<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Environmental Tester - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/environmental-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/environmental-tester/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 29 Nov 2022 16:51:34 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Environmental Tester - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/environmental-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Environmental Tester PCE-HT 420IoT</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-ht-420iot/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-ht-420iot/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:22:11 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13206</guid>

					<description><![CDATA[<p><strong>PCE-HT 420IoT</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-ht-420iot/">Environmental Tester PCE-HT 420IoT</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental Tester PCE-HT 420<br />
Data logger for temperature and humidity / MQTT / Power supply unit or PoE (Power over Ethernet) / LC display / Visualization in web browser / 8 GB memory</strong></div>
<div></div>
<div>The environmental tester PCE-HT 420 is used to monitor the temperature and humidity. The datalogger is equipped with a network interface. This makes the PCE-HT 420 data logger an ideal solution for objects in which the measurement data must be continuously recorded and monitored. The datalogger continuously stores the measured values ​​on its internal memory. This is read out via browser or FTP client. The web browser also makes all the settings on the datalogger. No additional software is needed. The architecture of the data logger allows up to 10 users to dial in to the datalogger at the same time. Different access levels prevent unauthorized users from making settings to the datalogger.</div>
<div></div>
<div>In addition to storing the measured values, the PCE-HT 420 data logger can also alert the user to an alarm when the limit value is exceeded. Furthermore, various users can be notified of this alarm via email.</div>
<div></div>
<div>The data logger PCE-HT 420 measures and calculates the following climatic variables:</div>
<div>&#8211; Temperature<br />
&#8211; Relative humidity</div>
<div>&#8211; Dew point</div>
<div>&#8211; Absolute humidity, ie amount of water vapor (in grams) per m³ of atmosphere at certain temperature</div>
<div>&#8211; Cooling limit temperature</div>
<div>&#8211; Saturated vapor pressure, ie pressure, at which gas at the specified temperature in equilibrium with liquid (equilibrium between evaporation and condensation)</div>
<div>&#8211; Enthalpy (energy content)</div>
<div></div>
<div>The data logger is supplied via an external power supply unit or via Power over Ethernet. The built-in FTP server provides quick and easy access to archive files using an Internet browser or from the interface of another FTP client. The DHCP protocol allows you to automatically configure the datalogger on the computer network. Furthermore, the data logger supports the Modbus TCP / IP protocol, so that the PCE-HT 420 can also be integrated in machines. All these features make the PCE-HT 420 Datalogger an important instrument wherever indoor climate needs to be monitored.</div>
<div></div>
<div>&#8211; Temperature and humidity sensor<br />
&#8211; Ethernet interface with MQTT function<br />
&#8211; LCD display<br />
&#8211; Alarms via email<br />
&#8211; Audible warning sound<br />
&#8211; 8 GB memory</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td>Measuring range humidity</td>
<td>0 &#8230; 95% rh (non-condensing)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 3% between 10 &#8230; 90%<br />
± 5% elsewhere</td>
</tr>
<tr>
<td>Hysteresis</td>
<td>± 1% RH</td>
</tr>
<tr>
<td>Measuring range temperature</td>
<td>-20 &#8230; 60°C / -4 &#8230; 140°F</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.6°C / 1.08°F in the range of 10 &#8230; 40°C / 10 &#8230; 104°F; ± 1.0°C / 1.8°F elsewhere</td>
</tr>
<tr>
<td>Calculated sizes</td>
<td>Absolute humidity g/m³<br />
Dew point temperature °C / °F</td>
</tr>
<tr>
<td>Storage</td>
<td>Internal ring buffer: 4 MB*<br />
Internal hard disk 8 GB</p>
<p>*The measurement data from the internal memory is automatically transferred to the permanent memory</td>
</tr>
<tr>
<td>Interface</td>
<td>Ethernet 10/100 Base / T</td>
</tr>
<tr>
<td>Number of connections</td>
<td>Max. 10 at the same time</td>
</tr>
<tr>
<td>Protocol</td>
<td>DHCP<br />
FTP<br />
SMTP<br />
Modbus TCP/IP<br />
<strong>MQTT</strong></td>
</tr>
<tr>
<td>Power supply</td>
<td>DC power supply 6V / 1 A PoE IEEE 802.3af</td>
</tr>
<tr>
<td>Input</td>
<td>&lt;2VA</td>
</tr>
<tr>
<td>Warm-up time</td>
<td>15 minutes</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>-20 &#8230; 60°C / 95% rh</td>
</tr>
<tr>
<td>Degree of protection</td>
<td>IP20</td>
</tr>
<tr>
<td>Assembly</td>
<td>Rear mounting hole for wall mounting<br />
Sensor downwards</td>
</tr>
<tr>
<td>Weight</td>
<td>300 g / &lt; 1 lb</td>
</tr>
<tr>
<td>Dimensions</td>
<td>120 x 80 x 25 mm / 4.7 x 3.1 x 1 in</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-ht-420iot/">Environmental Tester PCE-HT 420IoT</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-ht-420iot/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13206</post-id>	</item>
		<item>
		<title>Environmental Tester PCE-THB 40-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-thb-40-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-thb-40-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:19:44 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13204</guid>

					<description><![CDATA[<p><strong>PCE-THB 40-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-thb-40-ica-incl-iso-calibration-certificate/">Environmental Tester PCE-THB 40-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Environmental Tester with SD memory card</strong><strong> &amp; ISO Calibration Certificate</strong><br />
<strong>(max. 16 GB SDHC) / large LCD display / different units can be selected / battery or </strong><strong>mains operation (optional) possible</strong></div>
