<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Thickness Gauge - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/thickness-gauge/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/thickness-gauge/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Fri, 18 Nov 2022 04:53:12 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Thickness Gauge - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/thickness-gauge/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Thickness Gauge PCE-USC 30</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-usc-30/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-usc-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:29:39 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18472</guid>

					<description><![CDATA[<p><strong>PCE-USC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-usc-30/">Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Portable </strong><strong>thickness gauge for NDT / NDT testing of surfaces / Coating thickness measurement using eddy current / Conductivity measurement of metals according to IACS / Material sorting</strong></div>
<p>The thickness gauge is used in non-destructive material testing. With the eddy current testing device, surface defects and near-surface defects can be made visible. Eddy current testing is an electrical method for testing electrically conductive materials. In the eddy current test, a probe charged with alternating voltage is placed on an electrically conductive test piece. The magnetic field lines generated perpendicular to the workpiece surface induce circular eddy currents close to the surface, creating secondary magnetic fields in the test piece. The secondary fields counteract the primary fields and measurably change them in terms of amplitude and phase. Inhomogeneities and workpiece defects change the eddy current curves and the permeability of the material and thus also the secondary fields. In this way, defects close to the surface can be located and classified.</p>
<p>The thickness gauge is designed for corresponding NDT material tests and can also be used for conductivity measurement and layer thickness determination.</p>
<p>The ergonomic design of the thickness gauge, a weight of less than 1 kg, a battery life of approx. 8 hours, a large selection of probes to cover a wide frequency range up to 3.5 MHz, as well as software for generating reports are good prerequisites for effective and pleasant work.</p>
<p>The thickness gauge is therefore ideally suited for non-destructive material testing in the aerospace sector for component testing of e.g. turbine blades or bores, for welding seam testing and crack testing, for pipeline and container testing in the chemical, oil and gas industry or in the field of mechanical engineering for quality control of semi-finished products, sheet, strip products or individual components. The testing of material properties is also possible via a microstructure comparison, so that checks for mix-ups can also be carried out.</p>
<p>&#8211; Large frequency range<br />
&#8211; 4.3&#8243; large colour display (TFT)<br />
&#8211; NDT testing of surfaces<br />
&#8211; Sorting of material<br />
&#8211; Frequency range up to 3.5 MHz<br />
&#8211; Battery life approx. 8 hours</p>
<table>
<tbody>
<tr>
<td>Frequency range</td>
<td>0.01 &#8230; 16000 kHz</td>
</tr>
<tr>
<td>Probe voltage supply</td>
<td>0, 5, 1, 2, 4, 6 V</td>
</tr>
<tr>
<td>Signal phase shift</td>
<td>0 &#8230; 360°</td>
</tr>
<tr>
<td>Sampling frequency</td>
<td>0 &#8230; 10 kHz</td>
</tr>
<tr>
<td>Duration of signal fade-in</td>
<td>0 / 0.5 / 1 / 2 / 3 / 4 seconds</td>
</tr>
<tr>
<td valign="top">Alarm</td>
<td>circular<br />
horizontal line<br />
circle sector<br />
cut-off</td>
</tr>
<tr>
<td>Display</td>
<td>full-colour display (TFT)</td>
</tr>
<tr>
<td>Display size</td>
<td>4.3&#8243; (diagonal)</td>
</tr>
<tr>
<td>Display resolution</td>
<td>800 x 480 pixels</td>
</tr>
<tr>
<td>Amplification adjustment</td>
<td>0 &#8230; 100 dB</td>
</tr>
<tr>
<td valign="top">Filter</td>
<td>low pass filter (1 &#8230; 4000 Hz)<br />
high pass filter (1 &#8230; 4000 Hz)<br />
band filter<br />
differential filter<br />
average value filter</td>
</tr>
<tr>
<td>Average interval between measurement errors</td>
<td>4000 hours</td>
</tr>
<tr>
<td>Power supply</td>
<td>12 V battery</td>
</tr>
<tr>
<td>Battery capacity</td>
<td>4500 mAh</td>
</tr>
<tr>
<td>Continuous runtime per battery charge</td>
<td>&gt;8 hours</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>-20 &#8230; +45 °C</td>
</tr>
<tr>
<td>Weight</td>
<td>&lt;0.9 kg</td>
</tr>
<tr>
<td>Dimensions</td>
<td>230 x 135 x 98 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-usc-30/">Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-usc-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18472</post-id>	</item>
		<item>
		<title>Paint Thickness Tester PCE-USC 30</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/paint-thickness-tester-pce-usc-30/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/paint-thickness-tester-pce-usc-30/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:27:28 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18465</guid>

					<description><![CDATA[<p><strong>PCE-USC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/paint-thickness-tester-pce-usc-30/">Paint Thickness Tester PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 30 is a coating thickness gauge designed for the non-destructive testing (NDT) and non-destructive evaluation (NDE) of electrically conductive materials. This portable, handheld thickness meter detects surface defects and measures layer thicknesses using an eddy current. The PCE-USC 30 material tester also measures metal conductivity in accordance with the International Annealed Copper Standard (IACS).</p>
<p>The PCE-USC 30 thickness gauge has myriad applications including weld seam testing, crack detection, metallurgical and material sorting tests, quality assurance and control, aviation component testing of turbine blades, and pipeline and container testing in the chemical, oil and gas industries.<br />
&#8211; Frequency range: 0.01 &#8230; 16000 kHz<br />
&#8211; Visually depicts surface defects on screen<br />
&#8211; 4.3&#8243; full-color display (TFT)<br />
&#8211; Ergonomic design<br />
&#8211; Long battery life</p>
<p>Frequency range: 0.01 &#8230; 16000 kHz<br />
