<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Ultrasonic Tester / Ultrasonic Testing - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/ultrasonic-tester-ultrasonic-testing/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/ultrasonic-tester-ultrasonic-testing/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Fri, 18 Nov 2022 04:44:02 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Ultrasonic Tester / Ultrasonic Testing - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/ultrasonic-tester-ultrasonic-testing/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Ultrasonic / UCI Hardness Tester PCE-5000</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-5000/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-5000/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 06 May 2021 02:49:56 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19390</guid>

					<description><![CDATA[<p><strong>PCE-5000</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-5000/">Ultrasonic / UCI Hardness Tester PCE-5000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>PCE-5000 Ultrasonic / UCI Hardness Tester Uses the ASTM A1038 ultrasonic contact impedance (UCI) method for metal and alloy hardness testing</strong></div>
<div></div>
<div>PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Ultrasonic hardness testing is considered nondestructive, as it creates a microscopic indentation only visible when using a high-powered microscope.</div>
<div></div>
<div>Featuring a quick 2-second measurement time, this UCI hardness tester is the ideal tool for weld inspection, hardness control of metal coatings and hardness measurement of fine-grained metals, small forgings, cast materials, heat-affected zones, ion-nitrided stamping dies and molds, forms, presses, thin-walled structures and parts, bearings, tooth flanks, pipes, tanks, steel sheets and products with intricate or complex shapes.</div>
<div></div>
<div>Additional measuring sensors can be connected to the ultrasonic meter, which vary in their test force, which is applied to measure the hardness. The different sensors measure the hardness of the objects depending on the roughness of their surface. For example, the standard sensor with 20 N measures surfaces with a roughness of less than 5 µm. The 10 N sensor measures a roughness of less than 3.2 µm and the one with 98 N measures a roughness of less than 15 µm.</div>
<div></div>
<div>&#8211; Measures the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in<br />
&#8211; Displays measurements in Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units<br />
&#8211; Measuring range: 61 … 85.6 HRA, 41 … 100 HRB, 20.3 … 68 HRC, 85 … 650 HB, 50 … 999 HV, 255 … 2180 MPa (N/mm²)<br />
&#8211; Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV<br />
&#8211; Stores up to 2000 measurement groups / 20 calibration sets to memory<br />
&#8211; Provides measurements in just 2 seconds<br />
&#8211; Probe fits into small spaces and hard-to-reach places<br />
&#8211; Features a large and easy-to-read LCD screen, simple calibration and an RS-232 interface</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Measuring range</strong></td>
</tr>
<tr>
<td>Rockwell A B C</td>
<td>61 … 85.6 HRA, 41 … 100 HRB, 20.3 … 68 HRC</td>
</tr>
<tr>
<td>Brinell</td>
<td>85 … 650 HB</td>
</tr>
<tr>
<td>Vickers</td>
<td>50 … 999 HV</td>
</tr>
<tr>
<td>Tensile strength</td>
<td>255 … 2180 N/mm²</td>
</tr>
<tr>
<td colspan="2"><strong>Accuracy</strong></td>
</tr>
<tr>
<td>Rockwell</td>
<td>± 1.5 HR</td>
</tr>
<tr>
<td>Brinell</td>
<td>± 3% HB</td>
</tr>
<tr>
<td>Vickers</td>
<td>± 3% HV</td>
</tr>
<tr>
<td colspan="2"><strong>General specifications</strong></td>
</tr>
<tr>
<td>Measurement method</td>
<td>Ultrasonic contact impedance (UCI) per ASTM A1038</td>
</tr>
<tr>
<td>Direction of measurement</td>
<td>360°</td>
</tr>
<tr>
<td>Measurement time</td>
<td>2 seconds</td>
</tr>
<tr>
<td>Hardness units</td>
<td>HRA, HRB, HRC, HB, HV, MPa</td>
</tr>
<tr>
<td>Display</td>
<td>LCD with backlight</td>
</tr>
<tr>
<td>Minimum material thickness</td>
<td>2 mm</td>
</tr>
<tr>
<td>Data memory</td>
<td>Up to 2000 measurement groups<br />
Up to 20 calibration sets</td>
</tr>
<tr>
<td>Measurement probe</td>
<td>20 N (standard)</td>
</tr>
<tr>
<td>Probe cable length</td>
<td>1.5 m / .06 in</td>
</tr>
<tr>
<td>Functions</td>
<td>Single value, min / max, average value</td>
</tr>
<tr>
<td>Power supply</td>
<td>4.2V rechargeable battery, 4800-mAh</td>
</tr>
<tr>
<td>Battery life</td>
<td>Approx. 10 hrs of operation at full charge (without backlight)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>162 x 81 x 31 mm / 6.38 x 3.19 x 1.22 in</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>-10 &#8230; 40°C / 14 &#8230; 104°F, ≤ 85% RH</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60°C / -4 &#8230; 140°F, ≤ 85% RH</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 755 g / 1.67 lb (including probe)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-5000/">Ultrasonic / UCI Hardness Tester PCE-5000</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-5000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19390</post-id>	</item>
		<item>
		<title>Ultrasonic Thickness Tester PCE-USC 20</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-usc-20/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-usc-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 06 May 2021 02:43:59 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19384</guid>

					<description><![CDATA[<p><strong>PCE-USC 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-usc-20/">Ultrasonic Thickness Tester PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-USC 20 is a portable or benchtop ultrasonic thickness tester or ultrasonic thickness gauge with a 5.7&#8243; TFT color LCD screen. This ultrasound-based thickness meter uses one or two contact transducers (four different probes included; 90 °, 70 °, 60 °, 45 °) to measure material or wall thickness, detect flaws or defects in welds, and monitor the effects of corrosion on pipes and tanks.</p>
<p>PCE-USC 20 is an ultrasonic thickness gauge used for non-destructive testing (NDT) and inspection in a wide variety of applications in industries such as chemical, oil and gas, metallurgical, manufacturing, quality control, metalworking, welding, machining, engineering, product research and development, construction, transportation and aerospace.</p>
<p>&#8211; Measurement range: 0.5 &#8230; 9999 mm (steel; longitudinal wave)<br />
&#8211; Operating frequency range: 0.5 &#8230; 20 MHz<br />
&#8211; Sound velocity: 1000 &#8230; 15000 m/s (continuously adjustable)<br />
&#8211; AVG and DAC evaluation methods, display and probes delay, damping and reinforcing functions, export and reporting functions<br />
&#8211; Saves up to 500 records to memory<br />
&#8211; Lightweight design for ease of portability<br />
&#8211; Complies with EN12668-1</p>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="250" height="1">Measurement range</td>
<td valign="top" width="347" height="1">0.5 &#8230; 9999 mm (longitudinal shaft steel), continuously adjustable</td>
</tr>
<tr>
<td valign="top" width="250" height="24">Sound velocity</td>
<td valign="top" width="347" height="24">1000 &#8230; 15000 m/s, continuously adjustable, coarse adjustment</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display delay</td>
<td valign="top" width="347" height="21">-10 &#8230; 2000 mm</td>
</tr>
<tr>
<td valign="top" width="250" height="2">Probe delay</td>
<td valign="top" width="347" height="2">0.00 &#8230; 199.9 µs</td>
</tr>
<tr>
<td valign="top" width="250" height="1">Transmitting impulse</td>
<td valign="top" width="347" height="1">400 V negative signal peaks</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Damping (impulse generator)</td>
<td valign="top" width="347" height="21">50 / 100 / 200 / 500</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Work mode</td>
<td valign="top" width="347" height="21">One- or two-probe measurement</td>
</tr>
<tr>
<td valign="top" width="250" height="11">Operating frequency range</td>
<td valign="top" width="347" height="11">0.5 &#8230; 20 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="5">Pulse repetition frequency</td>
