<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Oxygen Meter - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/oxygen-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/oxygen-meter/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 29 Nov 2022 07:21:06 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Oxygen Meter - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/oxygen-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Oxygen Meter TXgard-Plus-O2</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-plus-o2/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-plus-o2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 09:44:27 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15761</guid>

					<description><![CDATA[<p><strong>TXgard-Plus-O2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-plus-o2/">Oxygen Meter TXgard-Plus-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>TXgard-Plus-O2 Single-Gas Oxygen Meter<br />
warning for gases (Oxygen, O<sub>2</sub>, 0 &#8230; 25 % vol) / Features display and signal output / With ATEX or UL approval</strong></p>
<p align="justify">Here you can find an ATEX or UL approved Oxygen meter for flammable gases (ex), oxygen and toxic gases for fixed mounting. These Oxygen meters vary by the type of gases they measure, functionality (e.g. analogue output, relay output) or the type of indicator &#8211; there are sensors with a built-in screen (as an indicator) or without. You can choose a Oxygen meter for almost any type of gas: methane, propane, butane, pentane, LPG, ethanol, ethylene, nitrogen, acetylene, benzene (lead), phosphine, oxygen, ozone, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur dioxide, chlorine, ammonia (sensors for other types of gases can be requested). A Oxygen meter without a display (Xgard) are used in combination with an external indicator or a facility to detect gases, e.g. with the Gasmaster. Oxygen meters that operate without internal alarm relay can be used in conjunction with the GasFlag distributor.</p>
<p align="justify"><strong>Gas sensors</strong><br />
The series of sensors Xgard, TXgard, and Flamgard is always delivered calibrated and registered. By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</p>
<p align="justify"><strong>GasFlag</strong><br />
We offer the GasFlag for sensors without alarm relay. It is a small box for fixed installation without a display for signals for the input of 4… 20-mA. Its output has two alarm relays (max. 1 to 30V DC). The status is displayed through the LED, and it is powered to 230V.</p>
<p align="justify"><strong>Gasmaster</strong><br />
The Gasmaster is a power station of gas detection with a large display. There are several versions: 1 and 4 channels as well as with or without an interface for the PC. The Gasmaster also possesses an alarm relay with which light signals or ventilators can be activated. The systems of the Gasmaster and the gas sensors are delivered configured, calibrated and verified.</p>
<p align="justify">&#8211; Stationary<br />
&#8211; For (Oxygen, O<sub>2</sub>, 0 &#8230; 25 % vol)<br />
&#8211; Additional display and alarm station<br />
&#8211; ATEX or UL approval</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical Specifications for the Xgard series sensors</strong></td>
</tr>
<tr>
<td>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center">Xgard-Type 1</td>
<td align="center">Xgard-Type 5</td>
<td align="center">TCgard</td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify">Types of gases to detect with corresponding measurement range<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">
<table width="150 %" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">O2</td>
<td align="center">0 &#8230; 25 vol%</td>
</tr>
<tr>
<td align="center">H<sub>2</sub></td>
<td align="center">0 &#8230; 2000 ppm<br />
0 &#8230; 4 vol%<br />
= (100% LEL)</td>
</tr>
<tr>
<td align="center">CO</td>
<td align="center">0 &#8230; 250 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">CL<sub>2</sub></td>
<td align="center">0 &#8230; 5 ppm</td>
</tr>
<tr>
<td align="center">O<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">SO<sub>2</sub></td>
<td align="center">0 &#8230; 10 ppm</td>
</tr>
<tr>
<td align="center">PH<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">NH<sub>3</sub></td>
<td align="center">0 &#8230; 50 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230;100 % UEG<br />
inflammable gases<br />
(methane, procloth, butane, pentane, LPG, ethanol, ethylene, etc.)<br />
By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</td>
<td align="center">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Methane</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub></td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">He</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">± 3%</td>
<td align="center">± 3%</td>
<td align="center">±3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Signal output</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm/control relays</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C<br />
-4°F &#8230; +122°F</td>
<td align="center">-40°C &#8230; +55°C<br />
-40°F &#8230; +131°F</td>
<td align="center">+10°C &#8230; +55°C /<br />
+50°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications of the Xgard IR series gas sensors (with infrared measuring)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="2">
<tbody>
<tr>
<td align="justify"><span style="color: #003399">Optional components for the Xgard IR</span></td>
<td align="center"><span style="color: #003399">Xgard IR (infrared)</span></td>
<td align="center"><span style="color: #003399">Gas sensor type</span></td>
</tr>
<tr>
<td rowspan="13" align="justify" valign="top" width="35%">The response time of infrared gas sensors is T90 &lt; 30 s and zero drift is approx. ± 2% per month. For highly accurate measurements and protecting the sensors exterior, there are some optional protectors. Depending on the installation site, the protector against sunlight may be the perfect option. If the sensors are mounted outside (in the open field) or in halls and pavilions that are frequently cleaned with water or disinfected from time to time, we recommend the water deflector protector. When the sensor is mounted in high humidity environments or offshore applications and vessel installations, we recommend the gas sensor with the cap resistant to rain. The cone collector is often used when you need to detect light gases (e.g. methane). This facilitates the entry of the gas into the sensor. If you have any questions, contact us: <span style="color: #008000">+44 ( 0 ) 2380 98703 0</span></p>
<p><span style="color: #003399">Advantages to the conventional gas sensors:</span>The great advantage of infrared gas sensors is their long life ( &gt; 5 years) and almost inexistent long-term drift. This grealty lowers the cost of calibration. In addition, the sensors have a full temperature compensation. The ATEX, IECEx and UL norms allow them to be used worldwide.</td>
</tr>
<tr>
<td align="center">EX Zone</td>
<td align="center">1, 2, 21 / 22</td>
</tr>
<tr>
<td align="center">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">CO<sub>2</sub> 0 &#8230; 2 %<br />
CO<sub>2</sub> 0 &#8230; 5 %<br />
(according to sensor)<br />
0 &#8230; 100% LEL<br />
inflammable gases<br />
(Methane, propane, butane, pentane, LPG, ethanol, ethylene)</td>
</tr>
<tr>
<td align="center">Accuracy</td>
<td align="center">±2% (the whole range)</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Output signal</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Alarm / control relays</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">ATEX actual or UL</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP65 / IP66 with cap resistant to inclement weather</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">10V &#8230; 30V DC / 50-mA</td>
</tr>
<tr>
<td align="center">Temperature range</td>
<td align="center">-20ºC &#8230; +50ºC<br />
-4ºF &#8230; +122ºF</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">156 mm x 166 mm x 111 mm /<br />
6.1 in x 6.5 in x 4.4 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">1 kg / 2.2 lbs (aluminium housing)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>Technical Specifications of the TXgard series gas sensors</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center"><span style="color: #003399">TXgard IS+</span></td>
<td align="center"><span style="color: #003399">TXgard Plus</span></td>
<td align="center"><span style="color: #003399">Flamgard Plus</span></td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify" width="30%">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>O<sub>3</sub></td>
<td>0 &#8230; 1 ppm</td>
</tr>
<tr>
<td>NH<sub>3</sub></td>
<td>0 &#8230; 100 ppm</td>
</tr>
<tr>
<td>Cl<sub>2</sub></td>
<td>0 &#8230; 10 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub></td>
<td>0 &#8230; 2000 ppm</td>
</tr>
<tr>
<td>HCN</td>
<td>0 &#8230; 25 ppm</td>
</tr>
<tr>
<td>PH<sub>3</sub></td>
<td>0 &#8230; 2 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>ETO</td>
<td>0 &#8230; 10 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230; 100% UEG<br />
inflammable gases<br />
Acetylene (C2H2), ammonia (NH3), butane (C4H10), ethanol (C2H5OH), ethane (C2H6), ethylene (C2H4), hexane (C6H14), hydrogen (H2), LPG, methane (CH4), methanol (CH3OH), pentane (C5H12), steam oil, propane (C3H8), propanol (C3H8O)</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
</tr>
<tr>
<td align="justify">Output signal</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm / control relays</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">Yes</td>
<td align="center">Yes</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">11V &#8230; 30V DC / 20 mA</td>
<td align="center">10V &#8230; 30V DC / 210 mA</td>
<td align="center">10V &#8230; 30V DC / 210-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C /<br />
-4°F &#8230; +122°F</td>
<td align="center">-10°C &#8230; +55°C /<br />
+14° F &#8230; +131°F</td>
<td align="center">-10°C &#8230; +55°C /<br />