<p>The environmental tester records the air temperature as well as the relative humidity and the barometric pressure and saves them internally on an SD card. The compact device with a large memory (up to max. 16 GB SDHC card) is primarily used for long-term registration in the food sector (refrigerated counters in department stores, refrigerated transports, warehouses) and for measurement and recording in industry (heating and cooling processes, machine temperatures, product storage). The current measured value is shown directly on the LCD display and is also stored in the data memory so that the value can either be read off directly or the values ​​stored on the SD card can be transferred to a PC or laptop as desired and evaluated graphically as a progression curve.</p>
<p>The values ​​recorded in the data logger function can of course also be transferred back to the PC and evaluated (.xls file on the SD card). You can also check the columns of numbers for outliers and, in the case of the food industry, quickly see whether and, if so, how long the cold chain was interrupted. The internal real-time clock with date allows the user to precisely assign the events. The measuring rate is freely adjustable. The electronics of the data logger are protected against impacts and robust handling in industry.</p>
<p>&#8211; Measures temperature, humidity, barometric pressure<br />
&#8211; Flexible internal real-time data storage via SD memory card (1 &#8230; 16GB)<br />
&#8211; The saved data is saved directly as an Excel file on the SD card<br />
&#8211; Selectable pressure unit: hPa, mmHg and inHg<br />
&#8211; Low battery display<br />
&#8211; Large LCD display<br />
&#8211; Adjustable measuring rate<br />
&#8211; Easy to use<br />
&#8211; Robust housing<br />
&#8211; Optional software kit for online transfer to a PC or laptop (no software is required to evaluate the stored data)<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></p>
<table>
<tbody>
<tr>
<td><strong>Measurement ranges</strong></td>
</tr>
<tr>
<td>Temperature</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td>Relative humidity in air</td>
<td>10 &#8230; 90% RH</td>
</tr>
<tr>
<td>Barometric pressure</td>
<td>10 &#8230; 1100 hPa / 7.5 &#8230; 825 mmHg / 0.29 &#8230; 32.48 inHg</td>
</tr>
<tr>
<td><strong>Resolution</strong></td>
</tr>
<tr>
<td>Temperature</td>
<td>0.1°C / 0.18°F</td>
</tr>
<tr>
<td>Relative humidity in air</td>
<td>0.1% RH</td>
</tr>
<tr>
<td>Barometric pressure</td>
<td>0.1 hPa: 10 &#8230; 1000 hPa, 1 hPa: 1001 &#8230; 1100 hPa / 0.1 mmHg / 0.01 inHg</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
</tr>
<tr>
<td>Temperature</td>
<td>± 0.8°C / ± 1.4°F</td>
</tr>
<tr>
<td>Relative humidity in air</td>
<td>± 4% RH: &lt; 70% RH<br />
± ( 4% reading + 1% RH): ≥ 70% RH</td>
</tr>
<tr>
<td>Barometric pressure</td>
<td>± 2 hPa: 10 &#8230; 1000 hPa, ± 3 hPa: 1001 &#8230; 1100 hPa / ± 1.5 mmHg / ± 0.1 inHg</td>
</tr>
<tr>
<td>Sampling interval</td>
<td>5,10, 30, 60, 120, 300 or 600 seconds, or automatic (it stores data when there is an alteration of the value of ± 1º, ±1 % RH or ± 1 hPa)</td>
</tr>
<tr>
<td>Memory</td>
<td>SD card memory up to 16 GB (an SD card is included in the delivery contents)</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0 &#8230; 50ºC / 32 &#8230; 122ºF<br />
&lt; 90% RH</td>
</tr>
<tr>
<td>Power</td>
<td>6 x 1.5V AAA batteries or<br />
1 x 9V electric power supply (optional)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>132 mm x 80 mm x 32 mm / 5.1 in x 3.1 in x 1.3 in</td>
</tr>
<tr>
<td>Weight (with batteries)</td>
<td>285 g / &lt; 1 lb</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-thb-40-ica-incl-iso-calibration-certificate/">Environmental Tester PCE-THB 40-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-thb-40-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13204</post-id>	</item>
		<item>
		<title>Environmental Tester w/ Calibration Certificate PCE-HT110-ICA</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-w-calibration-certificate-pce-ht110-ica/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-w-calibration-certificate-pce-ht110-ica/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:15:55 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13200</guid>

					<description><![CDATA[<p><strong>PCE-HT110-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-w-calibration-certificate-pce-ht110-ica/">Environmental Tester w/ Calibration Certificate PCE-HT110-ICA</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-HT110-ICA Environmental Tester w/ ISO Calibration Certificate</strong><br />
<strong>2-channel data recorder with real-time LCD display and SD card memory</strong></p>
<p align="justify">The PCE-HT110-ICA Environmental Tester or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110-ICA is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.</p>
<p>The PCE-HT110-ICA Environmental Tester can be used to monitor climate-controlled environments such as supermarket refrigerators, refrigerated / reefer trucks and cold storage units. It is also useful for monitoring home HVAC systems, wood floor installations, cigar humidors, industrial heating and cooling processes, machine operating temperatures and product storage / warehouse conditions.</p>
<p>The PCE-HT110-ICA comes calibrated according to ISO standards. An ISO calibration certificate is included in the delivery contents.</p>
<p><strong>Customer Review</strong></p>
<p align="justify">&#8220;We use a humidity / temperature monitor from the PCE Group, Model PCE-HT110-ICA. It logs both temperature and humidity on an ongoing basis at regular intervals. The measurements are stored on an SD card which allows one to download the data to a spreadsheet for reference. Prior to receiving the unit, PCE sent it to a certified calibration service to ensure the unit was recording accurately. This has been very helpful to our work. A bonus is, by having the unit mounted on the job site, everyone is constantly reminded of the environmental conditions and can correct as necessary.&#8221;<br />
— <em>Jerry Wilson, Interior Architecture, Design and Certified General Contractor, Bespoke Design &amp; Consulting, Juno Beach, Florida, USA</em></p>
<p align="justify">&#8211; Low battery indication<br />
&#8211; Programmable date and time<br />
&#8211; Impact-resistant electrical components<br />
&#8211; Sturdy, dust- and water-resistant enclosure<br />
&#8211; .XLS data format (compatible with Microsoft Excel)<br />
&#8211; Battery powered (optional 9V AC adapter available)<br />
&#8211; Optional USB data cable incl. software allows real-time data visualization via PC</p>
<table>
<tbody>
<tr>
<td>Measurement ranges</td>
