<td><span data-path-to-node="10,3,1,0">6.6V / 66V / 660V / 1000V</span></td>
<td><span data-path-to-node="10,3,2,0">±(0.5% rdg + 2 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,4,0,0"><b data-path-to-node="10,4,0,0" data-index-in-node="0">AC Voltage</b></span></td>
<td><span data-path-to-node="10,4,1,0">6.6V / 66V / 660V / 750V</span></td>
<td><span data-path-to-node="10,4,2,0">±(1.5% rdg + 8 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,5,0,0"><b data-path-to-node="10,5,0,0" data-index-in-node="0">Resistance</b></span></td>
<td><span data-path-to-node="10,5,1,0">660Ω / 6.6kΩ / 66kΩ / 660kΩ / 6.6MΩ / 66MΩ</span></td>
<td><span data-path-to-node="10,5,2,0">±(1.0% rdg + 5 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,6,0,0"><b data-path-to-node="10,6,0,0" data-index-in-node="0">Frequency</b></span></td>
<td><span data-path-to-node="10,6,1,0">66Hz / 660 Hz / 6.6 kHz / 66kHz / 660kHz / 1MHz</span></td>
<td><span data-path-to-node="10,6,2,0">±(0.1% rdg + 5 dgt)</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,7,0,0"><b data-path-to-node="10,7,0,0" data-index-in-node="0">Jaw Conductor Size</b></span></td>
<td><span data-path-to-node="10,7,1,0">Approx. 57 mm max.</span></td>
<td><span data-path-to-node="10,7,2,0">—</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,8,0,0"><b data-path-to-node="10,8,0,0" data-index-in-node="0">Display</b></span></td>
<td><span data-path-to-node="10,8,1,0">3-3/4 Digit LCD (6600 Counts) with Bargraph</span></td>
<td><span data-path-to-node="10,8,2,0">—</span></td>
</tr>
<tr>
<td><span data-path-to-node="10,9,0,0"><b data-path-to-node="10,9,0,0" data-index-in-node="0">Power Source</b></span></td>
<td><span data-path-to-node="10,9,1,0">9V Battery (6F22)</span></td>
<td><span data-path-to-node="10,9,2,0">—</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%a7%e0%b8%b1%e0%b8%94%e0%b9%84%e0%b8%9f%e0%b8%9f%e0%b9%89%e0%b8%b2/%e0%b9%81%e0%b8%84%e0%b8%a5%e0%b8%a1%e0%b8%9b%e0%b9%8c%e0%b8%a1%e0%b8%b4%e0%b9%80%e0%b8%95%e0%b8%ad%e0%b8%a3%e0%b9%8c/tecpel-dcm-2609d-ac-dc-digital-clamp-meter-17025-calibration-certificate/">TECPEL DCM-2609D AC/DC Digital Clamp Meter + 17025 Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">25839</post-id>	</item>
		<item>
		<title>UT210E + 17025 Calibration Mini Clamp Meters</title>
		<link>https://www.amet.co.th/shop/current-clamp/ut210e-17025-calibration-mini-clamp-meters/</link>
		
		<dc:creator><![CDATA[Alex]]></dc:creator>
		<pubDate>Fri, 24 Jul 2026 08:08:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.amet.co.th/?post_type=product&#038;p=25720</guid>

					<description><![CDATA[<p>สินค้าพร้อม Certificate สอบเทียบตามมาตรฐาน ISO17025</p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/ut210e-17025-calibration-mini-clamp-meters/">UT210E + 17025 Calibration Mini Clamp Meters</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb_column vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element wpex-rcss-0" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;18px&quot;,&quot;tp&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<p>Features of UT210 Series Mini Clamp Meters</p>
</div>
</div>
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element vc_custom_1646965489456">
<div class="wpb_wrapper">
<p>Certifications: CE, UKCA, cETLus</p>
</div>
</div>
</div>
</div>
</div>
<div class="wpb_column vc_column_container vc_col-sm-6">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element wpex-rcss-1" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<div>● Ergonomic and lightweight</div>
<div>● Auto range, 2~3 times/s sampling rate</div>
</div>
</div>
</div>
</div>
</div>
<div class="wpb_column vc_column_container vc_col-sm-6">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element wpex-rcss-2" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<div>● LCD backlight, data hold</div>
<div>● Auto power off, low battery indication</div>
</div>
<div>
<div class="wpb_column vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element vc_custom_1646965554104 wpex-rcss-3" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;18px&quot;,&quot;tp&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<p>Specifications of UT210 Series Mini Clamp Meters</p>
</div>
</div>
</div>
</div>
</div>
<div class="wpb_column product-table-col vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper"></div>
</div>
</div>
<div class="wpb_column product-table-col vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column wpb_content_element product-table-style2 columns-7 wpex-rcss-4" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;,&quot;pp&quot;:&quot;13px&quot;}}">
<div class="wpb_wrapper">
<table width="689">
<tbody>
<tr>
<td width="189">Specifications</td>
<td width="84">Range</td>
<td width="90">UT210A</td>
<td width="85">UT210B</td>
<td width="83">UT210C</td>
<td width="83">UT210D</td>
<td width="75">UT210E</td>
</tr>
<tr>
<td rowspan="2">AC current (A)</td>
<td>200A</td>
<td>±(2.5%+20)</td>
<td>±(2.5%+20)</td>
<td>±(2%+10)</td>
<td>±(2.5%+8)</td>
<td></td>
</tr>
<tr>
<td>100A</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td>±(2.5%+5)</td>
</tr>
<tr>
<td rowspan="2">DC current (A)</td>
<td>200A</td>
<td></td>
<td></td>
<td></td>
<td>±(2%+3)</td>
<td></td>
</tr>
<tr>
<td>100A</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td>±(2%+3)</td>
</tr>
<tr>
<td>AC voltage (V)</td>
<td>600V</td>
<td></td>
<td></td>
<td>±(1%+3)</td>
<td>±(1%+3)</td>
<td>±(1%+3)</td>
</tr>
<tr>
<td>DC voltage (V)</td>
<td>600V</td>
<td></td>
<td></td>
<td>±(0.7%+3)</td>
<td>±(0.7%+3)</td>
<td>±(0.7%+3)</td>
</tr>
<tr>
<td>Resistance (Ω)</td>
<td>20MΩ</td>
<td></td>
<td></td>
<td>±(1%+2)</td>
<td>±(1%+2)</td>
<td>±(1%+2)</td>
</tr>
<tr>
<td>Frequency (Hz)</td>
<td>60kHz</td>
<td></td>
<td></td>
<td></td>
<td>±(0.1%+4)</td>
<td></td>
</tr>
<tr>
<td>Capacitance (F)</td>
<td>20mF</td>
<td></td>
<td></td>
<td>±(4%+5)</td>
<td>±(4%+5)</td>
<td>±(4%+5)</td>
</tr>
<tr>
<td rowspan="2">Temperature</td>
<td>-40~1000℃</td>
<td></td>
<td></td>
<td>±(1%+3)</td>
<td>±(1%+3)</td>
<td></td>
</tr>
<tr>
<td>-40~1832℉</td>
<td></td>
<td></td>
<td>±(1.5%+5)</td>
<td>±(1.5%+5)</td>
<td></td>
</tr>
<tr>
<td colspan="7">Features</td>
</tr>
<tr>
<td>Display count</td>
<td></td>
<td>2000</td>
<td>2000</td>
<td>2000</td>
<td>2000</td>
<td>2000</td>
</tr>
<tr>
<td>Continuity buzzer</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Auto range</td>
<td></td>
<td></td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Jaw opening</td>
<td></td>
<td>16mm</td>
<td>16mm</td>
<td>17mm</td>
<td>17mm</td>
<td>17mm</td>
</tr>
<tr>
<td>Diode test</td>
<td>Around 3.0V</td>
<td></td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td colspan="7">General Characteristics</td>
</tr>
<tr>
<td>Power</td>
<td colspan="6">1.5V battery (R03) x 2</td>
</tr>
<tr>
<td>Display</td>
<td colspan="6">39.3mm x 26.5mm</td>
</tr>
<tr>
<td>Product color</td>
<td colspan="6">Red and grey</td>
</tr>
<tr>
<td>Product net weight</td>
<td colspan="6">UT210A/B: 150g (batteries included); UT210C/D/E: 170g</td>
</tr>
<tr>
<td>Product size</td>
<td colspan="6">UT210A/B: 158mm x 60mm x 33.5mm; UT210C/D/E: 175mm x 60mm x 33.5mm</td>
</tr>
<tr>
<td>Standard accessories</td>
<td colspan="6" width="500">Batteries, test leads (UT210C/UT210D/UT210E), point contact temperature probe (UT210C/UT210D)</td>
</tr>
<tr>
<td>Standard individual packing</td>
<td colspan="6">Gift box, English manual, carrying bag (UT210C/UT210D/UT210E)</td>
</tr>
<tr>
<td>Standard quantity per carton</td>
<td colspan="6">40pcs</td>
</tr>
<tr>
