<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Redox Meter - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/redox-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/redox-meter/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Fri, 18 Nov 2022 06:11:29 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.15</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Redox Meter - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/redox-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Redox Meter PCE-BPH 20-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:57:31 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16676</guid>

					<description><![CDATA[<p><strong>PCE-BPH 20-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20-ica-incl-iso-calibration-certificate/">Redox Meter PCE-BPH 20-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Tabletop </strong><strong>redox meter with bluetooth interface / Data storage / Touchscreen /<br />
Measurement data can be exported to USB stick / pH, ORP, conductivity / Analysis software /<br />
With automatic and manual temperature compensation / incl. ISO Calibration Certificate</strong></div>
<p>The table-top redox meter can be used to quickly and precisely analyze liquid samples. This includes the measurement of pH, temperature, redox, conductivity, TDS, salinity and resistance. Thus, for example, water, alkalis, milk, wine and many other liquids can be checked for their quality with the table pH meter. The temperature probe is used for automatic temperature compensation when measuring a sample with the table pH meter. However, manual input of the temperature for temperature compensation is also possible with the table pH meter.</p>
<p>In addition to pH and temperature measurement, the table redox meter also has a conductivity measurement function. With the help of this function, in addition to the conductivity, the salt content of a liquid can also be determined. Because of the additional probe, the pH value as well as the conductivity can be determined and evaluated simultaneously.</p>
<p>Another special feature of the table-top redox meter is the multi-point calibration. This makes it possible to calibrate the table pH meter&#8217;s probes to several measuring points. This ensures that the measurement result is as precise as possible. Because of its high accuracy, the table-top pH meter is used, for example, for the analysis of samples in a laboratory. The table pH meter is also used in general educational institutions such as universities or vocational schools.</p>
<p>The tabletop redox meter is a measuring device with a large touchscreen and an easy-to-use user interface. With the electrode stand supplied with the pH meter table, all of the electrodes that can be connected can be positioned appropriately in the sample. This has the particular advantage that the operator can fully concentrate on the analysis of the measured values ​​and on the operation of the table pH meter, which prevents errors.</p>
<p>The table redox meter has several data interfaces. With the USB-A data interface, the measurement data stored by the table pH meter can be exported directly to any mass data storage device. The data is stored directly from the table pH meter in XML data format on the mass data storage device. The table pH meter can be connected directly to a PC via the USB-B data interface. The software supplied with the table pH meter enables a live view for further analysis of the measurement data. An optional printer can be connected via the Bluetooth interface on the table pH meter. It is therefore also possible to print out the current measured value directly from the table pH meter.</p>
<p>&#8211; Large 7&#8243; touchscreen<br />
&#8211; Bluetooth and USB interfaces<br />
&#8211; Exchangeable probes<br />
&#8211; pH, redox, conductivity<br />
&#8211; Direct connection to a PC<br />
&#8211; 3-point calibration<br />
&#8211; <strong>incl. ISO Calibration Certificate (only for pH value)</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td valign="top"><strong>Measuring range pH</strong></td>
<td valign="top">-2.000 &#8230; 19.999 pH</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 / 0.01 pH</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">electrode: ±0.02 pH</td>
</tr>
<tr>
<td valign="top">Input current</td>
<td valign="top">≤1×10^-12 A</td>
</tr>
<tr>
<td valign="top">Input resistance</td>
<td valign="top">≥3×10^12 Ω</td>
</tr>
<tr>
<td valign="top">Measurement stability</td>
<td valign="top">±0.01 pH/3h</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range mV</strong></td>
<td valign="top">-1999.9 &#8230; 1999.9 mV</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 mV</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.03 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range temperature</strong></td>
<td valign="top">-10 &#8230; 110 °C / 14 &#8230; 230 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 °C</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">5 &#8230; 60 °C (41 &#8230; 140 °F): ±0.4°C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">rest: ±0.8 °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range conductivity</strong></td>
