<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Electrical Tester - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/electrical-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/electrical-tester/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 29 Nov 2022 16:54:12 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Electrical Tester - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/electrical-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Electrical Tester PKT-1260</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pkt-1260/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pkt-1260/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:45:29 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12658</guid>

					<description><![CDATA[<p><strong>PKT-1260</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pkt-1260/">Electrical Tester PKT-1260</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Electrical Tester PKT-1260 with high-resolution TFT / USB port for real-time data transmission / 20 automatic measurement modes and FFT function</strong></div>
<div></div>
<div>Digital storage electrical tester of the latest generation with high-resolution color display, backlight, high bandwith and high sampling rate, VGA-output, large internal memory, USB port and LAN connection for integration into networks. The amazing value for money and modern technology allows a wide range of applications in education, service and quality assurance area.</div>
<div></div>
<div>
<div>
<p>&#8211; high-resolution TFT color display with 800 x 600 pixels and 65536 colors- USB port for real-time data transmission or reading of internal memory</p>
<p>&#8211; saving of measured values and graphics directly onto the USB-stick</p>
<p>&#8211; VGA-output port for external monitor</p>
<p>&#8211; autoset and autoscale function for easy operation</p>
</div>
<div>
<p>&#8211; LAN connection for remote acces via network- internal memory of 10 million points per channel or 15 waveforms</p>
<p>&#8211; 20 automatic measurement modes and FFT function</p>
<p>&#8211; PASS/FAIL function</p>
<p>&#8211; safety: EN 61010-1; CAT II</p>
<table>
<tbody>
<tr>
<td colspan="2"><strong><span lang="EN-US">Technical data</span></strong></td>
</tr>
<tr>
<td>Bandwidth</td>
<td>200 MHz</td>
</tr>
<tr>
<td>Display</td>
<td>20 cm (8”) TFT with 65536 colors</td>
</tr>
<tr>
<td>Resolution</td>
<td>800 x 600 Pixel</td>
</tr>
<tr>
<td>Channel</td>
<td>2 CH</td>
</tr>
<tr>
<td colspan="2"><strong>Measurement acqisition</strong></td>
</tr>
<tr>
<td>Sampling mode</td>
<td>normal/peak detect/average</td>
</tr>
<tr>
<td>Sampling rate each Channel</td>
<td>1 GSa/s</td>
</tr>
<tr>
<td colspan="2"><strong>Input</strong></td>
</tr>
<tr>
<td>Input coupling</td>
<td>AC, DC, GND</td>
</tr>
<tr>
<td>Input impedance</td>
<td>1 MΩ +/- 2 % in parallel with 15 pF +/- 5 pF</td>
</tr>
<tr>
<td>Input voltage</td>
<td>400 V DC or ACpp</td>
</tr>
<tr>
<td colspan="2"><strong>Vertical systems</strong></td>
</tr>
<tr>
<td>Sensitivity</td>
<td>2 mV &#8211; 10 V/Skt/div.</td>
</tr>
<tr>
<td>Rise time</td>
<td>&lt; 1,7 ns</td>
</tr>
<tr>
<td>Accuracy</td>
<td>+/- 3 %</td>
</tr>
<tr>
<td>Vertical resolutions</td>
<td>8 Bits (2 CH simultaneously)</td>
</tr>
<tr>
<td colspan="2"><strong>Horizontal systems</strong></td>
</tr>
<tr>
<td>Horizontal scale</td>
<td>1ns-100s/Skt./div</td>
</tr>
<tr>
<td>Sampling range</td>
<td>0,5 &#8211; 250 S/s</td>
</tr>
<tr>
<td colspan="2"><strong>Trigger</strong></td>
</tr>
<tr>
<td>Trigger type</td>
<td>Edge/Video/Pulse/Slope</td>
</tr>
<tr>
<td>Trigger mode</td>
<td>Auto, Normal, Single</td>
</tr>
<tr>
<td>Trigger coupling</td>
<td>DC, AC, LF, HF</td>
</tr>
<tr>
<td colspan="2"><strong>Measurements</strong></td>
</tr>
<tr>
<td>20 automat. measurements</td>
<td>peak-peak, cycle RMS, Vmax, Vmin, Vtop, Vbase, Vamp, overshoot, preshoot, rise time, fall time, +width, -width, +duty, -duty, delay A→B (rising), delay A→B(falling), frequency, period, min, max</td>
</tr>
<tr>
<td>Phase difference</td>
<td>+/- 3°</td>
</tr>
<tr>
<td colspan="2"><strong>Record</strong></td>
</tr>
<tr>
<td>Record length</td>
<td>10.000.000 points/CH</td>
</tr>
<tr>
<td colspan="2"><strong>Common specifications</strong></td>
</tr>
<tr>
<td>Interfaces</td>
<td>USB, VGA, LAN</td>
</tr>
<tr>
<td>Operation voltage</td>
<td>100 ~ 240 V ACrms / 50/60 Hz</td>
</tr>
<tr>
<td>Dimensions (WxHxD)</td>
<td>340 x 155 x 70 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr class="even">
<td class="first"></td>
<td class="second">1,8 kg</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pkt-1260/">Electrical Tester PKT-1260</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pkt-1260/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12658</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-PA 8300</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8300/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8300/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:38:30 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12654</guid>

					<description><![CDATA[<p><strong>PCE-PA 8300</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8300/">Electrical Tester PCE-PA 8300</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-PA 8300 Electrical Tester<br />
3-phase / 3 current clamps / LCD graphic display / SD card memory</strong></p>
<p align="justify">The PCE-PA 8300 is a Electrical Tester that features a durable enclosure, SD card memory, a LCD graphic display, as well as apparent, effective, and reactive power measurement. The easy-to-use PCE-PA 8300 Electrical Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity.</p>
<p>The PCE-PA 8300 is available for purchase in two different configurations:</p>
<p><strong>Set 1:</strong> Includes 3 current clamps for measurements up to 1200 A AC<br />
<strong>Set 2:</strong> Includes 3 flexible Rogowski coils for measurements up to 3000 A AC (for an additional fee)</p>
<p>Please choose either Set 1 or Set 2 before adding the PCE-PA 8300 to your cart.</p>
<p align="justify">&#8211; Voltage measurement range of 10 V &#8230; 600 V AC<br />
&#8211; Current measurement range of 20 A &#8230; 1200 A AC (Set 1) or 30 A &#8230; 3000 A AC (Set 2)<br />
&#8211; Performance measurement range of 0 kW &#8230; 9.999 MW (VA/VAR)<br />
&#8211; Simultaneous display of harmonics and waveform<br />
&#8211; Graphic Phasor diagram<br />
&#8211; Captures transients including dip, swell, and outage<br />
&#8211; SD card memory<br />
&#8211; LCD graphic display<br />
&#8211; Durable enclosure<br />
&#8211; Compatibility with various manufacturers&#8217; power clamps<br />
&#8211; Adjustable back-up interval, allowing for long-term data collection<br />
&#8211; Auto-setting of measurement range (AC V)<br />
&#8211; Power efficiency, delay angle, and frequency measurement<br />
&#8211; Apparent, effective, and reactive power measurement<br />
&#8211; Harmonic spectrum measurement up to the 50th order</p>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Electrical specifications</strong></td>
</tr>
<tr>
<td colspan="3"><strong>Voltage Measurement (AC V)</strong></td>
</tr>
<tr>
<td>Measurement Range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to neutral)</td>
<td>0.1 V</td>
<td>±(0.5 % + 0.5 V)</td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to phase</td>
<td>0.1 V</td>
<td>±(0.5 % + 0.5 V)</td>
</tr>
<tr>
<td colspan="3"><strong>Current Measurement (AC A) Set 1</strong></td>
</tr>
<tr>
<td>Measurement Range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>20 A</td>
<td>0.001 A (&lt; 10 A)<br />
0.01 A (≥ 10 A)</td>
<td>± (0.5 % + 0.1 A)</td>
</tr>
<tr>
<td>200 A</td>
<td>0.01 A (&lt; 100 A)<br />
0.1 A (≥ 100 A)</td>
<td>± (0.5 % + 0.5 A)</td>
</tr>
<tr>
<td>1200 A</td>
<td>0.1 A (&lt; 1000 A)<br />
1 A (≥ 1000 A)</td>
<td>± (0.5 A + 5 A)</td>
</tr>
<tr>
<td colspan="3"><strong>Current measurement (AC A) Set 2</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>30 A</td>
<td>0.001 A (&lt; 10 A)<br />
0.01 A (≥ 10 A)</td>
<td>±(0.5 % + 0.1 A)</td>
</tr>
<tr>
<td>300 A</td>
<td>0.01 A (&lt; 10 A)<br />
0.1 A (≥ 10 A)</td>
<td>±(0.5 % + 0.5 A)</td>
</tr>
<tr>
<td>3000 A</td>
<td>0.1 A (&lt; 1000 A)<br />
1 A (≥ 1000 A)</td>
<td>±(0.5 A + 5 A)</td>
</tr>
<tr>
<td colspan="3"><strong>Effective power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 KW &#8230; 9.999 KW</td>
<td>0.001 KW</td>
<td>±(1 % + 0.008 KW)</td>
</tr>
<tr>
<td>10 KW &#8230; 99.99 KW</td>
<td>0.01 KW</td>
<td>±(1 % + 0.08 KW)</td>
</tr>
<tr>
<td>100 KW &#8230; 999.9 KW</td>
<td>0.1 KW</td>
<td>±(1 % + 0.8 KW)</td>
</tr>
<tr>
<td>1 MW &#8230; 9.999 MW</td>
<td>0.001 MW</td>
<td>±(1 % + 0.008 MW)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent Power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 KVA &#8230; 9.999 KVA</td>
<td>0.001 KVA</td>
<td>±(1 % + 0.008 KVA)</td>
</tr>
<tr>
<td>10 KVA &#8230; 99.99 KVA</td>
<td>0.01 KVA</td>
<td>±(1 % + 0.08 KVA)</td>
</tr>
<tr>
<td>100 KVA &#8230; 999.9 KVA</td>
<td>0.1 KVA</td>
<td>±(1 % + 0.8 KVA)</td>
</tr>
<tr>
<td>1 MVA &#8230; 9.999 MVA</td>
<td>0.001 MVA</td>
<td>±(1 % + 0.008 MVA)</td>
