<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Voltmeter (DMM) - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/voltmeter-dmm/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/voltmeter-dmm/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Tue, 11 Aug 2026 16:16:02 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.14</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Voltmeter (DMM) - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/voltmeter-dmm/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>TECPEL HVP-40DM Digital High Voltage Meter High Precision Display</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/tecpel-hvp-40dm-digital-high-voltage-meter-high-precision-display/</link>
		
		<dc:creator><![CDATA[Alex]]></dc:creator>
		<pubDate>Tue, 11 Aug 2026 16:16:02 +0000</pubDate>
				<guid isPermaLink="false">https://www.amet.co.th/?post_type=product&#038;p=25845</guid>

					<description><![CDATA[<p>The TECPEL HVP-40DM Digital High Voltage Meter is desig [...]</p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/tecpel-hvp-40dm-digital-high-voltage-meter-high-precision-display/">TECPEL HVP-40DM Digital High Voltage Meter High Precision Display</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a>The TECPEL HVP-40DM Digital High Voltage Meter is designed for DC high voltage measurement, offering high precision in industrial test scenarios and suitable for high voltage system maintenance and measurement.</a></p>
<div class="col-md-6">
<h3 class="h5 mt-3">Measurement Specification</h3>
<ul class="list-icon mb-4 pb-2">
<li><strong>Input Impedance : </strong><a>2000MΩ</a></li>
<li><strong>Max Operation Voltage : </strong><a>40KV DC</a></li>
<li><strong>Display : </strong><a>3999 Digital LCD</a></li>
<li><strong>Resolution : </strong><a>10V / 1V / 0.1V</a></li>
<li><strong>Power Source : </strong><a>9V / 006P, IEC6L R1, NEDA 1604A</a></li>
</ul>
</div>
<div class="col-md-6">
<h3 class="h5 mt-3">Product Features</h3>
<ul class="list-icon mb-4 pb-2">
<li><strong>Auto Power Off : </strong><a>About 30 min</a></li>
<li><strong>Peak Hold : </strong><a>≧ 400ms</a></li>
<li><strong>Accuracy : </strong><a>Full Range ≦ 1.0% ± 2 digits</a></li>
<li><strong>Complies with Standards : </strong><a>CE, IEC1010</a></li>
</ul>
<h3 class="h5 mt-3">Product Information</h3>
<ul class="list-icon mb-4 pb-2">
<li><strong>Operating Temperature : </strong><a>0 °C ~ 50 °C</a></li>
<li><strong>Storage Temperature : </strong><a>-20 °C ~ +70 °C</a></li>
<li><strong>Dimensions : </strong><a>420 L x 80ψ</a></li>
<li><strong>Weight : </strong><a>360g</a></li>
<li><strong>Ground Lead Length : </strong><a>90cm</a></li>
</ul>
</div>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/tecpel-hvp-40dm-digital-high-voltage-meter-high-precision-display/">TECPEL HVP-40DM Digital High Voltage Meter High Precision Display</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">25845</post-id>	</item>
		<item>
		<title>Voltmeter PCE-GPA 50-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:58:34 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19210</guid>

					<description><![CDATA[<p><strong>PCE-GPA 50-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50-ica-incl-iso-calibration-certificate/">Voltmeter PCE-GPA 50-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Voltmeter PCE-GPA 50-ICA incl. ISO Calibration Certificate<br />
Current clamp up to 2000 A / TRMS measurement / Power measurement / Harmonic analysis / Graphic display with lighting / Data storage / Mains and battery operation</strong></div>
<div>The PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.</div>
<div></div>
<div>In addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.</div>
<p>&#8211; Graphic display<br />
&#8211; Data logger on Micro-SD card<br />
&#8211; Measurement for 1 and 3 phases<br />
&#8211; Temperature measurement with thermocouple<br />
&#8211; Voltage measurement 10V &#8230; 600V AC RMS<br />
&#8211; Current measurement 5 &#8230; 2000 A AC RMS<br />
&#8211; Current clamp opening 50 mm<br />
&#8211; Harmonic distortion up to the 50th order<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td valign="top" width="0"><strong>Type of measurement</strong></td>
<td colspan="3" valign="top" width="0"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong>AC voltage AC V    </strong></p>
</td>
<td valign="top"><strong>Measuring range      </strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">10 &#8230; 600V</td>
<td valign="top">0.1V</td>
<td valign="top">± (0.5% &#8230; 3 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Peak to peak</td>
<td valign="top">0.1V</td>
<td valign="top">± (5% &#8230; 30 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong>AC AC A</strong></p>
</td>
<td valign="top">5 &#8230; 2000 A</td>
<td valign="top">&lt; 100 A: 0.01 A</td>
<td valign="top">&lt; 200 A: ± (1% + 0.5 A)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top">&lt; 1000 A: 0.1 A</td>
<td valign="top">&gt; 200 A: ± (1% + 5 A)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Peak to peak</td>
<td valign="top">&gt; 1000 A: 1 A</td>
<td valign="top">± (5% + 30 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Power factor (PF)</strong></td>
<td valign="top">0 &#8230; 1</td>
<td valign="top">0.001</td>
<td valign="top">± 0.04</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Phase angle</strong></td>
<td valign="top">-180° &#8230; 180°</td>
<td valign="top">0.1°</td>
<td valign="top">± 1° x PF</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Frequency</strong></td>
<td valign="top">45 &#8230; 65 Hz</td>
<td valign="top">0.1 Hz</td>
<td valign="top">± 0.2 Hz</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Active, blind &amp;</strong></td>
<td valign="top">0 &#8230; 9,999 m</td>
<td valign="top">0.1 &#8230; 0.001 M</td>
<td valign="top">± (1.5% + 20 digits)</td>
</tr>
<tr>
<td valign="top"><strong>apparent power</strong></td>
<td valign="top">(W / VA / VAR)</td>
<td valign="top">(W / VA / VAR)</td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC V</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">0.1V</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">0.1V</td>
<td valign="top">± (4% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC A</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">&lt; 100 A: 0.01 A</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"><strong>Alternating current</strong></td>
<td valign="top"></td>
<td valign="top">&lt; 1000 A: 0.1 A</td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">&gt; 1000 A: 1 A</td>
<td valign="top">± (4% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Harmonic AC V%</strong></td>
<td valign="top">1 &#8230; 20th order</td>
<td valign="top">0.1%</td>
<td valign="top">± (2% + 10 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">21 &#8230; 50 okay</td>
<td valign="top">0.1%</td>
<td valign="top">± (4% + 20 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Absolute harmonic</strong></td>
<td valign="top">0 &#8230; 20%</td>
<td valign="top">0.1%</td>
<td valign="top">± (2% + 5 digits)</td>
</tr>
<tr>
<td valign="top"><strong>distortion</strong></td>
<td valign="top">20.1 &#8230; 100%</td>
<td valign="top">0.1%</td>
<td valign="top">± (6% + 10 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Temperature type K</strong></td>
<td valign="top">-100 &#8230; 199.9°C / -148 &#8230; 391.8°F</td>
<td valign="top">0.1°C / 0.18°F</td>
<td valign="top">± (1% + 1°C / 1.8°F)</td>
</tr>
<tr>
<td valign="top"><strong>thermocouple</strong></td>
<td valign="top">200 &#8230; 1300°C / 392 &#8230; 2372°F</td>
<td valign="top">1°C / 1.8°F</td>
<td valign="top">± (1% + 2°C / 3.6°F)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">Graphic LCD</td>
</tr>
<tr>
<td valign="top">AC V input impedance</td>
<td colspan="3" valign="top">10 MOhm</td>
</tr>
<tr>
<td valign="top">Frequency range</td>
<td colspan="3" valign="top">40 Hz &#8230; 1 kHz</td>
</tr>
<tr>
<td valign="top">Current Probe</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Calibrated frequency</td>
<td colspan="3" valign="top">45 &#8230; 65 Hz</td>
</tr>
<tr>
<td valign="top">Current Probe</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Overload protection</td>
<td colspan="3" valign="top">AC V: 720V RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">AC A: 2100 A</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td colspan="3" valign="top">Micro SD card</td>
</tr>
<tr>
<td valign="top">Refresh rate</td>
<td colspan="3" valign="top">1 second</td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Storage rate</td>
<td colspan="3" valign="top">2 &#8230; 7200s</td>
</tr>
<tr>
<td valign="top">Data storage</td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Storage format</td>
<td colspan="3" valign="top">XLS</td>
</tr>
<tr>
<td valign="top">Interface</td>
<td colspan="3" valign="top">Serial interface for live presentation to PC</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">(SOFT-LUT-USB is required)</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">2 x 1.5V AA battery</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">9V / 800-mA power supply</td>
</tr>
<tr>
<td valign="top">Current consumption</td>
<td colspan="3" valign="top">60-mA DC</td>
</tr>
<tr>
<td valign="top">Clamp opening</td>