<td valign="top">0 &#8230; 19.99 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">20.0 &#8230; 199.9 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">200 &#8230; 1999 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">2.00 &#8230; 19.99 mS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">20.0 &#8230; 1999.9 mS/cm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 / 0.1/ 1 μS/cm, 0.01 / 0.1 mS/cm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range TDS</strong></td>
<td valign="top">0 &#8230; 100 g/l</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.001 mg/l</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range salinity</strong></td>
<td valign="top">0 &#8230; 100 ppt</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 ppt</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range resistance</strong></td>
<td valign="top">0 &#8230; 100 MΩ cm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.001 / 0.01 / 0.1 / 1M Ω·cm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Data memory</td>
<td valign="top">300 pH measuring points</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">300 conductivity measuring points</td>
</tr>
<tr>
<td valign="top">Content of a memory point</td>
<td valign="top">date and time, measured value with unit and temperature</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">7&#8243; touchscreen</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1024 x 600 pixels</td>
</tr>
<tr>
<td valign="top">Interfaces</td>
<td valign="top">USB A</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">USB B</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Bluetooth</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">Primary: 230 &#8230; 240 V / 50 Hz</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Secondary: 12 V DC / 1 A</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">5 &#8230; 35 °C / 41 &#8230; 95 °F, &lt; 85 % RH not condensing</td>
</tr>
<tr>
<td valign="top">IP protection class</td>
<td valign="top">IP 54</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">175 × 220 × 40 mm / 68.9 x 86.6 x 15.7&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">ca. 310 g / 10.9 lb</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20-ica-incl-iso-calibration-certificate/">Redox Meter PCE-BPH 20-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16676</post-id>	</item>
		<item>
		<title>Redox Meter PCE-BPH 20</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:56:15 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16674</guid>

					<description><![CDATA[<p><strong>PCE-BPH 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20/">Redox Meter PCE-BPH 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Tabletop </strong><strong>redox meter with bluetooth interface / Data storage / Touchscreen /<br />
Measurement data can be exported to USB stick / pH, ORP, conductivity / Analysis software /<br />
With automatic and manual temperature compensation</strong></div>
<p>The table-top redox meter can be used to quickly and precisely analyze liquid samples. This includes the measurement of pH, temperature, redox, conductivity, TDS, salinity and resistance. Thus, for example, water, alkalis, milk, wine and many other liquids can be checked for their quality with the table pH meter. The temperature probe is used for automatic temperature compensation when measuring a sample with the table pH meter. However, manual input of the temperature for temperature compensation is also possible with the table pH meter.</p>
<p>In addition to pH and temperature measurement, the table redox meter also has a conductivity measurement function. With the help of this function, in addition to the conductivity, the salt content of a liquid can also be determined. Because of the additional probe, the pH value as well as the conductivity can be determined and evaluated simultaneously.</p>
<p>Another special feature of the table-top redox meter is the multi-point calibration. This makes it possible to calibrate the table pH meter&#8217;s probes to several measuring points. This ensures that the measurement result is as precise as possible. Because of its high accuracy, the table-top pH meter is used, for example, for the analysis of samples in a laboratory. The table pH meter is also used in general educational institutions such as universities or vocational schools.</p>
<p>The tabletop redox meter is a measuring device with a large touchscreen and an easy-to-use user interface. With the electrode stand supplied with the pH meter table, all of the electrodes that can be connected can be positioned appropriately in the sample. This has the particular advantage that the operator can fully concentrate on the analysis of the measured values ​​and on the operation of the table pH meter, which prevents errors.</p>
<p>The table redox meter has several data interfaces. With the USB-A data interface, the measurement data stored by the table pH meter can be exported directly to any mass data storage device. The data is stored directly from the table pH meter in XML data format on the mass data storage device. The table pH meter can be connected directly to a PC via the USB-B data interface. The software supplied with the table pH meter enables a live view for further analysis of the measurement data. An optional printer can be connected via the Bluetooth interface on the table pH meter. It is therefore also possible to print out the current measured value directly from the table pH meter.</p>
