<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Surface Testing - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/surface-testing/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/surface-testing/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Fri, 18 Nov 2022 04:57:23 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Surface Testing - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/surface-testing/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Surface Testing &#8211; Temperature Meter PCE-IR10 incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-temperature-meter-pce-ir10-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-temperature-meter-pce-ir10-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 03:07:37 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17929</guid>

					<description><![CDATA[<p><strong>PCE-IR10-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-temperature-meter-pce-ir10-incl-iso-calibration-certificate/">Surface Testing &#8211; Temperature Meter PCE-IR10 incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Surface testing &#8211; temperature meter</strong><strong> with LCD for continuous measurement of surface temperature of all solid materials, designed for fixed installation</strong></div>
<div>
<div>
<p>The PCE-IR10 surface testing &#8211; temperature meter is made up of a small sensor head and a separate electrical component. The surface testing &#8211; temperature meter sensor is so small that it can fit in almost any space. part from this, the device offers similar specifications as other devices. The electrical component of the PCE-IR10 facilitates the use of functions hat are not normally found in a device of this quality. Among these are adjustable emissivity, minimum, maximum and average value, as well as software to program the device via a computer or directly from the unit&#8217;s LCD. Due to its small size, this temperature tester is ideal for different systems in a production line. The device is accurate, easy to install and economical.</p>
<p>Measuring temperature with the PCE-IR10 non-contact temperature tester is an economical alternative to similar contact devices (additional information about the functioning principle of measuring temperature with surface testing &#8211; temperature meters). Also, look at this brief text about the practice of measuring temperature with infrared devices.</p>
</div>
<div>
<p>To get the highest precision from this device, the user can adjust the emissivity, which is different for each type of surface material being measured. If the user measures a material which is not in the table, they can establish the emissivity value and adjust the temperature measured by the temperature reader.</p>
</div>
</div>
<div>&#8211; High temperature range of up to 600°C / 1112°F</div>
<div>&#8211; Small sensor head for use in tight spaces</div>
<div>&#8211; Analogue output</div>
<div>&#8211; USB/ RS-232 / RS-485 / relay outputs</div>
<div>&#8211; Operating temperature up to 180°C / 356°F (sensor head); 65°C / 149°F (device)</div>
<div>&#8211; adjustable emissivity, minimum / maximum Hold, average value</div>
<div>&#8211; LCD</div>
<div>&#8211; Can funstion in a network of up to 32 sensors connected by optional RS-485</div>
<div>&#8211; Power of 8 &#8230; 36V DC</div>
<p>&#8211; <strong>I</strong><strong>ncl. ISO Calibration Certificate</strong></p>
<p><strong><span style="color: #ff0000">***ATTENTION***</span> Our temperature sensors are designed for industrial and laboratory surface temperature measurement ONLY. They are not designed or certified for body temperature measurement or for medical use.</strong></p>
<table>
<tbody>
<tr>
<td><strong>Electronic parameters</strong></td>
<td></td>
</tr>
<tr>
<td valign="top">Outputs</td>
<td>Analogue: 4 &#8230; 20-mA, 0 &#8230; 20-mA,<br />
0 &#8230; 5V (adjustable), Type-J or K sensors<br />
Temperature sensor head 10 mV / °C or °F alarm<br />
Relay (via software) optional digital outputs USB,<br />
RS-232, RS-485, relay</td>
</tr>
<tr>
<td>Inputs</td>
<td>Emissivity, temperature compensation, trigger (by software)</td>
</tr>
<tr>
<td>Cable length</td>
<td>1 m / 3.3 ft, other lengths can be ordered separately</td>
</tr>
<tr>
<td>Consumption</td>
<td>Max. 100-mA</td>
</tr>
<tr>
<td>Power</td>
<td>8 &#8230; 36V DC</td>
</tr>
<tr>
<td><strong>General parameters</strong></td>
<td></td>
</tr>
<tr>
<td>Ingress protection</td>
<td>IP65 (NEMA-4)</td>
</tr>
<tr>
<td>Operating temperature<br />
for Sensor head</td>
<td>-20 &#8230; 180°C / -4 &#8230; 356°F</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-40 &#8230; 85°C / -40 &#8230; 185°F</td>
</tr>
<tr>
<td>Operating relative humidity</td>
<td>10 &#8230; 95% without condensation</td>
</tr>
<tr>
<td>EMI</td>
<td>IEC 801-3, level 3 (maximum cable length of 3m)</td>
</tr>
<tr>
<td>Weight</td>
<td></td>
</tr>
<tr>
<td>Sensor head</td>
<td>40 g / .09 lb</td>
</tr>
<tr>
<td>Electronic component</td>
<td>420 g / &lt; 1 lb</td>
</tr>
<tr>
<td><strong>Technical parameters</strong></td>
<td></td>
</tr>
<tr>
<td>Temperature range</td>
<td>40 &#8230; 600°C / 104 &#8230; 1112°F</td>
</tr>
<tr>
<td>Spectral range</td>
<td>8.0 &#8230; 14 µm</td>
</tr>
<tr>
<td>Optical resolution <sup>1</sup></td>
<td>15:1</td>
</tr>
<tr>
<td>Accuracy <sup>2</sup></td>
<td>± 1% or ± 1°C<sup>3 </sup>/ 1.8°F<sup>3</sup></td>
</tr>
<tr>
<td>Repeatablility</td>
<td>± 0.5% or ± 0.5°C<sup>3 </sup>/ 0.9°F<sup>3</sup></td>
</tr>
<tr>
<td>Temperature coefficient</td>
<td>± 0.05°C / 0.09°F, °C / °F or ± 0.05% / °C<sup>3 </sup>°F<sup>3</sup></td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.1°C<sup>5</sup><sup> </sup>/ 1.8°F<sup>5</sup></td>
</tr>
<tr>
<td>Response time</td>
<td>150 ms (95%)</td>
</tr>
<tr>
<td>Emissivity</td>
<td>0.100 &#8211; 1.000 adjustable in digital mode, by units of 0.001</td>
</tr>
<tr>
<td>Functions</td>
<td>Maximum, minimum Hold and average value</td>
</tr>
<tr>
<td></td>
<td><sup>1</sup> 90% of energy<br />
<sup>2</sup> at an operating temperature of 23°C / 73°F, ± 5°C / 9°F<br />
<sup>3</sup> shighest value is considered correct<br />
<sup>4</sup> ISO calibration certificate based on the NIST / DKD measurement<br />
<sup>5</sup> for a temperature margin of 300K</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-temperature-meter-pce-ir10-incl-iso-calibration-certificate/">Surface Testing &#8211; Temperature Meter PCE-IR10 incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-temperature-meter-pce-ir10-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17929</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Coating Thickness Gauge PCE-USC 30</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-coating-thickness-gauge-pce-usc-30/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-coating-thickness-gauge-pce-usc-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 03:04:36 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17925</guid>