+14°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">0.7 kg / 1.5 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasflag</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td rowspan="16" align="justify" width="30%">Warning station without display to connect one of the above sensors. This unit is usually mounted on the wall. When it exceeds the threshold value, it emits an alert tone and flashes a red alarm LED. A relay output can, for example, be connected to an omnidirectional illumination. The response time of the alarm is less than 1 sec. Threshold values can be adjusted. The alarm station is almost always used with a gas sensor. When it is not desired then the sensor itself makes the indication, and the alarm sounds.</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">1 sensor can be connected, 2 or 3 conductors</td>
</tr>
<tr>
<td align="center">Input</td>
<td align="center">4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Output</td>
<td align="center">Relay output with maximum 1 A,<br />
i.e. useful for multidirectional illumination</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">2 or 3 conductors / 4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">LEDs indication</td>
<td align="center">Operating availability: green LED<br />
Difficulty: amber LED<br />
Limit is exceeded: 2 red LEDs</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
</tr>
<tr>
<td align="center">Operating temperature range</td>
<td align="center">-20°C &#8230; +70°C /<br />
-4°F &#8230; +158°F</td>
</tr>
<tr>
<td align="center">Operating humidity range</td>
<td align="center">0 &#8230; 99% R.H. non-condensed</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">13V &#8230; 28V DC</td>
</tr>
<tr>
<td align="center">Colour</td>
<td align="center">RAL7035</td>
</tr>
<tr>
<td align="center">Housing</td>
<td align="center">ABS plastic</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">210 mm x 145 mm x 46 mm /<br />
8.3 in x 5.7 in x 1.8 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">0.5 kg / 1.1 lbs</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">EN 50270/EMC</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP 20</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasmaster (1 &#8211; 4 gas sensors)</strong></td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td colspan="3" align="justify">Digital display and control panel for gas sensors described above. There are two Gasmaster models: GM 1 for a GM sensor, and 4 for up to 4 sensors (shows 4 values at one time). In addition to the standard analogue output, both types are available with an RS 232 data interface. The device also has relay outputs to activate a multidirectional light. The housing of the apparatus is protected against dust and splashing water. The unit is standard equipped with a battery so it will continue operating in case of a power failure.</td>
</tr>
<tr>
<td align="justify">Model</td>
<td align="center">GM 1</td>
<td align="center">GM 4</td>
</tr>
<tr>
<td align="justify">Sensors inputs</td>
<td align="center">1 input for one of the gas sensors</td>
<td align="center">4 inputs for 4 gas sensors</td>
</tr>
<tr>
<td align="justify">Outputs</td>
<td align="center">&#8211; 1 relay output<br />
(250 VAC/8 A)<br />
&#8211; 1 analogue output<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital -optional</td>
<td align="center">&#8211; 4 relay outputs<br />
(250 VAC/8 A)<br />
&#8211; 4 analogue outputs<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital-optional</td>
</tr>
<tr>
<td align="justify">Memory</td>
<td colspan="2" align="center">&#8211; For 300 events (alarms, system errors, settings adjustments)</td>
</tr>
<tr>
<td align="justify">Indicators</td>
<td align="center">&#8211; Digital display for gas in ppb, ppm or %<br />
-Backlight<br />
-Alarm LED, availability of uses and errors</td>
<td align="center">&#8211; Digital display for 4 gases in ppb, ppm or %<br />
-Backlight<br />
-Alarm LED, availability of uses and errors</td>
</tr>
<tr>
<td align="justify">Alarm indicators</td>
<td colspan="2" align="center">Sound: 85 dB sharp beep<br />
Visual: alarm LED</td>
</tr>
<tr>
<td align="justify">Operating temperature range</td>
<td colspan="2" align="center">-10°C &#8230; +50°C<br />
+14°F &#8230; +122°F</td>
</tr>
<tr>
<td align="justify">Operating humidity range</td>
<td colspan="2" align="center">0 &#8230; 95% H.r. (non-condensed)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td colspan="2" align="center">90V &#8230; 264 VAC / 50 Hz &#8230; 60 Hz</td>
</tr>
<tr>
<td align="justify">Battery</td>
<td colspan="2" align="center">1.2 Ah</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td colspan="2" align="center">Steel exterior / ABS front panel</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td colspan="2" align="center">288 mm x 278 mm x 10 mm /<br />
11.3 in x 10.9 in x 0.4 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td colspan="2" align="center">4.5 kg / 9.9 lbs</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td colspan="2" align="center">EN 50270 (EMC), EN 61010-1 low voltage</td>
</tr>
<tr>
<td align="justify">Protection</td>
<td colspan="2" align="center">IP 54</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-plus-o2/">Oxygen Meter TXgard-Plus-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-plus-o2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15761</post-id>	</item>
		<item>
		<title>Oxygen Meter TXgard-IS+O2</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-iso2/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-iso2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 08:55:25 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15757</guid>

					<description><![CDATA[<p><strong>TXgard-IS+O2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-iso2/">Oxygen Meter TXgard-IS+O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>TXgard-IS+O2 Single-Gas Oxygen Meter<br />
warning for gases (Oxygen, O<sub>2</sub>, 0 &#8230; 25 vol%) / Features display and signal output / With ATEX or UL approval</strong></p>
<p align="justify">Here you can find an ATEX or UL approved Oxygen meter for flammable gases (ex), oxygen and toxic gases for fixed mounting. These Oxygen meters vary by the type of gases they measure, functionality (e.g. analogue output, relay output) or the type of indicator &#8211; there are sensors with a built-in screen (as an indicator) or without. You can choose a Oxygen meter for almost any type of gas: methane, propane, butane, pentane, LPG, ethanol, ethylene, nitrogen, acetylene, benzene (lead), phosphine, oxygen, ozone, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur dioxide, chlorine, ammonia (sensors for other types of gases can be requested). An Oxygen meter without a display (Xgard) are used in combination with an external indicator or a facility to detect gases, e.g. with the Gasmaster. Oxygen meters that operate without internal alarm relay can be used in conjunction with the GasFlag distributor.</p>
<p align="justify"><strong>Gas sensors</strong><br />
The series of sensors Xgard, TXgard, and Flamgard is always delivered calibrated and registered. By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</p>
<p align="justify"><strong>GasFlag</strong><br />
We offer the GasFlag for sensors without alarm relay. It is a small box for fixed installation without a display for signals for the input of 4… 20-mA. Its output has two alarm relays (max. 1 to 30V DC). The status is displayed through the LED, and it is powered to 230 V.</p>
<p align="justify"><strong>Gasmaster</strong><br />
The Gasmaster is a power station of gas detection with a large display. There are several versions: 1 and 4 channels as well as with or without an interface for the PC. The Gasmaster also possesses an alarm relay with which light signals or ventilators can be activated. The systems of the Gasmaster and the gas sensors are delivered configured, calibrated and verified.</p>
<p align="justify">&#8211; Stationary<br />
&#8211; For (Oxygen, O<sub>2</sub>, 0 &#8230; 25 vol%)<br />
&#8211; Additional display and alarm station<br />
&#8211; ATEX or UL approval</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical Specifications for the Xgard series sensors</strong></td>
</tr>
<tr>
<td>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center">Xgard-Type 1</td>
<td align="center">Xgard-Type 5</td>
<td align="center">TCgard</td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify">Types of gases to detect with corresponding measurement range<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">
<table width="150 %" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">O2</td>
<td align="center">0 &#8230; 25 vol%</td>
</tr>
<tr>
<td align="center">H<sub>2</sub></td>
<td align="center">0 &#8230; 2000 ppm<br />
0 &#8230; 4 vol%<br />
= (100% LEL)</td>
</tr>
<tr>
<td align="center">CO</td>
<td align="center">0 &#8230; 250 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">CL<sub>2</sub></td>
<td align="center">0 &#8230; 5 ppm</td>
</tr>
<tr>
<td align="center">O<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">SO<sub>2</sub></td>
<td align="center">0 &#8230; 10 ppm</td>
</tr>
<tr>
<td align="center">PH<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">NH<sub>3</sub></td>
<td align="center">0 &#8230; 50 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230;100 % UEG<br />
inflammable gases<br />
(methane, procloth, butane, pentane, LPG, ethanol, ethylene, etc.)<br />
By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</td>
<td align="center">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Methane</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub></td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">He</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">± 3%</td>
<td align="center">± 3%</td>
<td align="center">± 3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Signal output</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm/control relays</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C<br />
-4°F &#8230; +122°F</td>
<td align="center">-40°C &#8230; +55°C<br />