<td>Standard carton measurement</td>
<td colspan="6">UT210A/B: 345mm x 245mm x 300mm; UT210C/D/E: 385mm x 345mm x 305mm</td>
</tr>
<tr>
<td>Standard carton gross weight</td>
<td colspan="6">UT210A/B: 8kg; UT210C: 14.8kg; UT210D: 8.2kg; UT210E: 13.6kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/ut210e-17025-calibration-mini-clamp-meters/">UT210E + 17025 Calibration Mini Clamp Meters</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">25720</post-id>	</item>
		<item>
		<title>UT204+ with 17025 Calibration Certificate 600A Digital Clamp Meters</title>
		<link>https://www.amet.co.th/shop/current-clamp/ut204-with-17025-calibration-certificate-600a-digital-clamp-meters/</link>
		
		<dc:creator><![CDATA[Alex]]></dc:creator>
		<pubDate>Fri, 24 Jul 2026 08:05:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.amet.co.th/?post_type=product&#038;p=25717</guid>

					<description><![CDATA[<p>สินค้ามาพร้อม Certificate สอบเทียบตามมาตรฐาน ISO17025</p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/ut204-with-17025-calibration-certificate-600a-digital-clamp-meters/">UT204+ with 17025 Calibration Certificate 600A Digital Clamp Meters</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb_column vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element wpex-rcss-0" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;18px&quot;,&quot;tp&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<p>Features of UT200+ Series 400A/600A Digital Clamp Meters</p>
</div>
</div>
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element  vc_custom_1646982799400">
<div class="wpb_wrapper"><span style="color: #555555; font-size: 14.4px;">● True RMS</span></div>
</div>
</div>
</div>
</div>
<div class="wpb_column vc_column_container vc_col-sm-6">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element wpex-rcss-1" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<p>● LCD backlight</p>
<p>● Large screen and display digits</p>
<p>● 60mF large capacitance measurement (UT202A+/UT204+)</p>
<p>● Neutral/live wire test (UT202A+/UT204+)</p>
<p>&nbsp;</p>
</div>
<div class="wpb_column vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column has-custom-color wpex-child-inherit-color wpb_content_element vc_custom_1646982345497 wpex-rcss-3" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;18px&quot;,&quot;tp&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;}}">
<div class="wpb_wrapper">
<p>Specifications of UT200+ Series 400A/600A Digital Clamp Meters</p>
</div>
</div>
</div>
</div>
</div>
<div class="wpb_column product-table-col vc_column_container vc_col-sm-12">
<div class="vc_column-inner">
<div class="wpb_wrapper">
<div class="wpb_text_column wpb_content_element product-table-style2 columns-7 wpex-rcss-4" data-wpex-rcss="{&quot;font-size&quot;:{&quot;d&quot;:&quot;16px&quot;,&quot;pl&quot;:&quot;14px&quot;,&quot;pp&quot;:&quot;13px&quot;}}">
<div class="wpb_wrapper">
<table width="568">
<tbody>
<tr>
<td width="163">Specifications</td>
<td width="90">Range</td>
<td width="63">UT201+</td>
<td width="63">UT202+</td>
<td width="63">UT202A+</td>
<td width="63">UT203+</td>
<td width="63">UT204+</td>
</tr>
<tr>
<td rowspan="2">AC current (A)</td>
<td>400A</td>
<td>±(2%+10)</td>
<td>±(2%+10)</td>
<td></td>
<td>±(2.5%+5)</td>
<td></td>
</tr>
<tr>
<td>600A</td>
<td></td>
<td></td>
<td>±(2%+10)</td>
<td></td>
<td>±(2.5%+5)</td>
</tr>
<tr>
<td>AC current frequency (Hz)</td>
<td>50Hz~100Hz</td>
<td>±(1%+5)</td>
<td>±(1%+5)</td>
<td>±(1%+5)</td>
<td></td>
<td></td>
</tr>
<tr>
<td rowspan="2">DC current (A)</td>
<td>400A</td>
<td></td>
<td></td>
<td></td>
<td>±(2.5%+5)</td>
<td></td>
</tr>
<tr>
<td>600A</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td>±(2.5%+5)</td>
</tr>
<tr>
<td>AC voltage (V)</td>
<td>600V</td>
<td>±(0.8%+5)</td>
<td>±(0.8%+5)</td>
<td>±(0.8%+5)</td>
<td>±(0.8%+5)</td>
<td>±(0.8%+5)</td>
</tr>
<tr>
<td rowspan="2">AC voltage frequency(Hz)</td>
<td>10Hz~10kHz</td>
<td>±(1%+5)</td>
<td>±(1%+5)</td>
<td>±(1%+5)</td>
<td></td>
<td></td>
</tr>
<tr>
<td>10Hz~60kHz</td>
<td></td>
<td></td>
<td></td>
<td>±(0.5%+2)</td>
<td>±(0.5%+2)</td>
</tr>
<tr>
<td>DC voltage (A)</td>
<td>600V</td>
<td>±(0.5%+2)</td>
<td>±(0.5%+2)</td>
<td>±(0.5%+2)</td>
<td>±(0.5%+2)</td>
<td>±(0.5%+2)</td>
</tr>
<tr>
<td rowspan="2">Resistance (Ω)</td>
<td>40MΩ</td>
<td>±(0.8%+2)</td>
<td>±(0.8%+2)</td>
<td></td>
<td>±(0.8%+2)</td>
<td></td>
</tr>
<tr>
<td>60MΩ</td>
<td></td>
<td></td>
<td>±(0.8%+2)</td>
<td></td>
<td>±(0.8%+2)</td>
</tr>
<tr>
<td rowspan="3">Capacitance (F)</td>
<td>4mF</td>
<td></td>
<td>±(4%+5)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>40mF</td>
<td></td>
<td></td>
<td></td>
<td>±(4%+5)</td>
<td></td>
</tr>
<tr>
<td>60mF</td>
<td></td>
<td></td>
<td>±(4%+5)</td>
<td></td>
<td>±(4%+5)</td>
</tr>
<tr>
<td>Temperature (℃)</td>
<td>-40℃~1000℃</td>
<td></td>
<td>±(1.5%+5)</td>
<td></td>
<td></td>
<td>±(1.5%+5)</td>
</tr>
<tr>
<td>Frequency (Hz)</td>
<td>10Hz~10MHz</td>
<td></td>
<td></td>
<td>±(0.1%+4)</td>
<td>±(0.1%+4)</td>
<td>±(0.1%+4)</td>
</tr>
<tr>
<td colspan="7">Features</td>
</tr>
<tr>
<td>Display count</td>
<td></td>
<td>4000</td>
<td>4000</td>
<td>6000</td>
<td>4000</td>
<td>6000</td>
</tr>
<tr>
<td>Auto range</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Jaw opening</td>
<td></td>
<td>28mm</td>
<td>28mm</td>
<td>28mm</td>
<td>28mm</td>
<td>28mm</td>
</tr>
<tr>
<td>True RMS</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>NCV</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Live wire test</td>
<td></td>
<td></td>
<td></td>
<td>√</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td>Continuity test</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Diode</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>MAX/MIN</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Relative mode</td>
<td></td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Zero mode</td>
<td></td>
<td></td>
<td></td>
<td></td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Data hold</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Low battery indication</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Auto power off</td>
<td></td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td colspan="7">General Characteristics</td>
</tr>
<tr>
<td>Power</td>
<td colspan="6" width="405">1.5V battery (R03) x 2</td>
</tr>
<tr>
<td>Display</td>
<td colspan="6">37mm x 25mm</td>
</tr>
<tr>
<td>Product color</td>
<td colspan="6">Red and grey</td>
</tr>
<tr>
<td>Product net weight</td>
<td colspan="6">UT201+/UT202+/UT202A+：248g; UT203+/UT204+:235g</td>
</tr>
<tr>
<td>Product size</td>
<td colspan="6">215mm x 63mm x 36mm</td>
</tr>
<tr>
<td>Standard accessories</td>
<td colspan="6" width="405">Batteries, test leads, Themocouple (UT202+/UT204+)</td>
</tr>
<tr>
<td>Standard individual packing</td>
<td colspan="6">Gift box, Carring bag, English manual</td>
</tr>
<tr>
<td>Standard quantity per carton</td>
<td colspan="6">40pcs</td>
</tr>
<tr>
<td>Standard carton measurement</td>
<td colspan="6" width="405">485mm x 295mm x 385mm</td>
</tr>
<tr>
<td>Standard carton gross weight</td>
<td colspan="6" width="405">UT202A+: 17.8kg; UT203+: 16.8kg; UT201+/202+/204+: 17.3kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/ut204-with-17025-calibration-certificate-600a-digital-clamp-meters/">UT204+ with 17025 Calibration Certificate 600A Digital Clamp Meters</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">25717</post-id>	</item>
		<item>
		<title>DCM-032B : TECPEL 4000 Count Digital Clamp Meter</title>