					<description><![CDATA[<p><strong>PCE-USC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-coating-thickness-gauge-pce-usc-30/">Surface Testing &#8211; Coating Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>PCE-USC 30 is a coating thickness gauge designed for the non-destructive testing (NDT) and non-destructive evaluation (NDE) of electrically conductive materials. This portable, handheld thickness meter detects surface defects and measures layer thicknesses using an eddy current. The PCE-USC 30 material tester also measures metal conductivity in accordance with the International Annealed Copper Standard (IACS).</div>
<div></div>
<div>The PCE-USC 30 thickness gauge has myriad applications including weld seam testing, crack detection, metallurgical and material sorting tests, quality assurance and control, aviation component testing of turbine blades, and pipeline and container testing in the chemical, oil and gas industries.</div>
<div></div>
<div>&#8211; Frequency range: 0.01 &#8230; 16000 kHz<br />
&#8211; Visually depicts surface defects on screen<br />
&#8211; 4.3&#8243; full-color display (TFT)<br />
&#8211; Ergonomic design<br />
&#8211; Long battery life</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="283">Frequency range</td>
<td valign="top" width="303">0.01 &#8230; 16000 kHz</td>
</tr>
<tr>
<td valign="top">Probe voltage supply</td>
<td valign="top">0, 5, 1, 2, 4, 6 V</td>
</tr>
<tr>
<td valign="top">Signal phase shift</td>
<td valign="top">0 &#8230; 360 °</td>
</tr>
<tr>
<td valign="top">Sampling frequency</td>
<td valign="top">0 &#8230; 10 kHz</td>
</tr>
<tr>
<td valign="top">Duration of signal superimposition</td>
<td valign="top">0 / 0.5 / 1/2/3/4 seconds</td>
</tr>
<tr>
<td valign="top">Alarm</td>
<td valign="top">Circular, horizontal line, circle sector, cut off</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">Full-color display (TFT)</td>
</tr>
<tr>
<td valign="top">Display size</td>
<td valign="top">4.3 &#8220;(diagonal)</td>
</tr>
<tr>
<td valign="top">Display resolution</td>
<td valign="top">800 x 480 pixels</td>
</tr>
<tr>
<td valign="top">Amplification adjustment</td>
<td valign="top">0 &#8230; 100 dB</td>
</tr>
<tr>
<td valign="top">Filters</td>
<td valign="top">Low-pass (1 &#8230; 4000 Hz), high-pass (1 &#8230; 4000 Hz), band, differential, average</td>
</tr>
<tr>
<td valign="top">Average interval between measurement errors</td>
<td valign="top">4000 hours</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">12 V battery</td>
</tr>
<tr>
<td valign="top">Battery capacity</td>
<td valign="top">4500 mAh</td>
</tr>
<tr>
<td valign="top">Continuous runtime per battery charge</td>
<td valign="top">Approx. 8 hours</td>
</tr>
<tr>
<td valign="top">Operating temperature</td>
<td valign="top">-20 &#8230; +45 ° C</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">Approx. 0.9 kg</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">230 x 135 x 98 mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-coating-thickness-gauge-pce-usc-30/">Surface Testing &#8211; Coating Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-coating-thickness-gauge-pce-usc-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17925</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Colorimeter PCE-CSM 10</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-10/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 03:00:28 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17923</guid>

					<description><![CDATA[<p><strong>PCE-CSM 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-10/">Surface Testing &#8211; Colorimeter PCE-CSM 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>Colorimeter PCE-CSM 10 for quality control / PC software included / Li-ion battery / different color spaces / black and white calibration / determination of reference values and samples / white calibration / 3.5&#8243; touch screen</strong></div>
<div></div>
</div>
<div>
<div>The colorimeter PCE-CSM 10 was developed for quality control, offers a high accuracy and comes with a 3.5&#8243; touch screen display. When using the colorimeter, you can choose between different color spaces (CIE L*A*B, XYZ, Yxy, LCh, CIE LUV, HunterLAB). After a measurement with the colorimeter, the reading can be used as a reference value while other readings can be recorded as a sample and later be compared to the reference value easily.</div>
<div></div>
<div>In addition to the individual colour space coordinates, the deviation between the reading is also displayed. When using the colorimeter, it is possible to store up to 1000 reference values and up to 15000 samples on the device. The measured data can also be transferred to a PC via the USB interface. A special PC software is included in the package.</div>
<div></div>
</div>
<div>
<div>&#8211; CIE L*A*B, XYZ, Yxy, LCh, CIE LUV, HunterLAB<br />
&#8211; black and white calibration<br />
&#8211; determination of reference values and samples<br />
&#8211; 3.5&#8243; touch screen display</div>
<div>&#8211; rechargeable lithium-ion battery<br />
&#8211; high accuracy<br />
&#8211; easy to use<br />
&#8211; incl. PC software<br />
&#8211; 8 mm aperture</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td>Measuring geometry</td>
<td>8°/d</td>
</tr>
<tr>
<td>Measuring aperture</td>
<td>Diameter 8 mm</td>
</tr>
<tr>
<td>Integrating sphere</td>
<td>Diameter 58 mm</td>
</tr>
<tr>
<td>Sensor</td>
<td>Silicon photoelectric diode</td>
</tr>
<tr>
<td>Wavelength range</td>
<td>400 &#8230; 700 nm</td>
</tr>
<tr>
<td>Reflection factor range</td>
<td>0 &#8230; 200 %</td>
</tr>
<tr>
<td>Colour spaces</td>
<td>CIE L*A*B, XYZ, Yxy, LCh, CIE LUV, HunterLAB</td>
</tr>
<tr>
<td>Colour index</td>
<td>ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*cmc(l:c), CIE2000, ΔE*00, ΔE(h)</td>
</tr>
<tr>
<td>Chromacity data</td>
<td>WI (ASTM E313, CIE/ISO, AATCC, Hunter)<br />
YI (ASTM D1925, ASTM E313)<br />
TI (ASTM E313, CIE/ISO)<br />
Metamerism Index Mt<br />
color stain, color fastness</td>
</tr>
<tr>
<td>Observation angle</td>
<td>2° / 10°</td>
</tr>
<tr>
<td>Measuring time</td>
<td>1.2 seconds</td>
</tr>
<tr>
<td>Light source</td>
<td>D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30)</td>
</tr>
<tr>
<td>Light source device</td>