<td valign="top" width="347" height="5">40 / 250 /1000 Hz optional</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Amplification / gain (receiver)</td>
<td valign="top" width="347" height="21">0 &#8230; 110 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Rectification (receiver)</td>
<td valign="top" width="347" height="21">Whole wave, positive half wave, negative half wave, high frequency representation</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Alarm limits</td>
<td valign="top" width="347" height="3">Limit A (Gate A) and Limit B (Gate B),<br />
Adjustable as positive or negative peak with automatic (visual or audible) alarm</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement mode</td>
<td valign="top" width="347" height="3">Limit value  / Extreme value mode</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation horizontal linearity</td>
<td valign="top" width="347" height="3">≤0.1 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Measurement deviation vertical linearity</td>
<td valign="top" width="347" height="3">≤3 %</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Excess sensitivity</td>
<td valign="top" width="347" height="3">≥62 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Dynamic range</td>
<td valign="top" width="347" height="3">≥40 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Resolution remote field</td>
<td valign="top" width="347" height="21">≥30 dB</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Sampling rate</td>
<td valign="top" width="347" height="21">400 MHz</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Measurement data storage</td>
<td valign="top" width="347" height="21">500 records</td>
</tr>
<tr>
<td valign="top" width="250" height="7">Signal reproduction</td>
<td valign="top" width="347" height="7">Permanent recording of signals with the playback of dynamic echoes</td>
</tr>
<tr>
<td valign="top" width="250" height="4">Surface adjustment</td>
<td valign="top" width="347" height="4">Automatic adjustment of the error position of the angled probes</td>
</tr>
<tr>
<td valign="top" width="250" height="3">Automatic amplification</td>
<td valign="top" width="347" height="3">20 &#8230; 80 %, in 1 % steps</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Menu language</td>
<td valign="top" width="347" height="21">English, Chinese</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Interface</td>
<td valign="top" width="347" height="21">USB-A, USB-B, Ethernet</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Display</td>
<td valign="top" width="347" height="21">5.7 &#8221; TFT color LCD (640 x 480 pixels)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Operating temperature</td>
<td valign="top" width="347" height="21">-10 &#8230; +50 °C</td>
</tr>
<tr>
<td valign="top" width="250" height="40">Power supply</td>
<td valign="top" width="347" height="40">AC: 100 &#8230; 240 V<br />
DC: 15 V / 4 A</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery</td>
<td valign="top" width="347" height="21">Li-ion battery (10.8 V, 5200 mAh)</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Battery opearting time per charge</td>
<td valign="top" width="347" height="21">&gt;6 hours</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Protection class</td>
<td valign="top" width="347" height="21">IP54</td>
</tr>
<tr>
<td valign="top" width="250" height="21">Weight</td>
<td valign="top" width="347" height="21">1.4 kg (incl. battery)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-usc-20/">Ultrasonic Thickness Tester PCE-USC 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-usc-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19384</post-id>	</item>
		<item>
		<title>Ultrasonic Thickness Tester PCE-FD 20</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-fd-20/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-fd-20/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Thu, 06 May 2021 02:40:48 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19373</guid>

					<description><![CDATA[<p><strong>PCE-FD 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-fd-20/">Ultrasonic Thickness Tester PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-FD 20 is a portable ultrasonic thickness tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan images of cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.<br />
&#8211; Operating frequency range: 1 &#8230; 10 MHz<br />
&#8211; Measured time interval range: 6 &#8230; 1000 microseconds (µs)<br />
&#8211; Sound velocity: 1000 &#8230; 9999 m/s<br />
&#8211; Implements shadow, echo and mirror-shadow testing methods<br />
&#8211; Features a USB interface for downloading data to PC for detailed analysis<br />
&#8211; Lightweight<br />
&#8211; Battery or electric power<br />
&#8211; 1.5 m long probe cable</p>
<table border="0" width="100%" cellspacing="1" cellpadding="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td><strong>Technical specifications</strong></td>
</tr>
</tbody>
</table>
<table class="tech" border="0">
<tbody>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measure time interval range (scan duration)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">6 &#8230; 1000 microseconds (µs)</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Sound velocity range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">1000 &#8230; 9999 m/s</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of measurement of time intervals</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.025 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Max. deviation of amplitude of signals at receiver input in 0 &#8230; 110 dB range</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Not exceed ± 0.5 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Testing gain region</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">125 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Averaging over the quantity of starts</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 16</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Range of time-variable gain (TVG) / Number of control points TVG</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">40 dB / 15</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Duration of excitation pulse to load</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 0.5 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Amplitude of excitation pulse to 50 Ohm load, not less</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">100, 200, 300</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Operating frequency range of receiver at -3 dB</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 10 MHz</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Deviation of amplitudes of input signals in 10 &#8230; 100% range of screen height</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Not more than 1 dB</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">1 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Scanning delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Measurement range of time intervals</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 1000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Prism of probe delay</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 15 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Automatic signaling of defects (AFS)</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dual-gate</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Setting range of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 2000 µs</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Adjusting thresholds of AFS gates</p>
</td>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">0 &#8230; 100%</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Detection of signals (receiver)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">Positive half-wave, radio mode</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions of device (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">80 x 162 x 35 mm / 3.14 x 6.37 x 1.37&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Dimensions display (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">48 x 74 mm / 1.88 x 2.91&#8243;</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Power supply</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">100 &#8230; 250 V AC or 3 x 1.5 V AA batteries</p>
