<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Cable Fault Meter - Amet Co.,Ltd</title>
	<atom:link href="https://www.amet.co.th/product-category/cable-fault-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.amet.co.th/product-category/cable-fault-meter/</link>
	<description>เครื่องวัดความสั่นสะเทือน เครื่องวัดในอุตสาหกรรม</description>
	<lastBuildDate>Mon, 20 Feb 2023 05:19:53 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.13</generator>

<image>
	<url>https://www.amet.co.th/wp-content/uploads/2019/06/Ametlogo-100x100.jpg</url>
	<title>Cable Fault Meter - Amet Co.,Ltd</title>
	<link>https://www.amet.co.th/product-category/cable-fault-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190110130</site>	<item>
		<title>Cable Fault Meter PCE-CL 10</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-10/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:58:53 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10478</guid>

					<description><![CDATA[<p><strong>PCE-CL 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-10/">Cable Fault Meter PCE-CL 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-CL 10 is a cable fault meter that uses the conductive method to detect metal pipes or pipe tracer wires. With PCE-CL 10, you also can locate power cables, lines, circuits, short circuits and ground points, as well as test protective tubing and coaxial cables. To perform these functions, it is not necessary to disconnect the power. Location can be identified in floors, ceilings, walls and the ground, even behind concrete and brick.</p>
<p>PCE-CL 10 features a detection system that is composed of a signal generator for active lines and a transmitter or receiver for cables without current. The signal generator feeds high-frequency electromagnetic signals through the lines being tested. At the end of the cable, these signals are converted into acoustic or optical signals by the receiver.<br />
&#8211; Finds hidden, concealed, buried or underground metal pipes or pipe tracer wires found in floors, ceilings, walls, concrete and brick<br />
&#8211; Locates power cables, lines, circuits, short circuits and ground points<br />
&#8211; Tests protective tubing and coaxial cables<br />
&#8211; Uses the conductive method</p>
<table width="600">
<tbody>
<tr>
<td colspan="2"><b><strong>Technical specifications</strong></b></td>
</tr>
<tr>
<td width="293">Operating temperature / humidity</td>
<td width="300">0 &#8230; +40 ºC or +32 &#8230; +104 ºF / max. 80% rh</td>
</tr>
<tr>
<td width="293">Storing temperature / humidity</td>
<td width="300">-20 &#8230; + 60 ºC or -4 &#8230; +140 ºF  / max. 80% rh</td>
</tr>
<tr>
<td colspan="2"><b><strong><br />
Receiver</strong></b></td>
</tr>
<tr>
<td width="293">Auto shut-off</td>
<td width="300">Approx. 5 min.</td>
</tr>
<tr>
<td width="293">Absorbed power</td>
<td width="300">Max. 40 mA</td>
</tr>
<tr>
<td width="293">Display</td>
<td width="300">LCD with bar graph</td>
</tr>
<tr>
<td width="293">Battery</td>
<td width="300">9 V</td>
</tr>
<tr>
<td width="293">Dimensions</td>
<td width="300">192 x 61 x  37 mm / 7.56 x 2.40 x 1.46 in</td>
</tr>
<tr>
<td width="293">Weight</td>
<td width="300">Approx. 180 g / 0.40 lb</td>
</tr>
<tr>
<td colspan="2"><b><strong><br />
Signal generator</strong></b></td>
</tr>
<tr>
<td width="293">Maximum voltage</td>
<td width="300">400 V AC (0-60 Hz<br />
400 V DC)</td>
</tr>
<tr>
<td width="293">Transmitting frequency</td>
<td width="300">125 kHz</td>
</tr>
<tr>
<td width="293">Display</td>
<td width="300">LCD</td>
</tr>
<tr>
<td width="293">Auto shut-off</td>
<td width="300">Approx. 1 hour</td>
</tr>
<tr>
<td width="293">Absorbed power</td>
<td width="300">Max. 18 mA</td>
</tr>
<tr>
<td width="293">Battery</td>
<td width="300">9 V</td>
</tr>
<tr>
<td width="293">Fuses</td>
<td width="300">Flink,  0.5 A  / 500 V, 6.3 x 32 mm</td>
</tr>
<tr>
<td width="293">Overvoltage category</td>
<td width="300">CAT III / 300 V</td>
</tr>
<tr>
<td width="293">Dimensions</td>
<td width="300">130 x 69 x  32 mm / 5.12 x 2.72 x 1.26 in</td>
</tr>
<tr>
<td width="293">Weight</td>
<td width="300">Approx. 130 g / 0.30 lb</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-10/">Cable Fault Meter PCE-CL 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10478</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-CL 20</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-20/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:56:23 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10474</guid>