<td>combined LED</td>
</tr>
<tr>
<td valign="top" width="50%">Repeatability</td>
<td valign="top" width="50%">Standard deviation within ΔE*ab 0.04<br />
Average of 30 measurements of standard white plate</td>
</tr>
<tr>
<td valign="top" width="50%">Error between equipment</td>
<td valign="top" width="50%">ΔE*ab 0.2</td>
</tr>
<tr>
<td>Display functions</td>
<td>Spectral value/graph, colorimetric value, colour difference (value/graph), PASS/FAIL result, colour offset, colour simulation, colour index settings (ΔE*94, ΔE*cmc, ΔE*2000), error limit settings, time settings, language settings, restore factory settings</td>
</tr>
<tr>
<td>Display</td>
<td>3.5&#8243; TFT touch screen</td>
</tr>
<tr>
<td>Interface</td>
<td>USB / RS-232</td>
</tr>
<tr>
<td>Storage</td>
<td>1,000 reference values, 15,000 samples</td>
</tr>
<tr>
<td>Power supply</td>
<td>Rechargeable lithium-ion battery<br />
3.7 V at 3,200 mAh</td>
</tr>
<tr>
<td>Life of light source</td>
<td>5 years, &gt; 1.6 million measurements</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; +40 °C</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Dimensions</td>
<td>90 x 77 x 230 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>600 g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-10/">Surface Testing &#8211; Colorimeter PCE-CSM 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17923</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Conductivity Tester for Metals PCE-COM 20-ICA incl. ISO Cal.</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-tester-for-metals-pce-com-20-ica-incl-iso-cal/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-tester-for-metals-pce-com-20-ica-incl-iso-cal/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 02:57:51 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17919</guid>

					<description><![CDATA[<p><strong>PCE-COM 20-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-tester-for-metals-pce-com-20-ica-incl-iso-cal/">Surface Testing &#8211; Conductivity Tester for Metals PCE-COM 20-ICA incl. ISO Cal.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p style="text-align: center"><strong>PCE-COM 20-ICA Surface Testing &#8211; Conductivity Tester for Non-Ferrous Metals incl. ISO Calibration Certificate<br />
Large measuring range up to 112% IACS or 65 MS/m with lift-off and temperature compensation, memory, PC-compatible software, 60 kHz operating frequency</strong></p>
</div>
<div>
<p>PCE-COM 20 is a portable handheld non-destructive material tester for non-ferrous metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper.</p>
<p>Featuring an operating frequency of 60 kHz, the conductivity meter has a large measuring range of 0.51 &#8230; 112% IACS with an accuracy of +/- 0.5% at 20°C / 68°F. Thanks to a resolution of up to 0.01% IACS, automatic temperature compensation (ATC) and lift-off compensation (up to 500 μm), the device ensures quick, easy, accurate and reproducible measurements of coated or corroded pieces during changing ambient conditions.</p>
<p>Measurement of the electrical conductivity of non-ferrous metals, such as aluminum, copper, titanium, magnesium or bronze, is necessary in applications involving electrical conductors and the characterization of alloys. Typical application areas are the assessment of strength differences in heat-treated or hardened materials, the authenticity testing of coin alloys, the verification of alloy inhomogeneities in critical components and the sorting of materials.</p>
<p>The conductivity meter is powered by an internal battery that can be charged via the interface on the bottom of the unit. In addition to the connection for the charging adapter, there is a USB interface allowing for the transfer of measurement data to a PC for more detailed analysis.</p>
</div>
<p>&#8211; Eddy current measuring principle<br />
&#8211; For non-ferrous metals and alloys<br />
&#8211; Non-destructive testing (NDT)<br />
&#8211; 60 kHZ operating frequency<br />
&#8211; Large measuring range up to 112% IACS or 65 MS/m<br />
&#8211; Memory for up to 500 groups of measurements<br />
&#8211; Automatic temperature compensation (ATC)<br />
&#8211; Lift-off compensation up to 500 μm<br />
&#8211; Automatic calibration<br />
&#8211; Adjustable backlighting<br />
&#8211; Internal rechargeable battery<br />
&#8211; Portable, handheld<br />
&#8211; User friendly<br />
&#8211; Samples of Titanium 1.03% IACS, Bronze 8.11% IACS, and Copper 100% IACS<br />
&#8211; incl. ISO Calibration Certificate</p>
<table>
<tbody>
<tr>
<td>Operating frequency</td>
<td>60 kHz, sine wave</td>
</tr>
<tr>
<td>Conductivity measuring range</td>
<td>0.51% IACS &#8230; 112% IACS<br />
0.3 MS/m &#8230; 65 MS/m</td>
</tr>
<tr>
<td>Resistance range</td>
<td>0.015388 &#8230; 3.33333 Ω • mm² / m</td>
</tr>
<tr>
<td>Conductivity measuring resolution</td>
<td>0.01% IACS (at &lt;51% IACS)<br />
0.1% IACS (at 51% IACS &#8230; 112% IACS)</td>
</tr>
<tr>
<td>Conductivity measuring accuracy</td>
<td>± 0.5% at 20°C / 68°F<br />
± 1% in the range 0 &#8230; 40°C / 32 &#8230; 104°F</td>
</tr>
<tr>
<td>Lift-off compensation</td>
<td>0.5 mm / ≈ 0.0197 in</td>
</tr>
<tr>
<td>Temperature measuring range</td>
<td>0 &#8230;  50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td>Temperature measuring accuracy</td>
<td>± 0.5°</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>Automatic adjustment of conductivity result to the value at 20°C / 68°F</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F, 0 &#8230; 95% relative humidity (RH)</td>
</tr>
<tr>
<td>Display</td>
<td>LCD, backlit</td>
</tr>
<tr>
<td>Menu languages</td>
<td>English, German, Chinese (simplified)</td>
</tr>
<tr>
<td>Power supply</td>
<td>Internal, rechargeable battery</td>
</tr>
<tr>
<td>Probe diameter</td>
<td>14 mm / ≈ 0.55 in</td>
</tr>
<tr>
<td>Memory</td>
<td>Stores up to 500 groups of measurement values</td>
</tr>
<tr>
<td>Data interface</td>
<td>USB port connection</td>
</tr>
<tr>
<td>Dimensions</td>
<td>≈ 220 x 95 x 35 mm / 8.66 x 3.74 x 1.38 in</td>
</tr>
<tr>
<td>Weight</td>
<td>≈ 415 g / 1 lb (with probe)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-tester-for-metals-pce-com-20-ica-incl-iso-cal/">Surface Testing &#8211; Conductivity Tester for Metals PCE-COM 20-ICA incl. ISO Cal.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-tester-for-metals-pce-com-20-ica-incl-iso-cal/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17919</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Conductivity Meter for Metals PCE-COM 20</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-meter-for-metals-pce-com-20/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-meter-for-metals-pce-com-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 02:53:31 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17915</guid>