-40°F &#8230; +131°F</td>
<td align="center">+10°C &#8230; +55°C<br />
+50°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
<td align="center">Approx. 1 kg / 2.2 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications of the Xgard IR series gas sensors (with infrared measuring)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="2">
<tbody>
<tr>
<td align="justify"><span style="color: #003399">Optional components for the Xgard IR</span></td>
<td align="center"><span style="color: #003399">Xgard IR (infrared)</span></td>
<td align="center"><span style="color: #003399">Gas sensor type</span></td>
</tr>
<tr>
<td rowspan="13" align="justify" valign="top" width="35%">The response time of infrared gas sensors is T90 &lt; 30 s and zero drift is approx. ± 2% per month. For highly accurate measurements and protecting the sensors exterior, there are some optional protectors. Depending on the installation site, the protector against sunlight may be the perfect option. If the sensors are mounted outside (in the open field) or in halls and pavilions that are frequently cleaned with water or disinfected from time to time, we recommend the water deflector protector. When the sensor is mounted in high humidity environments or offshore applications and vessel installations, we recommend the gas sensor with the cap resistant to rain. The cone collector is often used when you need to detect light gases (e.g. methane). This facilitates the entry of the gas into the sensor. If you have any questions, contact us: <span style="color: #008000">+44 ( 0 ) 2380 98703 0</span></p>
<p><span style="color: #003399">Advantages to the conventional gas sensors:</span>The great advantage of infrared gas sensors is their long life ( &gt; 5 years) and almost inexistent long-term drift. This grealty lowers the cost of calibration. In addition, the sensors have a full temperature compensation. The ATEX, IECEx and UL norms allow them to be used worldwide.</td>
</tr>
<tr>
<td align="center">EX Zone</td>
<td align="center">1, 2, 21 / 22</td>
</tr>
<tr>
<td align="center">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">CO<sub>2</sub> 0 &#8230; 2%<br />
CO<sub>2</sub> 0 &#8230; 5%<br />
(according to sensor)<br />
0 &#8230; 100% LEL<br />
inflammable gases<br />
(Methane, propane, butane, pentane, LPG, ethanol, ethylene)</td>
</tr>
<tr>
<td align="center">Accuracy</td>
<td align="center">±2% (the whole range)</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Output signal</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Alarm / control relays</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">ATEX actual or UL</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP65 / IP66 with cap resistant to inclement weather</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">10V &#8230; 30V DC / 50-mA</td>
</tr>
<tr>
<td align="center">Temperature range</td>
<td align="center">-20ºC &#8230; +50ºC<br />
-4ºF &#8230; +122ºF</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">156 mm x 166 mm x 111 mm /<br />
6.1 in x 6.5 in x 4.4 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">1 kg / 2.2 lbs (aluminium housing)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>Technical Specifications of the TXgard series gas sensors</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center"><span style="color: #003399">TXgard IS+</span></td>
<td align="center"><span style="color: #003399">TXgard Plus</span></td>
<td align="center"><span style="color: #003399">Flamgard Plus</span></td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify" width="30%">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>O<sub>3</sub></td>
<td>0 &#8230; 1 ppm</td>
</tr>
<tr>
<td>NH<sub>3</sub></td>
<td>0 &#8230; 100 ppm</td>
</tr>
<tr>
<td>Cl<sub>2</sub></td>
<td>0 &#8230; 10 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub></td>
<td>0 &#8230; 2000 ppm</td>
</tr>
<tr>
<td>HCN</td>
<td>0 &#8230; 25 ppm</td>
</tr>
<tr>
<td>PH<sub>3</sub></td>
<td>0 &#8230; 2 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>ETO</td>
<td>0 &#8230; 10 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230; 100 % UEG<br />
Inflammable gases<br />
Acetylene (C2H2), ammonia (NH3), butane (C4H10), ethanol (C2H5OH), ethane (C2H6), ethylene (C2H4), hexane (C6H14), hydrogen (H2), LPG, methane (CH4), methanol (CH3OH), pentane (C5H12), steam oil, propane (C3H8), propanol (C3H8O)</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
</tr>
<tr>
<td align="justify">Output signal</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm / control relays</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">Yes</td>
<td align="center">Yes</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">11V &#8230; 30V DC / 20-mA</td>
<td align="center">10V &#8230; 30V DC / 210-mA</td>
<td align="center">10V &#8230; 30V DC / 210-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C<br />
-4°F &#8230; +122° F</td>
<td align="center">-10°C &#8230; +55°C<br />
+14°F &#8230; +131° F</td>
<td align="center">-10°C &#8230; +55°C<br />
+14°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">0.7 kg / 1.5 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasflag</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td rowspan="16" align="justify" width="30%">Warning station without display to connect one of the above sensors. This unit is usually mounted on the wall. When it exceeds the threshold value, it emits an alert tone and flashes a red alarm LED. A relay output can, for example, be connected to an omnidirectional illumination. The response time of the alarm is less than 1 sec. Threshold values can be adjusted. The alarm station is almost always used with a gas sensor. When it is not desired then the sensor itself makes the indication, and the alarm sounds.</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">1 sensor can be connected, 2 or 3 conductors</td>
</tr>
<tr>
<td align="center">Input</td>
<td align="center">4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Output</td>
<td align="center">Relay output with maximum 1 A,<br />
i.e. useful for multidirectional illumination</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">2 or 3 conductors / 4 mA &#8230; 20 mA</td>
</tr>
<tr>
<td align="center">LEDs indication</td>
<td align="center">Operating availability: green LED<br />
Difficulty: amber LED<br />
Limit is exceeded: 2 red LEDs</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
</tr>
<tr>
<td align="center">Operating temperature range</td>
<td align="center">-20°C &#8230; +70°C /<br />
-4°F &#8230; +158°F</td>
</tr>
<tr>
<td align="center">Operating humidity range</td>
<td align="center">0 &#8230; 99% R.H. non-condensed</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">13V &#8230; 28V DC</td>
</tr>
<tr>
<td align="center">Colour</td>
<td align="center">RAL7035</td>
</tr>
<tr>
<td align="center">Housing</td>
<td align="center">ABS plastic</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">210 mm x 145 mm x 46 mm /<br />
8.3 in x 5.7 in x 1.8 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">0.5 kg / 1.1 lbs</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">EN 50270/EMC</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP 20</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasmaster (1 &#8211; 4 gas sensors)</strong></td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td colspan="3" align="justify">Digital display and control panel for gas sensors described above. There are two Gasmaster models: GM 1 for a GM sensor, and 4 for up to 4 sensors (shows 4 values at one time). In addition to the standard analogue output, both types are available with an RS 232 data interface. The device also has relay outputs to activate a multidirectional light. The housing of the apparatus is protected against dust and splashing water. The unit is standard equipped with a battery so it will continue operating in case of a power failure.</td>
</tr>
<tr>
<td align="justify">Model</td>
<td align="center">GM 1</td>
<td align="center">GM 4</td>
</tr>
<tr>
<td align="justify">Sensors inputs</td>
<td align="center">1 input for one of the gas sensors</td>
<td align="center">4 inputs for 4 gas sensors</td>
</tr>
<tr>
<td align="justify">Outputs</td>
<td align="center">&#8211; 1 relay output<br />
(250 VAC/8 A)<br />
&#8211; 1 analogue output<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital -optional</td>
<td align="center">&#8211; 4 relay outputs<br />
(250 VAC/8 A)<br />
&#8211; 4 analogue outputs<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital-optional</td>
</tr>
<tr>
<td align="justify">Memory</td>
<td colspan="2" align="center">for 300 events (alarms, system errors, settings adjustments)</td>
</tr>
<tr>
<td align="justify">Indicators</td>
<td align="center">&#8211; Digital display for gas in ppb, ppm or %<br />
-Backlight<br />
-Alarm LED, availability of uses and errors</td>
<td align="center">&#8211; Digital display for 4 gases in ppb, ppm or %<br />
-backlight<br />
-Alarm LED, availability of uses and errors</td>
</tr>
<tr>
<td align="justify">Alarm indicators</td>
<td colspan="2" align="center">Sound: 85 dB sharp beep<br />
Visual: alarm LED</td>
</tr>
<tr>
<td align="justify">Operating temperature range</td>
<td colspan="2" align="center">-10°C &#8230; +50°C /<br />
+14°F &#8230; +122°F</td>
</tr>
<tr>
<td align="justify">Operating humidity range</td>
<td colspan="2" align="center">0 &#8230; 95% H.r. (non-condensed)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td colspan="2" align="center">90V &#8230; 264 VAC / 50 Hz &#8230; 60 Hz</td>
</tr>
<tr>
<td align="justify">Battery</td>
<td colspan="2" align="center">1.2 Ah</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td colspan="2" align="center">steel exterior / ABS front panel</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td colspan="2" align="center">288 mm x 278 mm x 10 mm /<br />
11.3 in x 10.9 in x 0.4 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td colspan="2" align="center">4.5 kg / 9.9 lbs</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td colspan="2" align="center">EN 50270 (EMC), EN 61010-1 low voltage</td>
</tr>