		<link>https://www.amet.co.th/shop/current-clamp/dcm-032b-tecpel-4000-count-digital-clamp-meter/</link>
					<comments>https://www.amet.co.th/shop/current-clamp/dcm-032b-tecpel-4000-count-digital-clamp-meter/#respond</comments>
		
		<dc:creator><![CDATA[Alex]]></dc:creator>
		<pubDate>Mon, 23 Feb 2026 01:15:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.amet.co.th/?post_type=product&#038;p=25526</guid>

					<description><![CDATA[<p>DCM-032B/DCM-033B series Hand-held automatic shifting t [...]</p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/dcm-032b-tecpel-4000-count-digital-clamp-meter/">DCM-032B : TECPEL 4000 Count Digital Clamp Meter</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>DCM-032B/DCM-033B series Hand-held automatic shifting true effective value digital hook meter. It designed in accordance with the safety standard EN61010-2010 CAT II600V/CAT III 300V level with full-function gear anti-burn protection which can meet high reliability and High safety operation requirements;</p>
<p>The product contains the basic functions of electrical measurement with high-precision measurement and extended temperature measurement functions. The more novel appearance design makes it an excellent measurement tool for electronic motors with superior performance.</p>
<table border="1" width="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>AC Current（A）</td>
<td>0.04〜400A</td>
<td>±(2％+ 10）</td>
</tr>
<tr>
<td>AC Current Frequency（Hz）</td>
<td>50Hz〜100Hz</td>
<td>±(1％+ 5）</td>
</tr>
<tr>
<td>AC Voltage（V）</td>
<td>600V</td>
<td>±(0.8％+ 5）</td>
</tr>
<tr>
<td>AC Voltage Frequency（Hz）</td>
<td>10Hz〜10kHz</td>
<td>±(1％+ 5）</td>
</tr>
<tr>
<td>DC Voltage（V）</td>
<td>600V</td>
<td>±(0.5％+ 2）</td>
</tr>
<tr>
<td>Resistance（Ω）</td>
<td>40MΩ</td>
<td>±(0.8％+ 2）</td>
</tr>
<tr>
<td>Capacitance（F）</td>
<td>4mF</td>
<td>±(4％+ 5）</td>
</tr>
<tr>
<td>Temperature（℃）</td>
<td>-40〜1000℃</td>
<td>±(1.5％+ 5）</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/dcm-032b-tecpel-4000-count-digital-clamp-meter/">DCM-032B : TECPEL 4000 Count Digital Clamp Meter</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/current-clamp/dcm-032b-tecpel-4000-count-digital-clamp-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">25526</post-id>	</item>
		<item>
		<title>Current Clamp PCE-830-1</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-830-1/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 28 Jan 2021 02:05:03 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11323</guid>

					<description><![CDATA[<p><strong>PCE-830-1</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-830-1/">Current Clamp PCE-830-1</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-830-1 Current Clamp<br />
with 3 phases / Measures power and analyses harmonics / Includes memory, interface, and software</strong></p>
<p align="justify">The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Current Clamp. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductors) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 Current Clamp the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the included analysis software. The device comes with everything needed to be measuring and analysing from the moment it arrives. Although the Current Clamp comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when a recalibration is required.</p>
<p align="justify">&#8211; Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors<br />
&#8211; Measures effective real value (V 123 and I 123)<br />
&#8211; Measures active power (W, KW, MW, GW)<br />
&#8211; Measures apparent and reactive power (KVA, KVAR)<br />
&#8211; Power Factor (PF), phase angle (Φ)<br />
&#8211; Measures energy and work (Wh, KWh, KVARh, PFh)<br />
&#8211; Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a factory to be determined<br />
&#8211; Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors])<br />
&#8211; CT conditions (1 to 600) and PT (1 to 3000) are programmable<br />
&#8211; Indicates current wave forms and voltage overlap.<br />
&#8211; 512 KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases / 4 conductors<br />
&#8211; Indicates wave forms, efficiency parameters, and harmonic distortion<br />
&#8211; Backlit LCD with dot matrix<br />
&#8211; Average power (AD in W, KW, MW)<br />
&#8211; Maximum power (MD in W, KW, MW) with the programmable period<br />
&#8211; Analysis of harmonic distortion up to a curvature of 99<br />
&#8211; Indication of up to 50º form of harmonic wave<br />
&#8211; Indication of the wave form with maximum value (1024 readings / period)<br />
&#8211; Analysis of absolute distortion (%THD-F)<br />
&#8211; Diagram of graphic equilibrium with parameters of a 3 phase system<br />
&#8211; Detects up to 28 transistors (time and cycles) with a programmable threshold (%)<br />
&#8211; Relation of 3 phases of voltage or asymmetrical current (VUR)<br />
&#8211; Factor of 3 phases of voltage and asymmetrical current (d0%, d2%)<br />
&#8211; USB port (optically insulated)<br />
&#8211; Integrated timer and calendar to record data<br />
&#8211; Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801 ~30mm / 1.2 in, PCE-6802 ~55mm / 2.2 in, PCE-3007 ~170mm / 6.7 in</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td>Measurement values</td>
<td>Measurement ranges / resolution / accuracy</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<br />
<strong>Watts AC</strong> (50 Hz or 60 Hz, PF 0.5 up to 1)</td>
<td>5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W<br />
1.000 kW to 9.999 kW / 0.001 k W / ±1% ±8 W<br />
10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W<br />
100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW<br />
1000 kW to 9999 kW / 1 kW / ±1% ±8 kW</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<br />
<strong>Current AC</strong> (50 Hz or 60 Hz, auto range select, TRMS)</td>
<td>0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A<br />
0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A<br />
4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A</td>
</tr>
<tr>
<td><strong>Voltage AC</strong> (50 Hz or 60 Hz, TRMS)</td>
<td>20.0 V to 500.0 V / 0.1 V / ±0.5% ±5 digits<br />
(measure between phase and neutral)<br />
20.0 V to 600.0 V / 0.1 V / ±0.5% ±5 digits<br />
(measure between phase and neutral)</td>
</tr>
<tr>
<td><strong>Harmonic distortion</strong> of AC voltage</td>
<td>1º to 20º / 0.1% / ±1.0%<br />
21º to 49º / 0.1% / 4% of reading ±2.0%<br />
50º to 99º / 0.1% / 6% of reading ±2.0%</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<strong><br />
Harmonics </strong>of AC current in %</td>
<td>1º to 20º / 0.1% / ±0.2% of reading ±1.0%<br />
11º to 20º / 0.1% / ±2% of reading ±1.0%<br />
21º to 50º (A)/ 0.1% / ±5% of reading ±1.0%<br />
21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0%<br />
51º to 99º / 0.1% / ±35% of reading ±1.0%</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<br />
<strong>Power Factor </strong>(PF)</td>
<td>0.00 to 1.00 / 0.01 / ±0.04</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<br />
<strong>Phase angle </strong>(Phi)</td>
<td>-180° to 180° / 0.1° / ±1°</td>
</tr>
<tr>
<td>PCE-830 + PCE-6801<br />
<strong>Total harmonic distortion</strong></td>
<td>0.0 to 20.0% / 0.1% / ±1%<br />
20.0% to 100% / 0.1% / ±3% of reading ±5%<br />
100% to 999.9% / 0.1% / ±10% of reading ±10%</td>
</tr>
<tr>
<td><strong>Maximum measurement</strong> of AC voltage and current</td>
<td>50 Hz / 19 µS / ±5% ±30 digits<br />
60 Hz / 16 µS / ±5% ±30 digits</td>
</tr>
<tr>