					<description><![CDATA[<p><strong>PCE-COM 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-meter-for-metals-pce-com-20/">Surface Testing &#8211; Conductivity Meter for Metals PCE-COM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p style="text-align: center"><strong>PCE-COM 20 Surface Testing &#8211; Conductivity Meter for NON-Ferrous Metals<br />
Large measuring range up to 112% IACS or 65 MS/m with lift-off and temperature compensation, memory, PC-compatible software, 60 kHz operating frequency</strong></p>
</div>
<div>
<p>PCE-COM 20 is a portable handheld non-destructive surface testing &#8211; conductivity meter for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper.</p>
<p>Featuring an operating frequency of 60 kHz, the conductivity meter has a large measuring range of 0.51 &#8230; 112% IACS with an accuracy of +/- 0.5% at 20°C / 68°F. Thanks to a resolution of up to 0.01% IACS, automatic temperature compensation (ATC) and lift-off compensation (up to 500 μm), the device ensures quick, easy, accurate and reproducible measurements of coated or corroded pieces during changing ambient conditions.</p>
<p>Measurement of the electrical conductivity of non-ferrous metals, such as aluminum, copper, titanium, magnesium or bronze, is necessary in applications involving electrical conductors and the characterization of alloys. Typical application areas are the assessment of strength differences in heat-treated or hardened materials, the authenticity testing of coin alloys, the verification of alloy inhomogeneities in critical components and the sorting of materials.</p>
<p>The conductivity meter is powered by an internal battery that can be charged via the interface on the bottom of the unit. In addition to the connection for the charging adapter, there is a USB interface allowing for the transfer of measurement data to a PC for more detailed analysis.</p>
</div>
<p>&#8211; Eddy current measuring principle<br />
&#8211; For non-ferrous metals and alloys<br />
&#8211; Non-destructive testing (NDT)<br />
&#8211; 60 kHz operating frequency<br />
&#8211; Large measuring range up to 112% IACS or 65 MS/m<br />
&#8211; Memory for up to 500 groups of measurements<br />
&#8211; Automatic temperature compensation (ATC)<br />
&#8211; Lift-off compensation up to 500 μm<br />
&#8211; Automatic calibration<br />
&#8211; Adjustable backlighting<br />
&#8211; Internal rechargeable battery<br />
&#8211; Portable, handheld<br />
&#8211; User friendly<br />
&#8211; Samples of Titanium 1.03% IACS, Bronze 8.11% IACS, and Copper 100% IACS</p>
<table>
<tbody>
<tr>
<td>Operating frequency</td>
<td>60 kHz, sine wave</td>
</tr>
<tr>
<td>Conductivity measuring range</td>
<td>0.51% IACS &#8230; 112% IACS<br />
0.3 MS/m &#8230; 65 MS/m</td>
</tr>
<tr>
<td>Resistance range</td>
<td>0.015388 &#8230; 3.33333 Ω • mm² / m</td>
</tr>
<tr>
<td>Conductivity measuring resolution</td>
<td>0.01% IACS (at &lt;51% IACS)<br />
0.1% IACS (at 51% IACS &#8230; 112% IACS)</td>
</tr>
<tr>
<td>Conductivity measuring accuracy</td>
<td>± 0.5% at 20°C / 68°F<br />
± 1% in the range 0 &#8230; 40°C / 32 &#8230; 104°F</td>
</tr>
<tr>
<td>Lift-off compensation</td>
<td>0.5 mm / ≈ 0.0197 in</td>
</tr>
<tr>
<td>Temperature measuring range</td>
<td>0 &#8230;  50°C / 32 &#8230; 122°F</td>
</tr>
<tr>
<td>Temperature measuring accuracy</td>
<td>± 0.5°</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>Automatic adjustment of conductivity result to the value at 20°C / 68°F</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50°C / 32 &#8230; 122°F, 0 &#8230; 95% relative humidity (RH)</td>
</tr>
<tr>
<td>Display</td>
<td>LCD, backlit</td>
</tr>
<tr>
<td>Menu languages</td>
<td>English, German, Chinese (simplified)</td>
</tr>
<tr>
<td>Power supply</td>
<td>Internal, rechargeable battery</td>
</tr>
<tr>
<td>Probe diameter</td>
<td>14 mm / ≈ 0.55 in</td>
</tr>
<tr>
<td>Memory</td>
<td>Stores up to 500 groups of measurement values</td>
</tr>
<tr>
<td>Data interface</td>
<td>USB port connection</td>
</tr>
<tr>
<td>Dimensions</td>
<td>≈ 220 x 95 x 35 mm / 8.66 x 3.74 x 1.38 in</td>
</tr>
<tr>
<td>Weight</td>
<td>≈ 415 g / 1 lb (with probe)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-meter-for-metals-pce-com-20/">Surface Testing &#8211; Conductivity Meter for Metals PCE-COM 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-conductivity-meter-for-metals-pce-com-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17915</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-USC 20</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-usc-20/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-usc-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 02:31:34 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17903</guid>

					<description><![CDATA[<p><strong>PCE-USC 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-usc-20/">Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>PCE-USC 20 is a portable or benchtop ultrasonic tester or ultrasonic thickness gauge with a 5.7&#8243; TFT color LCD screen. This ultrasound-based thickness meter uses one or two contact transducers (four different probes included; 90 °, 70 °, 60 °, 45 °) to measure material or wall thickness, detect flaws or defects in welds, and monitor the effects of corrosion on pipes and tanks.</div>
<div></div>
<div>PCE-USC 20 is an ultrasonic thickness gauge used for non-destructive testing (NDT) and inspection in a wide variety of applications in industries such as chemical, oil and gas, metallurgical, manufacturing, quality control, metalworking, welding, machining, engineering, product research and development, construction, transportation and aerospace.</div>
<div></div>
<div>&#8211; Measurement range: 0.5 &#8230; 9999 mm (steel; longitudinal wave)<br />
&#8211; Operating frequency range: 0.5 &#8230; 20 MHz<br />
&#8211; Sound velocity: 1000 &#8230; 15000 m/s (continuously adjustable)<br />
&#8211; AVG and DAC evaluation methods, display and probes delay, damping and reinforcing functions, export and reporting functions<br />
&#8211; Saves up to 500 records to memory<br />
&#8211; Lightweight design for ease of portability<br />
&#8211; Complies with EN12668-1</div>
<div></div>
<div>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="250" height="1">Measurement range</td>
<td valign="top" width="347" height="1">0.5 &#8230; 9999 mm (longitudinal shaft steel), continuously adjustable</td>