<td colspan="3" valign="top">50 mm</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">About 595 g / 1.3 lbs</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">280 x 106 x 47 mm / 11 x 4.2 x 1.9 in</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50-ica-incl-iso-calibration-certificate/">Voltmeter PCE-GPA 50-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19210</post-id>	</item>
		<item>
		<title>Voltmeter PCE-GPA 50</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:57:14 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19208</guid>

					<description><![CDATA[<p><strong>PCE-GPA 50</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50/">Voltmeter PCE-GPA 50</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Voltmeter</strong><strong> PCE-GPA 50<br />
Current clamp up to 2000 A / TRMS measurement / Power measurement / Harmonic analysis / Graphic display with lighting / Data storage / Mains and battery operation</strong></div>
<div>The PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.</div>
<div></div>
<div>In addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.</div>
<p>&#8211; Graphic display<br />
&#8211; Data logger on Micro-SD card<br />
&#8211; Measurement for 1 and 3 phases<br />
&#8211; Temperature measurement with thermocouple<br />
&#8211; Voltage measurement 10V &#8230; 600V AC RMS<br />
&#8211; Current measurement 5 &#8230; 2000 A AC RMS<br />
&#8211; Current clamp opening 50 mm<br />
&#8211; Harmonic distortion up to the 50th order</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="0"><strong><span>Type of measurement</span></strong></td>
<td colspan="3" valign="top" width="0"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong><span>AC voltage AC V    </span></strong></p>
</td>
<td valign="top"><strong><span>Measuring range      </span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>10 &#8230; 600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (0.5% &#8230; 3 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Peak to peak</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (5% &#8230; 30 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">
<p align="justify"><strong><span>AC AC A</span></strong></p>
</td>
<td valign="top"><span>5 &#8230; 2000 A</span></td>
<td valign="top"><span>&lt; 100 A: 0.01 A    </span></td>
<td valign="top"><span>&lt; 200 A: ± (1% + 0.5 A)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"><span>&lt; 1000 A: 0.1 A</span></td>
<td valign="top"><span>&gt; 200 A: ± (1% + 5 A)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Peak to peak</span></td>
<td valign="top"><span>&gt; 1000 A: 1 A</span></td>
<td valign="top"><span>± (5% + 30 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Power factor (PF)</span></strong></td>
<td valign="top"><span>0 &#8230; 1</span></td>
<td valign="top"><span>0.001</span></td>
<td valign="top"><span>± 0.04</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Phase angle</span></strong></td>
<td valign="top"><span>-180° &#8230; 180°</span></td>
<td valign="top"><span>0.1°</span></td>
<td valign="top"><span>± 1° x PF</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency</span></strong></td>
<td valign="top"><span>45 &#8230; 65 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 0.2 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Active, blind &amp;</span></strong></td>
<td valign="top"><span>0 &#8230; 9,999 m</span></td>
<td valign="top"><span>0.1 &#8230; 0.001 M</span></td>
<td valign="top"><span>± (1.5% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>apparent power</span></strong></td>
<td valign="top"><span>(W / VA / VAR)</span></td>
<td valign="top"><span>(W / VA / VAR)</span></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC V</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± (4% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC A</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>&lt; 100 A: 0.01 A</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Alternating current</span></strong></td>
<td valign="top"></td>
<td valign="top"><span>&lt; 1000 A: 0.1 A</span></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>&gt; 1000 A: 1 A</span></td>
<td valign="top"><span>± (4% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonic AC V%</span></strong></td>
<td valign="top"><span>1 &#8230; 20th order</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>21 &#8230; 50 okay</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (4% + 20 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Absolute harmonic</span></strong></td>
<td valign="top"><span>0 &#8230; 20%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>distortion</span></strong></td>
<td valign="top"><span>20.1 &#8230; 100%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± (6% + 10 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Temperature type K</span></strong></td>
<td valign="top"><span>-100 &#8230; 199.9°C / -148 &#8230; 391.8</span>°F</td>
<td valign="top"><span>0.1°C / 0.18</span>°F</td>
<td valign="top"><span>± (1% + 1°C / 1.8°F)</span></td>
</tr>
<tr>
<td valign="top"><strong><span>thermocouple</span></strong></td>
<td valign="top"><span>200 &#8230; 1300°C / 392 &#8230; 2372</span>°F</td>
<td valign="top"><span>1°C / 1.8</span>°F</td>
<td valign="top"><span>± (1% + 2°C / 3.6°F)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="3" valign="top"><span>Graphic LCD</span></td>
</tr>
<tr>
<td valign="top"><span>AC V input impedance        </span></td>
<td colspan="3" valign="top"><span>10 MOhm</span></td>
</tr>
<tr>
<td valign="top"><span>Frequency range</span></td>
<td colspan="3" valign="top"><span>40 Hz &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Current Probe</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Calibrated frequency</span></td>
<td colspan="3" valign="top"><span>45 &#8230; 65 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Current Probe</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Overload protection</span></td>
<td colspan="3" valign="top"><span>AC V: 720V RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>AC A: 2100 A</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="3" valign="top"><span>Micro SD card</span></td>
</tr>
<tr>
<td valign="top"><span>Refresh rate</span></td>
<td colspan="3" valign="top"><span>1 second</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Storage rate</span></td>
<td colspan="3" valign="top"><span>2 &#8230; 7200s</span></td>
</tr>
<tr>
<td valign="top"><span>Data storage</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Storage format</span></td>
<td colspan="3" valign="top"><span>XLS</span></td>
</tr>
<tr>
<td valign="top"><span>Interface</span></td>
<td colspan="3" valign="top"><span>Serial interface for live presentation to PC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>(SOFT-LUT-USB is required)</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="3" valign="top"><span>2 x 1.5V AA battery</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"><span>9V / 800-mA power supply</span></td>
</tr>
<tr>
<td valign="top"><span>Current consumption</span></td>
<td colspan="3" valign="top"><span>60-mA DC</span></td>
</tr>
<tr>
<td valign="top"><span>Jaw Capacity</span></td>
<td colspan="3" valign="top"><span>50 mm</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="3" valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, max. 80% rh</span></td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top"><span>About 595 g / 1.3 lbs</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="3" valign="top"><span>280 x 106 x 47 mm / 11 x 4.2 x 1.9 in </span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50/">Voltmeter PCE-GPA 50</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-gpa-50/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19208</post-id>	</item>
		<item>
		<title>Voltmeter PCE-123</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-123/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-123/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:55:53 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19206</guid>

					<description><![CDATA[<p><strong>PCE-123</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-123/">Voltmeter PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Voltmeter indicates the nominal value for simulations and measurement of input<br />
electrical signals such as frequency and temperature</strong></div>
<div>The PCE-123 Voltmeter / nominal value indicator is a device that does need a mains connector and that is used to simulate regulation signals or units en the MSR technique with which it can test and calibrate almost any unit parameter and measuring instrument. The nominal value indicator provides an electrical output signal (mA, mV, V and frequency in Hz as well as temperature in °C or °F). The Voltmeter other automatic graduated functions, and selection of output signal jumps by percentage (0 to 100%) via the up/down keys and direct display of the output value. The device is easy to use and is operated via the keypad. THis device is attractive due to its high level of accuracy and its universal range of applications which no electrician or MSR department should go without, as well as within the industrial sector.<br />
This device we have on offer is a high quality alternative to those which are normally found on the market.</div>
<div>
<div> &#8211; 4 to 20mA (1kΩ, 24V power)<br />
&#8211; 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V<br />
&#8211; type-K, J, E, T temperature thermocouple sensors (°C or °F)<br />
&#8211; Frequency range 1 to 62,500Hz<br />
&#8211; Accuracy of 0.025%<br />
&#8211; Operated via keypad<br />