<td>0 … 50°C / 32 &#8230; 122°F, 10 &#8230; 90% r.H.</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.8°C / ± 1.4°F<br />
± 4% r.H.</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1°C / 0.18°F, 0.1% r.H.</td>
</tr>
<tr>
<td>Memory</td>
<td>SD card 1 &#8230; 16 GB (2 GB SD card in delivery)</td>
</tr>
<tr>
<td>Measurement rate / sampling interval</td>
<td>Adjustable, 5, 10, 30, 60, 120, 300, or 600 seconds, or automatic (If the value changes by ± 1% r.H. Or ± 1°C / ± 1.8°F, the data record is automatically written to memory)</td>
</tr>
<tr>
<td>Date and time</td>
<td>Programmable</td>
</tr>
<tr>
<td>Power supply</td>
<td>6 x 1.5V batteries (AAA) / 9V power adapter (optional)</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F, 0 &#8230; 90% r.H.</td>
</tr>
<tr>
<td>Dimensions</td>
<td>132 x 80 x 32 mm / 5.2 x 3.1 x 1.3 in</td>
</tr>
<tr>
<td>Weight</td>
<td>282 g / &lt; 1 lb</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-w-calibration-certificate-pce-ht110-ica/">Environmental Tester w/ Calibration Certificate PCE-HT110-ICA</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-w-calibration-certificate-pce-ht110-ica/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13200</post-id>	</item>
		<item>
		<title>Environmental Electromagnetic Radiation Tester PCE-EM 30</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-radiation-tester-pce-em-30/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-radiation-tester-pce-em-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:12:59 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13196</guid>

					<description><![CDATA[<p><strong>PCE-EM 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-radiation-tester-pce-em-30/">Environmental Electromagnetic Radiation Tester PCE-EM 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>PCE-EM 30 Environmental Electromagnetic Radiation Tester<br />
Triple-axis electromagnetic field (EMF) detector with data-logging functionality / Comes with two external sensor probes (for low and high frequency ranges)</strong></p>
<p align="justify">PCE-EM 30 is a digital portable 3-axis environmental electromagnetic radiation tester or EMF detector used to measure electromagnetic radiation generated by electronic devices and electric installations. This triple-axis EMF meter provides greater precision than single-axis models as well as affords the ability to assess EMFs from more than one source at a time.</p>
<p><strong>Note: USB data cable Incl. software VT-204-SW required for data transfer to PC &#8211; please see accessories tab for details.</strong></p>
<p>&#8211; EMF measuring ranges: 0 to 199.99 V/m, 0 to 99.999 W/m², 0 to 9.9999 mW/cm²<br />
&#8211; EMF bandwidth: 100 kHz to 3 GHz<br />
&#8211; Measures EMF of 5G cellular Low-band and Mid-band<br />
&#8211; Comes with two external sensor probes (for low and high frequency ranges)<br />
&#8211; Features a large, easy-to-read LCD screen<br />
&#8211; Adjustable alarm value<br />
&#8211; Note: USB data cable Incl. software VT-204-SW required for data transfer to PC &#8211; please see accessories tab for details</p>
<table>
<tbody>
<tr>
<td>Bandwidth / Frequency range of the probe EP-03H</td>
<td>100 MHz &#8230; 3 GHz</td>
</tr>
<tr>
<td>Range selection for the probe EP-03H</td>
<td>900 MHz, 1 GHz, 1.8 GHz,<br />
2.4 GHz, 2.45 GHz, 3 GHz</td>
</tr>
<tr>
<td>Bandwidth / Frequency range of the probe EP-04L</td>
<td>100 kHz &#8230; 100 MHz</td>
</tr>
<tr>
<td>Range selection for the probe EP-04L</td>
<td>100 kHz, 200 kHz, 500 kHz, 1 MHz,<br />
10 MHz, 13.56 MHz, 100 MHz</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±2 dB</td>
</tr>
<tr>
<td>Measuring ranges</td>
<td>0 &#8230; 199.99 V/m<br />
0 &#8230; 99.999 W/m²<br />
0 &#8230; 9.9999 mW/cm²</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01 V/m<br />
0.001 W/m²<br />
0.0001 mW/cm²</td>
</tr>
<tr>
<td>Inital value</td>
<td>&gt; 1 V/m<br />
&gt; 0.03 W/m²<br />
&gt; 0.0003 mW/cm²</td>
</tr>
<tr>
<td>External sensor probe types</td>
<td>Triple axis</td>
</tr>
<tr>
<td>Display</td>
<td>LCD, 58 x 34 mm / 2.28 x 1.34&#8243;</td>
</tr>
<tr>
<td>Limit value</td>
<td>Adjustable</td>
</tr>
<tr>
<td>Alarm</td>
<td>Acoustic signal when limit value is exceeded</td>
</tr>
<tr>
<td>Internal memory</td>
<td>16,000 data records</td>
</tr>
<tr>
<td>Power</td>
<td>9 V battery</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50 ºC / +32 &#8230; +122 ºF, up to 80 % relative humidity (RH)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Meter: 200 x 76.2 x 36.8 mm / 7.88 x 3.00 x 1.45&#8243;<br />
Probes: 70 x 240 mm / 2.76 x 9.45&#8243;</td>
</tr>
<tr>
<td>Weight</td>
<td>523 g / 1.16 lb (with battery included)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-radiation-tester-pce-em-30/">Environmental Electromagnetic Radiation Tester PCE-EM 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-radiation-tester-pce-em-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13196</post-id>	</item>
		<item>
		<title>Environmental Tester PCE-DPM 3-ICA</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3-ica/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3-ica/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:11:25 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13194</guid>

					<description><![CDATA[<p><strong>PCE-DPM 3-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3-ica/">Environmental Tester PCE-DPM 3-ICA</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental Tester PCE-DPM 3-ICA incl. ISO Calibration Certificate<br />
Sintered cap to protect against moisture and dust / Data can be read out via any computer / Data memory for approx. 50,000 measurement data / CSV format / Battery can be recharged via micro-USB / Easy operation</strong></div>
<div></div>
<div>The hygrometer is a mobile testing device for monitoring the quality of compressed air on stationary and mobile compressed air generators. This hygrometer measures the temperature, the relative humidity, H2O and calculates the current dew point up to an ambient pressure of 20 bar. Thanks to the sintered cap, the hygrometer in the pressure lines is protected from dirt, moisture and high flow speeds. This increases the service life of the hygrometer&#8217;s sensors.</div>
<div></div>