</tr>
<tr>
<td colspan="3"><strong>Reactive Power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 KVAR &#8230; 9.999 KVAR</td>
<td>0.001 KVAR</td>
<td>±(1 % + 0.008 KVAR)</td>
</tr>
<tr>
<td>10 KVAR &#8230; 99.99 KVAR</td>
<td>0.01 KVAR</td>
<td>±(1 % + 0.08 KVAR)</td>
</tr>
<tr>
<td>100 KVAR &#8230; 999.9 KVAR</td>
<td>0.1 KVAR</td>
<td>±(1 % + 0.8 KVAR)</td>
</tr>
<tr>
<td>1 MVAR &#8230; 9.999 MVAR</td>
<td>0.001 MVAR</td>
<td>±(1 % + 0.008 MVAR)</td>
</tr>
<tr>
<td colspan="3"><strong>Active Energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 KWH &#8230; 9.999 KWH</td>
<td>0.001 KWh</td>
<td>±(2 % + 0.008 KWh)</td>
</tr>
<tr>
<td>10.00 KWH &#8230; 99.99 KWH</td>
<td>0.01 KWh</td>
<td>±(2 % + 0.08 KWh)</td>
</tr>
<tr>
<td>100.0 KWH &#8230; 999.9 KWH</td>
<td>0.01 KWh</td>
<td>±(2 % + 0.8 KWh)</td>
</tr>
<tr>
<td>1 MWH &#8230; 9.999 MWH</td>
<td>0.001 MMh</td>
<td>±(2 % + 0.008 MWh)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent Energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 KVARH &#8230; 9.999 KVARH</td>
<td>0.001 KVARh</td>
<td>± (2 % + 0.008 KVARh)</td>
</tr>
<tr>
<td>10.00 KVARH &#8230; 99.99 KVARH</td>
<td>0.01 KVARh</td>
<td>± (2 % + 0.08 KVARh)</td>
</tr>
<tr>
<td>100.0 KVARH &#8230; 999.9 KVARH</td>
<td>0.01 KVARh</td>
<td>± (2 % + 0.8 KVARh)</td>
</tr>
<tr>
<td>1 MVARH &#8230; 9.999 MVARH</td>
<td>0.001 MVARh</td>
<td>± (2 % + 0.008 MVARh)</td>
</tr>
<tr>
<td colspan="3"><strong>Power Factor</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>0 &#8230; 1</td>
<td>0.01</td>
<td>± 0.04</td>
</tr>
<tr>
<td colspan="3"><strong>Delay Angle</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>-180° &#8230; +180°</td>
<td>0.1°</td>
<td>±1°</td>
</tr>
<tr>
<td colspan="3"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>45 Hz &#8230; 65 Hz</td>
<td>0.1 Hz</td>
<td>± 0.1 Hz</td>
</tr>
<tr>
<td colspan="3"><strong>Harmonic of AC Voltage at 50 / 60 Hz</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>Resolution</td>
<td>Accuracy</td>
</tr>
<tr>
<td>1 &#8230; 20th order</td>
<td>0.001 &#8230; 1 A<br />
0.1 %</td>
<td>± (2 % + 0.5 A)<br />
± (2 % + 10 Digit)</td>
</tr>
<tr>
<td>21 &#8230; 30th order</td>
<td>0.001 &#8230; 1 A<br />
0.1 %</td>
<td>± (2 % + 0.5 A)<br />
± (2 % + 10 Digit)</td>
</tr>
<tr>
<td>21 &#8230; 50th order</td>
<td>0.001 &#8230; 1 A<br />
0.1 %</td>
<td>not specified</td>
</tr>
<tr>
<td colspan="3"><strong>General specifications</strong></td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">3.7 in / 94.0 mm point-matrix LCD (320 * 240 pixel) with LED background lights</td>
</tr>
<tr>
<td>Safety standards</td>
<td colspan="2">IEC1010CAT III 600V</td>
</tr>
<tr>
<td>Input resistance AC V</td>
<td colspan="2">10 MOhm</td>
</tr>
<tr>
<td>Operating frequency of current clamp</td>
<td colspan="2">40 Hz &#8230; 1 kHz</td>
</tr>
<tr>
<td>Tested operating frequency of current clamp</td>
<td colspan="2">45 Hz &#8230; 65 Hz</td>
</tr>
<tr>
<td>Overload protection</td>
<td>AC V<br />
AC A</td>
<td>720 V RMS<br />
1300 A with current clamp</td>
</tr>
<tr>
<td>Data Storage</td>
<td colspan="2">SD memory card</td>
</tr>
<tr>
<td>Refresh interval</td>
<td colspan="2">1 second</td>
</tr>
<tr>
<td>Data logging function</td>
<td colspan="2">logging with real-time speed on SD memory card</td>
</tr>
<tr>
<td>Record interval</td>
<td colspan="2">2 &#8230; 7200 seconds</td>
</tr>
<tr>
<td>Data output (only for live display on computer)</td>
<td colspan="2">per USB or RS232, depending on connection cable</td>
</tr>
<tr>
<td>Operating temperature</td>
<td colspan="2">0° C &#8230; +50° C / 32° F &#8230; 122° F</td>
</tr>
<tr>
<td>Surrounding humidity</td>
<td colspan="2">&lt; 80 % RH<br />
8 x 1.5 V AA batteries</td>
</tr>
<tr>
<td>Voltage Supply</td>
<td colspan="2">9 V adapter</td>
</tr>
<tr>
<td>Current Drain</td>
<td colspan="2">Measurement Device: 300 mA DC<br />
current clamp: 34 mA DC</td>
</tr>
<tr>
<td>Maximum Wire Diameter</td>
<td colspan="2">50 mm / 1.9 in</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">Measurement Device: 948 g / 33.4 oz (incl. battery)<br />
Current clamp: 467 g / 16.4 oz (incl. cable)</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="2">Device: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in<br />
Current clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in<br />
Clamp jaw: 86 mm / 3.3 in (exterior)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8300/">Electrical Tester PCE-PA 8300</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8300/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12654</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-PA 8000</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8000/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8000/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:35:28 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12646</guid>

					<description><![CDATA[<p><strong>PCE-PA 8000</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8000/">Electrical Tester PCE-PA 8000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-PA 8000 Electrical Tester<br />
real time measurement with registration in the SD card / Integrated timer and calendar to record data / Active, apparent, and reactive power</strong></p>
<p align="justify">The PCE-PA 8000 Electrical Tester is able to measure and record the power in both single-phase or three-phase circuits. With the PCE-PA 8000 Electrical Tester you will be able to perform prolonged measurements. Measurement values are saved in xls format on the included SD card of our Electrical Tester to be easily analyzed on the computer. Measurement sample rate can be set from 2 to 7200 seconds. The PCE-PA 8000 Electrical Tester can also measure power and determine both power factor and phase angle. The clamps of the PCE-PA 8000 Electrical Tester can be used for cables with a diameter of 50 mm / 2.0 in. The PCE-PA 8000 is the ideal tool to be used in power supply networks. Its 3.7 in / 94 mm display allows you to read all measured values for a quick analysis as well as providing a view of the current, voltage, and power.</p>
<p align="justify">&#8211; Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors<br />
&#8211; Measures effective real value of current and voltage<br />
&#8211; Measures active, apparent, and reactive power<br />
&#8211; Power Factor (PF), phase angle (Φ)<br />
&#8211; Measures voltage up to 600 V<br />
&#8211; Measures current up to 1200 A<br />
&#8211; It meets the IEC 1010 and CAT III 600 V standards<br />
&#8211; Integrated timer and calendar to record data<br />
&#8211; Measured values are recorded in the included SD card<br />
&#8211; Data is stored in Excel format for further study<br />
&#8211; Data can be transferred to a PC through data cable<br />
&#8211; Large 3.7 in / 94 mm LCD display</p>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Technical Specifications</strong></td>
</tr>
<tr>
<td colspan="3"><strong>Voltage (AC V)</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to neutral)</td>
<td>0.1 V</td>
<td>±(0.5 % + 0.5 V)</td>
</tr>
<tr>
<td>10 V &#8230; 600 V (phase to neutral)</td>
</tr>
<tr>
<td colspan="3"><strong>Current (AC A)</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>20 A</td>
<td>0.001 A (&lt; 10 A)<br />
0.01 A (≥ 10 A)</td>
<td>±(0.5 % + 0.1 V)</td>
</tr>
<tr>
<td>200 A</td>
<td>0.01 A (&lt; 100 A)<br />
0.1 A (≥ 100 A)</td>
<td>±(0.5 % + 0.5 A)</td>
</tr>
<tr>
<td>1200 A</td>
<td>0.1 A (&lt; 1000 A)<br />
1 A (≥ 1000 A)</td>
<td>±(0.5 A + 5 A)</td>
</tr>
<tr>
<td colspan="3"><strong>Active power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KW &#8230; 9.999 KW</td>
<td>0.001 KW</td>
<td>±(1 % + 0.008 KW)</td>
</tr>
<tr>
<td>10 KW &#8230; 99.99 KW</td>
<td>0.01 KW</td>
<td>±(1 % + 0.008 KW)</td>
</tr>
<tr>
<td>100 KW &#8230; 999.9 KW</td>
<td>0.1 KW</td>
<td>±(1 % + 0.8 KW)</td>
</tr>
<tr>
<td>1 MW &#8230; 9.999 MW</td>
<td>0.001 MW</td>
<td>±(1 % + 0.008 MW)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVA &#8230; 9.999 KVA</td>
<td>0.001 KVA</td>
<td>±(1 % + 0.008 KVA)</td>
</tr>
<tr>
<td>10 KVA &#8230; 99.99 KVA</td>
<td>0.01 KVA</td>
<td>±(1 % + 0.08 KVA)</td>
</tr>
<tr>
<td>100 KVA &#8230; 999.9 KVA</td>
<td>0.1 KVA</td>
<td>±(1 % + 0.8 KVA)</td>
</tr>
<tr>
<td>1 MVA &#8230; 9.999 MVA</td>
<td>0.001 MVA</td>
<td>±(1 % + 0.008 MVA)</td>
</tr>
<tr>
<td colspan="3"><strong>Reactive power</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVAR &#8230; 9.999 KVAR</td>
<td>0.001 KVAR</td>
<td>±(1 % + 0.008 KVAR)</td>
</tr>
<tr>
<td>10 KVAR &#8230; 99.99 KVAR</td>
<td>0.01 KVAR</td>
<td>±(1 % + 0.08 KVAR)</td>
</tr>
<tr>
<td>100 KVAR &#8230; 999.9 KVAR</td>
<td>0.1 KVAR</td>
<td>±(1 % + 0.8 KVAR)</td>
</tr>
<tr>
<td>1 MVAR &#8230; 9.999 MVAR</td>
<td>0.001 MVAR</td>
<td>±(1 % + 0.008 MVAR)</td>
</tr>
<tr>
<td colspan="3"><strong>Active energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KWh &#8230; 9.999 KWh</td>
<td>0.001 KWh</td>
<td>±(1 % + 0.008 KWh)</td>
</tr>
<tr>
<td>10 KWh &#8230; 99.99 KWh</td>
<td>0.01 KWh</td>
<td>±(1 % + 0.08 KWh)</td>
</tr>
<tr>
<td>100 KWh &#8230; 999.9 KWh</td>
<td>0.1 KWh</td>