&#8211; Graduated automatic functions<br />
&#8211; Selectable between 0 to 20mA/ 0 to 24mA<br />
&#8211; Input 0 to 100% (mA, mV, V )<br />
&#8211; Alarm beep &#8216;open&#8217; (mA) or &#8216;short circuit&#8217; (mV, V)</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td colspan="2"><strong>mA DC current<br />
(maximum load at 1kΩ, powered by 24V)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>4 to 20mA / 0 to 20mA / 0 to 24mA</td>
</tr>
<tr>
<td>Resolution</td>
<td>1µA</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.025% ±3µA</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;1mA .</td>
</tr>
<tr>
<td colspan="2"><strong>mV current, V DC<br />
(power 1mA)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>0 to 100.00 mV<br />
0 to 10.000 V<br />
0 to 1.0000 V</td>
</tr>
<tr>
<td>Resolution</td>
<td>10 µV<br />
1 mV<br />
1.0000 V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 0.05% ±30 µV<br />
± 0.05% ±3 mV<br />
± 0.05% ±300 µV</td>
</tr>
<tr>
<td>Alert</td>
<td>beeps when there is a short circuit or ouput current &gt;10mV.</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature sensor thermocouple type-K, J, E, T<br />
(1 kΩ min.)</strong></td>
</tr>
<tr>
<td>Ranges</td>
<td>K: -200 &#8230; 0 °C / -328 &#8230; 32 °F and 0 &#8230; 1370 °C / 32 &#8230; 2498 °F<br />
J: -100 &#8230; 0 °C / -148 &#8230; 32 °F and 0 &#8230; 760 °C / 32 &#8230; 1400 °F<br />
E: -10 &#8230; 0 °C / 14 &#8230; 32 °F and 0 &#8230; 700°C / 32 &#8230; 1292 °F<br />
T: -200 &#8230; 0°C / -328 &#8230; 32 °F and T: 0 &#8230; 400 °C / 32 &#8230; 752 °F</td>
</tr>
<tr>
<td>Resolution</td>
<td>1°C (across entire range)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>K: ±1.1°C and ±0.8°C<br />
J:  ±0.9°C and ±0.7°C<br />
E: ±0.9°C and ±0.7°C<br />
T:  ±1.0°C and ±0.8°C</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>1 to 125Hz and 126 to 62.5kHz</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.04Hz</td>
</tr>
<tr>
<td>Selection</td>
<td>604 frequencies</td>
</tr>
<tr>
<td colspan="2"><strong>General characteristics</strong></td>
</tr>
<tr>
<td>Display</td>
<td>5 position LCD</td>
</tr>
<tr>
<td>Operating conditions</td>
<td>0 &#8230; 50 °C / 32 &#8230; 122 °F &lt;85% r.h.</td>
</tr>
<tr>
<td>Storage conditions</td>
<td>-20 &#8230; 60 °C / -4 &#8230; 140 °F; &lt;85% r.h.</td>
</tr>
<tr>
<td>Power</td>
<td>1 9V battery or 6 x 1.5V batteries</td>
</tr>
<tr>
<td>Consumption</td>
<td>60mA to 180mA (depending on output)</td>
</tr>
<tr>
<td>Battery indicator</td>
<td>5.5V for 150mA</td>
</tr>
<tr>
<td>Dimensions</td>
<td>88 x 168 x 26mm / 3.4 x 6.6 x 1 in</td>
</tr>
<tr>
<td>Weight</td>
<td>330 g / 11.6 oz</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-123/">Voltmeter PCE-123</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-123/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19206</post-id>	</item>
		<item>
		<title>Voltmeter PCE-LCT 3-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:54:14 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19204</guid>

					<description><![CDATA[<p><strong>PCE-LCT 3-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3-ica-incl-iso-calibration-certificate/">Voltmeter PCE-LCT 3-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Voltmeter for determining the leakage current / Temperature measurement with thermocouple / Inductive current measurement up to 150 A AC / Current probe opening 30 mm / Many measuring functions / incl. ISO Calibration Certificate</strong></div>
<p>The voltmeter is the ideal measuring instrument to measure leakage currents. This is made possible by the extensive measuring range of the multimeter. Also, current measurements up to 150 A AC can be made with the multimeter. To test supply lines with a current of up to 150 A, the multimeter for the corresponding cable cross-section can be opened up to 30 mm.</p>
<p>In addition to the current measurement, the multimeter can also measure voltages up to 600V directly. Because of the current and voltage measurement, the multimeter is the perfect measuring instrument to carry out measurements and analyzes on, for example, three-phase networks. For example, the continuity test can be used to find an incorrect wiring in sub-distribution boxes.</p>
<p>&#8211; 30 mm current clamp opening<br />
&#8211; Temperature measurement with thermocouple type K<br />
&#8211; Current measurement up to 150 A AC<br />
&#8211; Covers a wide range of measurements<br />
&#8211; Voltage measurement up to 600V AC / DC RMS<br />
&#8211; Transport bag for mobile use<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td valign="top"><strong>Measuring function<br />
</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>AC current</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td valign="top"><strong>Accuracy</strong></td>
<td valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">4 mA</td>
<td valign="top">0.001 mA</td>
<td valign="top">±(2% + 10 digits)</td>
<td valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top">40 mA</td>
<td valign="top">0.01 mA</td>
<td valign="top">±(2% + 10 digits)</td>
<td valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top">400 mA</td>
<td valign="top">0.1 mA</td>
<td valign="top">±(2% + 5 digits)</td>
<td valign="top">±(3% + 3 digits)</td>
</tr>
<tr>
<td valign="top">4 A</td>
<td valign="top">0.001 A</td>
<td valign="top">±(2% + 5 digits)</td>
<td valign="top">±(3% + 3 digits)</td>
</tr>
<tr>
<td valign="top">40 A</td>
<td valign="top">0.01 A</td>
<td valign="top">±(2% + 10 digits)</td>
<td valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top">150 A</td>
<td valign="top">0.1 A</td>
<td valign="top">±(2% + 10 digits)</td>
<td valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 Hz &#8230; 1 kHz (sine wave)</td>
</tr>
<tr>
<td colspan="4" valign="top">Maximum input current: 150 A AC</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>DC voltage</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">4 V</td>
<td valign="top">0.001 V</td>
<td colspan="2" valign="top">±(0.5% + 4 digits)</td>
</tr>
<tr>
<td valign="top">40 V</td>
<td valign="top">0.01 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">400 V</td>
<td valign="top">0.1 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">600 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Maximum input voltage: 600 V AC/DC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>AC voltage</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">4 V</td>
<td valign="top">0.001 V</td>
<td colspan="2" valign="top">±(1% + 3 digits)</td>
</tr>
<tr>
<td valign="top">40 V</td>
<td valign="top">0.01 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">400 V</td>
<td valign="top">0.1 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">600 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Maximum input voltage: 600 V AC/DC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 Hz &#8230; 1 kHz (sine wave)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Resistance</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">400 Ω</td>
<td valign="top">0.1 Ω</td>
<td colspan="2" valign="top">±(0.8% + 3 digits)</td>
</tr>
<tr>
<td valign="top">4 kΩ</td>
<td valign="top">0.001 kΩ</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">40 kΩ</td>
<td valign="top">0.01 kΩ</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">400 kΩ</td>
<td valign="top">0.1 kΩ</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">4 MΩ</td>
<td valign="top">0.001 MΩ</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">40 MΩ</td>
<td valign="top">0.01 MΩ</td>
<td colspan="2" valign="top">±(1% + 3 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Measuring voltage in open circuit: ca. 0.4 V</td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 600 V AC/DC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Continuity test</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">Beep at &lt;40 Ω</td>
<td valign="top">0.1Ω</td>
<td colspan="2" valign="top">&#8211;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 600 V AC/DC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Temperature</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">-20 &#8230; 0 °C</td>
<td valign="top">1 °C</td>
<td colspan="2" valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top">-4 &#8230; 32 °F</td>
<td valign="top">1 °F</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">-0 &#8230; 400 °C</td>
<td valign="top">1 °C</td>
<td colspan="2" valign="top">±(1.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">32 &#8230; 757 °F</td>
<td valign="top">1 °F</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">400 &#8230; 1000 °C</td>
<td valign="top">1 °C</td>
<td colspan="2" valign="top">±(3% + 5 digits)</td>
</tr>
<tr>
<td valign="top">752 &#8230; 1832 °F</td>
<td valign="top">1 °F</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 600 V AC/DC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">The temperature accuracies do not include the accuracies of the temperature sensors</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Capacity</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">40.00 nF</td>
<td valign="top">0.01 nF</td>
<td colspan="2" valign="top">±(3% + 8 digits)</td>
</tr>
<tr>
<td valign="top">400.0 nF</td>
<td valign="top">0.1 nF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">4.000 µF</td>
<td valign="top">0.001 µF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">40.00 µF</td>