<td><strong>Peak value measurement</strong>of AC voltage and current</td>
<td>1.00 to 99.99 / 0.01 / ±5% ±30 digits</td>
</tr>
<tr>
<td><strong>Frequency range</strong> in automatic mode</td>
<td>45 Hz to 65 Hz / 0.1 Hz / 0.1 Hz</td>
</tr>
<tr>
<td>Memory</td>
<td>512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors</td>
</tr>
<tr>
<td>Port</td>
<td>USB</td>
</tr>
<tr>
<td>Software and cable</td>
<td>included, for Windows 2000, XP, ME</td>
</tr>
<tr>
<td>Display</td>
<td>backlit LCD with dot matrix</td>
</tr>
<tr>
<td>Power</td>
<td>8 AA batteries (Mignon)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>257 mm x 155 mm x 57 mm<br />
10.1 in x 6.1 in x 2.2 in</td>
</tr>
<tr>
<td>Weight</td>
<td>1.16 kg / 2.56 lbs</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>max. 85% relative humidity / -10º C &#8230; +50º C / +14º F &#8230; +122° F</td>
</tr>
<tr>
<td>Type of protection / standards</td>
<td>IEC 61010, 600 V/CAT III</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-830-1/">Current Clamp PCE-830-1</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11323</post-id>	</item>
		<item>
		<title>Current Clamp PCE-360</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-360/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 28 Jan 2021 01:53:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11321</guid>

					<description><![CDATA[<p><strong>PCE-360</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-360/">Current Clamp PCE-360</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-360 Single-Phase / 1-Phase Power Meter</strong><br />
<strong>Power-analyzing clamp meter with data logger functionality / Includes clamps, clips, leads, PC software and data cable</strong></p>
<p align="justify">The PCE-360 is a Single-Phase Power Meter or clamp meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period. The PCE-360 is used for the analysis of voltage (V), current (A), active power (kW), apparent power (kVA), reactive power (kVar), power factor (cos Φ), phase angle (Φ), frequency (Hz), rotary field (UL &gt; 50V), active energy (MWh), apparent energy (MVAh), reactive energy (MVArh), harmonics (1 &#8230; 63 order, via software), and waveforms (via software).</p>
<p align="justify">The meter&#8217;s large and easy-to-read screen displays up to 10 measurements simultaneously. In manual mode, the device stores up to 99 measurements directly. In data logger mode, the device stores up to 10,000,000 sets of measurements to the 4 GB internal memory. Measured values are transferred easily to a PC using the included Windows-compatible software and data cable. In addition, four current clamps, four alligator clips, and four measuring leads are included in the delivery contents.</p>
<p align="justify">-For measurement in real time and over an extended time period up to 578 days @ 5 second sample rate<br />
-Includes clamps, clips, leads, PC software and data cable<br />
-Large, easy-to-read screen displays up to 10 measurements simultaneously<br />
-Stores up to 99 measurements directly in manual mode or up to 10,000,000 sets of measurements to the 4 GB internal memory in data logger mode<br />
-For analysis of voltage (V), current (A), active power (kW), apparent power (kVA), reactive power (kVar), power factor (cos Φ), phase angle (Φ), frequency (Hz), rotary field (UL &gt; 50V), active energy (MWh), apparent energy (MVAh), reactive energy (MVArh), harmonics (1 &#8230; 63 order, via software) and waveforms (via software)<br />
-Battery-saving automatic shutdown after approximately 30 minutes of inactivity<br />
-Device comes factory calibrated &#8211; optional ISO calibration certificate available for an additional fee (see accessories for details)</p>
<table>
<tbody>
<tr>
<td valign="top" width="213"><strong>AC Voltage measurement<br />
</strong></td>
<td width="304">50&#8230;600.0 V True RMS value</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+10 digits / 0.1 V</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>AC Current measurement</strong></td>
<td>3 &#8230; 999.9 A True RMS value</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+15 digits / 0.1 A</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Active Power measurement P<br />
</strong></td>
<td>150 W&#8230; 999.9 kW</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits / 0.1 KW</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Apparent Power measurement S</strong></td>
<td>150 VA&#8230; 999.9 kVA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits / 0.1 KVA</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Reactive Power measurement Q</strong></td>
<td>150 VAR&#8230; 999.9 kVar</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits / 0.1 KVar</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Power Factor measurement</strong></td>
<td>0 &#8230; +1 COSψ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.06</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.001</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Phase angle measurement</strong></td>
<td>-90° &#8230;. +90° ψ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 3°</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Frequency measurement (U &gt; 50V)</strong></td>
<td>40 &#8230; 100 Hz</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1 % of measured value +2 digits</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 Hz</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Three Phase Sequence Detection (UL &gt; 50V)</strong></td>
<td>yes</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Active Power Energy measurement</strong></td>
<td>0 &#8230; 9999 MWh</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Apparent Power Energy measurement</strong></td>
<td>0 &#8230; 9999 MVAh</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Reactive Power Energy measurement</strong></td>
<td>0 &#8230; 9999 MVarh</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 % of measured value</td>
</tr>
<tr>
<td>Resolution</td>
<td>+20 digits</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td>Max. current clamp opening</td>
<td>40 mm / 1.57&#8243;</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td>50 records for manual storage<br />
4 GB SD card for data logging<br />
(99 storage locations with 350,000 data records each)</td>
</tr>
<tr>
<td>Data interface</td>
<td>serial via USB cable</td>
</tr>
<tr>
<td>Display</td>
<td>illuminated LC display</td>
</tr>
<tr>
<td>Power supply</td>
<td>8 x 1.5 V type AA (Mignon)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>235 x 117 x 54 mm / 9.25 x 4.61 x 2.13&#8243;</td>
</tr>
<tr>
<td>Weight</td>
<td>730 g / 1.61 lbs</td>
</tr>
<tr>
<td>Environmental conditions</td>
<td>max. 85% relative humidity / 0 &#8230; +40 °C / 32 &#8230; 104 °F</td>
</tr>
<tr>
<td>Protection class / standards</td>
<td>IP 30 / IEC 61 010, 600 V / CAT III</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-360/">Current Clamp PCE-360</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11321</post-id>	</item>
		<item>
		<title>Current Clamp PCE-PA 8000</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pa-8000/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 09:50:52 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11318</guid>

					<description><![CDATA[<p><strong>PCE-PA 8000</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pa-8000/">Current Clamp PCE-PA 8000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-PA 8000 Current Clamp<br />
real time measurement with registration in the SD card / Integrated timer and calendar to record data / Active, apparent, and reactive power</strong></p>