<div>The data memory of the hygrometer enables the course of the measurement parameters to be recorded in a pressure line. The data recorded by the hygrometer is permanently stored in the internal memory. The memory can be read out directly on the hygrometer. The hygrometer can also be connected to an operating system independent computer via the micro USB interface. This is made possible because the hygrometer is recognized as a mass data storage device. The data saved by the pressure dew point measuring device are saved in CSV format. The stored measurement data can thus be evaluated using any spreadsheet program.</div>
<div></div>
<div>&#8211; Data storage with CSV data export<br />
&#8211; Dew point, H2O, temperature, humidity measurement<br />
&#8211; For inline measurement of pressure pipes<br />
&#8211; Battery operation for mobile use<br />
&#8211; With G1 / 2 &#8220;connection thread<br />
&#8211; Sensors protected with sintered filters<br />
&#8211; incl. ISO Calibration Certificate</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Temperature</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>-10 &#8230; 60°C / 14 &#8230; 140</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01°C / 0.018</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C / 68</span>°F</td>
<td valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122°F: ± 0.3°C / 0.5</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Relative humidity</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>0 &#8230; 100%</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01%</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C</span><span> / 68</span>°F</td>
<td valign="top"><span>&lt; 5%:</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>± (0.025% + 17.5% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>&gt; 5%: ± (1% + 5% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>&gt; 15%: ± (2% + 3% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Dew point*</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>-50 &#8230; 30°C / -58 &#8230; 86</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01°C</span><span> / 0.018</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Accuracy </span></td>
<td valign="top"><span>-40 &#8230; 20°C / -40 &#8230; 68°F: ± 2°C / 3.6</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>-50 &#8230; -40°C / -58 &#8230; -40°F: ± 2.5°C / 4.5°F</span></p>
<p>&nbsp;</td>
</tr>
<tr>
<td colspan="2" valign="top"><span>*</span><span>The accuracy of the dew point relates to an  </span><br />
<span>ambient temperature of 16 &#8230; 25°C / 61 &#8230; 77°F</span></p>
<p>&nbsp;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>H2O</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>40 &#8230; 20,000 ppm</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>1 ppm</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C</span><span> / 68</span>°F</td>
<td valign="top"><span>± (7.3 ppm + 8.3%)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions</span></td>
<td valign="top"><span>-10 &#8230; 60°C</span><span> / 14 &#8230; 140</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>0 &#8230; 20 bar (absolute)</span></td>
</tr>
<tr>
<td valign="top"><span>Response time at: 0.2 m / s, 1 bar,        </span></td>
<td valign="top"><span>0 &#8230; 40°C / 32 &#8230; 104°F: 20s [120s]</span></td>
</tr>
<tr>
<td valign="top"><span>20°C / 68°F, 63% RH [90%] </span></td>
<td valign="top"><span>-40 &#8230; 0°C / -40 &#8230; 32°F: 10s [20s]</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td valign="top"><span>For approx. 50,000 measuring points</span></td>
</tr>
<tr>
<td valign="top"><span>Adjustable storage rates</span></td>
<td valign="top"><span>10 seconds</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>1, 5, 10, 20, minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Adjustable recording time</span></td>
<td valign="top"><span>1, 5, 12, 24, 48 hours</span></td>
</tr>
<tr>
<td valign="top"><span>File format</span></td>
<td valign="top"><span>CSV</span></td>
</tr>
<tr>
<td valign="top"><span>Cable length</span></td>
<td valign="top"><span>Approx. 1.5 m / 4.9 ft</span></td>
</tr>
<tr>
<td valign="top"><span>Thread</span></td>
<td valign="top"><span>G1 / 2&#8243;</span></td>
</tr>
<tr>
<td valign="top"><span>Thread length</span></td>
<td valign="top"><span>1.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Probe length</span></td>
<td valign="top"><span>5.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Probe width</span></td>
<td valign="top"><span>1.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td valign="top"><span>2.3&#8243; LCD</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td valign="top"><span>Battery 3.7V DC, 3000-mAh</span></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Power supply power pack</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Primary: 100 &#8230; 240V AC, 0.25 A</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Secondary: 5V DC, 1 A</span></td>
</tr>
<tr>
<td valign="top"><span>Interface 7 mains connection</span></td>
<td valign="top"><span>Micro USB</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td valign="top"><span>Approx. 610 g / 1.3 lbs</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3-ica/">Environmental Tester PCE-DPM 3-ICA</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3-ica/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13194</post-id>	</item>
		<item>
		<title>Environmental Tester PCE-DPM 3</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:08:38 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13190</guid>

					<description><![CDATA[<p><strong>PCE-DPM 3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3/">Environmental Tester PCE-DPM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental tester</strong><strong> PCE-DPM 3<br />
Sintered cap to protect against moisture and dust / Data can be read out via any computer / Data memory for approx. 50,000 measurement data / CSV format / Battery can be recharged via micro-USB / Easy operation</strong></div>
<div></div>
<div>The environmental tester is a mobile testing device for monitoring the quality of compressed air on stationary and mobile compressed air generators. This environmental tester measures the temperature, the relative humidity, H2O and calculates the current dew point up to an ambient pressure of 20 bar. Thanks to the sintered cap, the environmental tester in the pressure lines is protected from dirt, moisture and high flow speeds. This increases the service life of the environmental tester&#8217;s sensors.</div>
<div></div>