</td>
</tr>
<tr>
<td class="tech" valign="top" width="50%" height="18">
<p align="left">Weight (approx.)</p>
</td>
<td class="tech" align="center" valign="top" width="50%" height="18">
<p align="left">250 g / 0.55 lb (without batteries)</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-fd-20/">Ultrasonic Thickness Tester PCE-FD 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-thickness-tester-pce-fd-20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19373</post-id>	</item>
		<item>
		<title>Ultrasonic Flow Tester PCE-TDS 100HSH+-ICA incl. Thermometer and ISO Cal. Certs.</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hsh-ica-incl-thermometer-and-iso-cal-certs/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hsh-ica-incl-thermometer-and-iso-cal-certs/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:53:07 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19056</guid>

					<description><![CDATA[<p><strong>PCE-TDS 100HSH+-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hsh-ica-incl-thermometer-and-iso-cal-certs/">Ultrasonic Flow Tester PCE-TDS 100HSH+-ICA incl. Thermometer and ISO Cal. Certs.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="center"><strong>Ultrasonic flow </strong><strong>tester PCE-TDS 100HSH+-ICA incl. Temperature data logger &amp; ISO Calibration Certificates<br />
according to the transit time difference method / For determining flow velocity and flow / Measurement method for liquids that are as homogeneous as possible</strong></p>
<div>This is a portable handheld clamp-on ultrasonic flow tester used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 &#8230; 4&#8243; and 57 … 720 mm / approx. 2 &#8230; 28&#8243;. Ideal for use in oil and gas, water and wastewater, chemical, food and beverage, pharmaceutical, metals and mining, pulp and paper, power and heating, ventilation, air conditioning and refrigeration (HVACR) industries, this ultrasonic flow meter features user-friendly velcro-strap clamps that allow for quick and easy repositioning of the electroacoustic transducers.</div>
<div></div>
<div>Measurable liquids include: acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R 12, petrol, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, engine oil, diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1, 1, 1 &#8211; trichloroethane, turpentine, distilled water and sea water.</div>
<p>Calculation of flow velocity according to the transit-time principle follows the equation:</p>
<p align="center"><img decoding="async" src="http://www.industrial-needs.com/technical-data/images/ultrasonic-flow-meter-pce-tds-100h-calculation.jpg" width="190" height="45" border="0" /></p>
<p align="center">v = measured velocity<br />
T1 = run time of the ultrasonic signal in the flow direction<br />
T2 = run time of the ultrasonic signal against the flow direction<br />
L = length of the ultrasonic wave<br />
α = ultrasonic signal angle to the flow</p>
<p><strong>The transit-time principle requires pipes to be full and have no bubbles and no particles.</strong></p>
<p>Each meter is assembled and calibrated by PCE Instruments in Germany. Therefore, a factory calibration certificate is provided by PCE Germany in the delivery contents of the meter. The certificate includes one measuring point on two different pipes. The reference display of the in-house test stand used by PCE for calibration has a valid DAkkS calibration certificate. This ensures traceability to the Physikalisch-Technische Bundesanstal (PTB) German national standard. Please note that because the meter&#8217;s measured values depend upon the pipe geometry, material and coating; the medium type, temperature and speed; and the sensor type and measuring method, these parameters are listed on the supplied certificate for maximum traceability.<br />
&#8211; ideal for retrofitting<br />
&#8211; installation without process interruption<br />
&#8211; easy assembly<br />
&#8211; accurate and reliable<br />
&#8211; no pressure loss<br />
&#8211; maintenance-free, no moving parts<br />
&#8211; wear-free<br />
&#8211; portable devices for control measurements<br />
&#8211; <strong>incl. ISO calibration certificates</strong></p>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="2" valign="top"><strong>Technical Data Ultrasonic Flow Tester PCE-TDS 100</strong></td>
</tr>
<tr>
<td valign="top">Handheld measuring range</td>
<td valign="top">-32 &#8230; +32 m/s</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.0001 m/s</td>
</tr>
<tr>
<td valign="top">Accuracy for DN ≥ 50 mm:<br />
for DN &lt; 50 mm:</td>
<td valign="top">±1.5 % of measured value<br />
±3.5 % of measured value</td>
</tr>
<tr>
<td valign="top">Reproducibility</td>
<td valign="top">±1.0 % of measured value</td>
</tr>
<tr>
<td valign="top">Media</td>
<td valign="top">All liquids with an impurity</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">&lt;5% and a flow &gt;0.03 m³/h</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Flow units</strong></td>
<td valign="top">Cubic meter [m³]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Liter [l]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Gallon (USA) [gal]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Imperial gallon (UK) [igl]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Million USA gallon [mgl]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Cubic foot [cf]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Barrel (USA) [bal]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Imperial barrel (UK) [ib]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Oil barrel [ob]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Time settings</strong></td>
<td valign="top">per day [/d]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">per hour [/h]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">per minute  [/m]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">and per second [/s]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Data logger</td>
<td valign="top">1800 measurements</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">USB (for online measurement and reading of the internal memory)</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">IP 52</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x AA NiMH rechargeable battery / 2100 mAh</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(at full charge 12h running time) 100 … 240 V AC 50/60 Hz</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">214 x 104 x 40 mm / 8.4 x 4.1 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">450 g / 15 oz</td>
</tr>
<tr>
<td valign="top">Sensor</td>
<td valign="top"><strong>nominal width DN 15 … 100, 20 … 108 mm / approx. 3/4 &#8230; 4&#8243;</strong></p>
<p><strong>nominal width DN 50 … 700, 57 … 720 mm / approx. 2 &#8230; 28&#8243;</strong></td>
</tr>
<tr>
<td valign="top">Temperature of liquid</td>
<td valign="top">-30 … 160 °C / -22 &#8230; 320 °F</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">50 x 45 x 45 mm / 1.9 x 1.7 x 1.7&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">260 g / 9oz</td>
</tr>
<tr>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Technical data evaluation software</strong></td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Units of power W, kW, MW, J/h, kJ/h, MJ/h, Btu/h, kBtu/h, MBtu/h</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; <span class="tlid-translation translation" lang="en">Units of energy</span> J, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Graphical representation of flow, flow temperature,</td>
</tr>
<tr>
<td colspan="2" valign="top">  return temperature, heat output and heat quantity</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Tabular representation of flow, flow temperature,</td>
</tr>
<tr>