Probe voltage supply: 0, 5, 1, 2, 4, 6 V<br />
Signal phase shift: 0 &#8230; 360 °<br />
Sampling frequency: 0 &#8230; 10 kHz<br />
Duration of signal superimposition: 0 / 0.5 / 1/2/3/4 seconds<br />
Alarm: Circular, horizontal line, circle sector, cut off<br />
Display: Full-color display (TFT)<br />
Display size: 4.3 &#8220;(diagonal)<br />
Display resolution: 800 x 480 pixels<br />
Amplification adjustment: 0 &#8230; 100 dB<br />
Filters: Low-pass (1 &#8230; 4000 Hz), high-pass (1 &#8230; 4000 Hz), band, differential, average<br />
Average interval between measurement errors: 4000 hours<br />
Power supply: 12 V battery<br />
Battery capacity: 4500 mAh<br />
Continuous runtime per battery charge: Approx. 8 hours<br />
Operating temperature: -20 &#8230; +45 ° C<br />
Weight: Approx. 0.9 kg<br />
Dimensions: 230 x 135 x 98 mm</p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/paint-thickness-tester-pce-usc-30/">Paint Thickness Tester PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/paint-thickness-tester-pce-usc-30/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18465</post-id>	</item>
		<item>
		<title>Coating Thickness Gauge PCE-USC 30</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/coating-thickness-gauge-pce-usc-30-2/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/coating-thickness-gauge-pce-usc-30-2/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:23:55 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18456</guid>

					<description><![CDATA[<p><strong>PCE-USC 30</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/coating-thickness-gauge-pce-usc-30-2/">Coating Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 30 is a coating thickness gauge designed for the non-destructive testing (NDT) and non-destructive evaluation (NDE) of electrically conductive materials. This portable, handheld thickness meter detects surface defects and measures layer thicknesses using an eddy current. The PCE-USC 30 material tester also measures metal conductivity in accordance with the International Annealed Copper Standard (IACS).</p>
<p>The PCE-USC 30 thickness gauge has myriad applications including weld seam testing, crack detection, metallurgical and material sorting tests, quality assurance and control, aviation component testing of turbine blades, and pipeline and container testing in the chemical, oil and gas industries.<br />
&#8211; Frequency range: 0.01 &#8230; 16000 kHz<br />
&#8211; Visually depicts surface defects on screen<br />
&#8211; 4.3&#8243; full-color display (TFT)<br />
&#8211; Ergonomic design<br />
&#8211; Long battery life</p>
<p>Frequency range: 0.01 &#8230; 16000 kHz<br />
Probe voltage supply: 0, 5, 1, 2, 4, 6 V<br />
Signal phase shift: 0 &#8230; 360 °<br />
Sampling frequency: 0 &#8230; 10 kHz<br />
Duration of signal superimposition: 0 / 0.5 / 1/2/3/4 seconds<br />
Alarm: Circular, horizontal line, circle sector, cut off<br />
Display: Full-color display (TFT)<br />
Display size: 4.3 &#8220;(diagonal)<br />
Display resolution: 800 x 480 pixels<br />
Amplification adjustment: 0 &#8230; 100 dB<br />
Filters: Low-pass (1 &#8230; 4000 Hz), high-pass (1 &#8230; 4000 Hz), band, differential, average<br />
Average interval between measurement errors: 4000 hours<br />
Power supply: 12 V battery<br />
Battery capacity: 4500 mAh<br />
Continuous runtime per battery charge: Approx. 8 hours<br />
Operating temperature: -20 &#8230; +45 ° C<br />
Weight: Approx. 0.9 kg<br />
Dimensions: 230 x 135 x 98 mm</p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/coating-thickness-gauge-pce-usc-30-2/">Coating Thickness Gauge PCE-USC 30</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/coating-thickness-gauge-pce-usc-30-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18456</post-id>	</item>
		<item>
		<title>Ultrasonic Thickness Gauge PCE-USC 20</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-usc-20/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-usc-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:21:06 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18451</guid>

					<description><![CDATA[<p><strong>PCE-USC 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-usc-20/">Ultrasonic Thickness Gauge PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 20 is a portable or benchtop ultrasonic tester or ultrasonic thickness gauge with a 5.7&#8243; TFT color LCD screen. This ultrasound-based thickness meter uses one or two contact transducers (four different probes included; 90 °, 70 °, 60 °, 45 °) to measure material or wall thickness, detect flaws or defects in welds, and monitor the effects of corrosion on pipes and tanks.</p>
<p>PCE-USC 20 is an ultrasonic thickness gauge used for non-destructive testing (NDT) and inspection in a wide variety of applications in industries such as chemical, oil and gas, metallurgical, manufacturing, quality control, metalworking, welding, machining, engineering, product research and development, construction, transportation and aerospace.</p>
<p>&#8211; Measurement range: 0.5 &#8230; 9999 mm (steel; longitudinal wave)<br />
&#8211; Operating frequency range: 0.5 &#8230; 20 MHz<br />
&#8211; Sound velocity: 1000 &#8230; 15000 m/s (continuously adjustable)<br />
&#8211; AVG and DAC evaluation methods, display and probes delay, damping and reinforcing functions, export and reporting functions<br />
&#8211; Saves up to 500 records to memory<br />
&#8211; Lightweight design for ease of portability<br />
&#8211; Complies with EN12668-1</p>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="2" valign="top" height="28">
<p align="left"><strong>Technical specifications<br />
</strong></p>
</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Measurement range</td>
<td valign="top" width="347" height="1">0.5 &#8230; 9999 mm (longitudinal shaft steel), continuously adjustable</td>
</tr>
<tr>
<td valign="top" width="250" height="24">Sound velocity</td>
<td valign="top" width="347" height="24">1000 &#8230; 15000 m/s, continuously adjustable, coarse adjustment</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display delay</td>
<td valign="top" width="347" height="21">-10 &#8230; 2000 mm</td>
</tr>
<tr>
<td valign="top" width="250" height="2">Probe delay</td>
<td valign="top" width="347" height="2">0.00 &#8230; 199.9 µs</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Transmitting impulse</td>