<p>&#8211; Large 7&#8243; touchscreen<br />
&#8211; Bluetooth and USB interfaces<br />
&#8211; Exchangeable probes<br />
&#8211; pH, redox, conductivity<br />
&#8211; Direct connection to a PC<br />
&#8211; 3-point calibration</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td valign="top"><strong>Measuring range pH</strong></td>
<td valign="top">-2.000 &#8230; 19.999 pH</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 / 0.01 pH</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">electrode: ±0.02 pH</td>
</tr>
<tr>
<td valign="top">Input current</td>
<td valign="top">≤1×10^-12 A</td>
</tr>
<tr>
<td valign="top">Input resistance</td>
<td valign="top">≥3×10^12 Ω</td>
</tr>
<tr>
<td valign="top">Measurement stability</td>
<td valign="top">±0.01 pH/3h</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range mV</strong></td>
<td valign="top">-1999.9 &#8230; 1999.9 mV</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 mV</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.03 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range temperature</strong></td>
<td valign="top">-10 &#8230; 110 °C / 14 &#8230; 230 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 °C</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">5 &#8230; 60 °C (41 &#8230; 140 °F): ±0.4°C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">rest: ±0.8 °C</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range conductivity</strong></td>
<td valign="top">0 &#8230; 19.99 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">20.0 &#8230; 199.9 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">200 &#8230; 1999 µS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">2.00 &#8230; 19.99 mS/cm</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">20.0 &#8230; 1999.9 mS/cm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 / 0.1/ 1 μS/cm, 0.01 / 0.1 mS/cm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range TDS</strong></td>
<td valign="top">0 &#8230; 100 g/l</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.001 mg/l</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range salinity</strong></td>
<td valign="top">0 &#8230; 100 ppt</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 ppt</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range resistance</strong></td>
<td valign="top">0 &#8230; 100 MΩ cm</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.001 / 0.01 / 0.1 / 1M Ω·cm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">measuring device: ±0.5 % of measuring range</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">in combination with measuring electrode: ±1.0 % of measuring range</td>
</tr>
<tr>
<td valign="top">Temperature compensation</td>
<td valign="top">0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td valign="top">Adjustable electrode constant</td>
<td valign="top">0.1 / 1 / 10 cm^-1</td>
</tr>
<tr>
<td valign="top">Adjustable reference temperature</td>
<td valign="top">25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Data memory</td>
<td valign="top">300 pH measuring points</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">300 conductivity measuring points</td>
</tr>
<tr>
<td valign="top">Content of a memory point</td>
<td valign="top">date and time, measured value with unit and temperature</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">7&#8243; touchscreen</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1024 x 600 pixels</td>
</tr>
<tr>
<td valign="top">Interfaces</td>
<td valign="top">USB A</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">USB B</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Bluetooth</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">Primary: 230 &#8230; 240 V / 50 Hz</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Secondary: 12 V DC / 1 A</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">5 &#8230; 35 °C / 41 &#8230; 95 °F, &lt; 85 % RH not condensing</td>
</tr>
<tr>
<td valign="top">IP protection class</td>
<td valign="top">IP 54</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">175 × 220 × 40 mm / 68.9 x 86.6 x 15.7&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">ca. 310 g / 10.9 lb</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20/">Redox Meter PCE-BPH 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16674</post-id>	</item>
		<item>
		<title>Redox Meter PCE-BPH 10-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:54:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16672</guid>

					<description><![CDATA[<p><strong>PCE-BPH 10-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10-ica-incl-iso-calibration-certificate/">Redox Meter PCE-BPH 10-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>redox meter with automatic temperature compensation / Data storage for 300 measured values ​​/</strong><br />
<strong>USB interfaces for mass data storage and PC connection / Large touchscreen /</strong><br />
<strong>Exchangeable probes / Stand for positioning the probes / Measuring range up to +19.999 pH / incl. ISO Calibration Certificate</strong></div>