<tr>
<td align="justify">Protection</td>
<td colspan="2" align="center">IP 54</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-iso2/">Oxygen Meter TXgard-IS+O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-txgard-iso2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15757</post-id>	</item>
		<item>
		<title>Oxygen Meter Xgard-Typ-1-O2</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-xgard-typ-1-o2/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-xgard-typ-1-o2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 08:25:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15755</guid>

					<description><![CDATA[<p><strong>Xgard-1-O2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-xgard-typ-1-o2/">Oxygen Meter Xgard-Typ-1-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Xgard-1-O2 Single-Gas Gassensor<br />
warning for gases (Oxygen, O<sub>2</sub>, 0 &#8230; 25 vol%) / Features display and signal output / With ATEX or UL approval</strong></p>
<p align="justify">Here you can find an ATEX or UL approved Gassensor for flammable gases (ex), oxygen and toxic gases for fixed mounting. These Gassensors vary by the type of gases they measure, functionality (e.g. analogue output, relay output) or the type of indicator &#8211; there are sensors with a built-in screen (as an indicator) or without. You can choose a Gassensor for almost any type of gas: methane, propane, butane, pentane, LPG, ethanol, ethylene, nitrogen, acetylene, benzene (lead), phosphine, oxygen, ozone, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur dioxide, chlorine, ammonia (sensors for other types of gases can be requested). A Gassensor without a display (Xgard) are used in combination with an external indicator or a facility to detect gases, e.g. with the Gasmaster. Gassensors that operate without internal alarm relay can be used in conjunction with the GasFlag distributor.</p>
<p align="justify"><strong>Gas sensors</strong><br />
The series of sensors Xgard, TXgard, and Flamgard is always delivered calibrated and registered. By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</p>
<p align="justify"><strong>GasFlag</strong><br />
We offer the GasFlag for sensors without alarm relay. It is a small box for fixed installation without a display for signals for the input of 4… 20 mA. Its output has two alarm relays (max. 1 to 30 V DC). The status is displayed through the LED, and it is powered to 230 V.</p>
<p align="justify"><strong>Gasmaster</strong><br />
The Gasmaster is a power station of gas detection with a large display. There are several versions: 1 and 4 channels as well as with or without an interface for the PC. The Gasmater also possesses an alarm relay with which light signals or ventilators can be activated. The systems of the Gasmaster and the gas sensors are delivered configured, calibrated and verified.</p>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="justify"><strong>Technical Specifications for the Xgard series sensors</strong></td>
</tr>
<tr>
<td>
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center">Xgard-Type 1</td>
<td align="center">Xgard-Type 5</td>
<td align="center">TCgard</td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify">Types of gases to detect with corresponding measurement range<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">
<table width="150 %" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">O<sub>2</sub></td>
<td align="center">0 &#8230; 25 vol%</td>
</tr>
<tr>
<td align="center">H<sub>2</sub></td>
<td align="center">0 &#8230; 2000 ppm<br />
0 &#8230; 4 vol%<br />
= (100% LEL)</td>
</tr>
<tr>
<td align="center">CO</td>
<td align="center">0 &#8230; 250 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">H<sub>2</sub>S</td>
<td align="center">0 &#8230; 25 ppm</td>
</tr>
<tr>
<td align="center">CL<sub>2</sub></td>
<td align="center">0 &#8230; 5 ppm</td>
</tr>
<tr>
<td align="center">O<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">SO<sub>2</sub></td>
<td align="center">0 &#8230; 10 ppm</td>
</tr>
<tr>
<td align="center">PH<sub>3</sub></td>
<td align="center">0 &#8230; 1 ppm</td>
</tr>
<tr>
<td align="center">NH<sub>3</sub></td>
<td align="center">0 &#8230; 50 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230;100 % UEG<br />
inflammable gases<br />
(methane, procloth, butane, pentane, LPG, ethanol, ethylene, etc.)<br />
By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.</td>
<td align="center">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Methane</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub></td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
<tr>
<td align="center">He</td>
<td align="center">0 &#8230; 100 vol%</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">± 3%</td>
<td align="center">± 3%</td>
<td align="center">± 3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Signal output</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm/control relays</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
<td align="center">&#8211; &#8211; &#8211;</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
<td align="center">8 &#8230; 30V DC / 24-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C<br />
-4°F &#8230; +122°F</td>
<td align="center">-40°C &#8230; +55°C<br />
-40°F &#8230; +131°F</td>
<td align="center">+10° C &#8230; +55°C<br />
+50°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">approx. 1 kg / 2.2 lbs</td>
<td align="center">approx. 1 kg / 2.2 lbs</td>
<td align="center">approx. 1 kg / 2.2 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications of the Xgard IR series gas sensors (with infrared measuring)</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="2">
<tbody>
<tr>
<td align="justify"><span style="color: #003399">Optional components for the Xgard IR</span></td>
<td align="center"><span style="color: #003399">Xgard IR (infrared)</span></td>
<td align="center"><span style="color: #003399">Gas sensor type</span></td>
</tr>
<tr>
<td rowspan="13" align="justify" valign="top" width="35%">The response time of infrared gas sensors is T90 &lt; 30 s and zero drift is approx. ± 2% per month. For highly accurate measurements and protecting the sensors exterior, there are some optional protectors. Depending on the installation site, the protector against sunlight may be the perfect option. If the sensors are mounted outside (in the open field) or in halls and pavilions that are frequently cleaned with water or disinfected from time to time, we recommend the water deflector protector. When the sensor is mounted in high humidity environments or offshore applications and vessel installations, we recommend the gas sensor with the cap resistant to rain. The cone collector is often used when you need to detect light gases (e.g. methane). This facilitates the entry of the gas into the sensor. If you have any questions, contact us: <span style="color: #008000">+44 ( 0 ) 2380 98703 0</span></p>
<p><span style="color: #003399">Advantages to the conventional gas sensors:</span>The great advantage of infrared gas sensors is their long life ( &gt; 5 years) and almost inexistent long-term drift. This grealty lowers the cost of calibration. In addition, the sensors have a full temperature compensation. The ATEX, IECEx and UL norms allow them to be used worldwide.</td>
</tr>
<tr>
<td align="center">EX Zone</td>
<td align="center">1, 2, 21 / 22</td>
</tr>
<tr>
<td align="center">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center">CO<sub>2</sub> 0 &#8230; 2%<br />
CO<sub>2</sub> 0 &#8230; 5%<br />
(according to sensor)<br />
0 &#8230; 100% LEL<br />
inflammable gases<br />
(Methane, propane, butane, pentane, LPG, ethanol, ethylene)</td>
</tr>
<tr>
<td align="center">Accuracy</td>
<td align="center">±2% (the whole range)</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Output signal</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Alarm / control relays</td>
<td align="center">&#8212;-</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">ATEX actual or UL</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP65 / IP66 with cap resistant to inclement weather</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">10V &#8230; 30V DC / 50-mA</td>
</tr>
<tr>
<td align="center">Temperature range</td>
<td align="center">-20ºC &#8230; +50ºC<br />
-4ºF &#8230; +122ºF</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">156 mm x 166 mm x 111 mm /<br />
6.1 in x 6.5 in x 4.4 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">1 kg / 2.2 lbs (aluminium housing)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify"><strong>Technical Specifications of the TXgard series gas sensors</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td align="center">Gas sensor type</td>
<td align="center"><span style="color: #003399">TXgard IS+</span></td>
<td align="center"><span style="color: #003399">TXgard Plus</span></td>
<td align="center"><span style="color: #003399">Flamgard Plus</span></td>
</tr>
<tr>
<td align="justify">EX Zone</td>
<td align="center">0, 1, 2</td>
<td align="center">1, 2</td>
<td align="center">1, 2</td>
</tr>
<tr>
<td align="justify" width="30%">Types of gases to detect with the corresponding range of measurement<br />
(you will find the required order code for the types of gases in the online store)</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>O<sub>3</sub></td>
<td>0 &#8230; 1 ppm</td>
</tr>
<tr>
<td>NH<sub>3</sub></td>
<td>0 &#8230; 100 ppm</td>
</tr>
<tr>
<td>Cl<sub>2</sub></td>
<td>0 &#8230; 10 ppm</td>
</tr>
<tr>
<td>H<sub>2</sub></td>
<td>0 &#8230; 2000 ppm</td>
</tr>
<tr>
<td>HCN</td>
<td>0 &#8230; 25 ppm</td>
</tr>
<tr>
<td>PH<sub>3</sub></td>
<td>0 &#8230; 2 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center" width="10%">
<table>
<tbody>
<tr>
<td>O<sub>2</sub></td>
<td>0 &#8230; 25 vol%</td>
</tr>
<tr>
<td>H<sub>2</sub>S</td>
<td>0 &#8230; 50 ppm</td>
</tr>
<tr>
<td>CO</td>
<td>0 &#8230; 500 ppm</td>
</tr>
<tr>
<td>ETO</td>
<td>0 &#8230; 10 ppm</td>
</tr>
</tbody>
</table>
</td>
<td align="center">0 &#8230; 100% UEG<br />
inflammable gases<br />