<td>±(1 % + 0.8 KWh)</td>
</tr>
<tr>
<td>1 MWh&#8230; 9.999 MWh</td>
<td>0.001 MWh</td>
<td>±(1 % + 0.008 MWh)</td>
</tr>
<tr>
<td colspan="3"><strong>Apparent energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVAh &#8230; 9.999 KVAh</td>
<td>0.001 KVAh</td>
<td>±(2 % + 0.008 KVAh)</td>
</tr>
<tr>
<td>10 KVAh &#8230; 99.99 KVAh</td>
<td>0.01 KVAh</td>
<td>±(2 % + 0.08 KVAh)</td>
</tr>
<tr>
<td>100 KVAh &#8230; 999.9 KVAh</td>
<td>0.1 KVAh</td>
<td>±(2 % + 0.8 KVAh)</td>
</tr>
<tr>
<td>1 MVAh&#8230; 9.999 MVAh</td>
<td>0.001 MVAh</td>
<td>±(2 % + 0.008 MVAh)</td>
</tr>
<tr>
<td colspan="3"><strong>Reactive energy</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 KVARh &#8230; 9.999 KVARh</td>
<td>0.001 KVARh</td>
<td>±(2 % + 0.008 KVARh)</td>
</tr>
<tr>
<td>10 KVARh &#8230; 99.99 KVARh</td>
<td>0.01 KVARh</td>
<td>±(2 % + 0.08 KVARh)</td>
</tr>
<tr>
<td>100 KVARh &#8230; 999.9 KVARh</td>
<td>0.1 KVARh</td>
<td>±(2 % + 0.8 KVARh)</td>
</tr>
<tr>
<td>1 MVARh&#8230; 9.999 MVARh</td>
<td>0.001 MVARh</td>
<td>±(2 % + 0.008 MVARh)</td>
</tr>
<tr>
<td colspan="3"><strong>Power factor</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>0 &#8230; 1</td>
<td>0.01</td>
<td>±0.04</td>
</tr>
<tr>
<td colspan="3"><strong>Phase angle</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>-180º &#8230; 180º</td>
<td>0.1º</td>
<td>±1º</td>
</tr>
<tr>
<td colspan="3"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td><strong>Resolution</strong></td>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>45 Hz &#8230; 65 Hz</td>
<td>0.1 Hz</td>
<td>0.1 Hz</td>
</tr>
<tr>
<td colspan="3"><strong>General specifications</strong></td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">3.7 in / 94.0 mm LCD (320 x 240 pixels) with LED backlight</td>
</tr>
<tr>
<td>Electrical properties</td>
<td colspan="2">AC V, AC A, active power, apparent power, power factor, phase angle, mains frequency</td>
</tr>
<tr>
<td>Voltage ranges</td>
<td colspan="2">10 V &#8230; 600 V AC, automatic range selection</td>
</tr>
<tr>
<td>Security / Standards</td>
<td colspan="2">IEC1010CAT III 600V</td>
</tr>
<tr>
<td>AC V input resistance</td>
<td colspan="2">10 MΩ</td>
</tr>
<tr>
<td>Operation frequency of current clamps</td>
<td colspan="2">40 Hz &#8230; 1 kHz</td>
</tr>
<tr>
<td>Tested operation frequency of current clamps</td>
<td colspan="2">45 Hz &#8230; 65 Hz</td>
</tr>
<tr>
<td>Overload protection</td>
<td>AC V / 720 V rms</td>
</tr>
<tr>
<td>AC A</td>
<td>1300 A with current clips</td>
</tr>
<tr>
<td>Memory</td>
<td colspan="2">SD card up to 16 GB</td>
</tr>
<tr>
<td>Measurement display rate</td>
<td colspan="2">1 second</td>
</tr>
<tr>
<td>Data logger</td>
<td colspan="2">SD</td>
</tr>
<tr>
<td>Measurement sample rate</td>
<td colspan="2">2 seconds&#8230; 7200 seconds</td>
</tr>
<tr>
<td>Data output</td>
<td colspan="2">USB or RS-232, depending on the connection cable</td>
</tr>
<tr>
<td>Operating temperature</td>
<td colspan="2">0º C &#8230; 50º C / 32° F &#8230; 122° F</td>
</tr>
<tr>
<td>Operating humidity</td>
<td colspan="2">&lt; 80 % H.r.</td>
</tr>
<tr>
<td>Power</td>
<td colspan="2">8 x 1.5 V AA batteries / mains component</td>
</tr>
<tr>
<td>Input current</td>
<td colspan="2">Meter: 300 mA DC<br />
Clamp: 34 mA DC</td>
</tr>
<tr>
<td>Max. diameter</td>
<td colspan="2">50 mm / 1.9 in</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">Meter: 948 g / 33.4 oz (with batteries)<br />
Clip: 467 g / 16.4 oz (with cable)</td>
</tr>
<tr>
<td rowspan="3">Dimensions</td>
<td colspan="2">Meter: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in</td>
</tr>
<tr>
<td colspan="2">Clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in</td>
</tr>
<tr>
<td colspan="2">Jaw: 86 mm / 3.3 in (exterior)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8000/">Electrical Tester PCE-PA 8000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-pa-8000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12646</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-GPA 50-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:30:03 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12638</guid>

					<description><![CDATA[<p><strong>PCE-GPA 50-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-GPA 50-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Electrical Tester </strong><strong>PCE-GPA 50-ICA incl. ISO Calibration Certificate<br />
Current clamp up to 2000 A / TRMS measurement / Power measurement / Harmonic analysis / Graphic display with lighting / Data storage / Mains and battery operation</strong></div>
<div align="center"></div>
<div>The PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.</div>
<div></div>
<div>In addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.</div>
<div></div>
<div>&#8211; Graphic display<br />
&#8211; Data logger on Micro-SD card<br />
&#8211; Measurement for 1 and 3 phases<br />
&#8211; Temperature measurement with thermocouple<br />
&#8211; Voltage measurement 10V &#8230; 600V AC RMS<br />
&#8211; Current measurement 5 &#8230; 2000 A AC RMS<br />
&#8211; Current clamp opening 50 mm<br />
&#8211; Harmonic distortion up to the 50th order<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top" width="0"><strong>Type of measurement</strong></td>
<td colspan="3" valign="top" width="0"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong>AC voltage AC V    </strong></p>
</td>
<td valign="top"><strong>Measuring range      </strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">10 &#8230; 600V</td>
<td valign="top">0.1V</td>
<td valign="top">± (0.5% &#8230; 3 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Peak to peak</td>
<td valign="top">0.1V</td>
<td valign="top">± (5% &#8230; 30 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong>AC AC A</strong></p>
</td>
<td valign="top">5 &#8230; 2000 A</td>
<td valign="top">&lt; 100 A: 0.01 A</td>
<td valign="top">&lt; 200 A: ± (1% + 0.5 A)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top">&lt; 1000 A: 0.1 A</td>
<td valign="top">&gt; 200 A: ± (1% + 5 A)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Peak to peak</td>
<td valign="top">&gt; 1000 A: 1 A</td>
<td valign="top">± (5% + 30 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Power factor (PF)</strong></td>
<td valign="top">0 &#8230; 1</td>
<td valign="top">0.001</td>
<td valign="top">± 0.04</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Phase angle</strong></td>
<td valign="top">-180° &#8230; 180°</td>
<td valign="top">0.1°</td>
<td valign="top">± 1° x PF</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Frequency</strong></td>
<td valign="top">45 &#8230; 65 Hz</td>
<td valign="top">0.1 Hz</td>
<td valign="top">± 0.2 Hz</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Active, blind &amp;</strong></td>
<td valign="top">0 &#8230; 9,999 m</td>
<td valign="top">0.1 &#8230; 0.001 M</td>
<td valign="top">± (1.5% + 20 digits)</td>
</tr>
<tr>
<td valign="top"><strong>apparent power</strong></td>
<td valign="top">(W / VA / VAR)</td>
<td valign="top">(W / VA / VAR)</td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC V</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">0.1V</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">0.1V</td>
<td valign="top">± (4% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC A</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">&lt; 100 A: 0.01 A</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"><strong>Alternating current</strong></td>
<td valign="top"></td>
<td valign="top">&lt; 1000 A: 0.1 A</td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">&gt; 1000 A: 1 A</td>
<td valign="top">± (4% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC V%</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">0.1%</td>
<td valign="top">± (2% + 10 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">0.1%</td>
<td valign="top">± (4% + 20 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Absolute harmonic</strong></td>
<td valign="top">0 &#8230; 20%</td>
<td valign="top">0.1%</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"><strong>distortion</strong></td>
<td valign="top">20.1 &#8230; 100%</td>
<td valign="top">0.1%</td>
<td valign="top">± (6% + 10 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Temperature type K</strong></td>
<td valign="top">-100 &#8230; 199.9°C / -148 &#8230; 391.8°F</td>
<td valign="top">0.1°C / 0.18°F</td>
<td valign="top">± (1% + 1°C / 1.8°F)</td>
</tr>
<tr>
<td valign="top"><strong>thermocouple</strong></td>
<td valign="top">200 &#8230; 1300°C / 392 &#8230; 2372°F</td>
<td valign="top">1°C / 1.8°F</td>
<td valign="top">± (1% + 2°C / 3.6°F)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">Graphic LCD</td>
</tr>
<tr>
<td valign="top">AC V input impedance</td>
<td colspan="3" valign="top">10 MOhm</td>
</tr>
<tr>
<td valign="top">Frequency range</td>
<td colspan="3" valign="top">40 Hz &#8230; 1 kHz</td>
</tr>
<tr>
<td valign="top">Current Probe</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Calibrated frequency</td>
<td colspan="3" valign="top">45 &#8230; 65 Hz</td>
</tr>
<tr>
<td valign="top">Current Probe</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Overload protection</td>