<p>With the redox meter it is possible to carry out quick and precise analysis of the pH concentration of liquid samples. For example, with the pH meter it is possible to check alkaline solutions, water, wine, milk and many other liquids for the pH content. The table pH meter has a measuring range of -2 … +19.999 pH. With the temperature probe of the pH meter it is also possible to determine the temperature of the sample. This is particularly important as the pH measurement is highly temperature dependent. This means that both manual and automatic temperature compensation is possible with the pH meter.</p>
<p>The redox meter has a large 7&#8243; touchscreen and an easy-to-use user interface. With the supplied electrode stand, the pH electrode and the temperature sensor on the table pH meter can be positioned appropriately in the samples. This has the particular advantage that the user can now fully concentrate on analyzing the measured values ​​and operating the pH meter. This also prevents errors.</p>
<p>Another special feature of the redox meter is the multi-point calibration. This allows the pH meter to be calibrated to several reference points. This ensures that the measurement result is as accurate as possible. This is why the pH meter is also used in the analysis of samples in laboratories. The pH meter is also used in universities, vocational schools and other educational institutions. The multi-point calibration itself can be carried out with the optionally available pH buffer solutions.</p>
<p>The redox meter has a USB-A interface as a data interface. The measurement data stored on the pH meter can be transferred to any mass data storage device. The data from the pH meter are saved in XML data format. In addition to the USB-A interface for connecting mass data storage devices, there is also the USB-B connection for connecting the pH meter directly to a PC. The memory can now be read from the pH meter using the software. A live view via the software of the pH meter is also possible. A Bluetooth interface is also built into the pH meter. This allows the optional printer to be wirelessly connected to the pH meter.</p>
<p>&#8211; Measuring range between -2 &#8230; +19.999 pH<br />
&#8211; USB and Bluetooth interface<br />
&#8211; Live viewing software<br />
&#8211; Memory for 300 measured values<br />
&#8211; 3 point calibration<br />
&#8211; Automatic temperature compensation<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td><strong>Measuring range pH</strong></td>
<td><strong>-2.000 &#8230; +19.999 pH</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 / 0.01 pH</td>
</tr>
<tr>
<td>Accuracy</td>
<td>Electrode: ±0.02 pH</td>
</tr>
<tr>
<td>Input current</td>
<td>≤1×10-12 A</td>
</tr>
<tr>
<td>Input resistance</td>
<td>≥3×10+12 Ω</td>
</tr>
<tr>
<td>Measurement stability</td>
<td>±0.01 pH/3h</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring range mV</strong></td>
<td><strong>-1999.9 &#8230; +1999.9 mV</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>1 mV</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.03 % of measuring range</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring range temperature  </strong></td>
<td><strong>-10 &#8230; +110 °C / 14 &#8230; 230 °F<br />
</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 °C</td>
</tr>
<tr>
<td>Accuracy</td>
<td>5 &#8230; 60 °C (41 &#8230; 140 °F): ±0.4°C</td>
</tr>
<tr>
<td></td>
<td>Rest: ±0.8 °C</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td>Data memory</td>
<td>300 pH measuring points</td>
</tr>
<tr>
<td>Content of a memory point</td>
<td>date and time,</td>
</tr>
<tr>
<td></td>
<td>measured value with unit and temperature</td>
</tr>
<tr>
<td>Display</td>
<td>7&#8243; touchscreen</td>
</tr>
<tr>
<td>Resolution</td>
<td>1024 x 600 pixels</td>
</tr>
<tr>
<td>Interfaces</td>
<td>USB A, USB B, Bluetooth</td>
</tr>
<tr>
<td>Protection class</td>
<td>IP32</td>
</tr>
<tr>
<td>Power supply</td>
<td>Primary: 230 &#8230; 240 V / 50 Hz</td>
</tr>
<tr>
<td></td>
<td>Secondary: 12 V DC / 1 A</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>5 &#8230; 35 °C / 41 &#8230; 95 °F, &lt; 85 % r.h. not condensing</td>
</tr>
<tr>
<td>Dimensions</td>
<td>175 × 220 × 40 mm / 68.9 x 86.6 x 15.7&#8243;</td>
</tr>
<tr>
<td>Weight</td>
<td>ca. 310 g / 10.9 lb</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10-ica-incl-iso-calibration-certificate/">Redox Meter PCE-BPH 10-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16672</post-id>	</item>
		<item>
		<title>Redox Meter PCE-BPH 10</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:53:49 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16670</guid>

					<description><![CDATA[<p><strong>PCE-BPH 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10/">Redox Meter PCE-BPH 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Redox meter with automatic temperature compensation / Data storage for 300 measured values ​​/</strong><strong> USB interfaces for mass data storage and PC connection / Large touchscreen /</strong><br />
<strong>Exchangeable probes / Stand for positioning the probes / Measuring range up to +19.999 pH</strong></div>
<p>With the table-top redox meter it is possible to carry out quick and precise analysis of the pH concentration of liquid samples. For example, with the pH meter it is possible to check alkaline solutions, water, wine, milk and many other liquids for the pH content. The table pH meter has a measuring range of -2 … +19.999 pH. With the temperature probe of the pH meter it is also possible to determine the temperature of the sample. This is particularly important as the pH measurement is highly temperature dependent. This means that both manual and automatic temperature compensation is possible with the pH meter.</p>