<td colspan="2" valign="top">  return temperature, heat output and heat quantity</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Mobile and stationary measurement mode</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Real-time data logger with unlimited runtime (only limited by PC memory capacity)</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Data export function</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; User-guided software operation with step-by-step instructions for</td>
</tr>
<tr>
<td colspan="2" valign="top">  device and software configuration</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Technical Data Temperature Datalogger PCE-T 330</strong></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type K  </strong></td>
<td valign="top">-200 … +1370 °C / -328 &#8230; 2498 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type T</strong></td>
<td valign="top">&#8211;200 … +400 °C / -328 &#8230; 752 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">00.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type J</strong></td>
<td valign="top">&#8211;200 … +1200 °C /  -328 &#8230; 2192 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">00.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring rate</td>
<td valign="top">2/s</td>
</tr>
<tr>
<td valign="top">Operating temperature</td>
<td valign="top">-10 … +50 °C / 14 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top">Storage temperature</td>
<td valign="top">-20 … +60 °C (without batteries) / -4 &#8230; 140 °F</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x AAA batteries / 1.2 V battery</td>
</tr>
<tr>
<td valign="top">Battery life</td>
<td valign="top">ca. 190 h</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(without backlight, battery capacity 1200 mAh,</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">ambient temperature 25 °C)</td>
</tr>
<tr>
<td valign="top">Protection class</td>
<td valign="top">IP52 (with protective cover and connected sensor)</td>
</tr>
<tr>
<td valign="top">Norm/ certification</td>
<td valign="top">CE/EMC ROHS</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hsh-ica-incl-thermometer-and-iso-cal-certs/">Ultrasonic Flow Tester PCE-TDS 100HSH+-ICA incl. Thermometer and ISO Cal. Certs.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hsh-ica-incl-thermometer-and-iso-cal-certs/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19056</post-id>	</item>
		<item>
		<title>Ultrasonic / UCI Hardness Tester PCE-3000UL</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3000ul/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3000ul/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:51:07 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19043</guid>

					<description><![CDATA[<p><strong>PCE-3000UL</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3000ul/">Ultrasonic / UCI Hardness Tester PCE-3000UL</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center"><strong>UCI hardness tester PCE-3000 series </strong><strong>Mobile UCI hardness tester / hardness scales HRC, HB and HV / NDT device </strong><strong>for measuring tensile strength Rm suitable / / for parts up to a thickness of 1 mm</strong></p>
<p>The UCI hardness tester PCE-3000 can be used for quickly checking the hardness of components even after installation. The device offers a wide measurement range, easy handling, robust design and a temperature resistance up to -20 ° C. In addition to the hardness in Rockwell, Brinell and Vickers, the UCI hardness tester can test the tensile strength of steels up to 1740 MPa. The UCI hardness tester comes standard with a manual probe with a test force of 50N, with this probe can be measured independent of direction from all directions with no correction factor.</p>
<p>Another advantage of the hardness tester is its NDT property. There is a Vickers diamond, which is excited in the ultrasonic frequency range at the probe tip. Touching the diamond to the specimen surface dampens the vibrations. The resulting frequency shift is directly related to the surface hardness of the test piece. Due to the low test loads, the penetration depth of the diamond is very low, which is why only an almost invisible impression remains.</p>
<p>The UCI hardness tester is therefore used for the control of small thin-walled components, for surface hardened specimens or nitrided components. The hardness tester has also been effective in the measurement of welds and control of components with complex geometry.</p>
<p>In addition to the UCI method measuring the PCE-3000 can be equipped with a rebound probe. This allows the UCI hardness tester can be upgraded to a Rebound hardness testers. So the users of hardness tester are two models to choose from the PCE-3000U with UCI Hardness Tester and the PCE-3000UL, which is complemented by the rebound hardness probe.</p>
<p>&#8211; Non-destructive hardness testing<br />
&#8211; different hardness scales<br />
&#8211; 5 materials testable</p>
<p>&#8211; Battery operation<br />
&#8211; USB interface<br />
&#8211; different measuring probes can be connected</p>
<table>
<tbody>
<tr>
<td colspan="2" align="left" valign="top" width="600"><strong>Technical specification for UCI hardness tester PCE-3000</strong></td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Measuring Range</td>
<td align="left" valign="top" width="300">Rockwell 20 &#8230; 70 HRC<br />
Brinell 90 &#8230; 450 HB<br />
Vickers 230 &#8230; 940 HV<br />
tensile strength 370 &#8230; 1740 MPa</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Measurement Accuracy</td>
<td align="left" valign="top" width="300">± 1.5% HRC<br />
± 3% HB<br />
± 3% HV</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Maximum Materialrauhigkeit</td>
<td align="left" valign="top" width="300">10 N probe: 1.5 Ra<br />
50 N probe: 2.5 Ra<br />
rebound probe: 3,2 Ra</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Maximum Curvature Radius of the Surface</td>
<td align="left" valign="top" width="300">UCI probes: 5.0mm / 0.19 in<br />
rebound probe: 10 mm / 0.39 in</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Minimum Weight of the Specimen</td>
<td align="left" valign="top" width="300">UCI probes: 0.1 Kg / 0.2 lbs<br />
rebound probe: 5 kg / 11 lbs</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Minimum thickness of the test specimen</td>
<td align="left" valign="top" width="300">UCI probes: 1 mm / 0.03 in<br />
rebound probe: 10 mm / 0.3 in</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Working Conditions</td>
<td align="left" valign="top" width="300">&#8211; 20 &#8230; 40 ° C / -4 &#8230; 104 ° F</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300" height="21">Dimensions</td>
<td align="left" valign="top" width="300">Unit: 122 x 65 x 33 mm / 4.8 x 2.5 x 1.2 in<br />
UCI probe: Ø25 x 140 mm / 0.9 x 5.5 in<br />
rebound probe: Ø20 x 150 mm / 0.7 x 5.9 in</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300" height="6">Weight</td>
<td align="left" valign="top" width="300" height="6">Device: 200g / 7.05 oz<br />
UCI probe: 250 g / 8.8 oz<br />
rebound probe: 100 g / 3.5 oz</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300">Power Supply</td>
<td align="left" valign="top" width="300">2 x 1.5 V battery</td>
</tr>
<tr>
<td></td>
</tr>
<tr>
<td align="left" valign="top" width="300" height="5">Battery Life</td>
<td align="left" valign="top" width="300" height="5">20 h</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3000ul/">Ultrasonic / UCI Hardness Tester PCE-3000UL</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3000ul/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19043</post-id>	</item>
		<item>
		<title>Ultrasonic / UCI Hardness Tester PCE-3500-98</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-98/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-98/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:36:41 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19036</guid>

					<description><![CDATA[<p><strong>PCE-3500-98</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-98/">Ultrasonic / UCI Hardness Tester PCE-3500-98</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>UCI hardness tester PCE-3500 for non-destructive hardness measurement / large<br />
colour LC display / including software / HV, HRC, HRB, HB and MPa scale /with memory function / probes interchangeable / 136 ° Vickers diamond</strong></div>