<td colspan="3" valign="top">AC V: 720V RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">AC A: 2100 A</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td colspan="3" valign="top">Micro SD card</td>
</tr>
<tr>
<td valign="top">Refresh rate</td>
<td colspan="3" valign="top">1 second</td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Storage rate</td>
<td colspan="3" valign="top">2 &#8230; 7200s</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Storage format</td>
<td colspan="3" valign="top">XLS</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td colspan="3" valign="top">Serial interface for live presentation to PC</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">(SOFT-LUT-USB is required)</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">2 x 1.5V AA battery</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">9V / 800-mA power supply</td>
</tr>
<tr>
<td valign="top">Current consumption</td>
<td colspan="3" valign="top">60-mA DC</td>
</tr>
<tr>
<td valign="top">Clamp opening</td>
<td colspan="3" valign="top">50 mm</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">About 595 g / 1.3 lbs</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">280 x 106 x 47 mm / 11 x 4.2 x 1.9 in</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-GPA 50-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12638</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-123-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:20:04 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12636</guid>

					<description><![CDATA[<p><strong>PCE-123-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-123-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Electrical tester</strong><strong> PCE-123-ICA<br />
Digital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals / Control signals as well as frequencies and temperature / Incl. ISO Calibration Certificate<br />
</strong></p>
<p>The PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.</p>
<p>The calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.</p>
<div>
<div> &#8211; 4 to 20mA (1kΩ, 24V power)<br />
&#8211; 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V<br />
&#8211; Type-K, J, E, T temperature thermocouple sensors (°C or °F)<br />
&#8211; Frequency range 1 to 62,500Hz<br />
&#8211; Basic accuracy 0.025 %<br />
&#8211; Easy operation via keypad<br />
&#8211; Automatic ramp function<br />
&#8211; Selectable between 0 to 20mA/ 0 to 24mA<br />
&#8211; Input 0 to 100% (mA, mV, V )<br />
&#8211; Alarm beep &#8216;open&#8217; (mA) or &#8216;short circuit&#8217; (mV, V)<br />
&#8211; <strong>Incl. ISO Calibration Certificate</strong></div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>mA DC current<br />
(maximum load at 1kΩ, powered by 24V)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>4 to 20-mA / 0 to 20-mA / 0 to 24-mA</td>
</tr>
<tr>
<td>Resolution</td>
<td>1µA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.025% ±3µA</td>
</tr>
<tr>
<td>Alert</td>
<td>Beeps when there is a short circuit or ouput current &gt;1mA .</td>
</tr>
<tr>
<td colspan="2"><strong>mV current, V DC<br />
(power 1-mA)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>0 to 100.00 mV<br />
0 to 10.000 V<br />
0 to 1.0000 V</td>
</tr>
<tr>
<td>Resolution</td>
<td>10 µV<br />
1 mV<br />
1.0000 V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.05% ±30 µV<br />
± 0.05% ±3 mV<br />
± 0.05% ±300 µV</td>
</tr>
<tr>
<td>Alert</td>
<td>Beeps when there is a short circuit or ouput current &gt;10mV.</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature sensor thermocouple type-K, J, E, T<br />
(1 kΩ min.)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>K: -200 &#8230; 0°C / -328 &#8230; 32°F and 0 &#8230; 1370°C / 32 &#8230; 2498°F<br />
J: -100 &#8230; 0°C / -148 &#8230; 32°F and 0 &#8230; 760°C / 32 &#8230; 1400°F<br />
E: -10 &#8230; 0°C / 14 &#8230; 32°F and 0 &#8230; 700°C / 32 &#8230; 1292°F<br />
T: -200 &#8230; 0°C / -328 &#8230; 32°F and T: 0 &#8230; 400°C / 32 &#8230; 752°F</td>
</tr>
<tr>
<td>Resolution</td>
<td>1°C / 1.8°F (across entire range)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>K: ± 1.1°C / 2°F  and ± 0.8°C /  1.4°F<br />
J:  ± 0.9°C / 1.6°F and ± 0.7°C / 1.3°F<br />
E: ± 0.9°C / 1.6°F and ± 0.7°C / 1.3°F<br />
T:  ± 1.0°C / 1.8°F and ± 0.8°C / 1.4°F</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>1 to 125Hz and 126 to 62.5kHz</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.04Hz</td>
</tr>
<tr>
<td>Selection</td>
<td>604 frequencies</td>
</tr>
<tr>
<td colspan="2"><strong>General characteristics</strong></td>
</tr>
<tr>
<td>Display</td>
<td>5 position LCD</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F, &lt;85% r.h.</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60°C / -4 &#8230; 140 °F; &lt;85% r.h.</td>
</tr>
<tr>
<td>Power</td>
<td>1 9V battery or 6 x 1.5V batteries</td>
</tr>
<tr>
<td>Consumption</td>
<td>60-mA to 180-mA (depending on output)</td>
</tr>
<tr>
<td>Battery indicator</td>
<td>5.5V for 150-mA</td>
</tr>
<tr>
<td>Dimensions</td>
<td>88 x 168 x 26 mm / 3.4 x 6.6 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>330 g / 11.6 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-123-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12636</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-GPA 50</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:14:32 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12634</guid>

					<description><![CDATA[<p><strong>PCE-GPA 50</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50/">Electrical Tester PCE-GPA 50</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Electrical tester</strong><strong> PCE-GPA 50<br />
Current clamp up to 2000 A / TRMS measurement / Power measurement / Harmonic analysis / Graphic display with lighting / Data storage / Mains and battery operation</strong></div>
<div></div>
<div>The PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.</div>
<div></div>
<div>In addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.</div>
<div></div>
<div>&#8211; Graphic display<br />
&#8211; Data logger on Micro-SD card<br />
&#8211; Measurement for 1 and 3 phases<br />
&#8211; Temperature measurement with thermocouple<br />
&#8211; Voltage measurement 10V &#8230; 600V AC RMS<br />
&#8211; Current measurement 5 &#8230; 2000 A AC RMS<br />
&#8211; Current clamp opening 50 mm<br />
&#8211; Harmonic distortion up to the 50th order</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="0"><strong><span>Type of measurement</span></strong></td>
<td colspan="3" valign="top" width="0"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong><span>AC voltage AC V    </span></strong></p>
</td>
<td valign="top"><strong><span>Measuring range      </span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>10 &#8230; 600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.5% &#8230; 3 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Peak to peak</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (5% &#8230; 30 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong><span>AC AC A</span></strong></p>
</td>
<td valign="top"><span>5 &#8230; 2000 A</span></td>
<td valign="top"><span>&lt; 100 A: 0.01 A    </span></td>
<td valign="top"><span>&lt; 200 A: ± (1% + 0.5 A)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"><span>&lt; 1000 A: 0.1 A</span></td>
<td valign="top"><span>&gt; 200 A: ± (1% + 5 A)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Peak to peak</span></td>
<td valign="top"><span>&gt; 1000 A: 1 A</span></td>
<td valign="top"><span>± (5% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Power factor (PF)</span></strong></td>
<td valign="top"><span>0 &#8230; 1</span></td>
<td valign="top"><span>0.001</span></td>
<td valign="top"><span>± 0.04</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Phase angle</span></strong></td>
<td valign="top"><span>-180° &#8230; 180°</span></td>
<td valign="top"><span>0.1°</span></td>
<td valign="top"><span>± 1° x PF</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency</span></strong></td>
<td valign="top"><span>45 &#8230; 65 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 0.2 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Active, blind &amp;</span></strong></td>
<td valign="top"><span>0 &#8230; 9,999 m</span></td>
<td valign="top"><span>0.1 &#8230; 0.001 M</span></td>
<td valign="top"><span>± (1.5% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>apparent power</span></strong></td>
<td valign="top"><span>(W / VA / VAR)</span></td>
<td valign="top"><span>(W / VA / VAR)</span></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC V</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (4% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC A</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>&lt; 100 A: 0.01 A</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Alternating current</span></strong></td>
<td valign="top"></td>
<td valign="top"><span>&lt; 1000 A: 0.1 A</span></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>&gt; 1000 A: 1 A</span></td>