<p align="justify">The PCE-PA 8000 Current Clamp is able to measure and record the power in both single-phase or three-phase circuits. With the PCE-PA 8000 Current Clamp you will be able to perform prolonged measurements. Measurement values are saved in xls format on the included SD card of our Current Clamp to be easily analyzed on the computer. Measurement sample rate can be set from 2 to 7200 seconds. The PCE-PA 8000 Current Clamp can also measure power and determine both power factor and phase angle. The clamps of the PCE-PA 8000 Current Clamp can be used for cables with a diameter of 50 mm / 2.0 in. The PCE-PA 8000 is the ideal tool to be used in power supply networks. Its 3.7 in / 94 mm display allows you to read all measured values for a quick analysis as well as providing a view of the current, voltage, and power.</p>
<p align="justify">&#8211; Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors<br />
&#8211; Measures effective real value of current and voltage<br />
&#8211; Measures active, apparent, and reactive power<br />
&#8211; Power Factor (PF), phase angle (Φ)<br />
&#8211; Measures voltage up to 600 V<br />
&#8211; Measures current up to 1200 A<br />
&#8211; It meets the IEC 1010 and CAT III 600 V standards<br />
&#8211; Integrated timer and calendar to record data<br />
&#8211; Measured values are recorded in the included SD card<br />
&#8211; Data is stored in Excel format for further study<br />
&#8211; Data can be transferred to a PC through data cable<br />
&#8211; Large 3.7 in / 94 mm LCD display</p>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Technical Specifications</strong></td>
</tr>
<tr>
<td colspan="3"><strong>Voltage (AC V)</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to neutral)</td>
<td>0.1 V</td>
<td>±(0.5 % + 0.5 V)</td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to neutral)</td>
</tr>
<tr>
<td colspan="3"><strong>Current (AC A)</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>20 A</td>
<td>0.001 A (&lt; 10 A)<br />
0.01 A (≥ 10 A)</td>
<td>±(0.5 % + 0.1 V)</td>
</tr>
<tr>
<td>200 A</td>
<td>0.01 A (&lt; 100 A)<br />
0.1 A (≥ 100 A)</td>
<td>±(0.5 % + 0.5 A)</td>
</tr>
<tr>
<td>1200 A</td>
<td>0.1 A (&lt; 1000 A)<br />
1 A (≥ 1000 A)</td>
<td>±(0.5 A + 5 A)</td>
</tr>
<tr>
<td colspan="3"><strong>Active power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KW &#8230; 9.999 KW</td>
<td>0.001 KW</td>
<td>±(1 % + 0.008 KW)</td>
</tr>
<tr>
<td>10 KW &#8230; 99.99 KW</td>
<td>0.01 KW</td>
<td>±(1 % + 0.008 KW)</td>
</tr>
<tr>
<td>100 KW &#8230; 999.9 KW</td>
<td>0.1 KW</td>
<td>±(1 % + 0.8 KW)</td>
</tr>
<tr>
<td>1 MW &#8230; 9.999 MW</td>
<td>0.001 MW</td>
<td>±(1 % + 0.008 MW)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVA &#8230; 9.999 KVA</td>
<td>0.001 KVA</td>
<td>±(1 % + 0.008 KVA)</td>
</tr>
<tr>
<td>10 KVA &#8230; 99.99 KVA</td>
<td>0.01 KVA</td>
<td>±(1 % + 0.08 KVA)</td>
</tr>
<tr>
<td>100 KVA &#8230; 999.9 KVA</td>
<td>0.1 KVA</td>
<td>±(1 % + 0.8 KVA)</td>
</tr>
<tr>
<td>1 MVA &#8230; 9.999 MVA</td>
<td>0.001 MVA</td>
<td>±(1 % + 0.008 MVA)</td>
</tr>
<tr>
<td colspan="3"><strong>Reactive power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVAR &#8230; 9.999 KVAR</td>
<td>0.001 KVAR</td>
<td>±(1 % + 0.008 KVAR)</td>
</tr>
<tr>
<td>10 KVAR &#8230; 99.99 KVAR</td>
<td>0.01 KVAR</td>
<td>±(1 % + 0.08 KVAR)</td>
</tr>
<tr>
<td>100 KVAR &#8230; 999.9 KVAR</td>
<td>0.1 KVAR</td>
<td>±(1 % + 0.8 KVAR)</td>
</tr>
<tr>
<td>1 MVAR &#8230; 9.999 MVAR</td>
<td>0.001 MVAR</td>
<td>±(1 % + 0.008 MVAR)</td>
</tr>
<tr>
<td colspan="3"><strong>Active energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KWh &#8230; 9.999 KWh</td>
<td>0.001 KWh</td>
<td>±(1 % + 0.008 KWh)</td>
</tr>
<tr>
<td>10 KWh &#8230; 99.99 KWh</td>
<td>0.01 KWh</td>
<td>±(1 % + 0.08 KWh)</td>
</tr>
<tr>
<td>100 KWh &#8230; 999.9 KWh</td>
<td>0.1 KWh</td>
<td>±(1 % + 0.8 KWh)</td>
</tr>
<tr>
<td>1 MWh&#8230; 9.999 MWh</td>
<td>0.001 MWh</td>
<td>±(1 % + 0.008 MWh)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVAh &#8230; 9.999 KVAh</td>
<td>0.001 KVAh</td>
<td>±(2 % + 0.008 KVAh)</td>
</tr>
<tr>
<td>10 KVAh &#8230; 99.99 KVAh</td>
<td>0.01 KVAh</td>
<td>±(2 % + 0.08 KVAh)</td>
</tr>
<tr>
<td>100 KVAh &#8230; 999.9 KVAh</td>
<td>0.1 KVAh</td>
<td>±(2 % + 0.8 KVAh)</td>
</tr>
<tr>
<td>1 MVAh&#8230; 9.999 MVAh</td>
<td>0.001 MVAh</td>
<td>±(2 % + 0.008 MVAh)</td>
</tr>
<tr>
<td colspan="3"><strong>Reactive energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVARh &#8230; 9.999 KVARh</td>
<td>0.001 KVARh</td>
<td>±(2 % + 0.008 KVARh)</td>
</tr>
<tr>
<td>10 KVARh &#8230; 99.99 KVARh</td>
<td>0.01 KVARh</td>
<td>±(2 % + 0.08 KVARh)</td>
</tr>
<tr>
<td>100 KVARh &#8230; 999.9 KVARh</td>
<td>0.1 KVARh</td>
<td>±(2 % + 0.8 KVARh)</td>
</tr>
<tr>
<td>1 MVARh&#8230; 9.999 MVARh</td>
<td>0.001 MVARh</td>
<td>±(2 % + 0.008 MVARh)</td>
</tr>
<tr>
<td colspan="3"><strong>Power factor</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 &#8230; 1</td>
<td>0.01</td>
<td>±0.04</td>
</tr>
<tr>
<td colspan="3"><strong>Phase angle</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>-180º &#8230; 180º</td>
<td>0.1º</td>
<td>±1º</td>
</tr>
<tr>
<td colspan="3"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>45 Hz &#8230; 65 Hz</td>
<td>0.1 Hz</td>
<td>0.1 Hz</td>
</tr>
<tr>
<td colspan="3"><strong>General specifications</strong></td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">3.7 in / 94.0 mm LCD (320 x 240 pixels) with LED backlight</td>
</tr>
<tr>
<td>Electrical properties</td>
<td colspan="2">AC V, AC A, active power, apparent power, power factor, phase angle, mains frequency</td>
</tr>
<tr>
<td>Voltage ranges</td>
<td colspan="2">10 V &#8230; 600 V AC, automatic range selection</td>
</tr>
<tr>
<td>Security / Standards</td>
<td colspan="2">IEC1010CAT III 600V</td>
</tr>
<tr>
<td>AC V input resistance</td>
<td colspan="2">10 MΩ</td>
</tr>
<tr>
<td>Operation frequency of current clamps</td>
<td colspan="2">40 Hz &#8230; 1 kHz</td>
</tr>
<tr>
<td>Tested operation frequency of current clamps</td>
<td colspan="2">45 Hz &#8230; 65 Hz</td>
</tr>
<tr>
<td>Overload protection</td>
<td>AC V / 720 V rms</td>
</tr>
<tr>
<td>AC A</td>
<td>1300 A with current clips</td>
</tr>
<tr>
<td>Memory</td>
<td colspan="2">SD card up to 16 GB</td>
</tr>
<tr>
<td>Measurement display rate</td>
<td colspan="2">1 second</td>
</tr>
<tr>
<td>Data logger</td>
<td colspan="2">SD</td>
</tr>
<tr>
<td>Measurement sample rate</td>
<td colspan="2">2 seconds&#8230; 7200 seconds</td>
</tr>
<tr>
<td>Data output</td>
<td colspan="2">USB or RS-232, depending on the connection cable</td>
</tr>
<tr>
<td>Operating temperature</td>
<td colspan="2">0º C &#8230; 50º C / 32° F &#8230; 122° F</td>
</tr>
<tr>
<td>Operating humidity</td>
<td colspan="2">&lt; 80 % H.r.</td>
</tr>
<tr>
<td>Power</td>
<td colspan="2">8 x 1.5 V AA batteries / mains component</td>
</tr>
<tr>
<td>Input current</td>
<td colspan="2">Meter: 300 mA DC<br />
Clamp: 34 mA DC</td>
</tr>
<tr>
<td>Max. diameter</td>
<td colspan="2">50 mm / 1.9 in</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">Meter: 948 g / 33.4 oz (with batteries)<br />
Clip: 467 g / 16.4 oz (with cable)</td>
</tr>
<tr>
<td rowspan="3">Dimensions</td>
<td colspan="2">Meter: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in</td>
</tr>
<tr>
<td colspan="2">Clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in</td>
</tr>
<tr>