Acetylene (C2H2), ammonia (NH3), butane (C4H10), ethanol (C2H5OH), ethane (C2H6), ethylene (C2H4), hexane (C6H14), hydrogen (H2), LPG, methane (CH4), methanol (CH3OH), pentane (C5H12), steam oil, propane (C3H8), propanol (C3H8O)</td>
</tr>
<tr>
<td align="justify">Accuracy</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
<td align="center">±3%</td>
</tr>
<tr>
<td align="justify">Display</td>
<td align="center">yes</td>
<td align="center">yes</td>
<td align="center">yes</td>
</tr>
<tr>
<td align="justify">Output signal</td>
<td align="center">2 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
<td align="center">3 conductors<br />
4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="justify">Alarm / control relays</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
<td align="center">yes</td>
<td align="center">yes</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
<td align="center">ATEX or UL</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td align="center">11V &#8230; 30 V DC / 20-mA</td>
<td align="center">10V &#8230; 30 V DC / 210-mA</td>
<td align="center">10V &#8230; 30V DC / 210-mA</td>
</tr>
<tr>
<td align="justify">Temperature range</td>
<td align="center">-20°C &#8230; +50°C<br />
-4°F &#8230; +122°F</td>
<td align="center">-10°C &#8230; +55°C<br />
+14°F &#8230; +131°F</td>
<td align="center">-10°C &#8230; +55°C<br />
+14°F &#8230; +131°F</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td align="center">0.7 kg / 1.5 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
<td align="center">2.2 kg / 4.9 lbs</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasflag</strong></td>
</tr>
<tr>
<td align="justify">
<table cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td rowspan="16" align="justify" width="30%">Warning station without display to connect one of the above sensors. This unit is usually mounted on the wall. When it exceeds the threshold value, it emits an alert tone and flashes a red alarm LED. A relay output can, for example, be connected to an omnidirectional illumination. The response time of the alarm is less than 1 sec. Threshold values can be adjusted. The alarm station is almost always used with a gas sensor. When it is not desired then the sensor itself makes the indication, and the alarm sounds.</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">1 sensor can be connected, 2 or 3 conductors</td>
</tr>
<tr>
<td align="center">Input</td>
<td align="center">4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">Output</td>
<td align="center">Relay output with maximum 1 A,<br />
i.e. useful for multidirectional illumination</td>
</tr>
<tr>
<td align="center">Sensor connection</td>
<td align="center">2 or 3 conductors / 4-mA &#8230; 20-mA</td>
</tr>
<tr>
<td align="center">LEDs indication</td>
<td align="center">Operating availability: green LED<br />
Difficulty: amber LED<br />
Limit is exceeded: 2 red LEDs</td>
</tr>
<tr>
<td align="center">Display</td>
<td align="center"><strong>&#8211; &#8211; &#8211;</strong></td>
</tr>
<tr>
<td align="center">Operating temperature range</td>
<td align="center">-20°C &#8230; +70°C<br />
-4°F &#8230; +158°F</td>
</tr>
<tr>
<td align="center">Operating humidity range</td>
<td align="center">0 &#8230; 99% R.H. non-condensed</td>
</tr>
<tr>
<td align="center">Power supply</td>
<td align="center">13V &#8230; 28V DC</td>
</tr>
<tr>
<td align="center">Colour</td>
<td align="center">RAL7035</td>
</tr>
<tr>
<td align="center">Housing</td>
<td align="center">ABS plastic</td>
</tr>
<tr>
<td align="center">Dimensions</td>
<td align="center">210 mm x 145 mm x 46 mm /<br />
8.3 in x 5.7 in x 1.8 in</td>
</tr>
<tr>
<td align="center">Weight</td>
<td align="center">0.5 kg / 1.1 lbs</td>
</tr>
<tr>
<td align="center">Norms</td>
<td align="center">EN 50270/EMC</td>
</tr>
<tr>
<td align="center">Protection</td>
<td align="center">IP 20</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td align="justify">
<strong>Technical Specifications for the Gasmaster (1 &#8211; 4 gas sensors)</strong></td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td colspan="3" align="justify">Digital display and control panel for gas sensors described above. There are two Gasmaster models: GM 1 for a GM sensor, and 4 for up to 4 sensors (shows 4 values at one time). In addition to the standard analogue output, both types are available with an RS 232 data interface. The device also has relay outputs to activate a multidirectional light. The housing of the apparatus is protected against dust and splashing water. The unit is standard equipped with a battery so it will continue operating in case of a power failure.</td>
</tr>
<tr>
<td align="justify">Model</td>
<td align="center">GM 1</td>
<td align="center">GM 4</td>
</tr>
<tr>
<td align="justify">Sensors inputs</td>
<td align="center">1 input for one of the gas sensors</td>
<td align="center">4 inputs for 4 gas sensors</td>
</tr>
<tr>
<td align="justify">Outputs</td>
<td align="center">&#8211; 1 relay output<br />
(250 VAC/8 A)<br />
&#8211; 1 analogue output<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital -optional</td>
<td align="center">&#8211; 4 relay outputs<br />
(250 VAC/8 A)<br />
&#8211; 4 analogue outputs<br />
(4 &#8230; 20-mA)<br />
&#8211; 1 RS 485 digital<br />
&#8211; 1 RS 232 digital-optional</td>
</tr>
<tr>
<td align="justify">Memory</td>
<td colspan="2" align="center">for 300 events (alarms, system errors, settings adjustments)</td>
</tr>
<tr>
<td align="justify">Indicators</td>
<td align="center">&#8211; digital display for gas in ppb, ppm or %<br />
-backlight<br />
-alarm LED, availability of uses and errors</td>
<td align="center">&#8211; digital display for 4 gases in ppb, ppm or %<br />
-backlight<br />
-alarm LED, availability of uses and errors</td>
</tr>
<tr>
<td align="justify">Alarm indicators</td>
<td colspan="2" align="center">Sound: 85 dB sharp beep<br />
Visual: alarm LED</td>
</tr>
<tr>
<td align="justify">Operating temperature range</td>
<td colspan="2" align="center">-10°C &#8230; +50°C<br />
+14°F &#8230; +122°F</td>
</tr>
<tr>
<td align="justify">Operating humidity range</td>
<td colspan="2" align="center">0 &#8230; 95% H.r. (non-condensed)</td>
</tr>
<tr>
<td align="justify">Power supply</td>
<td colspan="2" align="center">90V &#8230; 264 VAC / 50 Hz &#8230; 60 Hz</td>
</tr>
<tr>
<td align="justify">Battery</td>
<td colspan="2" align="center">1.2 Ah</td>
</tr>
<tr>
<td align="justify">Housing</td>
<td colspan="2" align="center">Steel exterior / ABS front panel</td>
</tr>
<tr>
<td align="justify">Dimensions</td>
<td colspan="2" align="center">288 mm x 278 mm x 10 mm /<br />
11.3 in x 10.9 in x 0.4 in</td>
</tr>
<tr>
<td align="justify">Weight</td>
<td colspan="2" align="center">4.5 kg / 9.9 lbs</td>
</tr>
<tr>
<td align="justify">Norms</td>
<td colspan="2" align="center">EN 50270 (EMC), EN 61010-1 low voltage</td>
</tr>
<tr>
<td align="justify">Protection</td>
<td colspan="2" align="center">IP 54</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-xgard-typ-1-o2/">Oxygen Meter Xgard-Typ-1-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-xgard-typ-1-o2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15755</post-id>	</item>
		<item>
		<title>Oxygen Meter PCE-WMM 100-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 07:54:42 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15752</guid>

					<description><![CDATA[<p><strong>PCE-WMM 100-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100-ica-incl-iso-calibration-certificate/">Oxygen Meter PCE-WMM 100-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Oxygen Meter </strong><strong>PCE-WMM 100-ICA incl. ISO Calibration Certificate</strong></div>
<div style="text-align: center"><strong>CO2 warning device for carbon dioxide and oxygen / Adjustable alarms / 4-digit LC display / Consisting of main and remote unit / Relay contacts / Analog output</strong></div>
<div></div>
<div>The CO2 warning device PCE-WMM 100 consists of a main unit and a remote display. The CO2 gas detector PCE-WMM 100 is used to measure carbon dioxide and oxygen in a fixed location. The CO2 warning device protects people from the odourless gas CO2 and also warns of low oxygen content in the air. The gas warning system displays the measured values on an LCD. The PCE-WMM 100 CO2 warning device has two relays that can be used to control alarm lights or sounders. Furthermore, the CO2 warning device has an integrated, acoustic alarm, which emits an audio signal of 80 db in the event of an alarm.</div>
<div></div>
<div>The warning device is used wherever CO2 can be released. This can be in warehouses, breweries, wine cellars or restaurants. The main unit is protected to IP54. 4 LEDs on the front provide information about the system status.</div>
<div></div>
<div>&#8211; CO2 and O2 sensor</div>
<div>&#8211; <span lang="en">Main and remote unit</span></div>
<div>&#8211; Alarm relay</div>
<div>&#8211; 4 &#8230; 20 mA analog output</div>
<div>&#8211; Acoustic alarm</div>
<div>&#8211; Integrated temperature measurement</p>
<div>&#8211; incl. ISO Calibration Certificate</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>CO2</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230;. 50000 ppm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">&lt;10000 ppm: 10 ppm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">&gt;10001 ppm: 100 ppm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 100 ppm / 5 % of measured value</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>O2</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">O2: 0 &#8230; 30 %</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 %</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">&lt; 3 % of measured value</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Temperature</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 50 °C / 32 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 °C</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 1 °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Repeatability</td>
<td valign="top">CO2: ±20 ppm at 400 ppm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: &lt; ±1 %</td>
</tr>
<tr>
<td valign="top">Temperature dependence</td>