<td valign="top"><span>± (4% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC V%</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (4% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Absolute harmonic</span></strong></td>
<td valign="top"><span>0 &#8230; 20%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>distortion</span></strong></td>
<td valign="top"><span>20.1 &#8230; 100%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (6% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Temperature type K</span></strong></td>
<td valign="top"><span>-100 &#8230; 199.9°C / -148 &#8230; 391.8</span>°F</td>
<td valign="top"><span>0.1°C / 0.18</span>°F</td>
<td valign="top"><span>± (1% + 1°C / 1.8°F)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>thermocouple</span></strong></td>
<td valign="top"><span>200 &#8230; 1300°C / 392 &#8230; 2372</span>°F</td>
<td valign="top"><span>1°C / 1.8</span>°F</td>
<td valign="top"><span>± (1% + 2°C / 3.6°F)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="3" valign="top"><span>Graphic LCD</span></td>
</tr>
<tr>
<td valign="top"><span>AC V input impedance        </span></td>
<td colspan="3" valign="top"><span>10 MOhm</span></td>
</tr>
<tr>
<td valign="top"><span>Frequency range</span></td>
<td colspan="3" valign="top"><span>40 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Current Probe</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Calibrated frequency</span></td>
<td colspan="3" valign="top"><span>45 &#8230; 65 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Current Probe</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Overload protection</span></td>
<td colspan="3" valign="top"><span>AC V: 720V RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>AC A: 2100 A</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="3" valign="top"><span>Micro SD card</span></td>
</tr>
<tr>
<td valign="top"><span>Refresh rate</span></td>
<td colspan="3" valign="top"><span>1 second</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Storage rate</span></td>
<td colspan="3" valign="top"><span>2 &#8230; 7200s</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Storage format</span></td>
<td colspan="3" valign="top"><span>XLS</span></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="3" valign="top"><span>Serial interface for live presentation to PC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>(SOFT-LUT-USB is required)</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="3" valign="top"><span>2 x 1.5V AA battery</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>9V / 800-mA power supply</span></td>
</tr>
<tr>
<td valign="top"><span>Current consumption</span></td>
<td colspan="3" valign="top"><span>60-mA DC</span></td>
</tr>
<tr>
<td valign="top"><span>Jaw Capacity</span></td>
<td colspan="3" valign="top"><span>50 mm</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="3" valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</span></td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top"><span>About 595 g / 1.3 lbs</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="3" valign="top"><span>280 x 106 x 47 mm / 11 x 4.2 x 1.9 in</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50/">Electrical Tester PCE-GPA 50</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-gpa-50/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12634</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-BDM 20-ICA Incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:12:31 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12630</guid>

					<description><![CDATA[<p><strong>PCE-BDM 20-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-BDM 20-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Electrical Tester PCE-BDM 20-ICA Incl. ISO Calibration Certificate</strong></div>
<div style="text-align: center"><strong>Digital multimeter for the stationary workplace / Various measurement functions /  High measuring ranges / PASS / FAIL function for component testing / HOLD function / Connection of two thermocouples simultaneously / Software / USB interface</strong></div>
<div></div>
<div>The digital multimeter is a multimeter for a stationary workplace. In addition to measuring current, voltage and resistance, the digital multimeter can also use two thermocouples to measure the temperature and also determine the conductivity. So the digital multimeter can perform a variety of different measurement tasks. A direct connection to a PC can be established via the USB interface on the back of the digital multimeter. The software from the digital multimeter can then be used to carry out live analyzes using graphics and tables.</div>
<div></div>
<div>Another special feature of the digital multimeter is the PASS / FAIL function. With this function, target ranges for the measured values ​​can be set for each measuring function. Depending on the actual measured value, a &#8220;PASS&#8221; (passed) or a &#8220;FAIL&#8221; (failed) is then shown on the display by the digital multimeter. The digital multimeter is therefore used, for example, in quality control. With the help of the adjustable handle, the digital multimeter can be adjusted for ergonomic use by the operator. The handle of the digital multimeter can also be used to change the workplace. The housing of the digital multimeter has a rubberized edge protection, which prevents damage.</div>
<div></div>
<div>&#8211; Table multimeter with reinforced housing<br />
&#8211; USB interface for PC connection<br />
&#8211; PASS / FAIL function for quality control<br />
&#8211; extensive measuring functions<br />
&#8211; Relate the measured value<br />
&#8211; Measured value with bar graph display<br />
&#8211; Incl. ISO calibration certificate</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong><span>AC voltage</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (0.6% 60 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (0.4% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.6% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>DC voltage</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (0.025% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (0.003% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.003% + 5 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>AC voltage + DC voltage</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (1.2% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Alternating current</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.6% + 40 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.6% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.6% + 40 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.6% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (1% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø 10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>When measuring almost 20 A, the measurement time should not be longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Direct current</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.8% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.8% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.8% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.15% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (0.5% + 10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>A measurement of almost 20 A should not take longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>AC + DC</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.8% + 40 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.8% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.8% + 40 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.8% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (1.2% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>A measurement of almost 20 A should not take longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Resistance</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.01Ω</span></td>
<td valign="top"><span>In REL mode: ± (0.05% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 kΩ</span></td>
<td valign="top"><span>0.0001 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 kΩ</span></td>
<td valign="top"><span>0.001 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 kΩ</span></td>
<td valign="top"><span>0.01 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 MΩ</span></td>
<td valign="top"><span>0.0001 MΩ</span></td>
<td valign="top"><span>± (0.3% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 MΩ</span></td>
<td valign="top"><span>0.001 MΩ</span></td>
<td valign="top"><span>± (2% +10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000 V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>With a measuring range of 60 MΩ the ambient humidity should be &lt; 50%.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Conductivity</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 nS</span></td>
<td valign="top"><span>0.01 nS</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The ambient humidity for the measuring range should be &lt; 50%.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Capacity measurement</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6 nF</span></td>
