<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Flaw Detector - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/flaw-detector/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/flaw-detector/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 29 Nov 2022 16:51:57 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Flaw Detector - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/flaw-detector/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Flaw Detector PCE-USC 30</title>
		<link>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-30/</link>
					<comments>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 11 Feb 2021 02:18:17 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12983</guid>

					<description><![CDATA[<p><strong>PCE-USC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-30/">Flaw Detector PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 30 is a flaw detector designed for the non-destructive testing (NDT) and non-destructive evaluation (NDE) of electrically conductive materials. This portable, handheld flaw detector detects surface defects and measures layer thicknesses using an eddy current. The PCE-USC 30 flaw detector also measures metal conductivity in accordance with the International Annealed Copper Standard (IACS).</p>
<p>The PCE-USC 30 flaw detector has myriad applications including weld seam testing, crack detection, metallurgical and material sorting tests, quality assurance and control, aviation component testing of turbine blades, and pipeline and container testing in the chemical, oil and gas industries.<br />
&#8211; Frequency range: 0.01 &#8230; 16000 kHz<br />
&#8211; Visually depicts surface defects on screen<br />
&#8211; 4.3&#8243; full-color display (TFT)<br />
&#8211; Ergonomic design<br />
&#8211; Long battery life</p>
<p>&nbsp;</p>
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">Frequency range: 0.01 &#8230; 16000 kHz<br />
Probe voltage supply: 0, 5, 1, 2, 4, 6 V<br />
Signal phase shift: 0 &#8230; 360 °<br />
Sampling frequency: 0 &#8230; 10 kHz<br />
Duration of signal superimposition: 0 / 0.5 / 1/2/3/4 seconds<br />
Alarm: Circular, horizontal line, circle sector, cut off<br />
Display: Full-color display (TFT)<br />
Display size: 4.3 &#8220;(diagonal)<br />
Display resolution: 800 x 480 pixels<br />
Amplification adjustment: 0 &#8230; 100 dB<br />
Filters: Low-pass (1 &#8230; 4000 Hz), high-pass (1 &#8230; 4000 Hz), band, differential, average<br />
Average interval between measurement errors: 4000 hours<br />
Power supply: 12 V battery<br />
Battery capacity: 4500 mAh<br />
Continuous runtime per battery charge: Approx. 8 hours<br />
Operating temperature: -20 &#8230; +45 ° C<br />
Weight: Approx. 0.9 kg<br />
Dimensions: 230 x 135 x 98 mm</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-30/">Flaw Detector PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12983</post-id>	</item>
		<item>
		<title>Flaw Detector PCE-USC 20</title>
		<link>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-20/</link>
					<comments>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 11 Feb 2021 02:16:26 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12980</guid>