<td valign="top">± 0.3 % of measured value / °C</td>
</tr>
<tr>
<td valign="top">(at 25 °C)</td>
<td valign="top">± 2 ppm / °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(the larger value applies)</td>
</tr>
<tr>
<td valign="top">Pressure dependence</td>
<td valign="top">0.13 % of measured value / mmHg</td>
</tr>
<tr>
<td valign="top">Response time</td>
<td valign="top">CO2: T90 &lt; 60s</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: T90 &lt; 30s</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Temperature: 20 &#8230; 30 m</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm 1</td>
<td valign="top">CO2: 5000 ppm, 1 %, 1.5 %, 2 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: 18 %, 18.5 %, 19 %, 19.5 %, 20 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm 2</td>
<td valign="top">CO2: 1.5 %, 2 %, 2.5 %, 3 %, 3.5 %, 4 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: 16 %, 16.5 %, 17 %, 17.5 %, 18 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm sound volume</td>
<td valign="top">80 db / 0.1 m</td>
</tr>
<tr>
<td valign="top">Heating time</td>
<td valign="top">&lt; 60 s at 22 °C ambient temperature</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">Power adapter 100 &#8230; 240 V AC / 6 V DC / 0.5 A</td>
</tr>
<tr>
<td valign="top">Analog output</td>
<td valign="top">2 x 4 &#8230; 20 mA</td>
</tr>
<tr>
<td valign="top">Load</td>
<td valign="top">&lt;150 Ohm</td>
</tr>
<tr>
<td valign="top">Relay</td>
<td valign="top">max. 2 A / 30 V DC / 250 V AC</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; 40 °C / 32 &#8230; 104 °F / max 95 % r.H.</td>
</tr>
<tr>
<td valign="top">Storage conditions</td>
<td valign="top">-20 &#8230; 60 °C / -4 &#8230; 140 °F / max. 95 % r.H.</td>
</tr>
<tr>
<td valign="top">Degree of protection</td>
<td valign="top">Main unit: IP54</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: &#8211;</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">Main unit: 170 x 63 x 26 mm / 6.6 x 2.4 x 1.0&#8243;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: 80 x 35.7 x 10 mm / 3.1 x 1.4 x 0.3&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">Main unit: 1200 g incl cable</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: 120 g / 4.2 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100-ica-incl-iso-calibration-certificate/">Oxygen Meter PCE-WMM 100-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15752</post-id>	</item>
		<item>
		<title>Oxygen Meter PCE-WMM 100</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 07:25:42 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15750</guid>

					<description><![CDATA[<p><strong>PCE-WMM 100</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100/">Oxygen Meter PCE-WMM 100</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Oxygen Meter </strong><strong>PCE-WMM 100</strong></div>
<div style="text-align: center"><strong>CO2 warning device for carbon dioxide and oxygen / Adjustable alarms / 4-digit LC display / Consisting of main and remote unit / Relay contacts / Analog output</strong></div>
<div></div>
<div>The CO2 warning device PCE-WMM 100 consists of a main unit and a remote display. The CO2 gas detector PCE-WMM 100 is used to measure carbon dioxide and oxygen in a fixed location. The CO2 warning device protects people from the odourless gas CO2 and also warns of low oxygen content in the air. The gas warning system displays the measured values on an LCD. The PCE-WMM 100 CO2 warning device has two relays that can be used to control alarm lights or sounders. Furthermore, the CO2 warning device has an integrated, acoustic alarm, which emits an audio signal of 80 db in the event of an alarm.</div>
<div></div>
<div>The warning device is used wherever CO2 can be released. This can be in warehouses, breweries, wine cellars or restaurants. The main unit is protected to IP54. 4 LEDs on the front provide information about the system status.</div>
<div></div>
<div>&#8211; CO2 and O2 sensor</div>
<div>&#8211; <span lang="en">Main and remote unit</span></div>
<div>&#8211; Alarm relay</div>
<div>&#8211; 4 &#8230; 20 mA analog output</div>
<div>&#8211; Acoustic alarm</div>
<div>&#8211; Integrated temperature measurement</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>CO2</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230;. 50000 ppm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">&lt;10000 ppm: 10 ppm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">&gt;10001 ppm: 100 ppm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 100 ppm / 5 % of measured value</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>O2</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">O2: 0 &#8230; 30 %</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 %</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">&lt; 3 % of measured value</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Temperature</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 50 °C / 32 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 °C</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 1 °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Repeatability</td>
<td valign="top">CO2: ±20 ppm at 400 ppm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: &lt; ±1 %</td>
</tr>
<tr>
<td valign="top">Temperature dependence</td>
<td valign="top">± 0.3 % of measured value / °C</td>
</tr>
<tr>
<td valign="top">(at 25 °C)</td>
<td valign="top">± 2 ppm / °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(the larger value applies)</td>
</tr>
<tr>
<td valign="top">Pressure dependence</td>
<td valign="top">0.13 % of measured value / mmHg</td>
</tr>
<tr>
<td valign="top">Response time</td>
<td valign="top">CO2: T90 &lt; 60s</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: T90 &lt; 30s</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Temperature: 20 &#8230; 30 m</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm 1</td>
<td valign="top">CO2: 5000 ppm, 1 %, 1.5 %, 2 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: 18 %, 18.5 %, 19 %, 19.5 %, 20 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm 2</td>
<td valign="top">CO2: 1.5 %, 2 %, 2.5 %, 3 %, 3.5 %, 4 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">O2: 16 %, 16.5 %, 17 %, 17.5 %, 18 %</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Alarm sound volume</td>
<td valign="top">80 db / 0.1 m</td>
</tr>
<tr>
<td valign="top">Heating time</td>
<td valign="top">&lt; 60 s at 22 °C ambient temperature</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">Power adapter 100 &#8230; 240 V AC / 6 V DC / 0.5 A</td>
</tr>
<tr>
<td valign="top">Analog output</td>
<td valign="top">2 x 4 &#8230; 20 mA</td>
</tr>
<tr>
<td valign="top">Load</td>
<td valign="top">&lt;150 Ohm</td>
</tr>
<tr>
<td valign="top">Relay</td>
<td valign="top">max. 2 A / 30 V DC / 250 V AC</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; 40 °C / 32 &#8230; 104 °F / max 95 % r.H.</td>
</tr>
<tr>
<td valign="top">Storage conditions</td>
<td valign="top">-20 &#8230; 60 °C / -4 &#8230; 140 °F / max. 95 % r.H.</td>
</tr>
<tr>
<td valign="top">Degree of protection</td>
<td valign="top">Main unit: IP54</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: &#8211;</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">Main unit: 170 x 63 x 26 mm / 6.6 x 2.4 x 1.0&#8243;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: 80 x 35.7 x 10 mm / 3.1 x 1.4 x 0.3&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">Main unit: 1200 g incl cable</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Remote unit: 120 g / 4.2 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100/">Oxygen Meter PCE-WMM 100</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-wmm-100/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15750</post-id>	</item>
		<item>
		<title>Dissolved Oxygen Meter PCE-WO2 10</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-wo2-10/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-wo2-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 07:22:35 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15748</guid>

					<description><![CDATA[<p><strong>PCE-WO2 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-wo2-10/">Dissolved Oxygen Meter PCE-WO2 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Oxygen meter PCE-WO2 10</strong></div>
<div style="text-align: center"><strong>waterproof oxygen meter with HOLD function / </strong></div>
<div style="text-align: center"><strong>testing of oxygen content, oxygen saturation and sample temperature in water / </strong><strong>battery operation / automatic temperature compensation</strong></div>
<div></div>
<div>The oxygen meter is a simple measuring instrument that allows measurement of oxygen content, oxygen saturation and sample temperature. The oxygen meter directly reports measured values in real time via the display. The user is offered a hold function directly on the device. Important measured values can be recorded at the touch of a button directly on the display.</div>
<div></div>
<div>The oxygen content is the concentration of dissolved oxygen in the water. Most organisms require a minimum concentration of dissolved oxygen in the water to live. Oxygen is absorbed from the atmosphere, whereby the oxygen uptake mainly depends on the size of the water surface, the water temperature, the saturation deficit, the water turbulence and the air movement.</div>
<div></div>
<div>The simple operation of the oxygen meter takes place via three buttons on the front. Due to the battery operation, the oxygen meter is suitable for mobile use. This is the main reason why the oxygen meter is indispensable in the analysis of different waters. This includes industrial wastewater, pond water, sewage and municipal wastewater. In addition to the above applications, the oxygen meter PCE-WO2 10 also plays an important role in businesses. Here, for example, the corrosion in pipelines has to be considered. Even in the private sector, an oxygen meter is getting more and more attention in fields such as fish farming or private aquaristics.</div>
<div></div>