</tr>
<tr>
<td valign="top" width="250" height="24">Sound velocity</td>
<td valign="top" width="347" height="24">1000 &#8230; 15000 m/s, continuously adjustable, coarse adjustment</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display delay</td>
<td valign="top" width="347" height="21">-10 &#8230; 2000 mm</td>
</tr>
<tr>
<td valign="top" width="250" height="2">Probe delay</td>
<td valign="top" width="347" height="2">0.00 &#8230; 199.9 µs</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Transmitting impulse</td>
<td valign="top" width="347" height="1">400 V negative signal peaks</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Damping (impulse generator)</td>
<td valign="top" width="347" height="21">50 / 100 / 200 / 500</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Work mode</td>
<td valign="top" width="347" height="21">One- or two-probe measurement</td>
</tr>
<tr>
<td valign="top" width="250" height="11">Operating frequency range</td>
<td valign="top" width="347" height="11">0.5 &#8230; 20 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="5">Pulse repetition frequency</td>
<td valign="top" width="347" height="5">40 / 250 /1000 Hz optional</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Amplification / gain (receiver)</td>
<td valign="top" width="347" height="21">0 &#8230; 110 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Rectification (receiver)</td>
<td valign="top" width="347" height="21">Whole wave, positive half wave, negative half wave, high frequency representation</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Alarm limits</td>
<td valign="top" width="347" height="3">Limit A (Gate A) and Limit B (Gate B),<br />
Adjustable as positive or negative peak with automatic (visual or audible) alarm</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement mode</td>
<td valign="top" width="347" height="3">Limit value  / Extreme value mode</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation horizontal linearity</td>
<td valign="top" width="347" height="3">≤0.1 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation vertical linearity</td>
<td valign="top" width="347" height="3">≤3 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Excess sensitivity</td>
<td valign="top" width="347" height="3">≥62 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Dynamic range</td>
<td valign="top" width="347" height="3">≥40 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Resolution remote field</td>
<td valign="top" width="347" height="21">≥30 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Sampling rate</td>
<td valign="top" width="347" height="21">400 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Measurement data storage</td>
<td valign="top" width="347" height="21">500 records</td>
</tr>
<tr>
<td valign="top" width="250" height="7">Signal reproduction</td>
<td valign="top" width="347" height="7">Permanent recording of signals with the playback of dynamic echoes</td>
</tr>
<tr>
<td valign="top" width="250" height="4">Surface adjustment</td>
<td valign="top" width="347" height="4">Automatic adjustment of the error position of the angled probes</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Automatic amplification</td>
<td valign="top" width="347" height="3">20 &#8230; 80 %, in 1 % steps</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Menu language</td>
<td valign="top" width="347" height="21">English, Chinese</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Interface</td>
<td valign="top" width="347" height="21">USB-A, USB-B, Ethernet</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display</td>
<td valign="top" width="347" height="21">5.7 &#8221; TFT color LCD (640 x 480 pixels)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Operating temperature</td>
<td valign="top" width="347" height="21">-10 &#8230; +50 °C</td>
</tr>
<tr>
<td valign="top" width="250" height="40">Power supply</td>
<td valign="top" width="347" height="40">AC: 100 &#8230; 240 V<br />
DC: 15 V / 4 A</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery</td>
<td valign="top" width="347" height="21">Li-ion battery (10.8 V, 5200 mAh)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery opearting time per charge</td>
<td valign="top" width="347" height="21">&gt;6 hours</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Protection class</td>
<td valign="top" width="347" height="21">IP54</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Weight</td>
<td valign="top" width="347" height="21">1.4 kg (incl. battery)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-usc-20/">Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-usc-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17903</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Colorimeter PCE-CSM 8</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-8/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-8/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 22 Apr 2021 01:56:38 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17897</guid>

					<description><![CDATA[<p><strong>PCE-CSM 8</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-8/">Surface Testing &#8211; Colorimeter PCE-CSM 8</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>Colorimeter PCE-CSM 8 for quality control</strong></div>
<div style="text-align: center"><strong>PC software included / Li-ion battery / different colour spaces / black and white calibration</strong></div>
<div style="text-align: center"><strong>determination of reference values and samples / white calibration / 3.5&#8243; touch screen<br />
</strong></div>
</div>
<div>
<div>
<p>The colorimeter PCE-CSM 8 was developed for quality control, offers a high accuracy and comes with a 3.5&#8243; touch screen display. When using the colorimeter, you can choose between different colour spaces (CIE LAB, XYZ, Yxy, LCh, LUV) and 45/0 optics geometry. After a measurement with the colorimeter, the reading can be used as a reference value while other readings can be recorded as a sample and later be compared to the alphanumeric reference value easily.</p>
</div>
<div>In addition to the individual colour space coordinates, the deviation between the reading is also displayed. When using the colorimeter, it is possible to store up to 1000 reference values and up to 10000 samples on the device. The measured data can also be transferred to a PC via the USB interface. A special PC software is included in the package.</div>
<div></div>
</div>
<div>
<div>&#8211; CIE LAB, XYZ, Yxy, LCh, and LUV<br />