					<description><![CDATA[<p><strong>PCE-USC 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-20/">Flaw Detector PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 20 is a portable or benchtop ultrasonic flaw detector or ultrasonic thickness gauge with a 5.7&#8243; TFT color LCD screen. This ultrasound-based thickness meter uses one or two contact transducers (four different probes included; 90 °, 70 °, 60 °, 45 °) to measure material or wall thickness, detect flaws or defects in welds, and monitor the effects of corrosion on pipes and tanks.</p>
<p>PCE-USC 20 is an ultrasonic flaw detector used for non-destructive testing (NDT) and inspection in a wide variety of applications in industries such as chemical, oil and gas, metallurgical, manufacturing, quality control, metalworking, welding, machining, engineering, product research and development, construction, transportation and aerospace.<br />
&#8211; Measurement range: 0.5 &#8230; 9999 mm (steel; longitudinal wave)<br />
&#8211; Operating frequency range: 0.5 &#8230; 20 MHz<br />
&#8211; Sound velocity: 1000 &#8230; 15000 m/s (continuously adjustable)<br />
&#8211; AVG and DAC evaluation methods, display and probes delay, damping and reinforcing functions, export and reporting functions<br />
&#8211; Saves up to 500 records to memory<br />
&#8211; Lightweight design for ease of portability<br />
&#8211; Complies with EN12668-1</p>
<p>&nbsp;</p>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="2" valign="top" height="28">
<p align="left"><strong>Technical specifications<br />
</strong></p>
</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Measurement range</td>
<td valign="top" width="347" height="1">0.5 &#8230; 9999 mm (longitudinal shaft steel), continuously adjustable</td>
</tr>
<tr>
<td valign="top" width="250" height="24">Sound velocity</td>
<td valign="top" width="347" height="24">1000 &#8230; 15000 m/s, continuously adjustable, coarse adjustment</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display delay</td>
<td valign="top" width="347" height="21">-10 &#8230; 2000 mm</td>
</tr>
<tr>
<td valign="top" width="250" height="2">Probe delay</td>
<td valign="top" width="347" height="2">0.00 &#8230; 199.9 µs</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Transmitting impulse</td>
<td valign="top" width="347" height="1">400 V negative signal peaks</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Damping (impulse generator)</td>
<td valign="top" width="347" height="21">50 / 100 / 200 / 500</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Work mode</td>
<td valign="top" width="347" height="21">One- or two-probe measurement</td>
</tr>
<tr>
<td valign="top" width="250" height="11">Operating frequency range</td>
<td valign="top" width="347" height="11">0.5 &#8230; 20 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="5">Pulse repetition frequency</td>
<td valign="top" width="347" height="5">40 / 250 /1000 Hz optional</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Amplification / gain (receiver)</td>
<td valign="top" width="347" height="21">0 &#8230; 110 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Rectification (receiver)</td>
<td valign="top" width="347" height="21">Whole wave, positive half wave, negative half wave, high frequency representation</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Alarm limits</td>
<td valign="top" width="347" height="3">Limit A (Gate A) and Limit B (Gate B),<br />
Adjustable as positive or negative peak with automatic (visual or audible) alarm</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement mode</td>
<td valign="top" width="347" height="3">Limit value  / Extreme value mode</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation horizontal linearity</td>
<td valign="top" width="347" height="3">≤0.1 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation vertical linearity</td>
<td valign="top" width="347" height="3">≤3 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Excess sensitivity</td>
<td valign="top" width="347" height="3">≥62 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Dynamic range</td>
<td valign="top" width="347" height="3">≥40 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Resolution remote field</td>
<td valign="top" width="347" height="21">≥30 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Sampling rate</td>
<td valign="top" width="347" height="21">400 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Measurement data storage</td>
<td valign="top" width="347" height="21">500 records</td>
</tr>
<tr>
<td valign="top" width="250" height="7">Signal reproduction</td>
<td valign="top" width="347" height="7">Permanent recording of signals with the playback of dynamic echoes</td>
</tr>
<tr>
<td valign="top" width="250" height="4">Surface adjustment</td>
<td valign="top" width="347" height="4">Automatic adjustment of the error position of the angled probes</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Automatic amplification</td>
<td valign="top" width="347" height="3">20 &#8230; 80 %, in 1 % steps</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Menu language</td>
<td valign="top" width="347" height="21">English, Chinese</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Interface</td>
<td valign="top" width="347" height="21">USB-A, USB-B, Ethernet</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display</td>
<td valign="top" width="347" height="21">5.7 &#8221; TFT color LCD (640 x 480 pixels)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Operating temperature</td>
<td valign="top" width="347" height="21">-10 &#8230; +50 °C</td>
</tr>
<tr>
<td valign="top" width="250" height="40">Power supply</td>
<td valign="top" width="347" height="40">AC: 100 &#8230; 240 V<br />
DC: 15 V / 4 A</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery</td>
<td valign="top" width="347" height="21">Li-ion battery (10.8 V, 5200 mAh)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery opearting time per charge</td>
<td valign="top" width="347" height="21">&gt;6 hours</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Protection class</td>
<td valign="top" width="347" height="21">IP54</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Weight</td>
<td valign="top" width="347" height="21">1.4 kg (incl. battery)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-20/">Flaw Detector PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-usc-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12980</post-id>	</item>
		<item>
		<title>Flaw Detector PCE-FD 20</title>
		<link>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-fd-20/</link>
					<comments>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-fd-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 11 Feb 2021 02:02:57 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=12977</guid>

					<description><![CDATA[<p><strong>PCE-FD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-fd-20/">Flaw Detector PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-FD 20 is a portable ultrasonic flaw detector with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based defectoscope uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.<br />
&#8211; Operating frequency range: 1 &#8230; 10 MHz<br />
&#8211; Measured time interval range: 6 &#8230; 1000 microseconds (µs)<br />
&#8211; Sound velocity: 1000 &#8230; 9999 m/s<br />
&#8211; Implements shadow, echo and mirror-shadow testing methods<br />
&#8211; Features a USB interface for downloading data to PC for detailed analysis<br />
&#8211; Lightweight<br />
&#8211; Battery or electric power<br />
&#8211; 1.5 m long probe cable</p>
<p>&nbsp;</p>
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in active">
<div class="usertext">
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td><strong><br />
Technical specifications</strong></td>
</tr>
</tbody>
</table>
<table class="tech" border="0">
<tbody>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measure time interval range (scan duration)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">6 &#8230; 1000 microseconds (µs)</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Sound velocity range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1000 &#8230; 9999 m/s</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of measurement of time intervals</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.025 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Max. deviation of amplitude of signals at receiver input in 0 &#8230; 110 dB range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.5 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Testing gain region</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">125 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Averaging over the quantity of starts</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 16</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Range of time-variable gain (TVG) / Number of control points TVG</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">40 dB / 15</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Duration of excitation pulse to load</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 0.5 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Amplitude of excitation pulse to 50 Ohm load, not less</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">100, 200, 300</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range of receiver at -3 dB</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of amplitudes of input signals in 10 &#8230; 100% range of screen height</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Not more than 1 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measurement range of time intervals</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Prism of probe delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 15 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Automatic signaling of defects (AFS)</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dual-gate</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Setting range of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Adjusting thresholds of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 100%</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Detection of signals (receiver)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Positive half-wave, radio mode</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions of device (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">80 x 162 x 35 mm / 3.14 x 6.37 x 1.37&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions display (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">48 x 74 mm / 1.88 x 2.91&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Power supply</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">100 &#8230; 250 V AC or 3 x 1.5 V AA batteries</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Weight (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">250 g / 0.55 lb (without batteries)</p>
</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td colspan="2" valign="top" height="28"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"> <strong>PCE-FD 20</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-fd-20/">Flaw Detector PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/flaw-detector/flaw-detector-pce-fd-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12977</post-id>	</item>
	</channel>
</rss>