<p>The redox meter has a large 7&#8243; touchscreen and an easy-to-use user interface. With the supplied electrode stand, the pH electrode and the temperature sensor on the table pH meter can be positioned appropriately in the samples. This has the particular advantage that the user can now fully concentrate on analyzing the measured values ​​and operating the pH meter. This also prevents errors.</p>
<p>Another special feature of the table-top redox meter is the multi-point calibration. This allows the pH meter to be calibrated to several reference points. This ensures that the measurement result is as accurate as possible. This is why the pH meter is also used in the analysis of samples in laboratories. The pH meter is also used in universities, vocational schools and other educational institutions. The multi-point calibration itself can be carried out with the optionally available pH buffer solutions.</p>
<p>The tabletop redox meter has a USB-A interface as a data interface. The measurement data stored on the pH meter can be transferred to any mass data storage device. The data from the pH meter are saved in XML data format. In addition to the USB-A interface for connecting mass data storage devices, there is also the USB-B connection for connecting the pH meter directly to a PC. The memory can now be read from the pH meter using the software. A live view via the software of the pH meter is also possible. A Bluetooth interface is also built into the pH meter. This allows the optional printer to be wirelessly connected to the pH meter.</p>
<p>&#8211; Measuring range between -2 &#8230; +19.999 pH<br />
&#8211; USB and Bluetooth interface<br />
&#8211; Live viewing software<br />
&#8211; Memory for 300 measured values<br />
&#8211; 3 point calibration<br />
&#8211; Automatic temperature compensation</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td><strong>Measuring range pH</strong></td>
<td><strong>-2.000 &#8230; +19.999 pH</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 / 0.01 pH</td>
</tr>
<tr>
<td>Accuracy</td>
<td>Electrode: ±0.02 pH</td>
</tr>
<tr>
<td>Input current</td>
<td>≤1×10-12 A</td>
</tr>
<tr>
<td>Input resistance</td>
<td>≥3×10+12 Ω</td>
</tr>
<tr>
<td>Measurement stability</td>
<td>±0.01 pH/3h</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>0 &#8230; 100 °C / 32 &#8230; 212 °F (automatic / manual)</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring range mV</strong></td>
<td><strong>-1999.9 &#8230; +1999.9 mV</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>1 mV</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.03 % of measuring range</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring range temperature  </strong></td>
<td><strong>-10 &#8230; +110 °C / 14 &#8230; 230 °F<br />
</strong></td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 °C</td>
</tr>
<tr>
<td>Accuracy</td>
<td>5 &#8230; 60 °C (41 &#8230; 140 °F): ±0.4°C</td>
</tr>
<tr>
<td></td>
<td>Rest: ±0.8 °C</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td>Data memory</td>
<td>300 pH measuring points</td>
</tr>
<tr>
<td>Content of a memory point</td>
<td>date and time,</td>
</tr>
<tr>
<td></td>
<td>measured value with unit and temperature</td>
</tr>
<tr>
<td>Display</td>
<td>7&#8243; touchscreen</td>
</tr>
<tr>
<td>Resolution</td>
<td>1024 x 600 pixels</td>
</tr>
<tr>
<td>Interfaces</td>
<td>USB A, USB B, Bluetooth</td>
</tr>
<tr>
<td>Protection class</td>
<td>IP32</td>
</tr>
<tr>
<td>Power supply</td>
<td>Primary: 230 &#8230; 240 V / 50 Hz</td>
</tr>
<tr>
<td></td>
<td>Secondary: 12 V DC / 1 A</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>5 &#8230; 35 °C / 41 &#8230; 95 °F, &lt; 85 % r.h. not condensing</td>
</tr>
<tr>
<td>Dimensions</td>
<td>175 × 220 × 40 mm / 68.9 x 86.6 x 15.7&#8243;</td>
</tr>
<tr>
<td>Weight</td>
<td>ca. 310 g / 10.9 lb</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10/">Redox Meter PCE-BPH 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-bph-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16670</post-id>	</item>
		<item>
		<title>Redox Meter PCE-PHD 1-R</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-phd-1-r-2/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-phd-1-r-2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:50:29 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16668</guid>

					<description><![CDATA[<p><strong>PCE-PHD 1-R</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-phd-1-r-2/">Redox Meter PCE-PHD 1-R</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div><strong>PCE-PHD 1-R Redox Meter </strong></div>
<div><strong>SD card memory (1 &#8230; 16 GB), stored data is stored as an Excel file / large, easy-to-read display / RS-232 interface and optional software for direct transfer to the PC / Includes a redox electrode</strong></div>
</div>
<div>
<p align="justify">PCE-PHD 1-R Multifunction Conductivity Meter is a portable, easy-to-use measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the Multifunction Conductivity Meter is used for laboratory and <em>in situ</em> testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water.</p>