<div>The data memory of the environmental tester enables the course of the measurement parameters to be recorded in a pressure line. The data recorded by the environmental tester is permanently stored in the internal memory. The memory can be read out directly on the environmental tester. The environmental tester can also be connected to an operating system independent computer via the micro USB interface. This is made possible because the environmental tester is recognized as a mass data storage device. The data saved by the pressure dew point measuring device are saved in CSV format. The stored measurement data can thus be evaluated using any spreadsheet program.</div>
<div></div>
<div>&#8211; Data storage with CSV data export<br />
&#8211; Dew point, H2O, temperature, humidity measurement<br />
&#8211; For inline measurement of pressure pipes<br />
&#8211; Battery operation for mobile use<br />
&#8211; With G1 / 2 &#8220;connection thread<br />
&#8211; Sensors protected with sintered filters</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Temperature</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>-10 &#8230; 60°C / 14 &#8230; 140</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01°C / 0.018</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C / 68</span>°F</td>
<td valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122°F: ± 0.3°C / 0.5</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Relative humidity</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>0 &#8230; 100%</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01%</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C</span><span> / 68</span>°F</td>
<td valign="top"><span>&lt; 5%:</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>± (0.025% + 17.5% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>&gt; 5%: ± (1% + 5% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>&gt; 15%: ± (2% + 3% of mv)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>Dew point*</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>-50 &#8230; 30°C / -58 &#8230; 86</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.01°C</span><span> / 0.018</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Accuracy </span></td>
<td valign="top"><span>-40 &#8230; 20°C / -40 &#8230; 68°F: ± 2°C / 3.6</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>-50 &#8230; -40°C / -58 &#8230; -40°F: ± 2.5°C / 4.5°F</span></p>
<p>&nbsp;</td>
</tr>
<tr>
<td colspan="2" valign="top"><span>*</span><span>The accuracy of the dew point relates to an  </span><br />
<span>ambient temperature of 16 &#8230; 25°C / 61 &#8230; 77°F</span></p>
<p>&nbsp;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measurement</span></td>
<td valign="top"><span>H2O</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>40 &#8230; 20,000 ppm</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>1 ppm</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy at 20°C</span><span> / 68</span>°F</td>
<td valign="top"><span>± (7.3 ppm + 8.3%)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions</span></td>
<td valign="top"><span>-10 &#8230; 60°C</span><span> / 14 &#8230; 140</span>°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>0 &#8230; 20 bar (absolute)</span></td>
</tr>
<tr>
<td valign="top"><span>Response time at: 0.2 m / s, 1 bar,        </span></td>
<td valign="top"><span>0 &#8230; 40°C / 32 &#8230; 104°F: 20s [120s]</span></td>
</tr>
<tr>
<td valign="top"><span>20°C / 68°F, 63% RH [90%] </span></td>
<td valign="top"><span>-40 &#8230; 0°C / -40 &#8230; 32°F: 10s [20s]</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td valign="top"><span>For approx. 50,000 measuring points</span></td>
</tr>
<tr>
<td valign="top"><span>Adjustable storage rates</span></td>
<td valign="top"><span>10 seconds</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>1, 5, 10, 20, minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Adjustable recording time</span></td>
<td valign="top"><span>1, 5, 12, 24, 48 hours</span></td>
</tr>
<tr>
<td valign="top"><span>File format</span></td>
<td valign="top"><span>CSV</span></td>
</tr>
<tr>
<td valign="top"><span>Cable length</span></td>
<td valign="top"><span>Approx. 1.5 m / 4.9 ft</span></td>
</tr>
<tr>
<td valign="top"><span>Thread</span></td>
<td valign="top"><span>G1 / 2&#8243;</span></td>
</tr>
<tr>
<td valign="top"><span>Thread length</span></td>
<td valign="top"><span>1.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Probe length</span></td>
<td valign="top"><span>5.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Probe width</span></td>
<td valign="top"><span>1.2 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td valign="top"><span>2.3&#8243; LCD</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td valign="top"><span>Battery 3.7V DC, 3000-mAh</span></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Power supply power pack</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Primary: 100 &#8230; 240V AC, 0.25 A</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Secondary: 5V DC, 1 A</span></td>
</tr>
<tr>
<td valign="top"><span>Interface 7 mains connection</span></td>
<td valign="top"><span>Micro USB</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td valign="top"><span>Approx. 610 g / 1.3 lbs</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3/">Environmental Tester PCE-DPM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-dpm-3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13190</post-id>	</item>
		<item>
		<title>Environmental Testing Device PCE-MPC 30</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-testing-device-pce-mpc-30/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-testing-device-pce-mpc-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:06:00 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13187</guid>

					<description><![CDATA[<p><strong>PCE-MPC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-testing-device-pce-mpc-30/">Environmental Testing Device PCE-MPC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental Testing Device with data logger / HCHO measurement / battery for mobile use / </strong><strong>2.8 &#8220;TFT display / measurement of mass concentration / data storage on SD card</strong></div>
<div></div>
<div>This Environmental Testing Device has many functions. With the Environmental Testing Device it is possible to determine the number of particles in the size of 0.3, 2.5 and 10 µm. In addition to measuring the particles, the Environmental Testing Device can also measure the PM 2.5 and PM 10 mass concentration. The mass concentration of the Environmental Testing Device determines the weight of the particles on one cubic meter.</div>