&#8211; SCI and SCE (specular excluded)<br />
&#8211; 3.5&#8243; touch screen display<br />
&#8211; 13 light source options<br />
&#8211; white and black calibration<br />
&#8211; 1000 alphanumeric reference values and up to 10,000 sample values memory<br />
&#8211; WI, YI, TI, Mt, Color Stain, Color Fastness, SCI and SCE option (specular included and excluded)<br />
&#8211; Measuring aperture of 8 mm and 45°/0° illumination/viewing angle</div>
<div>&#8211; rechargeable lithium-ion battery<br />
&#8211; high accuracy with Delta E*ab 0.04<br />
&#8211; incl. PC software</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top" width="50%">Measuring geometry</td>
<td valign="top" width="50%">45/0 according to CIE No. 15, GB/T3978</td>
</tr>
<tr>
<td valign="top" width="50%">Integrating sphere</td>
<td valign="top" width="50%">Ø 58 mm</td>
</tr>
<tr>
<td valign="top" width="50%">Sensor</td>
<td valign="top" width="50%">Silicon photoelectric diode</td>
</tr>
<tr>
<td valign="top" width="50%">Wavelength range</td>
<td valign="top" width="50%">400 &#8230; 700 nm (10 nm pitch)</td>
</tr>
<tr>
<td valign="top" width="50%">Measuring aperture</td>
<td valign="top" width="50%">Ø 8 mm</td>
</tr>
<tr>
<td valign="top" width="50%">Colour spaces</td>
<td valign="top" width="50%">CIE LAB, XYZ, Yxy, LCh, LUV</td>
</tr>
<tr>
<td valign="top" width="50%">Colour index</td>
<td valign="top" width="50%">ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔE(h)</td>
</tr>
<tr>
<td valign="top" width="50%">Chromacity data</td>
<td valign="top" width="50%">WI (ASTM E31 CIE/ISO, AATCC, Hunter)<br />
YI (ASTM D1925, ASTM E313)<br />
TI (ASTM E313, CIE/ISO)<br />
Metamerism Index Mt<br />
colour stain, colour fastness</td>
</tr>
<tr>
<td valign="top" width="50%">Observation angle</td>
<td valign="top" width="50%">2° / 10°</td>
</tr>
<tr>
<td valign="top" width="50%">Light source</td>
<td valign="top" width="50%">D65, A, C, D50, D55, D75, F2, F6, F7, F8, F10, F11, F12</td>
</tr>
<tr>
<td valign="top" width="50%">Light source device</td>
<td valign="top" width="50%">combined LED</td>
</tr>
<tr>
<td valign="top" width="50%">Life of light source</td>
<td valign="top" width="50%">5 years, &gt; 1.6 million measurements</td>
</tr>
<tr>
<td valign="top" width="50%">Data on display</td>
<td valign="top" width="50%">Spectral value/graph<br />
colorimetric value<br />
color difference (value/graph)<br />
PASS/FAIL result<br />
colour offset<br />
colour simulation</td>
</tr>
<tr>
<td valign="top" width="50%">Min. time between 2 measurements</td>
<td valign="top" width="50%">1.5 seconds</td>
</tr>
<tr>
<td valign="top" width="50%">Repeatability</td>
<td valign="top" width="50%">Standard deviation within ΔE*ab 0.04<br />
Average of 30 measurements of standard white plate</td>
</tr>
<tr>
<td valign="top" width="50%">Error between equipment</td>
<td valign="top" width="50%">ΔE*ab 0.2</td>
</tr>
<tr>
<td valign="top" width="50%">Display</td>
<td valign="top" width="50%">3.5&#8243; TFT touch screen</td>
</tr>
<tr>
<td valign="top" width="50%">Interface</td>
<td valign="top" width="50%">USB / RS232</td>
</tr>
<tr>
<td valign="top" width="50%">Storage</td>
<td valign="top" width="50%">1,000 reference values, 15,000 samples</td>
</tr>
<tr>
<td valign="top" width="50%">Power supply</td>
<td valign="top" width="50%">Rechargeable lithium-ion battery</td>
</tr>
<tr>
<td valign="top" width="50%">Operating conditions</td>
<td valign="top" width="50%">0 &#8230; +40 °C / 32 &#8230; 104°F<br />
0 &#8230; 85 % RH</td>
</tr>
<tr>
<td valign="top" width="50%">Storage conditions</td>
<td valign="top" width="50%">-20 &#8230; +50 °C / -4 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top" width="50%">Dimensions</td>
<td valign="top" width="50%">90 x 77 x 230 mm / 3.5 x 3.03 x 9.05 in</td>
</tr>
<tr>
<td valign="top" width="50%">Weight</td>
<td valign="top" width="50%">600 g / 21.1 oz</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-8/">Surface Testing &#8211; Colorimeter PCE-CSM 8</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-8/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17897</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-FD 20</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-fd-20/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-fd-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 21 Apr 2021 09:52:35 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17892</guid>

					<description><![CDATA[<p><strong>PCE-FD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-fd-20/">Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>PCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.</div>
<div></div>
<div>&#8211; Operating frequency range: 1 &#8230; 10 MHz<br />
&#8211; Measured time interval range: 6 &#8230; 1000 microseconds (µs)<br />
&#8211; Sound velocity: 1000 &#8230; 9999 m/s<br />
&#8211; Implements shadow, echo and mirror-shadow testing methods<br />
&#8211; Features a USB interface for downloading data to PC for detailed analysis<br />
&#8211; Lightweight<br />
&#8211; Battery or electric power<br />
&#8211; 1.5 m long probe cable</div>
<div></div>
<div>
<table class="tech" border="0">
<tbody>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measure time interval range (scan duration)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">6 &#8230; 1000 microseconds (µs)</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Sound velocity range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1000 &#8230; 9999 m/s</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of measurement of time intervals</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.025 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Max. deviation of amplitude of signals at receiver input in 0 &#8230; 110 dB range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.5 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Testing gain region</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">125 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Averaging over the quantity of starts</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 16</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Range of time-variable gain (TVG) / Number of control points TVG</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">40 dB / 15</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Duration of excitation pulse to load</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 0.5 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Amplitude of excitation pulse to 50 Ohm load, not