<div>
<p align="justify">The UCI hardness tester PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. The UCI hardness tester works on the basis of the Ultrasonic Contact Impedance test procedure. This UCI procedure works as follows: a Vickers diamond at the probe is stimulated with its self-resonance. By pushing the probe, the vibration frequency is reduced depending on the hardness of the surface and on the e module of the material and of the contact surface. The hardness of the surface can be determined on the basis of the frequency shift, taking the characteristic curve of the material into consideration.</p>
<p align="justify">The UCI hardness tester works non-destructively. There is a microscopically slight pressure against the surface, however, this is normally not visible. Due to the low penetration depth of the Vickers diamond, this UCI hardness tester is especially suitable for edge layer hardened components such as, for example, those that emerge when nitriding or induction hardening. It is typically used for punching tools, presses, thin-walled components, cog wheels, turbine blades, camshafts or weld seams. The UCI hardness tester is also suitable for many other hardness testing applications. It has exchangeable probes with different pressure forces and can therefore cover diverse applications.</p>
<p align="justify">After measuring the hardness of a component, the UCI hardness tester PCE-3500 shows different statistical values such as the MAX / MIN values and average values. Moreover, the standard deviation and further coefficients can be determined. A bar chart can be indicated. Since the UCI hardness tester is equipped with an internal memory, the measured data can be evaluated by means of a software.</p>
</div>
<div>
<div>&#8211; measurement in line with UCI procedure<br />
&#8211; tests HRC, HRB, HV, HB, MPa<br />
&#8211; measurement direction 360 °<br />
&#8211; large colour LC display</div>
<div>&#8211; memory function via SD card<br />
&#8211; different probes can be attached<br />
&#8211; characteristic curve of material pre-calibrated<br />
&#8211; evaluation via software possible</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Technical specifications on the UCI hardness tester PCE-3500</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td colspan="2">230 &#8230; 940 HV<br />
20 &#8230; 70 HRC<br />
90 &#8230; 650 HB<br />
370 &#8230; 1740 MPa</td>
</tr>
<tr>
<td>Accuracy</td>
<td colspan="2">+/- 3 % HV<br />
+/- 1,5 HRC<br />
+/- 3 % HB</td>
</tr>
<tr>
<td>Probes</td>
<td colspan="2">50 N UCI probe (10 N UCI probe optional)</td>
</tr>
<tr>
<td>Hardness scales</td>
<td colspan="2">HRC, HB, HV, HRB, HL, MPA</td>
</tr>
<tr>
<td>Materials</td>
<td colspan="2">UCI: steel (ferromagnetic)</td>
</tr>
<tr>
<td>Reference block</td>
<td colspan="2">136 ° Vickers diamond</td>
</tr>
<tr>
<td>Measurement direction</td>
<td colspan="2">360 °</td>
</tr>
<tr>
<td>Minimum material thickness</td>
<td colspan="2">1 mm (with UCI probe only)</td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">graphical colour LCD with backlight</td>
</tr>
<tr>
<td>Functions</td>
<td colspan="2">Single measurement, MIN / MAX / average value, number of measurements, mean value, standard deviation, variation coefficient, bar chart, Smart Mode (filters outliers)</td>
</tr>
<tr>
<td>Memory</td>
<td colspan="2">SD card</td>
</tr>
<tr>
<td>Interface</td>
<td colspan="2">USB</td>
</tr>
<tr>
<td>Operating conditions</td>
<td colspan="2">-20 &#8230; +40 °C; 30 &#8230; 80 % RH</td>
</tr>
<tr>
<td>Power supply</td>
<td colspan="2">6 V (3 x AA batteries)</td>
</tr>
<tr>
<td>Battery life</td>
<td colspan="2">approx. 10 hours</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="2">160 x 75 x 30 mm</td>
</tr>
<tr>
<td>Protection class</td>
<td colspan="2">IP 54</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">300 g (without probe)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-98/">Ultrasonic / UCI Hardness Tester PCE-3500-98</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-98/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19036</post-id>	</item>
		<item>
		<title>Ultrasonic / UCI Hardness Tester PCE-3500-10</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-10/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:35:58 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19031</guid>

					<description><![CDATA[<p><strong>PCE-3500-10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-10/">Ultrasonic / UCI Hardness Tester PCE-3500-10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>UCI hardness tester PCE-3500 for non-destructive hardness measurement / large<br />
colour LC display / including software / HV, HRC, HRB, HB and MPa scale /with memory function / probes interchangeable / 136 ° Vickers diamond</strong></div>
<div>
<p align="justify">The UCI hardness tester PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. The UCI hardness tester works on the basis of the Ultrasonic Contact Impedance test procedure. This UCI procedure works as follows: a Vickers diamond at the probe is stimulated with its self-resonance. By pushing the probe, the vibration frequency is reduced depending on the hardness of the surface and on the e module of the material and of the contact surface. The hardness of the surface can be determined on the basis of the frequency shift, taking the characteristic curve of the material into consideration.</p>
<p align="justify">The UCI hardness tester works non-destructively. There is a microscopically slight pressure against the surface, however, this is normally not visible. Due to the low penetration depth of the Vickers diamond, this UCI hardness tester is especially suitable for edge layer hardened components such as, for example, those that emerge when nitriding or induction hardening. It is typically used for punching tools, presses, thin-walled components, cog wheels, turbine blades, camshafts or weld seams. The UCI hardness tester is also suitable for many other hardness testing applications. It has exchangeable probes with different pressure forces and can therefore cover diverse applications.</p>
<p align="justify">After measuring the hardness of a component, the UCI hardness tester PCE-3500 shows different statistical values such as the MAX / MIN values and average values. Moreover, the standard deviation and further coefficients can be determined. A bar chart can be indicated. Since the UCI hardness tester is equipped with an internal memory, the measured data can be evaluated by means of a software.</p>
</div>
<div>
<div>&#8211; measurement in line with UCI procedure<br />
&#8211; tests HRC, HRB, HV, HB, MPa<br />
&#8211; measurement direction 360 °<br />
&#8211; large colour LC display</div>
<div>&#8211; memory function via SD card<br />
&#8211; different probes can be attached<br />
&#8211; characteristic curve of material pre-calibrated<br />
&#8211; evaluation via software possible</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Technical specifications on the UCI hardness tester PCE-3500</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td colspan="2">230 &#8230; 940 HV<br />
20 &#8230; 70 HRC<br />
90 &#8230; 650 HB<br />
370 &#8230; 1740 MPa</td>
</tr>
<tr>
<td>Accuracy</td>
<td colspan="2">+/- 3 % HV<br />
+/- 1,5 HRC<br />
+/- 3 % HB</td>
</tr>
<tr>
<td>Probes</td>
<td colspan="2">10 N UCI</td>
</tr>
<tr>
<td>Hardness scales</td>
<td colspan="2">HRC, HB, HV, HRB, HL, MPA</td>
</tr>
<tr>
<td>Materials</td>
<td colspan="2">UCI: steel (ferromagnetic)</td>
</tr>
<tr>
<td>Reference block</td>
<td colspan="2">136 ° Vickers diamond</td>
</tr>
<tr>
<td>Measurement direction</td>
<td colspan="2">360 °</td>
</tr>
<tr>
<td>Minimum material thickness</td>
<td colspan="2">1 mm (with UCI probe only)</td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">graphical colour LCD with backlight</td>
</tr>
<tr>
<td>Functions</td>
<td colspan="2">Single measurement, MIN / MAX / average value, number of measurements, mean value, standard deviation, variation coefficient, bar chart, Smart Mode (filters outliers)</td>
</tr>
<tr>
<td>Memory</td>
<td colspan="2">SD card</td>
</tr>
<tr>
<td>Interface</td>
<td colspan="2">USB</td>