<div></div>
<div>In addition to particle measurement, the Environmental Testing Device can also determine the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity and the dew point are determined and displayed by the Environmental Testing Device. As a further important property, the Environmental Testing Device can also store data. It is therefore possible with the Environmental Testing Device to evaluate all measured values after a measurement.</div>
<div></div>
<div>&#8211; Particle counter, HCHO, temperature measurement</div>
<div>&#8211; Measured value recording for later analyzes</div>
<div>&#8211; Large 2.8 &#8220;LC display, 320 x 240 pixels</div>
<div>&#8211; Mass concentration PM 2.5 and PM 10</div>
<div>&#8211; Battery for mobile use</div>
<div>&#8211; Dew point and wet bulb temperature</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="223">Measurable particle sizes</td>
<td valign="top" width="285"><strong>PM 2.5 and PM 10</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 2000 µg / m³</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 µg / m³</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Particle counter</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurable particle sizes</td>
<td valign="top">0.3, 2.5, 10 µm</td>
</tr>
<tr>
<td valign="top">Flow rate</td>
<td valign="top">2.83L / min (0.1 ft³)</td>
</tr>
<tr>
<td valign="top">Counting efficiency</td>
<td valign="top">50% at 0.3 µm;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">100% with particle size&gt; 0.45 µm</td>
</tr>
<tr>
<td valign="top">Coincidence error</td>
<td valign="top">&lt;5% at 2,000,000 particles per ft³</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td valign="top">5000 data records (micro SD card)</td>
</tr>
<tr>
<td valign="top">Counting modes</td>
<td valign="top">cumulative, differential, concentration</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>HCHO</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0.01 &#8230; 5.00 ppm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 5%</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 ppm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Air temperature and relative humidity</strong></td>
</tr>
<tr>
<td valign="top">Measuring range air temperature</td>
<td valign="top">0 &#8230; 50 ° C, 32 &#8230; 122 ° F</td>
</tr>
<tr>
<td valign="top">Measuring range dew point</td>
<td valign="top">0 &#8230; 50 ° C, 32 &#8230; 122 ° F</td>
</tr>
<tr>
<td valign="top">Relative humidity measuring range</td>
<td valign="top">0 &#8230; 100% RH</td>
</tr>
<tr>
<td valign="top">Air temperature measurement accuracy</td>
<td valign="top">10 &#8230; 40 ° C: ± 1 ° C, ± 1.8 ° F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Others: ± 2 ° C, ± 3.6 ° F</td>
</tr>
<tr>
<td valign="top">Measuring accuracy dew point temperature</td>
<td valign="top">10 &#8230; 40 ° C: ± 1 ° C, ± 1.8 ° F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Others: ± 2 ° C, ± 3.6 ° F</td>
</tr>
<tr>
<td valign="top">Relative humidity accuracy</td>
<td valign="top">0 &#8230; 20% rel. Humidity: ± 5%</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">20 &#8230; 80% rel. Humidity: ± 3.5%</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">80 &#8230; 100% rel. Fencing: ± 5%</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>More specifications</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; +50 ° C, 10 &#8230; 90% rel. humidity,</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">not condensing</td>
</tr>
<tr>
<td valign="top">Storage conditions</td>
<td valign="top">-10 &#8230; +60 ° C, 10 &#8230; 90% rel. humidity,</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">not condensing</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">2.8 &#8220;, 320 x 240 pixels, backlit color LCD</td>
</tr>
<tr>
<td valign="top">Power supply mains adapter</td>
<td valign="top">Primary: 100 &#8230; 240 V AC, 50/60 Hz, 0.6 A.</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Secondary: 9 V DC, 1500 mA</td>
</tr>
<tr>
<td valign="top">Power supply battery</td>
<td valign="top">7.4 V, 1200 mAh, 8.88 Wh</td>
</tr>
<tr>
<td valign="top">Battery Life</td>
<td valign="top">approx. 4 hours in continuous operation</td>
</tr>
<tr>
<td valign="top">Battery recharge time</td>
<td valign="top">approx. 2 hours with AC adapter</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">240 x 75 x 57 mm</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">570 g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-testing-device-pce-mpc-30/">Environmental Testing Device PCE-MPC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-testing-device-pce-mpc-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13187</post-id>	</item>
		<item>
		<title>Environmental Tester PCE-AQD 20-ICA Incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 04:03:35 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13180</guid>

					<description><![CDATA[<p><strong>PCE-AQD 20-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20-ica-incl-iso-calibration-certificate/">Environmental Tester PCE-AQD 20-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental </strong><strong>tester PCE-AQD 20-ICA incl. ISO calibration certificate</strong></div>
<div style="text-align: center"><strong>Air quality data logger for 5 parameters / Measures temperature, humidity, CO2, PM2.5 and air pressure / SD storage / XLS format / Large LCD / Power adapter and battery operation</strong></div>
<div style="text-align: center"></div>
<div>The air quality data logger PCE-AQD 20 is an ideal measuring device for monitoring the air quality at workplaces. The air quality data logger is ideal for continuous logging of air temperature, humidity, CO2, PM2.5 and air pressure. All these parameters give the occupational safety expert information about the air quality. The measured values ​​are stored by the CO2 air quality data logger on an SD memory card.</div>
<div></div>
<div>The format is XLS, so the measured values ​​can be read directly into Excel, without having to be incorporated into a new software. The measured values ​​are displayed on the large, illuminated display. The air quality data logger is operated by batteries or 9 V power supply unit. As a special feature, this air quality data logger is equipped with an alarm function. This offers the possibility to inform the user about an exceeding of temperature, air humidity or dust load. In addition to the measured values, the air quality data logger also informs about the current time.</div>