<td valign="top" width="347" height="1">400 V negative signal peaks</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Damping (impulse generator)</td>
<td valign="top" width="347" height="21">50 / 100 / 200 / 500</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Work mode</td>
<td valign="top" width="347" height="21">One- or two-probe measurement</td>
</tr>
<tr>
<td valign="top" width="250" height="11">Operating frequency range</td>
<td valign="top" width="347" height="11">0.5 &#8230; 20 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="5">Pulse repetition frequency</td>
<td valign="top" width="347" height="5">40 / 250 /1000 Hz optional</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Amplification / gain (receiver)</td>
<td valign="top" width="347" height="21">0 &#8230; 110 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Rectification (receiver)</td>
<td valign="top" width="347" height="21">Whole wave, positive half wave, negative half wave, high frequency representation</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Alarm limits</td>
<td valign="top" width="347" height="3">Limit A (Gate A) and Limit B (Gate B),<br />
Adjustable as positive or negative peak with automatic (visual or audible) alarm</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement mode</td>
<td valign="top" width="347" height="3">Limit value  / Extreme value mode</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation horizontal linearity</td>
<td valign="top" width="347" height="3">≤0.1 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation vertical linearity</td>
<td valign="top" width="347" height="3">≤3 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Excess sensitivity</td>
<td valign="top" width="347" height="3">≥62 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Dynamic range</td>
<td valign="top" width="347" height="3">≥40 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Resolution remote field</td>
<td valign="top" width="347" height="21">≥30 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Sampling rate</td>
<td valign="top" width="347" height="21">400 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Measurement data storage</td>
<td valign="top" width="347" height="21">500 records</td>
</tr>
<tr>
<td valign="top" width="250" height="7">Signal reproduction</td>
<td valign="top" width="347" height="7">Permanent recording of signals with the playback of dynamic echoes</td>
</tr>
<tr>
<td valign="top" width="250" height="4">Surface adjustment</td>
<td valign="top" width="347" height="4">Automatic adjustment of the error position of the angled probes</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Automatic amplification</td>
<td valign="top" width="347" height="3">20 &#8230; 80 %, in 1 % steps</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Menu language</td>
<td valign="top" width="347" height="21">English, Chinese</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Interface</td>
<td valign="top" width="347" height="21">USB-A, USB-B, Ethernet</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display</td>
<td valign="top" width="347" height="21">5.7 &#8221; TFT color LCD (640 x 480 pixels)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Operating temperature</td>
<td valign="top" width="347" height="21">-10 &#8230; +50 °C</td>
</tr>
<tr>
<td valign="top" width="250" height="40">Power supply</td>
<td valign="top" width="347" height="40">AC: 100 &#8230; 240 V<br />
DC: 15 V / 4 A</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery</td>
<td valign="top" width="347" height="21">Li-ion battery (10.8 V, 5200 mAh)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery opearting time per charge</td>
<td valign="top" width="347" height="21">&gt;6 hours</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Protection class</td>
<td valign="top" width="347" height="21">IP54</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Weight</td>
<td valign="top" width="347" height="21">1.4 kg (incl. battery)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-usc-20/">Ultrasonic Thickness Gauge PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-usc-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18451</post-id>	</item>
		<item>
		<title>Ultrasonic Thickness Gauge PCE-FD 20</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-fd-20/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-fd-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:17:44 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18446</guid>

					<description><![CDATA[<p><strong>PCE-FD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-fd-20/">Ultrasonic Thickness Gauge PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.</p>
<p>&#8211; Operating frequency range: 1 &#8230; 10 MHz<br />
&#8211; Measured time interval range: 6 &#8230; 1000 microseconds (µs)<br />
&#8211; Sound velocity: 1000 &#8230; 9999 m/s<br />
&#8211; Implements shadow, echo and mirror-shadow testing methods<br />
&#8211; Features a USB interface for downloading data to PC for detailed analysis<br />
&#8211; Lightweight<br />
&#8211; Battery or electric power<br />
&#8211; 1.5 m long probe cable</p>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td><strong>Technical specifications</strong></td>
</tr>
</tbody>
</table>
<table class="tech" border="0">
<tbody>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measure time interval range (scan duration)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">6 &#8230; 1000 microseconds (µs)</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Sound velocity range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1000 &#8230; 9999 m/s</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of measurement of time intervals</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.025 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Max. deviation of amplitude of signals at receiver input in 0 &#8230; 110 dB range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.5 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Testing gain region</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">125 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Averaging over the quantity of starts</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 16</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Range of time-variable gain (TVG) / Number of control points