less</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">100, 200, 300</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range of receiver at -3 dB</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of amplitudes of input signals in 10 &#8230; 100% range of screen height</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Not more than 1 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measurement range of time intervals</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Prism of probe delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 15 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Automatic signaling of defects (AFS)</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dual-gate</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Setting range of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Adjusting thresholds of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 100%</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Detection of signals (receiver)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Positive half-wave, radio mode</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions of device (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">80 x 162 x 35 mm / 3.14 x 6.37 x 1.37&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions display (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">48 x 74 mm / 1.88 x 2.91&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Power supply</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">100 &#8230; 250 V AC or 3 x 1.5 V AA batteries</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Weight (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">250 g / 0.55 lb (without batteries)</p>
</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-fd-20/">Surface Testing &#8211; Ultrasonic Thickness Gauge PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-ultrasonic-thickness-gauge-pce-fd-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17892</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Colorimeter PCE-TCR 200</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-tcr-200/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-tcr-200/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 21 Apr 2021 09:50:40 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17889</guid>

					<description><![CDATA[<p><strong>PCE-TCR 200</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-tcr-200/">Surface Testing &#8211; Colorimeter PCE-TCR 200</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Precise measurement of color according to CIE standards / measures differences of colors and shows <span lang="EN-US">Δ</span>E / for several surfaces / memory / USB interfaces / PC software for color evaluation</strong></div>
<div>
<p>The PCE-TCR 200 color device carries out an analysis of the color using CIE L*a*b color space. This color device also allows you to determine the colors in the RGB color range. By means of a source of internal normalized white light the surface is illuminated. The color device absorbs the light reflected from the background and processes it. In addition of indicating the Lab colors, this color device also shows RGB, Lch and HCL colour ranges.</p>
<p>The PCE-TCR 200 color device can also detect the distance <span lang="EN-US">Δ</span>E between different color pattern. This color device allows you to set a limited value which should not be exceeded. The PCE-TCR 200 color device checks each measurement to see if it has exceeded the threshold value. Measurement of color is taken by means of a high precision silicon sensor. The sensor detects the light reflected according to the regulations of light source D65, D50 or F11, which can be selected using the menu. The internal memory of the color device is able to store 30 color values into 12 groups. That allows a fast control of the color values. This color device is powered by 4 AA batteries.</p>
<p>It can also be powered by an external power plug. The measurement values can be transferred from the color device to a PC, using a USB port. The PCE-TCR 200 color device will be delivered in a resistant aluminium case. The following is also included in the delivery: Black and white test standards, a network component, a USB cable for data transmission and a case to ensure safe transportation of the color device PCE-TR 200. If there are any questions about the color device PCE-TCR 200  have a look at the technical specification below. Our technicians and engineers will gladly advise you in all color devices and all products in the field of measuring instruments, regulation and control and scales.</p>
</div>
<div>
<div>&#8211; Measurement of Lab color values<br />
&#8211; Specular Component Included (SCI)<br />
&#8211; Conversion into LCH, RGB&#8230;<br />
&#8211; High repeatability<br />
&#8211; Selection of three light sources<br />
&#8211; Balancing of white and black objects</div>
<div>&#8211; USB input<br />
&#8211; Software for evaluation of the measured values<br />
&#8211; Memory of values<br />
&#8211; Sleep function to reduce power consumption<br />
&#8211; Aluminium transportation case</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top" width="50%" height="16">Repeatability</td>
<td valign="top" width="50%" height="16">0.08</td>
</tr>
<tr>
<td valign="top" width="50%" height="16">Illumination System</td>
<td valign="top" width="50%" height="16">8/d, SCI</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Light source</td>
<td valign="top" width="50%" height="8">standard white light</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Detection angle</td>
<td valign="top" width="50%" height="8">10º according to CIE standard</td>
</tr>
<tr>
<td valign="top" width="50%" height="16">Detection conditions</td>
<td valign="top" width="50%" height="16">D65, D50, F11</td>
</tr>
<tr>
<td valign="top" width="50%" height="16">Balancing of measured values</td>
<td valign="top" width="50%" height="16">standard white according to CIE, standard black according to CIE</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Memory</td>
<td valign="top" width="50%" height="8">12 groups with 30 values each</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Display</td>
<td valign="top" width="50%" height="8">L*a*b*, L*c*h*, E*ab, RGB<br />
chromatic aberration of L*a*b* and L*c*h*</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Diameter</td>
<td valign="top" width="50%" height="8">8 mm</td>
</tr>
<tr>
<td valign="top" width="50%" height="8">Voltage Supply</td>
<td valign="top" width="50%" height="8">4 x AA 1.5 V, external 5 V power plug</td>