<td colspan="2">Jaw: 86 mm / 3.3 in (exterior)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pa-8000/">Current Clamp PCE-PA 8000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11318</post-id>	</item>
		<item>
		<title>Current Clamp PCE-DC 41-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-dc-41-ica-incl-iso-calibration-certificate/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 09:47:37 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11316</guid>

					<description><![CDATA[<p><strong>PCE-DC 41-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-dc-41-ica-incl-iso-calibration-certificate/">Current Clamp PCE-DC 41-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>Current clamp</strong><strong> PCE-DC 41-ICA incl. ISO Calibration Certificat</strong></div>
<div style="text-align: center"><strong>Voltage metering up to 600 V / Current metering up to 600 A / CAT III 600 V</strong></div>
<div>
<p style="text-align: center"><strong>Electrical resistance metering up to 1000 Ω / Contact-free measuring of electrical conductors</strong></p>
</div>
</div>
<div>
<div>The current clamp PCE-DC 41 can measure voltages up to 600 V, currents up to 600 A and electrical resistance up to 1000 Ω. To perform a measurement, you can either use the measuring leads, which are included in the package of the current clamp, or you can use the integrated clamp mechanism. By using the clamp of the current clamp, you are able to measure the electrical parameters of an electrical conductor contact-free and without disconnecting it. You can also check the continuity with the current clamp.</div>
<div>Due to its compact design and light weight, the device is well-suited for mobile use. When using the clamp mechanism, it is also possible to run the current clamp with one hand only. The measured data is shown on the large backlit 4-digit display. By using the peak-hold or data-hold function, you can also freeze the readings on the display. The auto power-off function saves battery power, when the device is not in use.</div>
</div>
<div></div>
<div>
<div>&#8211; Voltage: 600 V AC/DC<br />
&#8211; Current: 600 A AC/DC<br />
&#8211; Electrical Resistance: 1000 Ω<br />
&#8211; Clamp mechanism<br />
&#8211; Continuity check</div>
<div>&#8211; Peak- and data-hold function<br />
&#8211; Measuring leads included in the package<br />
&#8211; 4-digit display<br />
&#8211; Display backlight<br />
&#8211; Auto power-off<br />
&#8211; <strong>Incl. ISO Calibration Certificate</strong></div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td><strong>Direct voltage</strong></td>
</tr>
<tr>
<td></td>
<td><strong>Range</strong></td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>Input impedance: 1 MΩ</td>
<td>600 V</td>
<td>0.1 V</td>
<td>± 1 % + 2 digits</td>
</tr>
<tr>
<td><strong>Direct voltage (peak model)</strong></td>
</tr>
<tr>
<td>Input impedance: 1 MΩ</td>
<td>600 V<br />
0.0 &#8230; 0.01 in</td>
<td>0.1 V<br />
0.0 &#8230; 0.01 in</td>
<td>± 1.5 % + 8 digits<br />
0.0 &#8230; 0.01 in</td>
</tr>
<tr>
<td><strong>Alternating voltage</strong></td>
</tr>
<tr>
<td>Input Impedance: 1 MΩ</td>
<td>600 V</td>
<td>0.1 V</td>
<td>± 1.2 % ± 5 digits<br />
(50 &#8230; 500 Hz)</td>
</tr>
<tr>
<td><strong>Alternating voltage (peak model)</strong></td>
</tr>
<tr>
<td>Input impedance: 1 MΩ</td>
<td>600 V</td>
<td>0.1 V</td>
<td>± 1.7 % + 10 digits</td>
</tr>
<tr>
<td><strong>Direct current</strong></td>
</tr>
<tr>
<td></td>
<td>60 A<br />
600 A</td>
<td>0.01 A<br />
0.1 A</td>
<td>± 2 % + 5 digits</td>
</tr>
<tr>
<td><strong>Direct current (peak model)</strong></td>
</tr>
<tr>
<td></td>
<td>600 A</td>
<td>0.1 A</td>
<td>± 2.5 % + 8 digits</td>
</tr>
<tr>
<td><strong>Alternating current</strong></td>
</tr>
<tr>
<td></td>
<td>60 A<br />
600 A</td>
<td>0.01 A<br />
0.1 A</td>
<td>±2 % + 5 digits (50&#8230;60 Hz)<br />
±3 % + 5 digits (60&#8230;500 Hz)</td>
</tr>
<tr>
<td><strong>Alternating current (peak model)</strong></td>
</tr>
<tr>
<td></td>
<td>600 A</td>
<td>0.01 A</td>
<td>±2.5 % + 10 digits</td>
</tr>
<tr>
<td><strong>Electrical resistance</strong></td>
</tr>
<tr>
<td></td>
<td>1000 Ω</td>
<td>0.1 Ω</td>
<td>± 1 % + 2 digits</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td></td>
</tr>
<tr>
<td><strong>Continuinty check</strong></td>
</tr>
<tr>
<td>Buzzer function<br />
&lt;40 Ω</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>General specifications</strong></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td>Display</td>
<td>4-digit LCD<br />
maximum reading: 6200</td>
</tr>
<tr>
<td>Sampling rate</td>
<td>3 times/s</td>
</tr>
<tr>
<td>Power supply</td>
<td>2 x 1.5 V AAA batteries</td>
</tr>
<tr>
<td>Batter life</td>
<td>50 hours (without buzzer backlight function)</td>
</tr>
<tr>
<td>Auto Power off</td>
<td>After 30 minutes of inactivity</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0.0°C &#8230; 40°C / &lt; 70 % RH<br />
0.0°F &#8230; 104°F</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-10°C &#8230; 60°C / &lt; 80 % RH<br />
14°F &#8230; 140°F</td>
</tr>
<tr>
<td>Maximum clamp opening</td>
<td>Ø 25 mm / Ø 0.1 in</td>
</tr>
<tr>
<td>Dimensions</td>
<td>210 mm x 62 mm x 36 mm /<br />
8.26 in x 2.44 in x 1.41 in</td>
</tr>
<tr>
<td>Weight</td>
<td>273 g / &lt; 1 lb with batteries</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-dc-41-ica-incl-iso-calibration-certificate/">Current Clamp PCE-DC 41-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11316</post-id>	</item>
		<item>
		<title>Current Clamp PCE-CM 40-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-cm-40-ica-incl-iso-calibration-certificate/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 09:44:41 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11314</guid>

					<description><![CDATA[<p><strong>PCE-CM 40-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-cm-40-ica-incl-iso-calibration-certificate/">Current Clamp PCE-CM 40-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Current clamp</strong><strong> PCE-CM 40-ICA incl. ISO Calibration Certificate<br />
Flexible current clamp up to 3000 A / Rogowski coil with 170 mm (6.7in) diameter / Inrush function / Frequency measurement / LC display</strong></div>
<div></div>
<div>The flexible current clamp PCE-CM 40 is suitable for current measurements up to 3000 A AC. In addition to TRMS current measurement, the flexible current clamp can be used to measure inrush currents. The measurement of the current takes place via a flexible Rogowski coil. This means that the electrical conductor around which the flexible current clamp is placed induces a voltage in the ammeter. This voltage is proportional to the current flow through the electrical conductor. This makes it possible to measure very high currents with the flexible current clamp almost without risk. In addition to the current measurement, the flexible current clamp is able to measure frequencies in the range of 50 &#8230; 400 Hz.</div>
<div></div>
<div>The PCE-CM 40 flexible current clamp is used to measure the AC current in machines, systems and electrical installations. Due to the flexible Rogowski coil, which has a diameter of 170 mm, the clamp can be used wherever conventional space clamps can not be used. The measured value of the alternating current is displayed on the illuminated LCD. Furthermore, the measured values ​​can be stored in a memory that can be read out via the Bluetooth interface.</div>
<p>&#8211; Up to 3000 A AC<br />
&#8211; LC display<br />
&#8211; Inrush function<br />
&#8211; Frequency measurement<br />
&#8211; Easy handling<br />
&#8211; Data storage<br />