<div>&#8211; robust housing<br />
&#8211; for mobile use<br />
&#8211; HOLD function<br />
&#8211; temperature, salt and altitude compensation<br />
&#8211; 1 or 2-point calibration<br />
&#8211; automatic shutdown</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td>Measuring range oxygen content</td>
<td>0.0 &#8230; 20.0 mg/l</td>
</tr>
<tr>
<td>Resolution oxygen content</td>
<td>0.1 mg/l</td>
</tr>
<tr>
<td>Measuring accuracy oxygen content</td>
<td>±0.5 mg/l</td>
</tr>
<tr>
<td>Measuring range oxygen saturation</td>
<td>0.0 &#8230; 200.0 %</td>
</tr>
<tr>
<td>Resolution oxygen saturation</td>
<td>0.1 %</td>
</tr>
<tr>
<td>Measuring accuracy of oxygen saturation</td>
<td>±2.0 %</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>0 &#8230; +40 °C / 32 &#8230; 104 °F, automatic</td>
</tr>
<tr>
<td>Air pressure correction</td>
<td>60.0 &#8230; 112.5 kPa, 450 &#8230;850 mmHg</td>
</tr>
<tr>
<td>Salinity correction</td>
<td>0 &#8230; 35 g/l</td>
</tr>
<tr>
<td>Sensor type</td>
<td>polarography</td>
</tr>
<tr>
<td>Environmental conditions</td>
<td>0 &#8230; +60 °C / 32 &#8230; 140 °F, max. 80 % r.H.</td>
</tr>
<tr>
<td>Power supply</td>
<td>2 x 1.5 AAA batteries</td>
</tr>
<tr>
<td>Dimension (length x radius)</td>
<td>175 x 40 mm / 6.8 x 1.5&#8243;</td>
</tr>
<tr>
<td>Weight</td>
<td>100 g / 3.5 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-wo2-10/">Dissolved Oxygen Meter PCE-WO2 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-wo2-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15748</post-id>	</item>
		<item>
		<title>Dissolved Oxygen Meter PCE-PHD 1-O2</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1-o2/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1-o2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Mar 2021 07:24:12 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15742</guid>

					<description><![CDATA[<p><strong>PCE-PHD 1-O2</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1-o2/">Dissolved Oxygen Meter PCE-PHD 1-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>PCE-PHD 1-O2 </strong><strong>Dissolved Oxygen Meter</strong></div>
<div style="text-align: center"><strong>SD card memory (1 &#8230; 16 GB), stored data is stored as an Excel file / large, easy-to-read display / RS-232 interface and optional software for direct transfer to the PC / Includes an oxygen electrode</strong></div>
</div>
<div>
<p align="justify">PCE-PHD 1-O2 Dissolved Oxygen Meter is a portable, easy-to-use measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the Dissolved Oxygen Meter is used for laboratory and <em>in situ</em> testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water.</p>
<p align="justify">Temperature compensation guarantee a high level of accuracy even with variable temperature measurements. PCE-PHD 1-O2 is supplied with an <strong>oxygen </strong>electrode. Additional electrodes are available for purchase separately, as is an optional mains adapter for power and a software kit with an RS-232 cable. PCE-PHD 1-O2 acts as a real-time data logger. All values can be stored directly on the included SD card in Microsoft Excel format or transferred to a PC by means of the RS-232 port. Thus, no additional software is required for evaluation of the data.</p>
</div>
<div>
<div>&#8211; Real-time data logger<br />
&#8211; Compatibility with SD cards up to 16 GB<br />
&#8211; The stored data is saved directly as an Excel file on the SD card (no software needed for evaluation)<br />
&#8211; RS-232 interface for online data transmission<br />
&#8211; High precision<br />
&#8211; Low battery indication<br />
&#8211; Large LC display<br />
&#8211; Adjustable measuring rate<br />
&#8211; Easy to use<br />
&#8211; Robust housing<br />
&#8211; Automatic calibration<br />
&#8211; Manual or automatic temperature compensation<br />
&#8211; BNC connector<br />
&#8211; Suitable for laboratory and suburban measurement<br />
&#8211; Electrode for <strong>oxygen </strong>included</div>
</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong>Oxygen</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 20 mg/l (in water)<br />
0 &#8230; 100 % (in air)<br />
0 &#8230; 50 °C</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 mg/l<br />
0.1 %<br />
0.1 °C</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">
<table border="0" cellspacing="0" bgcolor="#ffffff">
<tbody>
<tr>
<td valign="top"></td>
<td valign="top">± 0.4 mg/l<br />
± 0.7 %<br />
± 0.8 °C</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">in the air</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 50 ºC / 32 ºF &#8230; 122 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>General specifications</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement rate</td>
<td valign="top">1 second up to 8 hrs 59 mins 59 secs</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">LCD 52 x 38 mm / 2 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Memory</td>
<td valign="top">SD card up to 16 GB (2 GB card included)</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">RS-232</td>
</tr>
<tr>
<td valign="top">Software</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">6 x 1.5 V AA batteries (optional power adapter)</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; +50 ºC / &lt; 85 % RH</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">177 x 68 x 45 mm / 7.0 x 2.7 x 1.8&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">490 g / 1.1 lbs</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1-o2/">Dissolved Oxygen Meter PCE-PHD 1-O2</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1-o2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15742</post-id>	</item>
		<item>
		<title>Dissolved Oxygen Meter PCE-PHD 1</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Mar 2021 07:09:45 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15723</guid>

					<description><![CDATA[<p><strong>PCE-PHD 1</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1/">Dissolved Oxygen Meter PCE-PHD 1</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>PCE-PHD 1 Dissolved Oxygen Meter</strong><br />
<strong>pH value, redox, conductivity, salt, oxygen and temperature measuring device / SD card memory (1 &#8230; 16 GB), data is saved as an Excel file / large, easy-to-read display / RS-232 interface and optional software for direct transfer to the PC</strong></div>
<div>
<p align="justify">The Dissolved Oxygen Meter is a portable, easy-to-use measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the Oxygen Meter is used for laboratory and <em>in situ</em> testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water.</p>
<p align="justify">Three-point calibration and automatic temperature compensation guarantee a high level of accuracy even with variable temperature measurements. This meter is supplied with both a pH electrode and a conductivity electrode. Additional electrodes are available for purchase separately, as is an optional mains adapter for power and a software kit with an RS-232 cable. This meter acts as a real-time data logger. All values can be stored directly on the included SD card in Microsoft Excel format or transferred to a PC by means of the RS-232 port. Thus, no additional software is required for evaluation of the data.</p>
</div>
<p>&#8211; Optimal price / performance ratio<br />
&#8211; Real-time data logger<br />
&#8211; SD card memory (1 &#8230; 16 GB)<br />
&#8211; The saved data is saved directly as an Excel file on the SD card (for evaluation, no software is required)<br />
&#8211; RS-232 interface for online data transfer<br />
&#8211; Measures pH value, redox, conductivity, salt content, oxygen, and temperature<br />
&#8211; High precision<br />
&#8211; Low battery display<br />
&#8211; Large LC display<br />
&#8211; Adjustable measuring rate<br />
&#8211; Easy to use<br />
&#8211; Robust housing<br />
&#8211; Includes <strong>pH </strong>and <strong>conductivity </strong>electrode<br />
&#8211; Automatic calibration<br />
&#8211; Manual or automatic temperature compensation<br />
&#8211; BNC connector<br />
&#8211; Suitable for laboratory and on-site measurements<br />
&#8211; REDOX and oxygen electrode optionally available</p>
<table>
<tbody>
<tr>
<td valign="top" width="206"><strong>pH measurement</strong></td>
<td valign="top" width="366">&nbsp;</td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 14.0 pH</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 pH</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.02 pH + 2 digits</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">3 points (pH 4, pH 7, and pH 10)</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic with additional temperature sensor (0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF) or manual (0 &#8230; 100 ºC / 32 ºF &#8230; 212 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Redox measurement (optional)<br />
</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">1999 &#8230; 0 &#8230; 1999 mV</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 mV</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 0.5 % + 2 digits</td>
</tr>
<tr>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Conductivity</strong><strong> measurement</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 200 µS/cm, 0.2 &#8230; 2.0 mS/cm, 2 &#8230; 20.0 mS/cm, 20 &#8230; 200 mS/cm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±2 % of the measurement range + 1 digit</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">1413 mS/cm</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Total dissolved solids (TDS) </strong><br />