<td valign="top">0.01 µF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">400.0 µF</td>
<td valign="top">0.1 µF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">4.000 mF</td>
<td valign="top">0.001 µF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top">40.00 mF</td>
<td valign="top">0.01 µF</td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 600 V AC/DC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Diode test</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">3.2 V</td>
<td valign="top">0.001 V</td>
<td colspan="2" valign="top">&#8211;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 600 V AC/DC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">Test voltage: 3.2 V</td>
</tr>
<tr>
<td colspan="4" valign="top">Forward current: 1 mA</td>
</tr>
<tr>
<td colspan="4" valign="top">The accuracies refer to the following ambient conditions: 23 ± 5 °C / 9°F and &lt;75 % r.H</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>General specifications</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Maximum current clamp opening</td>
<td colspan="3" valign="top">30 mm / 1.18&#8243;</td>
</tr>
<tr>
<td valign="top">Automatic shutdown</td>
<td colspan="3" valign="top">after 30 minutes, can be deactivated</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">2 x 1.5V AAA battery</td>
</tr>
<tr>
<td valign="top">Measuring rate</td>
<td colspan="3" valign="top">3 measurements per second</td>
</tr>
<tr>
<td valign="top">Display with overvoltage</td>
<td colspan="3" valign="top">&#8220;OL&#8221;</td>
</tr>
<tr>
<td valign="top">Maximum display</td>
<td colspan="3" valign="top">4000</td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">LC display</td>
</tr>
<tr>
<td valign="top">Maximum working height</td>
<td colspan="3" valign="top">2000 m / 13,123 ft</td>
</tr>
<tr>
<td valign="top">Temperature coefficient</td>
<td colspan="3" valign="top">0.1 x accuracy x °C*</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">18 &#8230; 28 °C / 64 &#8230; 82 °F</td>
</tr>
<tr>
<td valign="top">Storage conditions</td>
<td colspan="3" valign="top">-10 &#8230; 50 °C / 14 &#8230; 122 °F</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">213 x 62 x 38 mm / 8.4 x 2.4 x 1.5&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">ca. 238 g / 8.4 oz with batteries</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>Example:</strong></td>
</tr>
<tr>
<td colspan="4" valign="top">Is the current ambient temperature greater than the temperature of the operating conditions</td>
</tr>
<tr>
<td colspan="4" valign="top">(50°C / 122°F (current ambient temperature)) &#8211; (40°C 104°F (operating temperature)) = 10°C / 50°F</td>
</tr>
<tr>
<td colspan="4" valign="top">Is the current ambient temperature less than the temperature of the operating conditions</td>
</tr>
<tr>
<td colspan="4" valign="top">(0°C / 32°F (operating temperature)) &#8211; (-5°C / 23°F (current ambient temperature)) = 5°C / 41°F</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3-ica-incl-iso-calibration-certificate/">Voltmeter PCE-LCT 3-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19204</post-id>	</item>
		<item>
		<title>Voltmeter PCE-DC 20-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc-20-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc-20-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:53:03 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19202</guid>

					<description><![CDATA[<p><strong>PCE-DC 20-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc-20-ica-incl-iso-calibration-certificate/">Voltmeter PCE-DC 20-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Voltmeter incl. ISO Calibration Certificate<br />
AC / DC digital multimeter with direct frequency measurement on the clamp / LCD display / Automatic shutdown when not in use / Current measurement up to 1000 A / For mobile use / Current clamp opening 40 mm (1.6 in)</strong></div>
<p>The voltmeter is a versatile measuring instrument for the determination of currents, voltages and many other electrical quantities. With a current clamp opening of 40 mm / 1.6 in, even cables with a larger diameter can be tested with the digital multimeter. Thus, with the digital multimeter, current measurements of up to 1000 A AC / DC are possible.</p>
<p>The user can perform frequency measurements with this voltmeter. This ensures contactless frequency measurement with the digital multimeter. Thus, the digital multimeter is a useful addition to the equipment of an electrician.</p>
<p>&#8211; Current clamp opening 40 mm / 1.6 in<br />
&#8211; Backlit LCD display<br />
&#8211; Automatic shutdown<br />
&#8211; Ready for operation after switching on<br />
&#8211; Extensive measuring functions<br />
&#8211; Measuring range is selected automatically<br />
&#8211; <strong>incl. ISO Calibration Certificate</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>DC current</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top" width="86"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">400 A</td>
<td valign="top">0.1 A</td>
<td colspan="2" valign="top">±3 % + 5 digits</td>
</tr>
<tr>
<td valign="top">600 A</td>
<td valign="top">1 A</td>
<td colspan="2" valign="top">±3 % + 5 digits</td>
</tr>
<tr>
<td valign="top">1000 A</td>
<td valign="top">1 A</td>
<td colspan="2" valign="top">±3 % + 6 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 120% of the measuring range for a maximum of 60 seconds</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top" width="123"></td>
<td valign="top" width="121"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>AC current</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">400 A</td>
<td valign="top">0.1 A</td>
<td colspan="2" valign="top">±3 % + 5 digits</td>
</tr>
<tr>
<td valign="top">600 A</td>
<td valign="top">1 A</td>
<td colspan="2" valign="top">±3 % + 5 digits</td>
</tr>
<tr>
<td valign="top">1000 A</td>
<td valign="top">1 A</td>
<td colspan="2" valign="top">±3 % + 6 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 50 &#8230; 60 Hz</td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 120% of the measuring range for a maximum of 60 seconds</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>DC voltage</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">4 V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">±0.5 % + 5 digits</td>
</tr>
<tr>
<td valign="top">40 V</td>
<td valign="top">10 mV</td>
<td colspan="2" valign="top">±0.5 % + 5 digits</td>
</tr>
<tr>
<td valign="top">400 V</td>
<td valign="top">0.1 V</td>
<td colspan="2" valign="top">±0.5 % + 5 digits</td>
</tr>
<tr>
<td valign="top">600 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">1000 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 1000 VDC or 700 VAC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>AC </strong><strong>voltage</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">4 V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">±1.2 % + 5 digits</td>
</tr>
<tr>
<td valign="top">40 V</td>
<td valign="top">10 mV</td>
<td colspan="2" valign="top">±1.2 % + 5 digits</td>
</tr>
<tr>
<td valign="top">400 V</td>
<td valign="top">0.1 V</td>
<td colspan="2" valign="top">±1.2 % + 5 digits</td>
</tr>
<tr>
<td valign="top">600 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top">±2 % + 5 digits</td>
</tr>
<tr>
<td valign="top">1000 V</td>
<td valign="top">1 V</td>
<td colspan="2" valign="top">±2 % + 5 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Input impedance: 10 MΩ</td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 1000 VDC or 700 VAC RMS</td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 &#8230; 400 Hz</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Resistance</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">400 Ω</td>
<td valign="top">0.1 Ω</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">4 kΩ</td>
<td valign="top">1 Ω</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">40 kΩ</td>
<td valign="top">10 Ω</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">400 kΩ</td>
<td valign="top">0.1 kΩ</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">4 MΩ</td>
<td valign="top">1 kΩ</td>
<td colspan="2" valign="top">±1 % + 5 digits</td>
</tr>
<tr>
<td valign="top">40 MΩ</td>
<td valign="top">10 kΩ</td>
<td colspan="2" valign="top">±2 % + 5 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overvoltage protection: 250 V AC/DC RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Frequency (direct)</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">40 Hz</td>
<td valign="top">1 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top">400 Hz</td>
<td valign="top">1 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top">4 kHz</td>
<td valign="top">10 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top">40 kHz</td>
<td valign="top">100 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top">100 kHz</td>
<td valign="top">100 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Measuring range: 1 &#8230; 10 V RMS, 40 Hz &#8230; 100 kHz</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Frequency (current clamp)</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">40 Hz</td>
<td valign="top">0.01 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top">400 Hz</td>
<td valign="top">0.1 Hz</td>
<td colspan="2" valign="top">±0.1 % + 1 digits</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 &#8230; 400 Hz (&gt;20 A)</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Further measuring functions</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Continuity test</td>