TVG</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">40 dB / 15</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Duration of excitation pulse to load</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 0.5 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Amplitude of excitation pulse to 50 Ohm load, not less</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">100, 200, 300</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range of receiver at -3 dB</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of amplitudes of input signals in 10 &#8230; 100% range of screen height</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Not more than 1 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measurement range of time intervals</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Prism of probe delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 15 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Automatic signaling of defects (AFS)</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dual-gate</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Setting range of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Adjusting thresholds of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 100%</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Detection of signals (receiver)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Positive half-wave, radio mode</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions of device (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">80 x 162 x 35 mm / 3.14 x 6.37 x 1.37&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions display (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">48 x 74 mm / 1.88 x 2.91&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Power supply</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">100 &#8230; 250 V AC or 3 x 1.5 V AA batteries</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Weight (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">250 g / 0.55 lb (without batteries)</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-fd-20/">Ultrasonic Thickness Gauge PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/ultrasonic-thickness-gauge-pce-fd-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18446</post-id>	</item>
		<item>
		<title>Thickness Gauge PCE-CT 90-ICA Incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:15:38 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18442</guid>

					<description><![CDATA[<p><strong>PCE-CT 90-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90-ica-incl-iso-calibration-certificate/">Thickness Gauge PCE-CT 90-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Thickness Gauge PCE-CT 90-ICA Incl. ISO Calibration Certificate<br />
Coating thickness gauge with various sensors / Measuring range up to 60 mm /  Automatic sensor detection / Temperature, roughness, dew point, ambient humidity / Coating thickness measurement for Fe and NFe measurements / For mobile use</strong></div>
<div></div>
<div>The coating thickness gauge is a versatile measuring instrument. This is made possible by the various optional sensors on the layer thickness gauge. For example, the coating thickness gauge can easily measure the layer thicknesses of paints, galvanic coatings, galvanizing or even anodic oxide layers on metal. With the sensors, for example, layer thickness measurements with a thickness of up to 60 mm are possible.</div>
<div></div>
<div>In addition to the layer thickness sensors for the layer thickness gauge, there is also the climate sensor. With this climate sensor at the coating thickness gauge, the ambient temperature, the ambient humidity and the dew point can be measured. Also, in the film thickness gauge, there is the surface temperature sensor. Thanks to the surface temperature sensor, the surface temperature of an object in a measuring range of -50 &#8230; 125°C / -58 &#8230; 257°F can be determined with the Coating Thickness Gauge.</div>
<div></div>
<div>In addition, the roughness of surfaces can be determined with the layer thickness gauge. This is made possible by the optional roughness meter. With the roughness sensor from the layer thickness gauge, the Rz value of the surface can be determined within a very short time. The measuring range here is between 0 &#8230; 300 μm.</div>
<div></div>
<div>&#8211; Different sensors<br />
&#8211; Measuring range up to 60 mm<br />
&#8211; Automatic sensor detection<br />
&#8211; Zero point and one-point calibration<br />
&#8211; Power supply 2 x 1.5V AAA batteries<br />
&#8211; Temperature measurement up to 125°C / 257°F <strong><br />
</strong>&#8211; Incl. ISO calibration certificate</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="2" valign="top">Measuring range</td>
<td colspan="2" valign="top">sensor-dependent (see sensor table)</td>
</tr>
<tr>
<td colspan="2" valign="top">Accuracy</td>
<td colspan="2" valign="top">sensor-dependent (see sensor table)</td>
</tr>
<tr>
<td colspan="2" valign="top">Measurable materials</td>
<td colspan="2" valign="top">magnetic materials (iron, steel &#8230;)<br />
non-magnetic materials<br />
(paints, plastics, ceramics, …)</td>
</tr>
<tr>
<td colspan="2" valign="top">Min. radius of curvature</td>
<td colspan="2" valign="top">0.3 … 50 mm / <span>0.012 &#8230; 1.97&#8243; </span>(<span>depending on the sensor used</span>)</td>
</tr>
<tr>
<td colspan="2" valign="top">Calibration</td>
<td colspan="2" valign="top">Zero calibration, one-point calibration</td>
</tr>
<tr>
<td colspan="2" valign="top">Units</td>
<td colspan="2" valign="top">µm, mm, °C</td>
</tr>
<tr>
<td colspan="2" valign="top">Power supply</td>
<td colspan="2" valign="top">2 x 1.5 V AAA batteries (DC)</td>
</tr>
<tr>
<td colspan="2" valign="top">Display</td>
<td colspan="2" valign="top">Graphic display</td>
</tr>
<tr>
<td colspan="2" valign="top">Operating conditions</td>
<td colspan="2" valign="top">-10 &#8230; 40 °C / 14 &#8230; 104 °F, 20 &#8230; 98% r. H., non-condensing at 35 °C / 95 °F</td>
</tr>
<tr>
<td colspan="2" valign="top">Storage conditions</td>
<td colspan="2" valign="top">5 &#8230; 40 °C / 41 &#8230; 104°F, 80% r. H., non-condensing at 25 °C / 77 °F</td>
</tr>
<tr>
<td colspan="2" valign="top">Dimensions</td>
<td colspan="2" valign="top">136 x 75 x 32 mm / 5.4 x 3 x 1.3&#8243;</td>
</tr>
<tr>
<td colspan="2" valign="top">Weight</td>
<td colspan="2" valign="top">168 g / &lt; 1 lb</td>