<strong>measurement</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 132 ppm, 132 &#8230; 1320 ppm, 1320 &#8230; 13200 ppm, 13200 &#8230; 132000 ppm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 ppm, 1 ppm, 10 ppm, 100 ppm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±2 % of the measurement range + 1 digit</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Salt content </strong><strong>measurement</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 12 % (of weight)</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 %</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.5 % of the measurement range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Oxygen</strong> <strong>measurement (optional)</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 20 mg/l (in water), 0 &#8230; 100 % (in air), 0 &#8230; 50 ºC / 32 ºF &#8230; 122 ºF</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 mg/l, 0.1 %, 0.1 ºC</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.4 mg/l, ±0.7 %, ±0.8 ºC</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">In the air</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 50 ºC / 32 ºF &#8230; 122 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Temperature</strong><strong> measurement</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 ºC</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.8 ºC</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">Automatic (0 &#8230; 60 ºC / 32 ºF &#8230; 140 ºF)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>General specifications</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement rate</td>
<td valign="top">1 second up to 8 hrs 59 mins 59 secs</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">LCD 52 x 38 mm / 2 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Memory</td>
<td valign="top">SD card up to 16 GB (2 GB card included)</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">RS-232</td>
</tr>
<tr>
<td valign="top">Software</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">6 x 1.5 V AA batteries (optional power adapter)</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; +50 ºC / &lt; 85 % RH</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">177 x 68 x 45 mm / 7.0 x 2.7 x 1.8&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">490 g / 1.1 lbs</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1/">Dissolved Oxygen Meter PCE-PHD 1</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/dissolved-oxygen-meter-pce-phd-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15723</post-id>	</item>
		<item>
		<title>Oxygen Meter PCE-DOM 20</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-20/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Mar 2021 07:05:01 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15719</guid>

					<description><![CDATA[<p><strong>PCE-DOM 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-20/">Oxygen Meter PCE-DOM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Oxygen Meter PCE-DOM Series<br />
Oxygen meter with exchangeable probes / Automatic temperature compensation / Oxygen saturation and the sample temperature / For mobile use</strong></div>
<div></div>
<div>The oxygen meter PCE-DOM 20 is a measuring device to determine the oxygen content both in liquids and in the ambient air. With this oxygen meter, water analyzes can be carried out on the oxygen content in a very short time and with the integrated temperature sensor, the oxygen meter is able to carry out an automatic temperature compensation. As a result, the oxygen meter is also used for analyzing the oxygen content of lakes or streams, as strong temperature fluctuations can occur here, which falsify the measurement result. This oxygen meter is also used, for example, in fish farming.</div>
<div></div>
<div>Before the initial start-up, the sensors on the oxygen measuring device are initially dry. In order to carry out a measurement, the sensors of the oxygen measuring device must be provided with the electrolyte supplied. Even if the membrane is damaged, it can be replaced with the oxygen measuring device in just a few steps. This ensures that the oxygen measuring device is ready for use again within a very short time.</div>
<div></div>
<div>&#8211; Measuring range up to 20 mg / L<br />
&#8211; For oxygen analysis<br />
&#8211; Temperature compensation up to 50°C / 122°F<br />
&#8211; Electrolyte included<br />
&#8211; For measurements in liquids and in air<br />
&#8211; Exchangeable oxygen sensor</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td width="178"><strong><span>Oxygen in liquids</span></strong></td>
<td width="225"></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 20 mg / L</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1 mg / L</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.4 mg / L</span></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong><span>Oxygen in the air </span><span>(reference measurement)</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 100%</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1%</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.7% </span></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong><span>Temperature</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1°C / 0.18°F</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.8°C / 1.4°F</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><span>Cable length</span></td>
<td><span>4 m / 13.1 ft</span></td>
</tr>
<tr>
<td><span>Temperature units</span></td>
<td><span>°C / °F</span></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>LCD display 29 x 28 mm / 1.1 x 1.1 in</span></td>
</tr>
<tr>
<td><span>Temperature compensation</span></td>
<td><span>Automatically</span></td>
</tr>
<tr>
<td><span>Storage</span></td>
<td><span>MIN, MAX</span></td>
</tr>
<tr>
<td><span>Automatic shutdown</span></td>
<td><span>After approx. 15 minutes</span></td>
</tr>
<tr>
<td><span>Operating conditions</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F, &lt; 80% RH</span></td>
</tr>
<tr>
<td><span>Power supply</span></td>
<td><span>4 x 1.5V AAA batteries</span></td>
</tr>
<tr>
<td><span>Power consumption</span></td>
<td><span>Approx. 6.2-mA</span></td>
</tr>
<tr>
<td><span>Dimensions</span></td>
<td><span>180 x 40 x 40 mm / 7.1 x 1.6 x 1.6 in(hand-held device without sensor)</span></td>
</tr>
<tr>
<td><span>Weight</span></td>
<td><span>Approx. 390 g / &lt; 1 lb</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-20/">Oxygen Meter PCE-DOM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15719</post-id>	</item>
		<item>
		<title>Oxygen Meter PCE-DOM 10</title>
		<link>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-10/</link>
					<comments>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Fri, 12 Mar 2021 07:02:08 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=15702</guid>

					<description><![CDATA[<p><strong>PCE-DOM 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-10/">Oxygen Meter PCE-DOM 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Oxygen meter PCE-DOM Series<br />
Oxygen meter with exchangeable probes / Automatic temperature compensation / Oxygen saturation and the sample temperature / For mobile use</strong></div>
<div></div>
<div>The oxygen meter PCE-DOM 10 is a measuring device to determine the oxygen content both in liquids and in the ambient air. With this oxygen meter, water analysis can be carried out on the oxygen content in a very short time and with an integrated temperature sensor, the oxygen meter is able to carry out an automatic temperature compensation. As a result, the oxygen meter is also used for analyzing the oxygen content of lakes or streams, as strong temperature fluctuations can occur here, which falsify the measurement result. This oxygen meter is also used, for example, in fish farming.</div>
<div></div>
<div>Before the initial start-up, the sensors on the oxygen meter are initially dry. In order to carry out a measurement, the sensors of the oxygen meter must be provided with the electrolyte supplied. Even if the membrane is possibly damaged, it can be replaced with the oxygen meter in just a few steps. This ensures that the oxygen meter is ready for use again within a very short time.</div>
<p>&#8211; Measuring range up to 20 mg / L<br />
&#8211; For oxygen analysis<br />
&#8211; Temperature compensation up to 50°C / 122°F<br />
&#8211; Electrolyte included<br />
&#8211; For measurements in liquids and in air<br />
&#8211; Exchangeable oxygen sensor</p>
<table>
<tbody>
<tr>
<td><strong><span>Oxygen in liquids</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 20 mg / L</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1 mg / L</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.4 mg / L</span></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong><span>Oxygen in the air </span><span>(reference measurement)</span></strong></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 100%</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1%</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.7% </span></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong><span>Temperature</span></strong></td>
<td></td>
</tr>
<tr>
<td><span>Measuring range</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F</span></td>
</tr>
<tr>
<td><span>Resolution</span></td>
<td><span>0.1°C / 0.18°F</span></td>
</tr>
<tr>
<td><span>Accuracy</span></td>
<td><span>± 0.8°C / 1.4°F</span></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><span>Temperature units</span></td>
<td><span>°C / °F</span></td>
</tr>
<tr>
<td><span>Display</span></td>
<td><span>LCD display 29 x 28 mm / 1.1 x 1.1 in</span></td>
</tr>
<tr>
<td><span>Temperature compensation</span></td>
<td><span>Automatically</span></td>
</tr>
<tr>
<td><span>Storage</span></td>
<td><span>MIN, MAX</span></td>
</tr>
<tr>
<td><span>Automatic shutdown</span></td>
<td><span>After approx. 15 minutes</span></td>
</tr>
<tr>
<td><span>Operating conditions</span></td>
<td><span>0 &#8230; 50°C / 32 &#8230; 122°F, &lt; 80% RH</span></td>
</tr>
<tr>
<td><span>Power supply</span></td>
<td><span>4 x 1.5V AAA batteries</span></td>
</tr>
<tr>
<td><span>Power consumption</span></td>
<td><span>Approx. 6.2-mA</span></td>
</tr>
<tr>
<td><span>Dimensions</span></td>
<td><span>180 x 40 x 40 mm / 7.1 x 1.6 x 1.6 in </span></td>
</tr>
<tr>
<td><span>Weight</span></td>
<td><span>Approx. 176 g / &lt; 1 lb</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-10/">Oxygen Meter PCE-DOM 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/oxygen-meter/oxygen-meter-pce-dom-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">15702</post-id>	</item>
	</channel>
</rss>