<td colspan="3" valign="top">audible signal at &lt;40 Ω</td>
</tr>
<tr>
<td valign="top">Diode test</td>
<td colspan="3" valign="top">indicates forward voltage</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>General specifications</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring rate</td>
<td colspan="3" valign="top">2 &#8230; 3 measurements per second</td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">LCD 3999 Digits</td>
</tr>
<tr>
<td valign="top">Measuring range selection</td>
<td colspan="3" valign="top">automatically</td>
</tr>
<tr>
<td valign="top">Automatic shutdown</td>
<td colspan="3" valign="top">after 30 minutes of inactivity, deactivatable</td>
</tr>
<tr>
<td valign="top">Maximum clamp opening</td>
<td colspan="3" valign="top">40 mm / 1.6&#8243;</td>
</tr>
<tr>
<td valign="top">Coefficients</td>
<td colspan="3" valign="top">0.1 x accuracy x °C*</td>
</tr>
<tr>
<td valign="top">Maximum voltage</td>
<td colspan="3" valign="top">1000 V CAT II, 600 V CAT III</td>
</tr>
<tr>
<td valign="top">Maximum working height</td>
<td colspan="3" valign="top">2000 m / 6561 ft</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">5 &#8230; 35 °C / 41 &#8230; 95 °F, &lt;75 % RH</td>
</tr>
<tr>
<td valign="top">Storage conditions</td>
<td colspan="3" valign="top">-10 &#8230; 35 °C / 14 &#8230; 95 °F, &lt;75 % RH</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">3 x 1.5 V AAA batteries</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">225 x 86 x 32 mm / 8.9 x 3.4 x 1.3&#8243;</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">ca. 330 g / 11.6 oz</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Accuracies are given at ambient conditions of 18 &#8230; 28 °C, 65 &#8230; 83 °F.</td>
</tr>
<tr>
<td colspan="4" valign="top">*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><strong>Example:</strong></td>
</tr>
<tr>
<td colspan="4" valign="top">Is the current ambient temperature greater than the temperature of the operating conditions</td>
</tr>
<tr>
<td colspan="4" valign="top">(50 °C/ 122°F (current ambient temperature)) &#8211; (40 °C / 104°F (operating temperature)) = 10 °C / 50°F</td>
</tr>
<tr>
<td colspan="4" valign="top">Is the current ambient temperature less than the temperature of the operating conditions</td>
</tr>
<tr>
<td colspan="4" valign="top">(0 °C / 32°F (operating temperature)) &#8211; (-5 °C / 23°F (current ambient temperature)) = 5 °C / 41°F</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc-20-ica-incl-iso-calibration-certificate/">Voltmeter PCE-DC 20-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc-20-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19202</post-id>	</item>
		<item>
		<title>Voltmeter PCE-PCM 3</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-pcm-3/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-pcm-3/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:51:57 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19200</guid>

					<description><![CDATA[<p><strong>PCE-PCM 3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-pcm-3/">Voltmeter PCE-PCM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Voltmeter </strong><strong>PCE-PCM 3<br />
Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var / Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement / Backlight / Voltage measurement / 750 kW power </strong></div>
<div>With the digital multimeter AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the digital multimeter. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the digital multimeter is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional digital multimeter such a measurement is not possible. For the digital multimeter this is not a problem.</div>
<div></div>
<div>With the NCV (Not Connected Voltage) function of the digital multimeter, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the digital multimeter. In addition to the measuring function, the digital multimeter can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the digital multimeter to the terminal, where it can be logged, analyzed and sent.</div>
<p>&#8211; Apparent / active / reactive power<br />
&#8211; Measurement up to the 20th harmonic<br />
&#8211; &#8220;Not Connected Voltage&#8221; function<br />
&#8211; Inrush current measurement<br />
&#8211; Current measurement up to 1000 A AC<br />
&#8211; Bluetooth interface</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td colspan="3" valign="top"><span>Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, &lt; 75% RH</span></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Current measurement AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 A</span></td>
<td valign="top"><span>0.01 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600 A</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000 A</span></td>
<td valign="top"><span>1 A</span></td>
<td valign="top"><span>± 2% + 8 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input current: 1000 A AC</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230;. 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Inrush current AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>60 A</span></td>
<td valign="top"><span>0.01 A</span></td>
<td valign="top"><span>For reference only</span></td>
</tr>
<tr>
<td valign="top"><span>600 A</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± 5% + 60 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000 A</span></td>
<td valign="top"><span>1 A</span></td>
<td valign="top"><span>± 5% + 60 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Integral time: 100 ms</span></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="2" valign="top"><span>Measuring range: 20 &#8230; 1000 A</span></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230;. 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement DC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± 0.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 0.8% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 750V AC (rms value) or 1000V DC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement AC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>6V</span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60V</span></td>
<td valign="top"><span>0.01V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>0.1V</span></td>
<td valign="top"><span>± 0.6% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 0.8% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 750V AC (rms value) or 1000V DC</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 40 &#8230; 400 Hz</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement with</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>The current measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range of the input signal: &gt; 20 AAC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The input current increases with the measuring frequency.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input current: 1000 AAC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement with the</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Voltage measurement function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 kHz</span></td>
<td valign="top"><span>0.001 kHz</span></td>
<td valign="top"><span>± 1.5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range: 10 &#8230; 10 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring range of the input signal: &gt; 1V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top" height="27"><span>The input current increases with the measuring frequency.</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Maximum input voltage: 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Frequency measurement </span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>9,999 Hz</span></td>
<td valign="top"><span>0.001 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 Hz</span></td>
<td valign="top"><span>0.01 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 kHz</span></td>
<td valign="top"><span>0.1 Hz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 Hz</span></td>
<td valign="top"><span>0.001 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 kHz</span></td>
<td valign="top"><span>0.01 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 kHz</span></td>
<td valign="top"><span>0.1 kHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999 MHz</span></td>
<td valign="top"><span>0.001 MHz</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 1000V DC or 750V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Range of voltage input&gt; 2V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(as the input voltage increases, so does the frequency)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Duty cycle</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.1 &#8230; 99.9%</span></td>
<td valign="top"><span>0.1%</span></td>
<td valign="top"><span>± 0.3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Frequency range: 10 &#8230; 10 kHz</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Voltage range: 2 &#8230; 250V AC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(The voltage increases with the frequency)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Duty cycle with the</span></td>
<td colspan="2" valign="top"><span>Frequency range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Current measurement function</span></td>