</tr>
<tr>
<td colspan="2" valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Sensor table</strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top" width="62"><strong>Model</strong></td>
<td valign="top" width="176"><strong><span>Measuring range</span></strong></td>
<td valign="top" width="168"><strong><span>Accuracy</span></strong></td>
<td valign="top" width="178"><strong><span>Measurement Description</span></strong></td>
</tr>
<tr>
<td valign="top"><strong>Fe-0.3*</strong></td>
<td valign="top">0 &#8230; 300 µm</td>
<td valign="top">±(3 % + 1 µm)</td>
<td valign="top">Paint, lacquer, galvanic coating</td>
</tr>
<tr>
<td valign="top"><strong>Fe-0.5*</strong></td>
<td valign="top">0 … 500 µm</td>
<td valign="top">±(3 % + 1 µm)</td>
<td valign="top">Paint, lacquer, galvanic coating</td>
</tr>
<tr>
<td valign="top"><strong>Fe-2*</strong></td>
<td valign="top">0 … 2000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Paint, lacquer</td>
</tr>
<tr>
<td valign="top"><strong>Fe-5*</strong></td>
<td valign="top">0 … 5000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Lacquer and thick coating</td>
</tr>
<tr>
<td valign="top"><strong>NFe-2**</strong></td>
<td valign="top">0 … 2000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Anodic oxidelayer, lacquer layers</td>
</tr>
<tr>
<td valign="top"><strong>M12***</strong></td>
<td valign="top">0 … 12 mm / 0 … 0.47&#8243;</td>
<td valign="top">±(3 % + 0.01 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>M30***</strong></td>
<td valign="top">0 … 30 mm / 0 … 1.18&#8243;</td>
<td valign="top">±(3 % + 0.02 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>M60***</strong></td>
<td valign="top">0 … 60 mm / 0 … 2.36&#8243;</td>
<td valign="top">±(3 % + 0.03 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>DT</strong></td>
<td valign="top">-50 … 125°C / -58 … 257 °F</td>
<td valign="top">±1 °C</td>
<td valign="top">Surface temperature</td>
</tr>
<tr>
<td valign="top"><strong>DTVR</strong></td>
<td valign="top">Temperature: -50 … 125 °C / -58 … 257 °F</td>
<td valign="top">±1 °C</td>
<td valign="top">Air temperature</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Humidity</span>: 0 … 100 %</td>
<td valign="top">±5 %</td>
<td valign="top">Humidity</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Dew point</span>: -15 …+40 °C / 5 &#8230; 104 °F</td>
<td valign="top">±2 °C</td>
<td valign="top">Dew point</td>
</tr>
<tr>
<td valign="top"><strong>DSH</strong></td>
<td valign="top">1 … 300 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Roughness</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>* Fe:</strong> <span>only for ferromagnetic substrates</span></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>** NFe:</strong> <span>only for non-ferromagnetic substrates</span></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>*** Fe und NFe:</strong> <span>for ferromagnetic and non-ferromagnetic substrates</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90-ica-incl-iso-calibration-certificate/">Thickness Gauge PCE-CT 90-ICA Incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18442</post-id>	</item>
		<item>
		<title>Thickness Gauge PCE-CT 90</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:12:37 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18435</guid>

					<description><![CDATA[<p><strong>PCE-CT 90</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90/">Thickness Gauge PCE-CT 90</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Thickness gauge PCE-CT 90<br />
Coating thickness gauge with various sensors / Measuring range up to 60 mm /  Automatic sensor detection / Temperature, roughness, dew point, ambient humidity / Coating thickness measurement for Fe and NFe measurements / For mobile use </strong></div>
<div></div>
<div>The coating thickness gauge is a versatile measuring instrument. This is made possible by the various optional sensors on the layer thickness gauge. For example, the coating thickness gauge can easily measure the layer thicknesses of paints, galvanic coatings, galvanizing or even anodic oxide layers on metal. With the sensors, for example, layer thickness measurements with a thickness of up to 60 mm are possible.</div>
<div></div>
<div>In addition to the layer thickness sensors for the layer thickness gauge, there is also the climate sensor. With this climate sensor at the coating thickness gauge, the ambient temperature, the ambient humidity and the dew point can be measured. Also, in the film thickness gauge, there is the surface temperature sensor. Thanks to the surface temperature sensor, the surface temperature of an object in a measuring range of -50 &#8230; 125°C / -58 &#8230; 257°F can be determined with the Coating Thickness Gauge.</div>
<div></div>
<div>In addition, the roughness of surfaces can be determined with the layer thickness gauge. This is made possible by the optional roughness meter. With the roughness sensor from the layer thickness gauge, the Rz value of the surface can be determined within a very short time. The measuring range here is between 0 &#8230; 300 μm.</div>
<div></div>
<div>&#8211; Different sensors<br />
&#8211; Measuring range up to 60 mm<br />
&#8211; Automatic sensor detection<br />
&#8211; Zero point and one-point calibration<br />
&#8211; Power supply 2 x 1.5V AAA batteries<br />
&#8211; Temperature measurement up to 125°C / 257°F</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="2" valign="top">Measuring range</td>
<td colspan="2" valign="top">sensor-dependent (see sensor table)</td>
</tr>
<tr>
<td colspan="2" valign="top">Accuracy</td>
<td colspan="2" valign="top">sensor-dependent (see sensor table)</td>
</tr>
<tr>
<td colspan="2" valign="top">Measurable materials</td>
<td colspan="2" valign="top">magnetic materials (iron, steel &#8230;)<br />
non-magnetic materials<br />
(paints, plastics, ceramics, …)</td>
</tr>
<tr>
<td colspan="2" valign="top">Min. radius of curvature</td>
<td colspan="2" valign="top">0.3 … 50 mm / <span>0.012 &#8230; 1.97&#8243; </span>(<span>depending on the sensor used</span>)</td>
</tr>
<tr>
<td colspan="2" valign="top">Calibration</td>
<td colspan="2" valign="top">Zero calibration, one-point calibration</td>
</tr>
<tr>
<td colspan="2" valign="top">Units</td>
<td colspan="2" valign="top">µm, mm, °C</td>
</tr>
<tr>
<td colspan="2" valign="top">Power supply</td>