<div></div>
<div>&#8211; 5 measuring functions<br />
&#8211; Excel data logger on SD card<br />
&#8211; Large display<br />
&#8211; Battery and power adapter operation<br />
&#8211; Ideal for workplace monitorin</div>
<div>&#8211; Alarm functio</div>
<p><strong>&#8211; Incl. ISO calibration certificate</strong></p>
<table>
<tbody>
<tr>
<td><strong><span>Measurement function PM2.5</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 250 μm / m³</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>1 μm / m³</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± (10% of rdg. + 15 μm)</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function humidity</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>5 &#8230; 95% rh</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1% RH</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>&gt; 70% RH: ± (3% of the prev</span></td>
</tr>
<tr>
<td></td>
<td><span>+ 1% RH)</span></td>
</tr>
<tr>
<td></td>
<td><span>&lt;70% RH: ± 3% RH</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function temperature</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 50°C / 32 &#8230; 122</span></strong><span>°F</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1°C / 0.18°F</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.8°C / 1.44°F</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measurement function CO2</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 10,000 ppm </span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>1 ppm</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>&lt; 1000 ppm: ± 40 ppm</span></td>
</tr>
<tr>
<td></td>
<td><span>&lt; 3000 ppm: ± (50 ppm + 3% of rdg.)</span></td>
</tr>
<tr>
<td></td>
<td><span>&gt; 3000 ppm: ± (50 ppm + 5% of rdg.)</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function </span></strong><strong><span>air pressure</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>10 &#8230; 1100 hPa</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1 hPa</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 1.5 hPa</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>LCD display with backlight</span></td>
</tr>
<tr>
<td><span>Storage</span></td>
<td><span>SD card max. 32 GB</span></td>
</tr>
<tr>
<td><span>Storage rate</span></td>
<td><span>2 &#8230; 3,600 s</span></td>
</tr>
<tr>
<td><span>Memory error</span></td>
<td><span>&lt; 0.1% of the completely stored data</span></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>Hold, Max, Min</span></td>
</tr>
<tr>
<td><span>Measuring rate</span></td>
<td><span>About 1 s</span></td>
</tr>
<tr>
<td><span>Interface</span></td>
<td><span>Serial for live visualization on computers</span></td>
</tr>
<tr>
<td></td>
<td><span>(Data cable SOFT-LUT-USB sold separately)</span></td>
</tr>
<tr>
<td><span>Alarm output</span></td>
<td><span>OC output 24V / 70-mA DC</span></td>
</tr>
<tr>
<td><span>Power supply</span></td>
<td><span>6 x 1.5V AA battery</span></td>
</tr>
<tr>
<td></td>
<td><span>9V / 1 A power adapter</span></td>
</tr>
<tr>
<td><span>Current consumption</span></td>
<td><span>230-mA without lighting</span></td>
</tr>
<tr>
<td></td>
<td><span>approx. 250-mA with lighting</span></td>
</tr>
<tr>
<td><span>Operating conditions</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</span></td>
</tr>
<tr>
<td><span>Weight</span></td>
<td><span>About 387 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td><span>Dimensions</span></td>
<td><span>164 x 93 x 72 mm / 6.5 x 3.7 x 2.8 in</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20-ica-incl-iso-calibration-certificate/">Environmental Tester PCE-AQD 20-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13180</post-id>	</item>
		<item>
		<title>Environmental Tester PCE-AQD 20</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 03:52:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13172</guid>

					<description><![CDATA[<p><strong>PCE-AQD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20/">Environmental Tester PCE-AQD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Environmental tester PCE-AQD 20</strong></div>
<div style="text-align: center"><strong>Air quality data logger for 5 parameters / Measures temperature, humidity, CO2, PM2.5 and air pressure / SD storage / XLS format / Large LCD / Power adapter and battery operation</strong></div>
<div></div>
<div>The air quality data logger PCE-AQD 20 is an ideal measuring device for monitoring the air quality at workplaces. The air quality data logger is ideal for continuous logging of air temperature, humidity, CO2, PM2.5 and air pressure. All these parameters give the occupational safety expert information about the air quality. The measured values ​​are stored by the CO2 air quality data logger on an SD memory card.</div>
<div></div>
<div>The format is XLS, so the measured values ​​can be read directly into Excel, without having to be incorporated into a new software. The measured values ​​are displayed on the large, illuminated display. The air quality data logger is operated by batteries or 9 V power supply unit. As a special feature, this air quality data logger is equipped with an alarm function. This offers the possibility to inform the user about an exceeding of temperature, air humidity or dust load. In addition to the measured values, the air quality data logger also informs about the current time.</div>
<div></div>
<div>&#8211; 5 measuring functions<br />
&#8211; Excel data logger on SD card<br />
&#8211; Large display<br />
&#8211; Battery and power adapter operation<br />
&#8211; Ideal for workplace monitoring<br />
&#8211; Alarm function</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td><strong><span>Measurement function PM2.5</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 250 μm / m³</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>1 μm / m³</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± (10% of rdg. + 15 μm)</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function humidity</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>5 &#8230; 95% rh</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1% RH</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>&gt; 70% RH: ± (3% of the prev</span></td>
</tr>
<tr>
<td></td>