<td colspan="2" valign="top"><span>Input current: 20 &#8230; 1000 AAC (rms value)</span></td>
</tr>
<tr>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Duty cycle with the</span></td>
<td colspan="2" valign="top"><span>Frequency range: 10 &#8230; 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Voltage measurement function</span></td>
<td colspan="2" valign="top"><span>Input current: 1 &#8230; 750V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Input impedance: 1MΩ</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Resistivity</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>6 kΩ</span></td>
<td valign="top"><span>0.001 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60 kΩ</span></td>
<td valign="top"><span>0.01 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>600 kΩ</span></td>
<td valign="top"><span>0.1 kΩ</span></td>
<td valign="top"><span>± 0.8% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>6 MΩ</span></td>
<td valign="top"><span>0.001 MΩ</span></td>
<td valign="top"><span>± 2% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>60 MΩ</span></td>
<td valign="top"><span>0.1 MΩ</span></td>
<td valign="top"><span>± 2% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Measuring voltage: approx. 0.78V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Continuity test</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>600 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Acoustic signal at &lt; 50 Ω</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Test voltage: 1.48V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Capacitance measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>9.999 nF</span></td>
<td valign="top"><span>0.001 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 n.f.</span></td>
<td valign="top"><span>0.01 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 nF</span></td>
<td valign="top"><span>0.1 nF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9.999 μF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 μF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>999.9 μF</span></td>
<td valign="top"><span>0.1 μF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9,999mF</span></td>
<td valign="top"><span>0.001 mF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>99.99 mF</span></td>
<td valign="top"><span>0.01 mF</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Diode measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>3V </span></td>
<td valign="top"><span>0.001V</span></td>
<td valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>DC anode side: approx. 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>DC cathode side: approx. 3.2V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Overvoltage protection: 750V DC, 1000V AC (rms value)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Single phase power measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>3 W / VA / Var</span></td>
<td valign="top"><span>0.01 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>100 W / VA / Var</span></td>
<td valign="top"><span>0.1 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4000 W / VA / Var</span></td>
<td valign="top"><span>1 W / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>10 kW / VA / var</span></td>
<td valign="top"><span>0.01 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>100 kW / VA / var</span></td>
<td valign="top"><span>0.1 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>750 kW / VA / var</span></td>
<td valign="top"><span>1 kW / VA / Var</span></td>
<td valign="top"><span>± 3% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Power factor capacitive / inductive</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>0.1 &#8230; 1</span></td>
<td valign="top"><span>0.001</span></td>
<td valign="top"><span>± 5% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring function</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Harmonics measurement</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Measuring range</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
<td valign="top"><strong><span>Accuracy</span></strong></td>
</tr>
<tr>
<td valign="top"><span>1</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 3% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>2 &#8230; 6</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 3.5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>7 &#8230; 8</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 4.5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>9 &#8230; 10</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 5% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>11 &#8230; 15</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 7% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>16 &#8230; 20</span></td>
<td valign="top"><span>&#8211;</span></td>
<td valign="top"><span>± 10% + 10 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring current: 1-mA</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Smallest measuring voltage: 1V</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>The resolution depends on the voltage measuring range</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>General specifications</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td colspan="2" valign="top"><span>Automatically and manually adjustable</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum voltage range</span></td>
<td colspan="2" valign="top"><span>1000V DC or 750V AC</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum working height</span></td>
<td colspan="2" valign="top"><span>2000 m / 6561 ft</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>LCD</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum display</span></td>
<td colspan="2" valign="top"><span>5999 Dgt.</span></td>
</tr>
<tr>
<td valign="top"><span>Overrange</span></td>
<td colspan="2" valign="top"><span>&#8220;OIL&#8221;</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring range underflow</span></td>
<td colspan="2" valign="top"><span>&#8220;-OL&#8221;</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring rate</span></td>
<td colspan="2" valign="top"><span>3 Hz</span></td>
</tr>
<tr>
<td valign="top"><span>Automatic shutdown</span></td>
<td colspan="2" valign="top"><span>After 30 minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="2" valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Battery indicator</span></td>
<td colspan="2" valign="top"><span>Icon if the battery voltage is too low</span></td>
</tr>
<tr>
<td valign="top"><span>Temperature coefficient</span></td>
<td colspan="2" valign="top"><span>0.1 x accuracy x °C / °F*</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="2" valign="top"><span>0 &#8230; 40°C, 32 &#8230; 104°F</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td colspan="2" valign="top"><span>-10 &#8230; 60°C, 14 &#8230; 140°F</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  </span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>About 420 g / &lt; 1 lb (with batteries)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Accuracies are given at ambient conditions of 18 &#8230; 28°C / 65 &#8230; 83°F.</span><br />
<span>*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Example:</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Is the current ambient temperature greater than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(50°C / 122°F (current ambient temperature)) &#8211; (40°C / 104°F (operating temperature)<br />
</span><span>= 10°C / 50</span>°F</td>
</tr>
<tr>
<td colspan="3" valign="top"><span>Is the current ambient temperature less than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="3" valign="top"><span>(0°C (operating temperature)) &#8211; (-5°C / 23°F (current ambient temperature))<br />
</span><span>= 5°C / 41</span>°F</td>
</tr>
<tr>
<td colspan="3" valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-pcm-3/">Voltmeter PCE-PCM 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-pcm-3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19200</post-id>	</item>
		<item>
		<title>Voltmeter PCE-LCT 3</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:50:55 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19198</guid>

					<description><![CDATA[<p><strong>PCE-LCT 3</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3/">Voltmeter PCE-LCT 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Voltmeter</strong><strong> PCE-LCT 3 </strong></div>
<div><strong>Multimeter for determining the leakage current / Temperature measurement with thermocouple / Inductive current measurement up to 150 A AC / Current probe opening 30 mm / Many measuring functions</strong></div>
<div></div>
<div>The multimeter is the ideal measuring instrument to measure leakage currents. This is made possible by the extensive measuring range of the multimeter. Also, current measurements up to 150 A AC can be made with the multimeter. To test supply lines with a current of up to 150 A, the multimeter for the corresponding cable cross-section can be opened up to 30 mm.</div>
<div></div>
<div>In addition to the current measurement, the multimeter can also measure voltages up to 600V directly. Because of the current and voltage measurement, the multimeter is the perfect measuring instrument to carry out measurements and analyzes on, for example, three-phase networks. For example, the continuity test can be used to find a wrong wiring in sub-distribution boxes.</div>
<p>&#8211; 30 mm current clamp opening<br />