<td colspan="2" valign="top">2 x 1.5 V AAA batteries (DC)</td>
</tr>
<tr>
<td colspan="2" valign="top">Display</td>
<td colspan="2" valign="top">Graphic display</td>
</tr>
<tr>
<td colspan="2" valign="top">Operating conditions</td>
<td colspan="2" valign="top">-10 &#8230; 40 °C / 14 &#8230; 104 °F, 20 &#8230; 98% r. H., non-condensing at 35 °C / 95 °F</td>
</tr>
<tr>
<td colspan="2" valign="top">Storage conditions</td>
<td colspan="2" valign="top">5 &#8230; 40 °C / 41 &#8230; 104°F, 80% r. H., non-condensing at 25 °C / 77 °F</td>
</tr>
<tr>
<td colspan="2" valign="top">Dimensions</td>
<td colspan="2" valign="top">136 x 75 x 32 mm / 5.4 x 3 x 1.3&#8243;</td>
</tr>
<tr>
<td colspan="2" valign="top">Weight</td>
<td colspan="2" valign="top">168 g / &lt; 1 lb</td>
</tr>
<tr>
<td colspan="2" valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Sensor table</strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top" width="62"><strong>Model</strong></td>
<td valign="top" width="176"><strong><span>Measuring range</span></strong></td>
<td valign="top" width="168"><strong><span>Accuracy</span></strong></td>
<td valign="top" width="178"><strong><span>Measurement Description</span></strong></td>
</tr>
<tr>
<td valign="top"><strong>Fe-0.3*</strong></td>
<td valign="top">0 &#8230; 300 µm</td>
<td valign="top">±(3 % + 1 µm)</td>
<td valign="top">Paint, lacquer, galvanic coating</td>
</tr>
<tr>
<td valign="top"><strong>Fe-0.5*</strong></td>
<td valign="top">0 … 500 µm</td>
<td valign="top">±(3 % + 1 µm)</td>
<td valign="top">Paint, lacquer, galvanic coating</td>
</tr>
<tr>
<td valign="top"><strong>Fe-2*</strong></td>
<td valign="top">0 … 2000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Paint, lacquer</td>
</tr>
<tr>
<td valign="top"><strong>Fe-5*</strong></td>
<td valign="top">0 … 5000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Lacquer and thick coating</td>
</tr>
<tr>
<td valign="top"><strong>NFe-2**</strong></td>
<td valign="top">0 … 2000 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Anodic oxidelayer, lacquer layers</td>
</tr>
<tr>
<td valign="top"><strong>M12***</strong></td>
<td valign="top">0 … 12 mm / 0 … 0.47&#8243;</td>
<td valign="top">±(3 % + 0.01 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>M30***</strong></td>
<td valign="top">0 … 30 mm / 0 … 1.18&#8243;</td>
<td valign="top">±(3 % + 0.02 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>M60***</strong></td>
<td valign="top">0 … 60 mm / 0 … 2.36&#8243;</td>
<td valign="top">±(3 % + 0.03 mm)</td>
<td valign="top">Thick coating</td>
</tr>
<tr>
<td valign="top"><strong>DT</strong></td>
<td valign="top">-50 … 125°C / -58 … 257 °F</td>
<td valign="top">±1 °C</td>
<td valign="top">Surface temperature</td>
</tr>
<tr>
<td valign="top"><strong>DTVR</strong></td>
<td valign="top">Temperature: -50 … 125 °C / -58 … 257 °F</td>
<td valign="top">±1 °C</td>
<td valign="top">Air temperature</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Humidity</span>: 0 … 100 %</td>
<td valign="top">±5 %</td>
<td valign="top">Humidity</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Dew point</span>: -15 …+40 °C / 5 &#8230; 104 °F</td>
<td valign="top">±2 °C</td>
<td valign="top">Dew point</td>
</tr>
<tr>
<td valign="top"><strong>DSH</strong></td>
<td valign="top">1 … 300 µm</td>
<td valign="top">±(3 % + 2 µm)</td>
<td valign="top">Roughness</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>* Fe:</strong> <span>only for ferromagnetic substrates</span></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>** NFe:</strong> <span>only for non-ferromagnetic substrates</span></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>*** Fe und NFe:</strong> <span>for ferromagnetic and non-ferromagnetic substrates</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90/">Thickness Gauge PCE-CT 90</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-90/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18435</post-id>	</item>
		<item>
		<title>Thickness Gauge PCE-CT 100N-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:08:45 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18430</guid>

					<description><![CDATA[<p><strong>PCE-CT 100N-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n-ica-incl-iso-calibration-certificate/">Thickness Gauge PCE-CT 100N-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Thickness gauge</strong><strong> PCE-CT 100N-ICA incl. ISO Calibration Certificate<br />
Surface tester for ferrous and non-ferrous metals / Very compact size / Non-destructive, precise measurements / Data transmission via USB and Wifi / Simple operation / Uncomplicated and reliable</strong></div>
<div align="center"></div>
<div>The surface tester works according to the magnetic inductive (ISO 2178) and the eddy current method (ISO 2360). These methods supported by the surface tester are used for the non-destructive testing of materials. The surface tester is used to measure the thickness of magnetically neutral layers on a magnetic or non-magnetic base material.</div>
<div></div>
<div>The surface tester is ideal for reliable layer thickness measurements on site. With the external probe, the layer thickness can be measured quickly and easily, even in hard-to-reach places. The surface tester was developed for non-destructive, fast and precise layer thickness measurements and is easy to use. Measured data can be easily transferred to a PC using a USB data storage device or via WiFi.</div>
<div></div>
<div>The surface tester is used in particular in the finishing industry, electroplating, ship and bridge construction, aircraft construction and the machine and chemical industry.</div>
<div></div>
<div>&#8211; Illuminated touch keyboard<br />
&#8211; Measurement data storage for up to 500 data<br />
&#8211; One-point and multi-point calibration<br />
&#8211; Single measurement and continuous measurement<br />
&#8211; Data transfer via wifi and USB<br />
&#8211; Two different probes for NFe and Fe<br />
&#8211; incl. ISO Calibration Certificate</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">0 &#8230; 1250 µm; 0 &#8230; 49.2 mil</td>
</tr>
<tr>
<td valign="top">Min. coating thickness of base material</td>
<td valign="top">50 µm</td>
</tr>
<tr>
<td valign="top">Smallest measuring surface (diameter)</td>
<td valign="top">10 mm</td>
</tr>
<tr>
<td valign="top">Min. radius of curvature convex</td>
<td valign="top">15 mm</td>
</tr>
<tr>