<p>&nbsp;</p>
<p align="justify">Temperature compensation guarantee a high level of accuracy even with variable temperature measurements. PCE-PHD 1-R is supplied with a redox electrode. Additional electrodes are available for purchase separately, as is an optional mains adapter for power and a software kit with an RS-232 cable. PCE-PHD 1-LF acts as a real-time data logger. All values can be stored directly on the included SD card in Microsoft Excel format or transferred to a PC by means of the RS-232 port. Thus, no additional software is required for evaluation of the data.</p>
</div>
<p>&nbsp;</p>
<div>
<div>&#8211; Real-time data logger<br />
&#8211; Compatibility with SD cards up to 16 GB<br />
&#8211; The stored data is saved directly as an Excel file on the SD card (no software needed for evaluation)<br />
&#8211; RS-232 interface for online data transmission<br />
&#8211; High precision<br />
&#8211; Low battery indication<br />
&#8211; Large LC display<br />
&#8211; Adjustable measuring rate<br />
&#8211; Easy to use<br />
&#8211; Robust housing<br />
&#8211; Automatic calibration<br />
&#8211; Manual or automatic temperature compensation<br />
&#8211; BNC connector<br />
&#8211; Suitable for laboratory and on-site measurement<br />
&#8211; Electrode for <strong>redox </strong>included<strong><br />
</strong></div>
</div>
<div></div>
<div></div>
<div>
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in active">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong>Redox</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">1999 &#8230; 0 &#8230; 1999 mV</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 mV</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">±0.5 % of the measurement range + 2 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>General specifications</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measurement rate</td>
<td valign="top">1 second up to 8 hrs 59 mins 59 secs</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">LCD 52 x 38 mm / 2 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Memory</td>
<td valign="top">SD card up to 16 GB (2 GB card included)</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">RS-232</td>
</tr>
<tr>
<td valign="top">Software</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">6 x 1.5 V AA batteries (optional power adapter)</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; +50 ºC / &lt; 85 % RH</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">177 x 68 x 45 mm / 7.0 x 2.7 x 1.8&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">490 g / 1.1 lbs</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-phd-1-r-2/">Redox Meter PCE-PHD 1-R</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-phd-1-r-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16668</post-id>	</item>
		<item>
		<title>Redox-Meter PCE-228-R</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-228-r/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-228-r/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:49:00 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16666</guid>

					<description><![CDATA[<p><strong>PCE-228-R</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-228-r/">Redox-Meter PCE-228-R</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div><strong>PCE-228-R Redox meter / Portable Redox Meter, for both pH and temperature values / RS-232 interface and optional software </strong></div>
<p>&nbsp;</p>
<div>PCE-288-R Redox Meter is a very easy to use meter to measure mV / pH / ºC. In the PC-228-R Redox Meter values can be directly stored in the SD memory card (Excel format) or can be directly transferred in real time to a PC or laptop by means of the RS-232 interface. Both Redox value and temperature can be directly transferred to a PC by means of the RS-232 interface, so we offer you software and a RS-232 data cable as additional components. Temperature compensation (function available only for measurements of pH) can be made by hand or automatically by means of a temperature sensor included in the delivery of the Redox Meter. So, all the previously mentioned characteristics provide this Redox Meter with a high reliability. The PCE-228-R Redox Meter has a three-point calibration. Redox, temperature and pH values can be determined by means of the combined meter. <strong>To determine the pH value an additional pH electrode must be purchased. You can find the pH electrode in the accessories tab.</strong> We recommend you use the PW 03 electrode. PCE-228-R Redox Meter is powered by batteries (one 9V battery is included in the delivery).</div>
<p>&nbsp;</p>
<div>
<div>&#8211; Good quality at an affordable price<br />
&#8211; SD memory card (1 &#8230; 16 GB)<br />
&#8211; Values are directly stored in Excel format in the SD memory card (any additional software is required)<br />
&#8211; RS-232 interface for real time data transference<br />
&#8211; Measures Redox and temperature<br />
&#8211; High accuracy<br />
&#8211; Low battery indication<br />
&#8211; Large LCD display<br />
&#8211; Adjustment of the measurement rate<br />
&#8211; Easy-to-use<br />
&#8211; Compact case<br />
&#8211; Redox OPR-14 sensor and stainless steel temperature sensor are included<br />
&#8211; Automatic calibration<br />