</tr>
<tr>
<td>Operating conditions</td>
<td colspan="2">-20 &#8230; +40 °C; 30 &#8230; 80 % RH</td>
</tr>
<tr>
<td>Power supply</td>
<td colspan="2">6 V (3 x AA batteries)</td>
</tr>
<tr>
<td>Battery life</td>
<td colspan="2">approx. 10 hours</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="2">160 x 75 x 30 mm</td>
</tr>
<tr>
<td>Protection class</td>
<td colspan="2">IP 54</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">300 g (without probe)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-10/">Ultrasonic / UCI Hardness Tester PCE-3500-10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19031</post-id>	</item>
		<item>
		<title>Ultrasonic / UCI Hardness Tester PCE-3500</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:33:48 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19022</guid>

					<description><![CDATA[<p><strong>PCE-3500</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500/">Ultrasonic / UCI Hardness Tester PCE-3500</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div style="text-align: center"><strong>UCI Ultrasonic Tester PCE-3500 for non-destructive hardness measurement / Large</strong></div>
<div style="text-align: center"><strong>color LCD display / Including software / HV, HRC, HRB, HB and MPa scale / With memory function / Probes interchangeable / 136 ° Vickers diamond</strong></div>
</div>
<div>
<p align="justify">The UCI hardness tester PCE-3500 has been designed for the non-destructive hardness measurement of metallic components. The UCI hardness tester works on the basis of the Ultrasonic Contact Impedance test procedure. This UCI procedure works as follows: a Vickers diamond at the probe is stimulated with its self-resonance. By pushing the probe, the vibration frequency is reduced depending on the hardness of the surface and on the e module of the material and of the contact surface. The hardness of the surface can be determined on the basis of the frequency shift, taking the characteristic curve of the material into consideration.</p>
<p align="justify">The UCI hardness tester works non-destructively. There is a microscopically slight pressure against the surface, however, this is normally not visible. Due to the low penetration depth of the Vickers diamond, this UCI hardness tester is especially suitable for edge layer hardened components such as, for example, those that emerge when nitriding or induction hardening. It is typically used for punching tools, presses, thin-walled components, cog wheels, turbine blades, camshafts or weld seams. The UCI hardness tester is also suitable for many other hardness testing applications. It has exchangeable probes with different pressure forces and can therefore cover diverse applications.</p>
<p align="justify">After measuring the hardness of a component, the UCI hardness tester PCE-3500 shows different statistical values such as the MAX / MIN values and average values. Moreover, the standard deviation and further coefficients can be determined. A bar chart can be indicated. Since the UCI hardness tester is equipped with an internal memory, the measured data can be evaluated by means of a software.</p>
</div>
<div>
<div>&#8211; Measurement in line with UCI procedure<br />
&#8211; Tests HRC, HRB, HV, HB, MPa<br />
&#8211; Measurement direction 360°<br />
&#8211; Large colour LC display</div>
<div>&#8211; Memory function via SD card<br />
&#8211; Different probes can be attached<br />
&#8211; Characteristic curve of material pre-calibrated<br />
&#8211; Evaluation via software possible</div>
</div>
<div></div>
<div>
<table>
<tbody>
<tr>
<td colspan="3"><strong>Technical specifications on the UCI hardness tester PCE-3500</strong></td>
</tr>
<tr>
<td>Measurement range</td>
<td colspan="2">230 &#8230; 940 HV<br />
20 &#8230; 70 HRC<br />
90 &#8230; 650 HB<br />
370 &#8230; 1740 MPa</td>
</tr>
<tr>
<td>Accuracy</td>
<td colspan="2">+/- 3% HV<br />
+/- 1.5 HRC<br />
+/- 3% HB</td>
</tr>
<tr>
<td>Probes</td>
<td colspan="2">50 N UCI probe (10 N UCI probe optional)</td>
</tr>
<tr>
<td>Hardness scales</td>
<td colspan="2">HRC, HB, HV, HRB, HL, MPA</td>
</tr>
<tr>
<td>Materials</td>
<td colspan="2">UCI: steel (ferromagnetic)</td>
</tr>
<tr>
<td>Reference block</td>
<td colspan="2">136° Vickers diamond</td>
</tr>
<tr>
<td>Measurement direction</td>
<td colspan="2">360°</td>
</tr>
<tr>
<td>Minimum material thickness</td>
<td colspan="2">1 mm / .04 in (with UCI probe only)</td>
</tr>
<tr>
<td>Display</td>
<td colspan="2">graphical colour LCD with backlight</td>
</tr>
<tr>
<td>Functions</td>
<td colspan="2">Single measurement, MIN / MAX / average value, number of measurements, mean value, standard deviation, variation coefficient, bar chart, Smart Mode (filters outliers)</td>
</tr>
<tr>
<td>Memory</td>
<td colspan="2">SD card</td>
</tr>
<tr>
<td>Interface</td>
<td colspan="2">USB</td>
</tr>
<tr>
<td>Operating conditions</td>
<td colspan="2">-20 &#8230; 40°C / -4 &#8230; 104°F ; 30 &#8230; 80 % RH</td>
</tr>
<tr>
<td>Power supply</td>
<td colspan="2">6V (3 x AA batteries)</td>
</tr>
<tr>
<td>Battery life</td>
<td colspan="2">Approx. 10 hours</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="2">160 x 75 x 30 mm / 6.3 x 3 x 1.2 in</td>
</tr>
<tr>
<td>Protection class</td>
<td colspan="2">IP 54</td>
</tr>
<tr>
<td>Weight</td>
<td colspan="2">300 g / &lt; 1 lb (without probe)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500/">Ultrasonic / UCI Hardness Tester PCE-3500</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-uci-hardness-tester-pce-3500/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19022</post-id>	</item>
		<item>
		<title>Ultrasonic Flow Tester Kit PCE-TDS 100HSH-ICA &#038; Ultrasonic Thickness Tester &#038;Cal</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-kit-pce-tds-100hsh-ica-ultrasonic-thickness-tester-cal/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-kit-pce-tds-100hsh-ica-ultrasonic-thickness-tester-cal/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:28:43 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19016</guid>

					<description><![CDATA[<p><strong>PCE-TDS 100HSH-TG50-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-kit-pce-tds-100hsh-ica-ultrasonic-thickness-tester-cal/">Ultrasonic Flow Tester Kit PCE-TDS 100HSH-ICA &amp; Ultrasonic Thickness Tester &amp;Cal</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div align="center"><strong>Ultrasonic Flow Tester Kit PCE-TDS 100HSH incl. Ultrasonic Thickness Tester &amp; ISO Calibration Certificates<br />
according to the time difference method / for determining flow velocity and flow rate / Measuring method for liquids that are as homogeneous as possible</strong></div>
<p>The ultrasonic flow tester is required as part of a control measurement or for quickly determining the flow in a pipeline and is therefore a portable / easy-to-install measuring system. The ultrasonic flow meter works according to the transit time difference method. The measuring principle of the ultrasonic flow meter is quite simple.</p>
<p>Measuring a pipe obliquely with the flow takes less time than measuring against the flow. The stronger the current, the longer it takes to fight it and the faster you go with it. The difference between the flow times with the flow or against it therefore depends directly on the flow velocity of the river. The ultrasonic flow meter uses this effect to determine flow velocity and flow rate.</p>
<p>Electro-acoustic transducers (“piëzo effect”) send and receive short ultrasonic pulses through the medium flowing in the pipe. The transducers are offset in the longitudinal direction on both sides of the measuring tube. The non-destructive sensors are placed on the pipe and e.g. attached with a cable tie. The display shows the flow velocity within a short time. The ultrasonic flow meter can be used to measure on metallic pipes, plastic pipes or rubber pipes.</p>
<p><strong>Measurable liquids</strong><br />
Acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ether, ethyl ether, ethylene glycol, Freon R12, gasoline, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, motor oil , Diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1,1,1 &#8211; trichloroethane, turpentine, distilled water, sea water.</p>