<td valign="top">Min. radius of curvature concave</td>
<td valign="top">15 mm</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± (1% + 1 µm); ± (1% + 0.04 mil)</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 µm (&lt;99.9 µm); 0.004 mil (&lt;3.9 mil)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">1 µm (&gt; 100 µm); 0.04 mil (&gt; 3.9 mil)</td>
</tr>
<tr>
<td valign="top">Calibration</td>
<td valign="top">Single point, multiple point</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td valign="top">500 data</td>
</tr>
<tr>
<td valign="top">Measuring modes</td>
<td valign="top">Single measurements, continuous measurement</td>
</tr>
<tr>
<td valign="top">Interfaces</td>
<td valign="top"><strong>Wifi</strong> , USB</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">0 &#8230; 50°C / 32 &#8230; 122°F, 20 &#8230; 90% RH non-condensing</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">170 x 85 x 35 mm / 6.7 x 3.3 x 1.4 in</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">Approx. 335 g / &lt; 1 lb (with battery)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n-ica-incl-iso-calibration-certificate/">Thickness Gauge PCE-CT 100N-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18430</post-id>	</item>
		<item>
		<title>Thickness Gauge PCE-CT 100N</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:05:50 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18423</guid>

					<description><![CDATA[<div class="bestellnr"><strong>PCE-CT 100N</strong></div>
<div class="form-group prodcard_Preis"></div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n/">Thickness Gauge PCE-CT 100N</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Thickness gauge PCE-CT 100N</strong><br />
<strong>Surface tester for ferrous and non-ferrous metals / Very compact size / Non-destructive, precise measurements / Data transmission via USB and Wifi / Simple operation / Uncomplicated and reliable</strong></div>
<div></div>
<div>The surface tester works according to the magnetic inductive (ISO 2178) and the eddy current method (ISO 2360). These methods supported by the surface tester are used for the non-destructive testing of materials. The surface tester is used to measure the thickness of magnetically neutral layers on a magnetic or non-magnetic base material.</div>
<div></div>
<div>The surface tester is ideal for reliable layer thickness measurements on site. With the external probe, the layer thickness can be measured quickly and easily, even in hard-to-reach places. The surface tester was developed for non-destructive, fast and precise layer thickness measurements and is easy to use. Measured data can be easily transferred to a PC using a USB data storage device or via WiFi.</div>
<div></div>
<div>The surface tester is used in particular in the finishing industry, electroplating, ship and bridge construction, aircraft construction and the machine and chemical industry.</div>
<div></div>
<div>&#8211; Illuminated touch keyboard<br />
&#8211; Measurement data storage for up to 500 data<br />
&#8211; One-point and multi-point calibration<br />
&#8211; Single measurement and continuous measurement<br />
&#8211; Data transfer via wifi and USB<br />
&#8211; Two different probes for NFe and Fe</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="258"><span>Measuring range</span></td>
<td valign="top" width="320"><span>0 &#8230; 1250 µm; 0 &#8230; 49.2 mil</span></td>
</tr>
<tr>
<td valign="top">Min. coating thickness of base material</td>
<td valign="top">50 µm</td>
</tr>
<tr>
<td valign="top">Smallest measuring surface (diameter)</td>
<td valign="top">10 mm</td>
</tr>
<tr>
<td valign="top">Min. radius of curvature convex</td>
<td valign="top">15 mm</td>
</tr>
<tr>
<td valign="top">Min. radius of curvature concave</td>
<td valign="top">15 mm</td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td valign="top"><span>± (1% + 1 µm); ± (1% + 0.04 mil)</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.1 µm (&lt;99.9 µm); 0.004 mil (&lt;3.9 mil)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>1 µm (&gt; 100 µm); 0.04 mil (&gt; 3.9 mil)</span></td>
</tr>
<tr>
<td valign="top"><span>Calibration</span></td>
<td valign="top"><span>Single point, multiple point</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td valign="top"><span>500 data</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring modes</span></td>
<td valign="top"><span>Single measurements, continuous measurement</span></td>
</tr>
<tr>
<td valign="top"><span>Interfaces</span></td>
<td valign="top"><span>Wifi</span><span> , USB</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions          </span></td>
<td valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, 20 &#8230; 90% RH non-condensing</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td valign="top"><span>170 x 85 x 35 mm / 6.7 x 3.3 x 1.4 in</span></td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top"><span>Approx. 335 g / &lt; 1 lb (with battery)</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n/">Thickness Gauge PCE-CT 100N</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-ct-100n/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18423</post-id>	</item>
		<item>
		<title>Thickness Gauge PCE-TG 300</title>
		<link>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-tg-300/</link>
					<comments>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-tg-300/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 04:01:59 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=18415</guid>

					<description><![CDATA[<p><strong>PCE-TG 300</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-tg-300/">Thickness Gauge PCE-TG 300</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Thickness gauge PCE-TG 300<br />
Large measuring range / Up to 600 mm / Pulse-echo or echo-echo mode /  For all homogeneous materials / Print function via Bluetooth / USB connection</strong></div>
<div></div>
<div>The PCE-TG 300 is a wall thickness gauge with special sensors for various applications. In general, the wall thicknesses of all homogeneous materials can be measured with the PCE-TG 300. For damping or scattering materials such as plastic or cast a special sensor is available. An angled 90° sensor also enables measurements at hard-to-reach measuring points. The speed of sound can be set freely on the wall thickness gauge PCE-TG 300 and thus adapted to a wide variety of materials.</div>