<td valign="top"><span>0.001 nF</span></td>
<td valign="top"><span>± (3% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 nF</span></td>
<td valign="top"><span>0.01 nF</span></td>
<td valign="top"><span>± (2.5% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 nF</span></td>
<td valign="top"><span>0.1 nF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 μF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 μF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 μF</span></td>
<td valign="top"><span>0.1 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 mF</span></td>
<td valign="top"><span>1 μF</span></td>
<td valign="top"><span>± (5% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 mF</span></td>
<td valign="top"><span>10 μF</span></td>
<td valign="top"><span>for reference only</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000 V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Temperature</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>-40 &#8230; 40°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± (2.0% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40 &#8230; 400°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± (1.0% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>100 &#8230; 1000°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± 2.5%</span></td>
</tr>
<tr>
<td valign="top"><span>-40 &#8230; 104°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± (2.5% + 50 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>104 &#8230; 752°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± (1.5% + 50 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>752 &#8230; 1832°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± 2.5%</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Two-channel temperature measurement</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Temperature sensor: Type K only applies to the measurement of temperatures below 230°C / 446</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Frequency measurement</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 Hz</span></td>
<td valign="top"><span>0.001 Hz</span></td>
<td valign="top"><span>± (0.02% + 8 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 kHz</span></td>
<td valign="top"><span>0.0001 kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 kHz</span></td>
<td valign="top"><span>0.00 1kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 kHz</span></td>
<td valign="top"><span>0.01 kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 MHz</span></td>
<td valign="top"><span>0.0001 MHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 MHz</span></td>
<td valign="top"><span>0.00 1MHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input amplitude: 10 Hz &#8230; 30 MHz: 600 mV &lt;a &lt;30 Vrm,&gt; 30 MHz: not specified</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Duty cycle</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>10 &#8230; 90% @</span></td>
<td valign="top"><span>0.01%</span></td>
<td valign="top"><span>± (1.2% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>(10Hz &#8230; 2kHz)</span></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Rise time: &lt;1 µs, the signal is centered on the trigger level</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Pulse width</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>250 mS</span></td>
<td valign="top"><span>0.001 &#8230; 0.1 mS</span></td>
<td valign="top"><span>± (1.2% + 30 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Rise time: &lt; 1 µs, the signal is centered on the trigger level</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 Hz &#8230; 200 kHz: pulse width &gt; 2 µs</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The pulse range is limited by the frequency of the signal</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Continuity test</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Functional description</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.01 Ω</span></td>
<td colspan="2" valign="top"><span>Short circuit alarm: from &lt; 10 Ω, alarm switches off from &gt; 50 Ω</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Diode test</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0.0001V</span></td>
<td colspan="2" valign="top"><span>The open circuit voltage is approx. 3V and the measurable voltage drop</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>of the PN transition is &lt; 3V A continuous beep</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>indicates the short circuit of the PN junction. The typical tension</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>of the silicon PN junction is between 0.5 &#8230; 0.8V.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Further specifications on accuracy can be found in the operating instructions</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Further specification</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="2" valign="top"><span>USB interface</span></td>
</tr>
<tr>
<td valign="top"><span>Supply voltage</span></td>
<td colspan="2" valign="top"><span>100 &#8230; 240V adjustable</span></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions  </span></td>
<td colspan="2" valign="top"><span>23°C / 73.4°F ± 5°C / 41°F, &lt; 75% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>310 x 240 x 120 mm / 12.2 x 9.4 x 4.7 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>Approx. 3713 g / 8.2 lbs</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20-ica-incl-iso-calibration-certificate/">Electrical Tester PCE-BDM 20-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12630</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-123</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:10:06 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12622</guid>

					<description><![CDATA[<p><strong>PCE-123</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123/">Electrical Tester PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Digital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals / control signals as well as frequencies and temperature</strong></p>
<p>The PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.</p>
<p>The calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.</p>
<div>
<div> &#8211; 4 to 20mA (1kΩ, 24V power)<br />
&#8211; 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V<br />
&#8211; Type-K, J, E, T temperature thermocouple sensors (°C or °F)<br />
&#8211; Frequency range 1 to 62,500Hz<br />
&#8211; Basic accuracy 0.025 %<br />
&#8211; Easy operation via keypad<br />
&#8211; Automatic ramp function<br />
&#8211; Selectable between 0 to 20mA/ 0 to 24mA<br />
&#8211; Input 0 to 100% (mA, mV, V )<br />
&#8211; Alarm beep &#8216;open&#8217; (mA) or &#8216;short circuit&#8217; (mV, V)</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td colspan="2"><strong>mA DC current<br />
(maximum load at 1kΩ, powered by 24V)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>4 to 20mA / 0 to 20mA / 0 to 24mA</td>
</tr>
<tr>
<td>Resolution</td>
<td>1µA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.025% ±3µA</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;1mA .</td>
</tr>
<tr>
<td colspan="2"><strong>mV current, V DC<br />
(power 1mA)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>0 to 100.00 mV<br />
0 to 10.000 V<br />
0 to 1.0000 V</td>
</tr>
<tr>
<td>Resolution</td>
<td>10 µV<br />
1 mV<br />
1.0000 V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.05% ±30 µV<br />
± 0.05% ±3 mV<br />
± 0.05% ±300 µV</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;10mV.</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature sensor thermocouple type-K, J, E, T<br />
(1 kΩ min.)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>K: -200 &#8230; 0 °C / -328 &#8230; 32 °F and 0 &#8230; 1370 °C / 32 &#8230; 2498 °F<br />
J: -100 &#8230; 0 °C / -148 &#8230; 32 °F and 0 &#8230; 760 °C / 32 &#8230; 1400 °F<br />
E: -10 &#8230; 0 °C / 14 &#8230; 32 °F and 0 &#8230; 700°C / 32 &#8230; 1292 °F<br />
T: -200 &#8230; 0°C / -328 &#8230; 32 °F and T: 0 &#8230; 400 °C / 32 &#8230; 752 °F</td>
</tr>
<tr>
<td>Resolution</td>
<td>1°C (across entire range)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>K: ±1.1°C and ±0.8°C<br />
J:  ±0.9°C and ±0.7°C<br />
E: ±0.9°C and ±0.7°C<br />
T:  ±1.0°C and ±0.8°C</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>1 to 125Hz and 126 to 62.5kHz</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.04Hz</td>
</tr>
<tr>
<td>Selection</td>
<td>604 frequencies</td>
</tr>
<tr>
<td colspan="2"><strong>General characteristics</strong></td>
</tr>
<tr>
<td>Display</td>
<td>5 position LCD</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50 °C / 32 &#8230; 122 °F &lt;85% r.h.</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60 °C / -4 &#8230; 140 °F; &lt;85% r.h.</td>
</tr>
<tr>
<td>Power</td>
<td>1 9V battery or 6 x 1.5V batteries</td>
</tr>
<tr>
<td>Consumption</td>
<td>60mA to 180mA (depending on output)</td>
</tr>
<tr>
<td>Battery indicator</td>