<strong>&#8211; Incl. ISO Calibration Certificate</strong></p>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="267"><strong><span>AC 50 &#8230; 400 Hz TRMS</span></strong></td>
<td valign="top" width="74"></td>
<td valign="top" width="241"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>30 A AC</span></td>
<td valign="top"><span>0.01A</span></td>
<td valign="top"><span>± (3% of </span><span>measured value + 8 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>300 A AC</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± (3% of </span><span>measured value + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>3000 A AC</span></td>
<td valign="top"><span>1 A</span></td>
<td valign="top"><span>± (3% of </span><span>measured value + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>General technical specifications</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>3000 digit LCD with backlight</span></td>
</tr>
<tr>
<td valign="top"><span>Loop diameter</span></td>
<td colspan="2" valign="top"><span>About 170 x 5 mm / 6.7 x 0.2 in</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="2" valign="top"><span>5 &#8230; 40°C / 41 &#8230; 104°F, max. 80% RH not condensing</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="2" valign="top"><span>-20 &#8230; 60°C / -4 &#8230; 140°F, max. 80% RH not condensing</span></td>
</tr>
<tr>
<td valign="top"><span>Operating altitude</span></td>
<td colspan="2" valign="top"><span>Max. 2000 m</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="2" valign="top"><span>2 x 1.5V AAA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Automatic shutdown</span></td>
<td colspan="2" valign="top"><span>After about 15 minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Security conditions</span></td>
<td colspan="2" valign="top"><span>EN61010-1, EN61010-2-032, EN61326-1</span></td>
</tr>
<tr>
<td valign="top"><span>Overvoltage category</span></td>
<td colspan="2" valign="top"><span>CAT III, 1000 V; CAT IV, 600V</span></td>
</tr>
<tr>
<td valign="top"><span>Pollution degree</span></td>
<td colspan="2" valign="top"><span>2</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-cm-40-ica-incl-iso-calibration-certificate/">Current Clamp PCE-CM 40-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11314</post-id>	</item>
		<item>
		<title>Current Clamp PCE-PCM 3</title>
		<link>https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pcm-3/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 27 Jan 2021 09:41:44 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=11311</guid>

					<description><![CDATA[<p><strong>PCE-PCM 3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pcm-3/">Current Clamp PCE-PCM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Current clamp</strong><strong> PCE-PCM 3<br />
Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var / Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement / Backlight / Voltage measurement / 750 kW power</strong></div>
<div></div>
<div>With the digital multimeter AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the digital multimeter. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the digital multimeter is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional digital multimeter such a measurement is not possible. For the digital multimeter this is not a problem.</div>
<div></div>
<div>With the NCV (Not Connected Voltage) function of the digital multimeter, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the digital multimeter. In addition to the measuring function, the digital multimeter can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the digital multimeter to the terminal, where it can be logged, analyzed and sent.</div>
<div></div>
<div>&#8211; Apparent / active / reactive power<br />
&#8211; Measurement up to the 20th harmonic<br />
&#8211; &#8220;Not Connected Voltage&#8221; function<br />
&#8211; Inrush current measurement<br />
&#8211; Current measurement up to 1000 A AC<br />
&#8211; Bluetooth interface</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="3" valign="top"><span>Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, &lt; 75% RH</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current measurement AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 A</span></td>
<td valign="top"><span>0.01 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600 A</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000 A</span></td>
<td valign="top"><span>1 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input current: 1000 A AC</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230;. 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Inrush current AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 A</span></td>
<td valign="top"><span>0.01 A</span></td>
<td valign="top"><span>For reference only</span></td>
</tr>
<tr>
<td valign="top"><span>600 A</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± 5% + 60 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000 A</span></td>
<td valign="top"><span>1 A</span></td>
<td valign="top"><span>± 5% + 60 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Integral time: 100 ms</span></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Measuring range: 20 &#8230; 1000 A</span></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230;. 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement DC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 0.8% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 750V AC (rms value) or 1000V DC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 0.8% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 750V AC (rms value) or 1000V DC</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230; 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement with</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>The current measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range of the input signal: &gt; 20 AAC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The input current increases with the measuring frequency.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input current: 1000 AAC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement with the</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 kHz</span></td>
<td valign="top"><span>0.001 kHz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range: 10 &#8230; 10 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range of the input signal: &gt; 1V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top" height="27"><span>The input current increases with the measuring frequency.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement </span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>9,999 Hz</span></td>
<td valign="top"><span>0.001 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 kHz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.001 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 kHz</span></td>
<td valign="top"><span>0.01 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 kHz</span></td>
<td valign="top"><span>0.1 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 MHz</span></td>
<td valign="top"><span>0.001 MHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 1000V DC or 750V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Range of voltage input&gt; 2V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(as the input voltage increases, so does the frequency)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Duty cycle</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.1 &#8230; 99.9%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 10 &#8230; 10 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Voltage range: 2 &#8230; 250V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(The voltage increases with the frequency)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Duty cycle with the</span></td>