<div align="center"><strong>Ultrasonic Material Thickness Gauge with a measuring range of 1.0 &#8230; 200 mm / integrated calibration block /  Interface cables and software(optional) / adjustable sound speed</strong></div>
<p>The ultrasonic material thickness meter is a compact measuring device for metals, glass and homogeneous plastics. This ultrasonic testing device works with an external ultrasonic probe, this probe guides ultrasonic waves into the material to be tested. Different materials transmit ultrasound at different speeds, so you can select different ultrasound speeds on the ultrasound tester.</p>
<p>With the thickness gauge, you can determine the material thicknesses of metal, glass and plastics and other homogeneous materials in seconds. The operation on the ultrasonic testing device is very easy using the seven buttons. This measuring device can be calibrated on site with little effort using the integrated calibration block. All measured values can be transferred to the PC and analyzed using the optionally available software. The software also offers the option of exporting the data to Microsoft Excel.</p>
<p><strong>Ultrasonic Flow Tester</strong><br />
&#8211; ideal for retrofitting<br />
&#8211; installation without process interruption<br />
&#8211; easy assembly<br />
&#8211; accurate and reliable<br />
&#8211; no pressure loss<br />
&#8211; maintenance-free, no moving parts<br />
&#8211; wear-free<br />
&#8211; portable devices for control measurements<br />
&#8211; <strong>incl. ISO calibration certificate</strong></p>
<p><strong>Ultrasonic Material Thickness Tester</strong><br />
&#8211; adjustable ultrasound velocity (for thickness measurements of different materials)<br />
&#8211; measures thicknesses from 1.2 &#8230; 200.00 mm / 0.05 &#8230; 7.87&#8243;<br />
&#8211; integrated steel calibration block<br />
&#8211; delivery incl. transport case<br />
&#8211; <strong>incl. ISO calibration certificate</strong></p>
<table>
<tbody>
<tr>
<td valign="top"><strong>Ultrasonic Flow Tester<br />
</strong></td>
<td valign="top"><strong>PCE-TDS 100HSH</strong></td>
</tr>
<tr>
<td valign="top">Handheld measuring range</td>
<td valign="top">-32 &#8230; +32 m/s</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.0001 m/s, 0.00033 ft/s</td>
</tr>
<tr>
<td valign="top">Accuracy for DN ≥ 50 mm:<br />
for DN &lt; 50 mm:</td>
<td valign="top">±1.5 % of measured value<br />
±3.5 % of measured value</td>
</tr>
<tr>
<td valign="top">Reproducibility</td>
<td valign="top">±1.0 % of measured value</td>
</tr>
<tr>
<td valign="top">Media</td>
<td valign="top">All liquids with an impurity &lt;5% and a flow &gt;0.03 m³/h</p>
<p>&nbsp;</td>
</tr>
<tr>
<td valign="top"><strong>Flow units</strong></td>
<td valign="top">Cubic meter [m³]
Liter [l]
Gallon (USA) [gal]
Imperial gallon (UK) [igl]
Million USA gallon [mgl]
Cubic foot [cf]
Barrel (USA) [bal]
Imperial barrel (UK) [ib]
Oil barrel [ob]
<p>&nbsp;</td>
</tr>
<tr>
<td valign="top"><strong>Time settings</strong></td>
<td valign="top">per day [/d]
per hour [/h]
per minute [/m]
and per second [/s]
<p>&nbsp;</td>
</tr>
<tr>
<td valign="top">Data logger</td>
<td valign="top">1800 measurements</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">USB (for online measurement and reading of the internal memory)</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">IP 52</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x AA NiMH rechargeable battery / 2100 mAh (at full charge 12h running time)<br />
100 … 240 V AC 50/60 Hz</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">214 x 104 x 40 mm / 8.4 x 4.1 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">450 g / 15 oz</td>
</tr>
<tr>
<td valign="top">Sensor (only PCE-TDS 100 HS)</td>
<td valign="top"><strong>Nominal width  DN 15 … 100, 20 … 108 mm / approx. 3/4 &#8230; 4&#8243;</strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><strong>Nominal width  DN 50 … 700, 57 … 720 mm / </strong><strong>approx. 2 … 28&#8243;</strong></td>
</tr>
<tr>
<td valign="top">Temperature of liquid</td>
<td valign="top">-30 … 160 °C / -22 &#8230; 320 °F</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">50 x 45 x 45 mm / 1.9 x 1.7 x 1.7&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">75 g / 2.6oz</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong>Ultrasonic Thickness Tester<br />
</strong></td>
<td valign="top"><strong>PCE-TG 50</strong></td>
</tr>
<tr>
<td valign="top">Measurement range</td>
<td valign="top">1.2 &#8230; 200 mm / 0.05 &#8230; 7.87 in (steel)</td>
</tr>
<tr>
<td valign="top">Accuracy</td>
<td valign="top">± 0.5% of rdg. ± 0.1 mm / ± 0.00393701 in</td>
</tr>
<tr>
<td valign="top">Transducer</td>
<td valign="top">5 MHz frequency, 8 mm / 0.32 inch diameter; Probe support surface: 10.2 mm / 0.4 in diameter; Head: 15.4 mm diameter / 0.61 in</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.1 mm / 0.001 in</td>
</tr>
<tr>
<td valign="top">Ultrasound velocity</td>
<td valign="top">800 &#8230; 9950 m/s / 2624.67 &#8230; 32644.36 ft/s (adjustable)</td>
</tr>
<tr>
<td valign="top">Display</td>
<td valign="top">4-digit LCD</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td valign="top">-10 &#8230; 50°C / 14 &#8230; 122°F; Relative humidity: &lt; 80% RH</td>
</tr>
<tr>
<td valign="top">Calibration block</td>
<td valign="top">5.0 mm / 0.2 in steel (integrated)</td>
</tr>
<tr>
<td valign="top">Measuring units</td>
<td valign="top">mm or in (adjustable)</td>
</tr>
<tr>
<td valign="top">Material temperature</td>
<td valign="top">0 &#8230; 50°C / 32 &#8230; 122°F (permanent); 50 &#8230; 85°C / 122 &#8230; 185°F (for 5 minutes, then 30 minutes cooling below 50° C / 122°F)</td>
</tr>
<tr>
<td valign="top">Data interface</td>
<td valign="top">RS-232 port</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x 1.5V AAA batteries (approx. 250 hours of battery life)</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">Approx. 142 x 77 x 40 mm / 5.6 x 3.1 x 1.6 inches (handset)</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">Approx. 265 g / &lt; 1 lb (handset with batteries and probe)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-kit-pce-tds-100hsh-ica-ultrasonic-thickness-tester-cal/">Ultrasonic Flow Tester Kit PCE-TDS 100HSH-ICA &amp; Ultrasonic Thickness Tester &amp;Cal</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-kit-pce-tds-100hsh-ica-ultrasonic-thickness-tester-cal/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19016</post-id>	</item>
		<item>
		<title>Ultrasonic Flow Tester PCE-TDS 100HS+-ICA incl. Thermometer &#038; ISO Cal. Certs.</title>
		<link>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hs-ica-incl-thermometer-iso-cal-certs/</link>
					<comments>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hs-ica-incl-thermometer-iso-cal-certs/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Tue, 04 May 2021 09:26:10 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19011</guid>

					<description><![CDATA[<p><strong>PCE-TDS 100HS+-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hs-ica-incl-thermometer-iso-cal-certs/">Ultrasonic Flow Tester PCE-TDS 100HS+-ICA incl. Thermometer &amp; ISO Cal. Certs.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<p align="center"><strong>Ultrasonic Flow </strong><strong>Tester PCE-TDS 100HS+-ICA incl. Thermometer &amp; ISO Calibration Certificates<br />
according to the transit time difference method / For determining flow velocity and flow / Measurement method for liquids that are as homogeneous as possible</strong></p>
<div>This is a portable handheld clamp-on ultrasonic flow tester used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 &#8230; 4 in. Ideal for use in oil and gas, water and wastewater, chemical, food and beverage, pharmaceutical, metals and mining, pulp and paper, power and heating, ventilation, air conditioning and refrigeration (HVACR) industries, this ultrasonic flow meter features user-friendly velcro-strap clamps that allow for quick and easy repositioning of the electroacoustic transducers.</div>
<div></div>