<td><span>+ 1% RH)</span></td>
</tr>
<tr>
<td></td>
<td><span>&lt;70% RH: ± 3% RH</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function temperature</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 50°C / 32 &#8230; 122</span></strong><span>°F</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1°C / 0.18°F</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.8°C / 1.44°F</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measurement function CO2</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>0 &#8230; 10,000 ppm </span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>1 ppm</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>&lt; 1000 ppm: ± 40 ppm</span></td>
</tr>
<tr>
<td></td>
<td><span>&lt; 3000 ppm: ± (50 ppm + 3% of rdg.)</span></td>
</tr>
<tr>
<td></td>
<td><span>&gt; 3000 ppm: ± (50 ppm + 5% of rdg.)</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><span>Measuring function </span></strong><strong><span>air pressure</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><strong><span>10 &#8230; 1100 hPa</span></strong></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1 hPa</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 1.5 hPa</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>LCD display with backlight</span></td>
</tr>
<tr>
<td><span>Storage</span></td>
<td><span>SD card max. 32 GB</span></td>
</tr>
<tr>
<td><span>Storage rate</span></td>
<td><span>2 &#8230; 3,600 s</span></td>
</tr>
<tr>
<td><span>Memory error</span></td>
<td><span>&lt; 0.1% of the completely stored data</span></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>Hold, Max, Min</span></td>
</tr>
<tr>
<td><span>Measuring rate</span></td>
<td><span>About 1 s</span></td>
</tr>
<tr>
<td><span>Interface</span></td>
<td><span>Serial for live visualization on computers</span></td>
</tr>
<tr>
<td></td>
<td><span>(Data cable SOFT-LUT-USB sold separately)</span></td>
</tr>
<tr>
<td><span>Alarm output</span></td>
<td><span>OC output 24V / 70-mA DC</span></td>
</tr>
<tr>
<td><span>Power supply</span></td>
<td><span>6 x 1.5V AA battery</span></td>
</tr>
<tr>
<td></td>
<td><span>9V / 1 A power adapter</span></td>
</tr>
<tr>
<td><span>Current consumption</span></td>
<td><span>230-mA without lighting</span></td>
</tr>
<tr>
<td></td>
<td><span>approx. 250-mA with lighting</span></td>
</tr>
<tr>
<td><span>Operating conditions</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</span></td>
</tr>
<tr>
<td><span>Weight</span></td>
<td><span>About 387 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td><span>Dimensions</span></td>
<td><span>164 x 93 x 72 mm / 6.5 x 3.7 x 2.8 in</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20/">Environmental Tester PCE-AQD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-tester-pce-aqd-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13172</post-id>	</item>
		<item>
		<title>Environmental Electromagnetic Field Radiation Tester PCE-G28-ICA inc. ISO Cal.</title>
		<link>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-field-radiation-tester-pce-g28-ica-inc-iso-cal/</link>
					<comments>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-field-radiation-tester-pce-g28-ica-inc-iso-cal/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Feb 2021 03:22:29 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=13168</guid>

					<description><![CDATA[<p><strong>PCE-G28-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-field-radiation-tester-pce-g28-ica-inc-iso-cal/">Environmental Electromagnetic Field Radiation Tester PCE-G28-ICA inc. ISO Cal.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-G28-ICA is a portable, handheld environmental electromagnetic field radiation tester that detects electromagnetic fields (EMFs) and displays measurement results in milliGauss (mG) or microTesla (µT). This EMF radiation detector comes with an external 3-axis electromagnetic sensor (X, Y, Z direction).</p>
<p>&#8211; Measurement range: 0 &#8230; 20000 mG / 0 &#8230; 2000 µT<br />
&#8211; Accuracy: ± 4% + 3 digits / ± 5% + 3 digits / ± 10% + 5 digits<br />
&#8211; Resolution: 0.1 mG / 0.01 µT<br />
&#8211; Detects electromagnetic fields (EMFs) on three axes (X, Y, Z direction)<br />
&#8211; Displays measurement results in milliGauss (mG) or microTesla (µT)<br />
&#8211; Comes with an external 3-axis electromagnetic sensor<br />
&#8211; Data hold functionality<br />
&#8211; Ideal tool for checking transformers and measuring EMFs generated by power lines, computer monitors, electric motors and installations<br />
&#8211; Meets IEC 801-1 (EN 50081-1) / IEC 204 (EN 60204) standards<br />
&#8211; Measures EMFs through casings, coverings and housings, eliminating the need to dismantle parts for inspection<br />
&#8211; <strong>incl. ISO Calibration Certificate </strong></p>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td>mi<span lang="es">c</span>roTesla: 0 to 20 µT / 0 to 200 µT / 0 to 2000 µT<br />
milliGauss: 0 to 200 mG / 0 to 2000 mG / 0 to 20000 mG</td>
</tr>
<tr>
<td>Resolution (per range)</td>
<td>0.01 µT / 0.1 µT / 1 µT<br />
0.1 mG / 1 mG / 10 mG</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±4 % + 3 digits (in range 20 µT and 200 mG)*<br />
±5 % + 3 digits (<span lang="es">in range</span> 200 µT <span lang="es">and</span> 2000 mG)*<br />
±10 % + 5 digits (<span lang="es">in range</span> 2000 µT <span lang="es">and</span> 20000 mG)*<br />
*Refers to 50 &#8211; 60 Hz <span lang="es">y</span> &lt; 3 V/m (RF)</td>
</tr>
<tr>
<td>Sampling rate</td>
<td>Approx. 0.4 second</td>
</tr>
<tr>
<td>Frequency</td>
<td>30 &#8230; 300 Hz</td>
</tr>
<tr>
<td>Display</td>
<td>LCD, 3.5 digits</td>
</tr>
<tr>
<td>Power</td>
<td>1 x 9V battery</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Meter: 200 x 68 x 30 mm / 7.88 x 2.68 x 1.18 in<br />
Sensor: 225 x 75 x 55 mm / 8.86 x 2.95 x 2.17 in</td>
</tr>
<tr>
<td>Weight</td>
<td>470 g / 1.04 lbs (including battery)</td>
</tr>
</tbody>
</table>
<p>See user manual for complete technical specifications.</p>
<p>The post <a href="https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-field-radiation-tester-pce-g28-ica-inc-iso-cal/">Environmental Electromagnetic Field Radiation Tester PCE-G28-ICA inc. ISO Cal.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/environmental-tester/environmental-electromagnetic-field-radiation-tester-pce-g28-ica-inc-iso-cal/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13168</post-id>	</item>
	</channel>
</rss>