<td colspan="2" valign="top"><span>Frequency range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Current measurement function</span></td>
<td colspan="2" valign="top"><span>Input current: 20 &#8230; 1000 AAC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Duty cycle with the</span></td>
<td colspan="2" valign="top"><span>Frequency range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Voltage measurement function</span></td>
<td colspan="2" valign="top"><span>Input current: 1 &#8230; 750V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Input impedance: 1MΩ</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Resistivity</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>6 kΩ</span></td>
<td valign="top"><span>0.001 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60 kΩ</span></td>
<td valign="top"><span>0.01 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600 kΩ</span></td>
<td valign="top"><span>0.1 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>6 MΩ</span></td>
<td valign="top"><span>0.001 MΩ</span></td>
<td valign="top"><span>± 2% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60 MΩ</span></td>
<td valign="top"><span>0.1 MΩ</span></td>
<td valign="top"><span>± 2% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring voltage: approx. 0.78V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Continuity test</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Acoustic signal at &lt; 50 Ω</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Test voltage: 1.48V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Capacitance measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>9.999 nF</span></td>
<td valign="top"><span>0.001 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 n.f.</span></td>
<td valign="top"><span>0.01 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 nF</span></td>
<td valign="top"><span>0.1 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9.999 μF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 μF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 μF</span></td>
<td valign="top"><span>0.1 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999mF</span></td>
<td valign="top"><span>0.001 mF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 mF</span></td>
<td valign="top"><span>0.01 mF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Diode measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>3V </span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>DC anode side: approx. 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>DC cathode side: approx. 3.2V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Single phase power measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>3 W / VA / Var</span></td>
<td valign="top"><span>0.01 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>100 W / VA / Var</span></td>
<td valign="top"><span>0.1 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4000 W / VA / Var</span></td>
<td valign="top"><span>1 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>10 kW / VA / var</span></td>
<td valign="top"><span>0.01 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>100 kW / VA / var</span></td>
<td valign="top"><span>0.1 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>750 kW / VA / var</span></td>
<td valign="top"><span>1 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Power factor capacitive / inductive</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.1 &#8230; 1</span></td>
<td valign="top"><span>0.001</span></td>
<td valign="top"><span>± 5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonics measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>1</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 3% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>2 &#8230; 6</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 3.5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>7 &#8230; 8</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 4.5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9 &#8230; 10</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>11 &#8230; 15</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 7% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>16 &#8230; 20</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 10% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The resolution depends on the voltage measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>General specifications</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td colspan="2" valign="top"><span>Automatically and manually adjustable</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum voltage range</span></td>
<td colspan="2" valign="top"><span>1000V DC or 750V AC</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum working height</span></td>
<td colspan="2" valign="top"><span>2000 m / 6561 ft</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>LCD</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum display</span></td>
<td colspan="2" valign="top"><span>5999 Dgt.</span></td>
</tr>
<tr>
<td valign="top"><span>Overrange</span></td>
<td colspan="2" valign="top"><span>&#8220;OIL&#8221;</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range underflow</span></td>
<td colspan="2" valign="top"><span>&#8220;-OL&#8221;</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring rate</span></td>
<td colspan="2" valign="top"><span>3 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Automatic shutdown</span></td>
<td colspan="2" valign="top"><span>After 30 minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="2" valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Battery indicator</span></td>
<td colspan="2" valign="top"><span>Icon if the battery voltage is too low</span></td>
</tr>
<tr>
<td valign="top"><span>Temperature coefficient</span></td>
<td colspan="2" valign="top"><span>0.1 x accuracy x °C / °F*</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="2" valign="top"><span>0 &#8230; 40°C, 32 &#8230; 104°F</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="2" valign="top"><span>-10 &#8230; 60°C, 14 &#8230; 140°F</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  </span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>About 420 g / &lt; 1 lb (with batteries)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Accuracies are given at ambient conditions of 18 &#8230; 28°C / 65 &#8230; 83°F. </span><br />
<span>*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Example:</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Is the current ambient temperature greater than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(50°C / 122°F (current ambient temperature)) &#8211; (40°C / 104°F (operating temperature)<br />
</span><span>= 10°C / 50</span>°F</td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Is the current ambient temperature less than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(0°C (operating temperature)) &#8211; (-5°C / 23°F (current ambient temperature))<br />
</span><span>= 5°C / 41</span>°F</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/current-clamp/current-clamp-pce-pcm-3/">Current Clamp PCE-PCM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>