&#8211; Automatic / manual temperature compensation (only for pH measurements not for Redox ones)<br />
&#8211; BNC connection<br />
&#8211; Suitable for laboratories or on-the spot Redox measurements.<br />
&#8211; Additional Redox electrode</div>
</div>
<div></div>
<div></div>
<div>
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in active">
<div class="usertext">
<table>
<tbody>
<tr>
<td>Measurement ranges</td>
<td>1999 &#8230; 0 &#8230; 1999 mV</td>
</tr>
<tr>
<td>0.00 &#8230; 14.00 pH<br />
(only with optional pH electrode)</td>
</tr>
<tr>
<td>0.0 &#8230; 65.0°C (only temperature sensor)</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 mV</td>
</tr>
<tr>
<td>0.01 pH</td>
</tr>
<tr>
<td>0.1°C</td>
</tr>
<tr>
<td>Accuracy (a 20°C)</td>
<td>± (0.5% + 2 digits)</td>
</tr>
<tr>
<td>± (0.02 pH + 2 digits)</td>
</tr>
<tr>
<td>± 0.5°C</td>
</tr>
<tr>
<td>Calibration</td>
<td>Automatic three-point calibration</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>Automatic form 0 &#8230; 65°C or by hand between 0 &#8230; 100°C by removing temperature sensor.<br />
(only for pH measuremnts)</td>
</tr>
<tr>
<td>Electrode</td>
<td>Redox OPR-14 electrode,<br />
1 meter cable and BNC plug</td>
</tr>
<tr>
<td>Measurement rate</td>
<td>Adjustable from 1 second up to<br />
8 hours 59 min 59 seg</td>
</tr>
<tr>
<td>Memory</td>
<td>SD card from 1 &#8230; 16 GB<br />
(2 GB card included)</td>
</tr>
<tr>
<td>Display</td>
<td>LCD: 52 x 38 mm / 2 x 1.5 in</td>
</tr>
<tr>
<td>Interface</td>
<td>RS 232</td>
</tr>
<tr>
<td>Software</td>
<td>Optional component</td>
</tr>
<tr>
<td>Power supply</td>
<td>6 x 1.5V AA battery /<br />
9V adaptor (optional)</td>
</tr>
<tr>
<td>Environmental conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F max. 80% H.r.</td>
</tr>
<tr>
<td>Dimensions</td>
<td>177 x 68 x 45 mm / 7 x 2.7 x 1.8 in</td>
</tr>
<tr>
<td>Weight</td>
<td>490 g / 1.1 lbs</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-228-r/">Redox-Meter PCE-228-R</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-228-r/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16666</post-id>	</item>
		<item>
		<title>Redox Meter PCE-ORP 3</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-orp-3/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-orp-3/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:47:40 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16664</guid>

					<description><![CDATA[<p><strong>PCE-ORP 3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-orp-3/">Redox Meter PCE-ORP 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Redox meter PCE-ORP 3</strong></div>
<div><strong> </strong></div>
<div><strong>ORP measuring device for measuring temperature and redox potential / Measurement data memory for 50 data sets / Water- and dust-proof housing / Exchangeable measuring electrode</strong></div>
<div>The ORP measuring device is used to determine the redox potential in laboratories, industry and environmental protection. In addition to the classic use in laboratories, the ORP measuring instrument is used in the industrial sector, such as food production. The ORP meter has been designed to be a handy meter powered by batteries. Thus, a mobile use is enabled and facilitated by a belt clip.</div>
<div></div>
<div>Chemically, the redox potential describes the oxidation and reduction potential of a solution. In the industry, the ORP meter is used in addition to food production also in the detoxification of wastewater. This is done by reducing chromate or the oxidation of cyanide.</div>
<div></div>
<div>The ORP meter is a durable instrument that allows you to replace the electrode after a long period of use. The measured values ​​are shown on the display or can also be stored on the internal measured value memory. This measured value memory has a capacity of 50 measured values, whereby the measured values ​​are provided with a time and date stamp. Thus, they are traceable and a corresponding analysis is facilitated in favor of the user.</div>
<p>&#8211; Robust housing (IP67)<br />
&#8211; Measurement data memory for 50 data sets<br />
&#8211; Mobile measuring instrument<br />
&#8211; HOLD function<br />
&#8211; Exchangeable electrode<br />
&#8211; Low battery warning</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in active">
<div class="usertext">
<div class="usertext">
<table>
<tbody>
<tr>
<td>Absolute measuring range redox potential</td>
<td>-1100 &#8230; +1100 mV</td>
</tr>
<tr>
<td>Resolution redox potential</td>
<td>1 mV</td>
</tr>
<tr>
<td>Measuring accuracy redox potential</td>
<td>± 1 mV ± 1 digit</td>
</tr>
<tr>
<td>Relative calibration range Redox potential</td>
<td>-999 &#8230; +999 mV, adjustable</td>
</tr>
<tr>
<td>Input resistance</td>
<td>&gt; 1012 Ω</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Technical data of ORP meter PCE-ORP 3: Temperature</strong></td>
</tr>
<tr>
<td>Measuring range temperature</td>
<td>-10 &#8230; 100°C / 14 &#8230; 212°F</td>
</tr>
<tr>
<td>Resolution temperature</td>
<td>1 mV</td>
</tr>
<tr>
<td>Measuring accuracy temperature</td>
<td>± 0.3°C / 0.5°F</td>
</tr>
<tr>
<td>Temperature sensor</td>
<td>Thermistor, 10K at 25°C / 77°F</td>
</tr>
<tr>
<td>Measuring unit</td>
<td>° C, ° F</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Technical Data of ORP Meter PCE-ORP 3: General</strong></td>
</tr>
<tr>
<td>power supply</td>