<td>5.5V for 150mA</td>
</tr>
<tr>
<td>Dimensions</td>
<td>88 x 168 x 26mm / 3.4 x 6.6 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>330 g / 11.6 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123/">Electrical Tester PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-123/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12622</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-IT 120</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-it-120/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-it-120/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 02:01:13 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12612</guid>

					<description><![CDATA[<p><strong>PCE-IT 120</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-it-120/">Electrical Tester PCE-IT 120</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Electrical tester</strong><strong> PCE-IT 120<br />
&#8220;Auto Ranging&#8221; insulation tester up to 8 GΩ in a compact housing</strong></div>
<div></div>
<div>The insulation measuring device PCE-IT 120 detects insulation resistance up to max. 8 GΩ (with auxiliary voltages of 250, 500 and 1000V). In addition, this insulation measuring device offers a measuring function for DC and AC voltages up to max. 950V DC and 700V AC as well as resistors up to max. 2 kΩ. A continuity tester with beep is integrated. Furthermore, the insulation meter can be used to check the polarization index and the dielectric ratio.</div>
<div></div>
<div>The measured values ​​can be recorded at the touch of a button in the OLED display of the insulation tester. The device complies with DIN 57 411 part 1 / VDE 0411 part 1, protective measures for electronic measuring instruments (IEC1010-1) and DIN VDE 0413 (insulation tester). The insulation tester is always factory-calibrated and can be equipped with an ISO calibration certificate (at first order or at a recertification, eg annually).</div>
<div></div>
<div>Definition of the insulation resistance: The insulation resistance is the resistance in ohms for conductors, cables and electrical installations. It is therefore of great importance for the preventive protection of persons against electric shock or the avoidance of property damage by flowing leakage currents. Insulation resistance measurements are used to check and assess the condition of the insulation (conductor and housing).</div>
<div></div>
<div>&#8211; OLED display<br />
&#8211; Automatic polarity display<br />
&#8211; Automatic range selection<br />
&#8211; Automatic zeroing<br />
&#8211; Discharge beeper for insulation measurements<br />
&#8211; Overload protection during continuity test<br />
&#8211; Safety function, the voltage is held only 10 seconds (can be deactivated)<br />
&#8211; Hold function<br />
&#8211; PI and DAR test</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measuring ranges</span></td>
<td valign="top"><span>2 GΩ / 250V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 GΩ / 500V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>8 GΩ / 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>ACV: 0 &#8230; 950V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>DCV: 0 &#8230; 700V</span></td>
</tr>
<tr>
<td valign="top"><span>Resistance / passage      </span></td>
<td valign="top"><span>0.01 &#8230; 1999 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>Isolation: 1/10/100 MΩ</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>ACV: 1V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>DCV: 1V</span></td>
</tr>
<tr>
<td valign="top"><span>Resistance / passage</span></td>
<td valign="top"><span>0.01 / 0.1 / 1 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td valign="top"><span>Isolation: ± 3%</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>ACV: ± 1.5%</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>DCV: ± 1.5%</span></td>
</tr>
<tr>
<td valign="top"><span>Resistance / passage</span></td>
<td valign="top"><span>± 2.0%</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>DC test voltage</span></td>
<td valign="top"><span>250/500 / 1000V</span></td>
</tr>
<tr>
<td valign="top"><span>Short circuit current</span></td>
<td valign="top"><span>1.1-mA</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td valign="top"><span>2-line 16-fold OLED display</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td valign="top"><span>8 x 1.5V AA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td valign="top"><span>175 x 85 x 75 mm / 6.9 x 3.3 x 3 in </span></td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top"><span>About 655 g / 1.4 lbs</span></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions</span></td>
<td valign="top"><span>0 &#8230; 40°C / 32 &#8230; 104</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Degree of protection / standardization      </span></td>
<td valign="top"><span>IEC 1010-1, 700V CAT III</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-it-120/">Electrical Tester PCE-IT 120</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-it-120/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12612</post-id>	</item>
		<item>
		<title>Electrical Tester PCE-BDM 20</title>
		<link>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20/</link>
					<comments>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 10 Feb 2021 01:36:17 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12605</guid>

					<description><![CDATA[<p><strong>PCE-BDM 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20/">Electrical Tester PCE-BDM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Electrical tester</strong><strong> PCE-BDM 20<br />
Digital multimeter for the stationary workplace / Various measurement functions /  High measuring ranges / PASS / FAIL function for component testing / HOLD function / Connection of two thermocouples simultaneously / Software / USB interface</strong></div>
<div></div>
<div>The digital multimeter is a multimeter for a stationary workplace. In addition to measuring current, voltage and resistance, the digital multimeter can also use two thermocouples to measure the temperature and also determine the conductivity. So the digital multimeter can perform a variety of different measurement tasks. A direct connection to a PC can be established via the USB interface on the back of the digital multimeter. The software from the digital multimeter can then be used to carry out live analyzes using graphics and tables.</div>
<div></div>
<div>Another special feature of the digital multimeter is the PASS / FAIL function. With this function, target ranges for the measured values ​​can be set for each measuring function. Depending on the actual measured value, a &#8220;PASS&#8221; (passed) or a &#8220;FAIL&#8221; (failed) is then shown on the display by the digital multimeter. The digital multimeter is therefore used, for example, in quality control. With the help of the adjustable handle, the digital multimeter can be adjusted for ergonomic use by the operator. The handle of the digital multimeter can also be used to change the workplace. The housing of the digital multimeter has a rubberized edge protection, which prevents damage.</div>
<div></div>
<div>&#8211; Table multimeter with reinforced housing<br />
&#8211; USB interface for PC connection<br />
&#8211; PASS / FAIL function for quality control<br />
&#8211; extensive measuring functions<br />
&#8211; Relate the measured value<br />
&#8211; Measured value with bar graph display</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong><span>AC voltage</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (0.6% 60 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (0.3% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (0.4% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.6% 30 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>DC voltage</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (0.025% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (0.025% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (0.003% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.003% + 5 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>AC voltage + DC voltage</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 mV</span></td>
<td valign="top"><span>0.001 mV</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600 mV</span></td>
<td valign="top"><span>0.01 mV</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.0001V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± (1% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (1.2% + 80 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance:&gt; 10MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Alternating current</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.6% + 40 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.6% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.6% + 40 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.6% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (1% + 20 digits) @ 45 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø 10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>When measuring almost 20 A, the measurement time should not be longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Direct current</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.8% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.8% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.8% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.15% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (0.5% + 10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>A measurement of almost 20 A should not take longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>AC + DC</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 µA</span></td>