</tr>
<tr>
<td valign="top" width="50%" height="16">OS Comaptibility</td>
<td valign="top" width="50%" height="16">Windows XP, Windows Vista, Windows 7</td>
</tr>
<tr>
<td valign="top" width="50%" height="16">Dimentions</td>
<td valign="top" width="50%" height="16">60 x 110 x 40 mm / 2.3 x 4.3 x 1.5 in</td>
</tr>
<tr>
<td colspan="2" valign="top" width="100%" height="4"><strong>Regulations to evaluate color measurements with the Color Device PCE-TCR 200</strong></td>
</tr>
<tr>
<td valign="top" width="50%" height="1">Range of color differences</td>
<td valign="top" width="50%" height="1">Valuation</td>
</tr>
<tr>
<td valign="top" width="50%" height="1">0 &#8230; 0.25 <span lang="EN-US">Δ</span>E</td>
<td valign="top" width="50%" height="1">small deviation, deviation acceptable</td>
</tr>
<tr>
<td valign="top" width="50%" height="1">0.25 &#8230; 0.5 <span lang="EN-US">ΔE</span></td>
<td valign="top" width="50%" height="1">less chromatic aberration, acceptable in a few applications</td>
</tr>
<tr>
<td valign="top" width="50%">0.5 &#8230; 1.0 <span lang="EN-US">ΔE</span></td>
<td valign="top" width="50%" height="1">less or average chromatic aberration, acceptable in a few applications</td>
</tr>
<tr>
<td valign="top" width="50%" height="0">1.0 &#8230; 2.0 <span lang="EN-US">ΔE</span></td>
<td valign="top" width="50%" height="0">average deviation of colours, acceptable in a few applications</td>
</tr>
<tr>
<td valign="top" width="50%" height="0">2.0 &#8230; 4.0 <span lang="EN-US">ΔE</span></td>
<td valign="top" width="50%" height="0">high colour deviation, only acceptable in special applications</td>
</tr>
<tr>
<td valign="top" width="50%" height="0">&gt; 4.0 <span lang="EN-US">ΔE</span></td>
<td valign="top" width="50%" height="0">really high colour deviation, not acceptable</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-tcr-200/">Surface Testing &#8211; Colorimeter PCE-TCR 200</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-tcr-200/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17889</post-id>	</item>
		<item>
		<title>Surface Testing &#8211; Colorimeter PCE-CSM 7</title>
		<link>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-7/</link>
					<comments>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-7/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 21 Apr 2021 09:44:32 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=17885</guid>

					<description><![CDATA[<p><strong>PCE-CSM 7</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-7/">Surface Testing &#8211; Colorimeter PCE-CSM 7</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>Colorimeter PCE-CSM 7<br />
Automatic black and white calibration / Rechargeable battery / PC software included<br />
</strong></div>
<div>
<p>PCE-CSM 7 is a portable colorimeter used to measure different spectral parameters. This user-friendly, ergonomically designed colorimeter automatically performs a white and black calibration when powered on. Suitable for manufacturing quality control and assurance as well as product research and development, the colorimeter offers impressive measuring accuracy and comes manufacturer calibrated. An optional ISO calibration certificate can be acquired as an accessory for an additional fee. Integrated camera and illumination locating for small samples.</p>
<p>When using the color meter, different color spaces can be selected (CIEL*a*b*C*h*, CIEL*a*b*, CIEXYZ, CIERGB, CIEL*u*v*, CIEL*C*h + Yellowness + Whiteness + Color Fastness). The color meter also offers two different measuring apertures (Ø 4 mm and Ø 8 mm) for different applications. In addition to the individual color space coordinates, deviations between readings are displayed. For example, after taking a measurement with the PCE-CSM 7, a reading can be saved and used as a standard reference value against which other readings can be compared. Up to 100 reference values and up to 20,000 samples can be stored to the internal memory of the colorimeter. The measured data can be transferred to a PC via USB and analyzed using the included PC-compatible software.</p>
</div>
</div>
<div>
<div>&#8211; Rechargeable Lithium-Ion battery<br />
&#8211; Automatic white and black calibration<br />
&#8211; Determines degree of whiteness and yellowness<br />
&#8211; Different measurement modes for different colors<br />
&#8211; Includes PC-compatible software for detailed color analysis<br />
&#8211; Offers two different measuring apertures (Ø 4 mm and Ø 8 mm)<br />
&#8211; Yellowness and Whiteness color fastness<br />
&#8211; CIE 1976 and 1994 Delta options<br />
&#8211; 3 light source options<br />
&#8211; 8 mm extended aperture option for concave surfaces<br />
&#8211; Camera/illumination locating for small samples</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td>Illuminating / Viewing Geometry</td>
<td>8/d</td>
</tr>
<tr>
<td>Measuring Aperture</td>
<td>Ø 4 mm / Ø 8 mm</td>
</tr>
<tr>
<td>Detector</td>
<td>Silicon photoelectric diode</td>
</tr>
<tr>
<td>Color Space</td>
<td>CIEL*a*b*C*h<br />
CIEL a* b*<br />
CIEXYZ<br />
CIERGB<br />
CIEL u* v*<br />
CIEL*C*h°<br />
Yellowness &amp; Whiteness Color Fastness</td>
</tr>
<tr>
<td>Color Difference Formula</td>
<td>ΔE*ab; ΔL*ab; ΔE*C*H; ΔECIE94; ΔEHunter</td>
</tr>
<tr>
<td>Light Source</td>
<td>D65, D50, A</td>
</tr>
<tr>
<td>Light Source Device</td>
<td>LED light excitation</td>
</tr>
<tr>
<td>Errors Between Devices</td>
<td>&lt;=0.40 ΔE*ab</td>
</tr>
<tr>
<td>Storage</td>
<td>100 pcs. standards, 20,000 pcs. samples</td>
</tr>
<tr>
<td>Repeatability</td>
<td>Standard deviation within ΔE*ab 0.06<br />
Average of 30 measurements of standard white plate</td>
</tr>
<tr>
<td>Weight</td>
<td>500 g / 1.11 lbs</td>
</tr>
<tr>
<td>Dimensions</td>
<td>205 x 70 x 100 mm / 8 x 2.7 x 3.9&#8243;</td>
</tr>
<tr>
<td>Power Source</td>
<td>Rechargeable Lithium-Ion battery 3.7 V</td>
</tr>
<tr>
<td>Charging Time</td>
<td>8 hours</td>
</tr>
<tr>
<td>Measuring Times Before Recharging</td>
<td>More than 3000 times</td>
</tr>
<tr>
<td>Lamp Life</td>
<td>5 years or more than 1.6 million measurements</td>
</tr>
<tr>
<td>Operating Temperature / Humidity Range</td>
<td>-10 &#8230; +40 °C / 14 &#8230; 104 °F; 0 &#8230; 85% relative humidity, non condensation</td>
</tr>
<tr>
<td>Data Interface</td>
<td>USB</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-7/">Surface Testing &#8211; Colorimeter PCE-CSM 7</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/surface-testing/surface-testing-colorimeter-pce-csm-7/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">17885</post-id>	</item>
	</channel>
</rss>