<td>4 x LR44 battery</td>
</tr>
<tr>
<td>Battery life</td>
<td>About 200 hours</td>
</tr>
<tr>
<td>Environmental conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td>display</td>
<td>Graphic LCD, 98 x 64 pixels</td>
</tr>
<tr>
<td>Measurement data storage</td>
<td>50 measuring groups with date and time stamp</td>
</tr>
<tr>
<td>Automatic shutdown</td>
<td>After 10 minutes of inactivity</td>
</tr>
<tr>
<td>Casing</td>
<td>Waterproof housing (IP67)</td>
</tr>
<tr>
<td>Dimensions (L x W x H)</td>
<td>193 x 44 x 25 mm / 7.6 x 1.7 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>107 g / &lt; 1 lb</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-orp-3/">Redox Meter PCE-ORP 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-orp-3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16664</post-id>	</item>
		<item>
		<title>Redox Meter PCE-PH 30</title>
		<link>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-ph-30/</link>
					<comments>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-ph-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 25 Mar 2021 09:43:04 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=16656</guid>

					<description><![CDATA[<p><strong>PCE-PH 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-ph-30/">Redox Meter PCE-PH 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Redox meter</strong><strong> PCE-PH 30<br />
pH, conductivity, redox tester with interchangeable sensors /  Easy-to-read LC display / Pen pH meter / Automatic temperature compensation</strong></div>
<div>The pH tester PCE-PH 30 is the optimal tool for checking the most important water parameters. The portable pH tester is used to control pH and conductivity. It also serves for simultaneous temperature measurement. Furthermore, the pH tester can be used to measure the redox potential.</div>
<div></div>
<div>A three-point calibration and automatic temperature compensation up to 90°C / 194°F guarantee high accuracy even with fluctuating measuring temperatures. The pH tester has a readable display. The test device is supplied with pH and temperature probe, calibration and storage fluid. The redox probe is available separately as an accessory.</div>
<p>&#8211; 6 in 1 pH tester<br />
&#8211; IP57 housing<br />
&#8211; Automatic temperature compensation<br />
&#8211; Battery operation<br />
&#8211; 3 point pH calibration<br />
&#8211; Exchangeable electrodes<br />
&#8211; Max-Min Hold function<br />
&#8211; Automatic electrode detection</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in active">
<div class="usertext">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>pH</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">-2 &#8230; 16 pH</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 pH</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 0,01pH + 1Dgt</td>
</tr>
<tr>
<td valign="top">ATC</td>
<td valign="top">0 &#8230; 90°C / 32 &#8230; 194°F</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">pH 4, 7, 10</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Redox</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">± 1000 mV</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 mV</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 2 mV + 1 Dgt</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Conductivity</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 2000 μS, 2 &#8230; 20 mS</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 μS, 0.01 mS</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 2% of measuring range</td>
</tr>
<tr>
<td valign="top">ATC</td>
<td valign="top">0 &#8230; 50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">0 μS, 1413 μS, 12.88 mS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>TDS</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 1300 ppm, 1.3 &#8230; 13 ppt</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 ppm, 0.01 ppt</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 2% of measuring range</td>
</tr>
<tr>
<td valign="top">ATC</td>
<td valign="top">0 &#8230; 50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Salinity</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 1000 ppm, 1 &#8230; 12 ppt</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">1 ppm, 0.01 ppt</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 2% of measuring range</td>
</tr>
<tr>
<td valign="top">ATC</td>
<td valign="top">0 &#8230; 50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring function</td>
<td valign="top"><strong>Temperature</strong></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 90°C / 32 &#8230; 194°F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1°C / 0.18°F</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 0.2°C / 0.36°F + 1 Dgt</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">LCD display</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">4 x 1.5V AAA battery</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">195 x 40 x 36 mm / 7.7 x 1.6 x 1.4 in</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">About 135 g / &lt; 1 lb</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/redox-meter/redox-meter-pce-ph-30/">Redox Meter PCE-PH 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/redox-meter/redox-meter-pce-ph-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16656</post-id>	</item>
	</channel>
</rss>