&#8211; Temperature measurement with thermocouple type K<br />
&#8211; Current measurement up to 150 A AC<br />
&#8211; Covers a wide range of measurements<br />
&#8211; Voltage measurement up to 600V AC / DC RMS<br />
&#8211; Transport bag for mobile use</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<div id="tab-customdata3" class="tab-pane fade active in">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>AC current measurement</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution   </span></td>
<td valign="top"><span>Accuracy</span></td>
<td valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>4-mA</span></td>
<td valign="top"><span>0.001-mA</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
<td valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40-mA</span></td>
<td valign="top"><span>0.01-mA</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
<td valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>400-mA</span></td>
<td valign="top"><span>0.1-mA</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
<td valign="top"><span>± (3% + 3 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>4 A</span></td>
<td valign="top"><span>0.001 A</span></td>
<td valign="top"><span>± (2% + 5 digits)</span></td>
<td valign="top"><span>± (3% + 3 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40 A</span></td>
<td valign="top"><span>0.01A</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
<td valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>150 A</span></td>
<td valign="top"><span>0.1 A</span></td>
<td valign="top"><span>± (2% + 10 digits)</span></td>
<td valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Frequency range: 40 Hz &#8230; 1 kHz (sine wave)</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Maximum input current: 150 A AC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>DC voltage</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>0.001V</span></td>
<td colspan="2" valign="top"><span>± (0.5% + 4 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>0.01V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>0.1V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>1V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Maximum input voltage: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>AC voltage </span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>0.001V</span></td>
<td colspan="2" valign="top"><span>± (1% + 3 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>0.01V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>0.1V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>600V</span></td>
<td valign="top"><span>1V</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Input impedance: 10 MΩ</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>maximum input voltage: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Frequency range: 40 Hz &#8230; 1 kHz (sine wave)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Resistance</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>400 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td colspan="2" valign="top"><span>± (0.8% + 3 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>4 kΩ</span></td>
<td valign="top"><span>0.001 kΩ</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>40 kΩ</span></td>
<td valign="top"><span>0.01 kΩ</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>400 kΩ</span></td>
<td valign="top"><span>0.1 kΩ</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>4 MΩ</span></td>
<td valign="top"><span>0.001 MΩ</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>40 MΩ</span></td>
<td valign="top"><span>0.01 MΩ</span></td>
<td colspan="2" valign="top"><span>± (1% + 3 digits)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Measuring voltage in open circuit: approx. 0.4V</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Overvoltage protection: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>Beep at &lt; 40 Ω</span></td>
<td valign="top"><span>0,1Ω</span></td>
<td colspan="2" valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Overvoltage protection: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Temperature</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>-20 &#8230; 0°C</span></td>
<td valign="top"><span>1°C</span></td>
<td colspan="2" valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>-4 &#8230; 32°F</span></td>
<td valign="top"><span>1°F</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>-0 &#8230; 400°C</span></td>
<td valign="top"><span>1°C</span></td>
<td colspan="2" valign="top"><span>± (1.5% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>32 &#8230; 757°F</span></td>
<td valign="top"><span>1°F</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>400 &#8230; 1000°C</span></td>
<td valign="top"><span>1°C</span></td>
<td colspan="2" valign="top"><span>± (3% + 5 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>752 &#8230; 1832°F</span></td>
<td valign="top"><span>1°F</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Overvoltage protection: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>The temperature accuracies do not include the accuracies of the temperature sensors</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Capacity</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>40.00 n</span></td>
<td valign="top"><span>0.01 nF</span></td>
<td colspan="2" valign="top"><span>± (3% + 8 digits)</span></td>
</tr>
<tr>
<td valign="top"><span>400.0 nF</span></td>
<td valign="top"><span>0.1 nF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>4,000 μF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>40.00 μF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>400.0 μF</span></td>
<td valign="top"><span>0.1 μF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>4,000mF</span></td>
<td valign="top"><span>0.001 μF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>40.00 mF</span></td>
<td valign="top"><span>0.01 μF</span></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Overvoltage protection: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Diode test</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td colspan="2" valign="top"><span>Accuracy</span></td>
</tr>
<tr>
<td valign="top"><span>3.2V</span></td>
<td valign="top"><span>0.001V</span></td>
<td colspan="2" valign="top"><span>&#8211;</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Overvoltage protection: 600V AC / DC RMS</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Test voltage: 3.2V</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Forward current: 1-mA</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>The accuracies refer to the following ambient conditions: 23 ± 5°C / 9°F and &lt; 75% RH</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>General specifications</span></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Maximum current clamp opening</span></td>
<td colspan="3" valign="top"><span>30 mm</span></td>
</tr>
<tr>
<td valign="top"><span>Automatic shutdown</span></td>
<td colspan="3" valign="top"><span>After 30 minutes, can be deactivated</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td colspan="3" valign="top"><span>2 x 1.5V AAA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring rate</span></td>
<td colspan="3" valign="top"><span>3 measurements per second</span></td>
</tr>
<tr>
<td valign="top"><span>Display with overvoltage</span></td>
<td colspan="3" valign="top"><span>&#8220;OIL&#8221;</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum display</span></td>
<td colspan="3" valign="top"><span>4000</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="3" valign="top"><span>LCD display</span></td>
</tr>
<tr>
<td valign="top"><span>Maximum working height</span></td>
<td colspan="3" valign="top"><span>2,000 m / 13,123 ft</span></td>
</tr>
<tr>
<td valign="top"><span>Temperature coefficient</span></td>
<td colspan="3" valign="top"><span>0.1 x accuracy x °C, °F*</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td colspan="3" valign="top"><span>18 &#8230; 28°C / 64 &#8230; 82</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Store control admixtures</span></td>
<td colspan="3" valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122</span>°F</td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="3" valign="top"><span>213 x 62 x 38 mm / 8.4 x 2.4 x 1.5 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="3" valign="top"><span>About 238 g / &lt; 1 lb with batteries</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.</span></td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Example:</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Is the current ambient temperature greater than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>(50°C / 122°F (current ambient temperature)) &#8211; (40°C 104°F (operating temperature)) = 10°C / 50</span>°F</td>
</tr>
<tr>
<td colspan="4" valign="top"><span>Is the current ambient temperature less than the temperature of the operating conditions</span></td>
</tr>
<tr>
<td colspan="4" valign="top"><span>(0°C / 32°F (operating temperature)) &#8211; (-5°C / 23°F (current ambient temperature)) = 5°C / 41</span>°F</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3/">Voltmeter PCE-LCT 3</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lct-3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19198</post-id>	</item>
		<item>