<div></div>
<div>The measured values ​​are displayed directly on the easy-to-read TFT color display. Due to the internal memory, which can be read out via the optionally available software, different measuring points can be clearly stored. The non-destructive ultrasound measuring method enables the measurement even on end products. Thanks to the Echo-Echo working mode, even coated workpieces can be measured.</div>
<div></div>
<div>&#8211; Large measuring range<br />
&#8211; Various sensors available<br />
&#8211; Battery operation<br />
&#8211; Error and voids detection<br />
&#8211; Internal measurement data memory<br />
&#8211; Print via Bluetooth</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td>Measuring range</td>
<td colspan="2">PE: pulse-echo mode 0.65 &#8230; 600 mm (steel)</td>
</tr>
<tr>
<td></td>
<td colspan="2">EE: echo-echo mode 2.50 &#8230; 60 mm</td>
</tr>
<tr>
<td>Accuracy</td>
<td colspan="2">± 0.04 mm H [mm] (&lt;10 mm); ± 0.4% H [mm] (&gt; 10 mm)</td>
</tr>
<tr>
<td></td>
<td colspan="2">H refers to the material thickness of the workpiece</td>
</tr>
<tr>
<td>Resolution</td>
<td colspan="2">0.1 mm / 0.01 mm / 0.001 mm (adjustable)</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Measurable materials</td>
<td colspan="2">Metals</td>
</tr>
<tr>
<td></td>
<td colspan="2">Plastics</td>
</tr>
<tr>
<td></td>
<td colspan="2">Ceramics</td>
</tr>
<tr>
<td></td>
<td colspan="2">Epoxy resin</td>
</tr>
<tr>
<td></td>
<td colspan="2">Glass</td>
</tr>
<tr>
<td></td>
<td colspan="2">And all homogeneous materials</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Working modes</td>
<td colspan="2">Pulse echo mode (fault and blower detection)</td>
</tr>
<tr>
<td></td>
<td colspan="2">Echo-Echo mode (hiding layer thicknesses, eg paints)</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Calibration</td>
<td colspan="2">Sound velocity calibration</td>
</tr>
<tr>
<td></td>
<td colspan="2">Zeroing</td>
</tr>
<tr>
<td></td>
<td colspan="2">Two-point calibration</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td>View mode</td>
<td colspan="2">Normal mode, Scan mode, Difference mode</td>
</tr>
<tr>
<td>Units</td>
<td colspan="2">mm / inch</td>
</tr>
<tr>
<td>Data transfer</td>
<td colspan="2">Print via Bluetooth / USB 2.0</td>
</tr>
<tr>
<td>Storage</td>
<td colspan="2">Non-volatile memory with 100 data groups with 100 data sets each</td>
</tr>
<tr>
<td>Operating time</td>
<td colspan="2">Continuous operation 100 h</td>
</tr>
<tr>
<td></td>
<td colspan="2">Automatic stand-by mode (adjustable)</td>
</tr>
<tr>
<td></td>
<td colspan="2">Automatic switch-off mode (adjustable)</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Power supply</td>
<td colspan="2">4 x AA battery 1.5V</td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">320 x 240 pixels TFT LCD color display with brightness adjustment</td>
</tr>
<tr>
<td>Operating conditions</td>
<td colspan="2">0 &#8230; 50°C / 32 &#8230; 122°F, ≤ 80% RH not condensing</td>
</tr>
<tr>
<td>Storage conditions</td>
<td colspan="2">-20 &#8230; 70°C / -4 &#8230; 158°F, ≤ 80% rh non-condensing</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="2">185 x 97 x 40 mm / 7.3 x 3.8 x 1.6 in</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">375 g / &lt; 1 lb</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="3"><strong>Specification of the available sensors for wall thickness gauge PCE-TG 300</strong></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>NO2</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">2.5 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">14 mm</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">3 &#8230; 40 mm (steel)</td>
</tr>
<tr>
<td></td>
<td colspan="2">3 &#8230; 300 mm (steel)</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">Not suitable for curved materials</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">For damping / scattering materials (plastics, cast iron)</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>NO5</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">5 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">10 mm</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">1 &#8230; 600 mm (steel)</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">20 x 3 mm</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">Normal measurement</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>NO5 / 90°</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">5 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">10</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">1 &#8230; 600 mm (steel)</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">20 x 3 mm</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">Normal measurement</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>NO7</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">7 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">6 mm</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">0.65 &#8230; 200 mm (steel)</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">15 x 2 mm</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">Or thin-walled or heavily curved pipes</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>HT5</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">5 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">12 mm</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">1 &#8230; 600 mm (steel)</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">30 mm</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">For high temperatures (max 300°C / 572°F)</td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
</tr>
<tr>
<td><strong>P5EE</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Frequency</td>
<td colspan="2">5 MHz</td>
</tr>
<tr>
<td>Diameter</td>
<td colspan="2">10 mm</td>
</tr>
<tr>
<td>Measuring range</td>
<td colspan="2">PE: 2 &#8230; 600 mm, EE: 2.5 &#8230; 100 mm</td>
</tr>
<tr>
<td>Minimum diameter of pipes</td>
<td colspan="2">20 x 3 mm</td>
</tr>
<tr>
<td>Description</td>
<td colspan="2">Normal measurement and EE test</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-tg-300/">Thickness Gauge PCE-TG 300</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/thickness-gauge/thickness-gauge-pce-tg-300/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">18415</post-id>	</item>
	</channel>
</rss>