<td valign="top"><span>0.01 µA</span></td>
<td valign="top"><span>± (0.8% + 40 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>6000 µA</span></td>
<td valign="top"><span>0.1 µA</span></td>
<td valign="top"><span>± (0.8% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>60-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (0.8% + 40 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>600-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (0.8% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>10 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (1.2% + 20 digits) @ 50 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Display: True RMS in the measuring range of 10 &#8230; 100% of the respective measuring range</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 A measurement: F 11 A 1000V Ø10 x 38 mm</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>A measurement of almost 20 A should not take longer than 30 seconds.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>After the measurement, the measuring device must rest for approx. 10 minutes.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Resistance</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.01Ω</span></td>
<td valign="top"><span>In REL mode: ± (0.05% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 kΩ</span></td>
<td valign="top"><span>0.0001 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 kΩ</span></td>
<td valign="top"><span>0.001 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 kΩ</span></td>
<td valign="top"><span>0.01 kΩ</span></td>
<td valign="top"><span>± (0.05% + 2 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 MΩ</span></td>
<td valign="top"><span>0.0001 MΩ</span></td>
<td valign="top"><span>± (0.3% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 MΩ</span></td>
<td valign="top"><span>0.001 MΩ</span></td>
<td valign="top"><span>± (2% +10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000 V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>With a measuring range of 60 MΩ the ambient humidity should be &lt; 50%.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Conductivity</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 nS</span></td>
<td valign="top"><span>0.01 nS</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The ambient humidity for the measuring range should be &lt; 50%.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Capacity measurement</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6 nF</span></td>
<td valign="top"><span>0.001 nF</span></td>
<td valign="top"><span>± (3% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 nF</span></td>
<td valign="top"><span>0.01 nF</span></td>
<td valign="top"><span>± (2.5% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 nF</span></td>
<td valign="top"><span>0.1 nF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 μF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 μF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 μF</span></td>
<td valign="top"><span>0.1 μF</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 mF</span></td>
<td valign="top"><span>1 μF</span></td>
<td valign="top"><span>± (5% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 mF</span></td>
<td valign="top"><span>10 μF</span></td>
<td valign="top"><span>for reference only</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000 V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Temperature</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>-40 &#8230; 40°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± (2.0% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40 &#8230; 400°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± (1.0% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>100 &#8230; 1000°C</span></td>
<td valign="top"><span>1°C</span></td>
<td valign="top"><span>± 2.5%</span></td>
</tr>
<tr>
<td valign="top"><span>-40 &#8230; 104°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± (2.5% + 50 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>104 &#8230; 752°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± (1.5% + 50 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>752 &#8230; 1832°F</span></td>
<td valign="top"><span>1.8°F</span></td>
<td valign="top"><span>± 2.5%</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Two-channel temperature measurement</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Temperature sensor: Type K only applies to the measurement of temperatures below 230°C / 446</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Frequency measurement</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 Hz</span></td>
<td valign="top"><span>0.001 Hz</span></td>
<td valign="top"><span>± (0.02% + 8 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 kHz</span></td>
<td valign="top"><span>0.0001 kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 kHz</span></td>
<td valign="top"><span>0.00 1kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>600 kHz</span></td>
<td valign="top"><span>0.01 kHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>6 MHz</span></td>
<td valign="top"><span>0.0001 MHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>60 MHz</span></td>
<td valign="top"><span>0.00 1MHz</span></td>
<td valign="top"><span>± (0.01% + 5 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input amplitude: 10 Hz &#8230; 30 MHz: 600 mV &lt;a &lt;30 Vrm,&gt; 30 MHz: not specified</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Duty cycle</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>10 &#8230; 90% @</span></td>
<td valign="top"><span>0.01%</span></td>
<td valign="top"><span>± (1.2% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>(10Hz &#8230; 2kHz)</span></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Rise time: &lt;1 µs, the signal is centered on the trigger level</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><strong><span>Pulse width</span></strong></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>250 mS</span></td>
<td valign="top"><span>0.001 &#8230; 0.1 mS</span></td>
<td valign="top"><span>± (1.2% + 30 digits)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Rise time: &lt; 1 µs, the signal is centered on the trigger level</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>10 Hz &#8230; 200 kHz: pulse width &gt; 2 µs</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The pulse range is limited by the frequency of the signal</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Continuity test</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td colspan="2" valign="top"><strong><span>Functional description</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.01 Ω</span></td>
<td colspan="2" valign="top"><span>Short circuit alarm: from &lt; 10 Ω, alarm switches off from &gt; 50 Ω</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Diode test</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>0.0001V</span></td>
<td colspan="2" valign="top"><span>The open circuit voltage is approx. 3V and the measurable voltage drop</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>of the PN transition is &lt; 3V A continuous beep</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>indicates the short circuit of the PN junction. The typical tension</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>of the silicon PN junction is between 0.5 &#8230; 0.8V.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Surge protection: 1000V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Further specifications on accuracy can be found in the operating instructions</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Further specification</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="2" valign="top"><span>USB interface</span></td>
</tr>
<tr>
<td valign="top"><span>Supply voltage</span></td>
<td colspan="2" valign="top"><span>100 &#8230; 240V adjustable</span></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions  </span></td>
<td colspan="2" valign="top"><span>23°C / 73.4°F ± 5°C / 41°F, &lt; 75% RH</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>310 x 240 x 120 mm / 12.2 x 9.4 x 4.7 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>Approx. 3713 g / 8.2 lbs</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20/">Electrical Tester PCE-BDM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/electrical-tester/electrical-tester-pce-bdm-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12605</post-id>	</item>
	</channel>
</rss>