<div>Measurable liquids include: acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R 12, petrol, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, engine oil, diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1, 1, 1 &#8211; trichloroethane, turpentine, distilled water and sea water.</div>
<p>Calculation of flow velocity according to the transit-time principle follows the equation:</p>
<p align="center"><img decoding="async" src="http://www.industrial-needs.com/technical-data/images/ultrasonic-flow-meter-pce-tds-100h-calculation.jpg" width="190" height="45" border="0" /></p>
<p>v = measured velocity<br />
T1 = run time of the ultrasonic signal in the flow direction<br />
T2 = run time of the ultrasonic signal against the flow direction<br />
L = length of the ultrasonic wave<br />
α = ultrasonic signal angle to the flow</p>
<p><strong>The transit-time principle requires pipes to be full and have no bubbles and no particles.</strong></p>
<p>Each meter is assembled and calibrated by PCE Instruments in Germany. Therefore, a factory calibration certificate is provided by PCE Germany in the delivery contents of the meter. The certificate includes one measuring point on two different pipes. The reference display of the in-house test stand used by PCE for calibration has a valid DAkkS calibration certificate. This ensures traceability to the Physikalisch-Technische Bundesanstal (PTB) German national standard. Please note that because the meter&#8217;s measured values depend upon the pipe geometry, material and coating; the medium type, temperature and speed; and the sensor type and measuring method, these parameters are listed on the supplied certificate for maximum traceability.<br />
&#8211; ideal for retrofitting<br />
&#8211; installation without process interruption<br />
&#8211; easy assembly<br />
&#8211; accurate and reliable<br />
&#8211; no pressure loss<br />
&#8211; maintenance-free, no moving parts<br />
&#8211; wear-free<br />
&#8211; portable devices for control measurements<br />
&#8211; <strong>incl. ISO calibration certificates</strong><br />
<br class="clear" /></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot">
<table>
<tbody>
<tr>
<td colspan="2" valign="top"><strong>Technical Data Ultrasonic Flow </strong><strong>Tester PCE-TDS 100</strong></td>
</tr>
<tr>
<td valign="top">Handheld measuring range</td>
<td valign="top">-32 &#8230; +32 m/s</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.0001 m/s</td>
</tr>
<tr>
<td valign="top">Accuracy for DN ≥ 50 mm:<br />
for DN &lt; 50 mm:</td>
<td valign="top">±1.5 % of measured value<br />
±3.5 % of measured value</td>
</tr>
<tr>
<td valign="top">Reproducibility</td>
<td valign="top">±1.0 % of measured value</td>
</tr>
<tr>
<td valign="top">Media</td>
<td valign="top">All liquids with an impurity</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">&lt;5% and a flow &gt;0.03 m³/h</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Flow units</strong></td>
<td valign="top">Cubic meter [m³]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Liter [l]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Gallon (USA) [gal]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Imperial gallon (UK) [igl]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Million USA gallon [mgl]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Cubic foot [cf]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Barrel (USA) [bal]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Imperial barrel (UK) [ib]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Oil barrel [ob]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Time settings</strong></td>
<td valign="top">per day [/d]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">per hour [/h]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">per minute  [/m]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">and per second [/s]</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Data logger</td>
<td valign="top">1800 measurements</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td valign="top">USB (for online measurement and reading of the internal memory)</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">IP 52</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x AA NiMH rechargeable battery / 2100 mAh</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(at full charge 12h running time) 100 … 240 V AC 50/60 Hz</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">214 x 104 x 40 mm / 8.4 x 4.1 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">450 g / 15 oz</td>
</tr>
<tr>
<td valign="top">Sensor</td>
<td valign="top"><strong>nominal width DN 15 … 100, 20 … 108 mm / approx. 3/4 &#8230; 4&#8243;</strong></td>
</tr>
<tr>
<td valign="top">Temperature of liquid</td>
<td valign="top">-30 … 160 °C / -22 &#8230; 320 °F</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td valign="top">50 x 45 x 45 mm / 1.9 x 1.7 x 1.7&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">260 g / 9oz</td>
</tr>
<tr>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Technical data evaluation software</strong></td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Units of power W, kW, MW, J/h, kJ/h, MJ/h, Btu/h, kBtu/h, MBtu/h</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Units of energy J, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Graphical representation of flow, flow temperature,</td>
</tr>
<tr>
<td colspan="2" valign="top">  return temperature, heat output and heat quantity</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Tabular representation of flow, flow temperature,</td>
</tr>
<tr>
<td colspan="2" valign="top">  return temperature, heat output and heat quantity</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Mobile and stationary measurement mode</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Real-time data logger with unlimited runtime (only limited by PC memory capacity)</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; Data export function</td>
</tr>
<tr>
<td colspan="2" valign="top">&#8211; User-guided software operation with step-by-step instructions for</td>
</tr>
<tr>
<td colspan="2" valign="top">  device and software configuration</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong>Technical Data Temperature Datalogger PCE-T 330</strong></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type K  </strong></td>
<td valign="top">-200 … +1370 °C / -328 &#8230; 2498 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">0.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type T</strong></td>
<td valign="top">&#8211;200 … +400 °C / -328 &#8230; 752 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">00.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range thermocouple <strong>Type J</strong></td>
<td valign="top">&#8211;200 … +1200 °C /  -328 &#8230; 2192 °F</td>
</tr>
<tr>
<td valign="top">Resolution</td>
<td valign="top">00.01 °C</td>
</tr>
<tr>
<td valign="top">Accuracy*</td>
<td valign="top">±±(0.3 % of rdg. +0.40) °C*</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring rate</td>
<td valign="top">2/s</td>
</tr>
<tr>
<td valign="top">Operating temperature</td>
<td valign="top">-10 … +50 °C / 14 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top">Storage temperature</td>
<td valign="top">-20 … +60 °C (without batteries) / -4 &#8230; 140 °F</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x AAA batteries / 1.2 V battery</td>
</tr>
<tr>
<td valign="top">Battery life</td>
<td valign="top">ca. 190 h</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">(without backlight, battery capacity 1200 mAh,</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">ambient temperature 25 °C)</td>
</tr>
<tr>
<td valign="top">Protection class</td>
<td valign="top">IP52 (with protective cover and connected sensor)</td>
</tr>
<tr>
<td valign="top">Norm/ certification</td>
<td valign="top">CE/EMC ROHS</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hs-ica-incl-thermometer-iso-cal-certs/">Ultrasonic Flow Tester PCE-TDS 100HS+-ICA incl. Thermometer &amp; ISO Cal. Certs.</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/ultrasonic-tester-ultrasonic-testing/ultrasonic-flow-tester-pce-tds-100hs-ica-incl-thermometer-iso-cal-certs/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19011</post-id>	</item>
	</channel>
</rss>