		<title>Voltmeter PCE-DC3-ICA incl. ISO Calibration Certificate</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc3-ica-incl-iso-calibration-certificate/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc3-ica-incl-iso-calibration-certificate/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:49:51 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19196</guid>

					<description><![CDATA[<p><strong>PCE-DC3-ICA</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc3-ica-incl-iso-calibration-certificate/">Voltmeter PCE-DC3-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div align="center"><strong>Voltmeter</strong><br />
<strong>DCA zero point function / AC/DC current measurement up to 80 A /</strong><br />
<strong>Automatic range selection / Clamp opening: 18 mm / 0.7&#8243; / incl. ISO Calibration Certificate</strong></div>
<p>This voltmeter was developed for the indirect measurement of AC/DC currents with high resolution. A non-contact voltage tester function and a torch/flashlight for illuminating the measuring point have also been integrated into this clamp meter. The small dimensions of this amperage clamp enable it to be used in places that are difficult to access.</p>
<p>The large, illuminated display of these measuring clamps ensures very good readability even in dark locations, such as in switch cabinets and cable ducts. The non-contact voltage tester function not only supports you in the detection of dangerous voltage potentials, but also gives you a precise tool for determining cable break positions in cable reels, extension cables and appliance connection cables.</p>
<div>
<div>&#8211; 4 digit LCD display with backlighting<br />
&#8211; AC/DC current measurement up to 80 Amps<br />
&#8211; Save function<br />
&#8211; DCA zero rest function<br />
&#8211; Current tester, non-contact<br />
&#8211; Integrated light to illuminate measured area<br />
&#8211; Automatic range selection<br />
&#8211; Automatic disconnect<br />
&#8211; Clamp diameter: 18 mm / .7 in<br />
&#8211; <strong>Incl. ISO Calibration Certificate</strong></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<table>
<tbody>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td>AC current<br />
(50 / 60 Hz)</td>
<td>Range / Resolution / Accuracy<br />
2 A  / 1-mA / ± 2.8% + 10 dgt<br />
80 A / 100-mA / ± 3.0% + 8 dgt</td>
</tr>
<tr>
<td>DC current</td>
<td>Range / Resolution / Accuracy<br />
2 A / 1-mA / ± 3.0% + 10 dgt<br />
80 A / 100-mA / ± 3.0% + 8 dgt</td>
</tr>
<tr>
<td>AC overload protection<br />
(Non-contact)</td>
<td>100V AC up to 600V AC 50 / 60 Hz</td>
</tr>
<tr>
<td>Flashlight illumination</td>
<td>White LED</td>
</tr>
<tr>
<td>Conductor diameter</td>
<td>18 mm / 0.7 in maximum</td>
</tr>
<tr>
<td>Display</td>
<td>3 2/3 digit LCD display with backlighting</td>
</tr>
<tr>
<td>Power</td>
<td>2 &#8211; 1.5V AAA batteries</td>
</tr>
<tr>
<td>Casing</td>
<td>PVC</td>
</tr>
<tr>
<td>Dimensions</td>
<td>164 x 65 x 32 mm / 6.4 x 2.5 x 1.2 in</td>
</tr>
<tr>
<td>Weight</td>
<td>175 g / &lt; 1 lb</td>
</tr>
<tr>
<td>Standards</td>
<td>EN61010-1; CAT II / 600V<br />
EN61010-2-032; CAT III / 300V</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc3-ica-incl-iso-calibration-certificate/">Voltmeter PCE-DC3-ICA incl. ISO Calibration Certificate</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-dc3-ica-incl-iso-calibration-certificate/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19196</post-id>	</item>
		<item>
		<title>Voltmeter PCE-LT 15</title>
		<link>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lt-15/</link>
					<comments>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lt-15/#respond</comments>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 05 May 2021 04:48:33 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=19194</guid>

					<description><![CDATA[<p><strong>PCE-LT 15</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lt-15/">Voltmeter PCE-LT 15</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata1" class="tab-pane fade in active">
<div class="usertext">
<div><strong>Voltmeter PCE-LT 15<br />
LAN tester for fast network cable inspection / Combination device consisting of LAN tester and multimeter with voltage and resistance measurement</strong></div>
<div>The LAN tester PCE-LT 15 is a combination device which detects configuration errors in the network and at the same time can be used as a multimeter. Thus, the periphery of a network can be quickly checked with the LAN tester. With the LAN tester PCE-LT 15 it is possible to check 8-pin data cables with RJ-45 connectors for continuity, open connections, and short circuits. In addition to the LAN test function, the LAN Tester can also measure DC and AC voltages.</div>
<div></div>
<div>With the LAN tester, which also serves as a multimeter, it is possible to perform a continuity test with buzzer and a diode test. The LAN tester is also a device that identifies the most common network installation errors. The two-row LEDs successively indicate the pin assignment of the cable to be tested. In the event of a short circuit, more than two LEDs light up simultaneously.</div>
<p>&#8211; Combination device of LAN tester and multimeter<br />
&#8211; LCD<br />
&#8211; Checks Lankabel and patch fields<br />
&#8211; Continuity test and diode test possible<br />
&#8211; Overload indicator<br />
&#8211; Short circuit display</p></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu">
<div id="pgbody">
<div id="main-container" class="container">
<div class="row">
<div class="col-sm-12">
<div class="ibox">
<div class="sd-itemdetail sd-itemdetail-0">
<div id="itemdetail">
<div class="no-panel no-panel-smart no-artikelkarte-panel">
<div class="no-panel-body">
<div class="tabgroup tabgroup-itemdetail">
<div class="tab-content">
<div id="tab-customdata3" class="tab-pane fade in  active">
<div class="usertext">
<div class="usertext">
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measuring function</span></td>
<td valign="top"><strong><span>AC</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>750V</span></td>
<td valign="top"><span>1V</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (1% from + 5 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring function         </span></td>
<td valign="top"><strong><span>DC</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 V</span></td>
<td valign="top"><span>1 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>1000V</span></td>
<td valign="top"><span>1V</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (0.5% of v / m + 3Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring function</span></td>
<td valign="top"><strong><span>Resistance</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>400 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 kΩ</span></td>
<td valign="top"><span>1 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40 kΩ</span></td>
<td valign="top"><span>10 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>400 kΩ</span></td>
<td valign="top"><span>100 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>4 MΩ</span></td>
<td valign="top"><span>1 kΩ</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (1.2% from + 3 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><strong><span>Resistance</span></strong></td>
<td valign="top"><strong><span>Resolution</span></strong></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>40 MΩ</span></td>
<td valign="top"><span>10 kΩ</span></td>
</tr>
<tr>
<td valign="top"><span>Accuracy</span></td>
<td colspan="2" valign="top"><span>± (2% from + 4 Dgt)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td colspan="2" valign="top"><span>400 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Alarm</span></td>
<td colspan="2" valign="top"><span>Measured value &lt;25Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Display</span></td>
<td colspan="2" valign="top"><span>LED bargraph for LAN testers</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>LC display for multimeter functions</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply   </span></td>
<td colspan="2" valign="top"><span>LAN tester: 1 x 9V 6F22 battery</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Multimeter: 2 x 1.5V AAA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td colspan="2" valign="top"><span>Handset: 165 x 82 x 42 mm / 6.5 x 3.2 x 1.7 in   </span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Remote unit: 75 x 30 x 25 mm / 3 x 1.2 x 1 in </span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td colspan="2" valign="top"><span>Handset: 240 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Remote unit: 30 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Electric security</span></td>
<td colspan="2" valign="top"><span>CAT III 600V</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="boxfoot"></div>
</div>
</div>
</div>
</div>
<footer id="footer-area">
<div id="bxfooter" class="box box_plain box-footer">
<div class="boxhead"></div>
<div class="ibox">
<div class="footer-links">
<div class="container">
<div class="col-md-6 col-sm-6">
<div id="bxmenu_custom1" class="box box_plain box-menu_custom1">
<div class="boxhead"></div>
<div class="ibox">
<div id="Custom1" class="menu"></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</footer>
<p>The post <a href="https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lt-15/">Voltmeter PCE-LT 15</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.amet.co.th/shop/voltmeter-dmm/voltmeter-pce-lt-15/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">19194</post-id>	</item>
	</channel>
</rss>