					<description><![CDATA[<p><strong>PCE-CL 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-20/">Cable Fault Meter PCE-CL 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-CL 20 is a cable fault meter or locator used to detect live and voltage-free electrical wires. This cable detector also can be used to locate metallic and non-metallic gas or water pipes, identify short circuits, and follow lines inside walls or under flooring.</p>
<p>The PCE-CL 20 wire tracer consists of two individual units: a signal generator (or transmitter) and a receiver. Both units are equipped with bright LED lights for use in dark and dimly lit spaces. In addition, the receiver has a backlit LCD screen.<br />
&#8211; Output signal: 125 kHz<br />
&#8211; Compatible with one- or two-pole circuits<br />
&#8211; Automatic, manual and UAC measuring modes<br />
&#8211; Locates hidden cables, wires or pipes<br />
&#8211; Helps identify short circuits and fuses<br />
&#8211; Includes alligator clips, measuring tips, test leads and ground rod</p>
<table class="TechSpecs">
<tbody>
<tr>
<td colspan="2"><strong>Technical specification</strong></td>
</tr>
<tr>
<td class="data" width="50%">Output</td>
<td class="data" width="50%">125 kHz</td>
</tr>
<tr>
<td class="data" width="50%">External Voltage Identification Area</td>
<td class="data" width="50%">DC 12 &#8230; 400 V ± 2.5%; AC 12 &#8230; 400 V (50 &#8230; 60 Hz) ± 2.5%</td>
</tr>
<tr>
<td class="data" width="50%">Display</td>
<td class="data" width="50%">LCD</td>
</tr>
<tr>
<td class="data" width="50%">Maximum Voltage</td>
<td class="data" width="50%">Max. 400 V AC / DC</td>
</tr>
<tr>
<td class="data" width="50%">Overvoltage Category</td>
<td class="data" width="50%">CAT III 300 V</td>
</tr>
<tr>
<td class="data" width="50%">Pollution Degree</td>
<td class="data" width="50%">2</td>
</tr>
<tr>
<td class="data" width="50%">Power Supply</td>
<td class="data" width="50%">9 V battery</td>
</tr>
<tr>
<td class="data" width="50%">Power Consumption (minimum voltage)</td>
<td class="data" width="50%">approximately 31 mA</td>
</tr>
<tr>
<td class="data" width="50%">Power Consumption (maximum voltage)</td>
<td class="data" width="50%">about 115 mA</td>
</tr>
<tr>
<td class="data" width="50%">Backup</td>
<td class="data" width="50%">F 0.5 A 500 V, 6.3 mm x 32 mm / 0.24 x 1.25in</td>
</tr>
<tr>
<td class="data" width="50%">Operating Conditions</td>
<td class="data" width="50%">0 &#8230; +40 ° C/+32 &#8230; +72 ° F<br />
rel. Humidity &lt;80%</td>
</tr>
<tr>
<td class="data" width="50%">Storage Conditions</td>
<td class="data" width="50%">-20 &#8230; +60 °C /+12 &#8230; +92 ° F<br />
rel. Humidity &lt;80%</td>
</tr>
<tr>
<td class="data" width="50%">Dimensions</td>
<td class="data" width="50%">190 mm x 89 mm x 42.5 mm<br />
7.48 in x 3.50 in x 1.67 in</td>
</tr>
<tr>
<td class="data" width="50%">Weight</td>
<td class="data" width="50%">420 g / 0.92 lbs (including battery)</td>
</tr>
<tr>
<td colspan="2"><strong><br />
Technical specification for cable detector (receiver)</strong></td>
</tr>
<tr>
<td class="data" width="50%">Detection Depth</td>
<td class="data" width="50%">depends on material and the particular application</td>
</tr>
<tr>
<td class="data" width="50%">Pole Application</td>
<td class="data" width="50%">about 0 &#8230; 2 m / 0 &#8230; 6.56 ft</td>
</tr>
<tr>
<td class="data" width="50%">Bipolar Application</td>
<td class="data" width="50%">about 0 &#8230; 0.5 m / 0 &#8230; 1.64 ft</td>
</tr>
<tr>
<td class="data" width="50%">Simple Loop</td>
<td class="data" width="50%">Up to 2.5 m / 8.2021 ft</td>
</tr>
<tr>
<td class="data" width="50%">Grid Voltage Detection</td>
<td class="data" width="50%">about 0 &#8230; 0.4 m / 0 &#8230; 1.31 ft</td>
</tr>
<tr>
<td class="data" width="50%">Display</td>
<td class="data" width="50%">LCD</td>
</tr>
<tr>
<td class="data" width="50%">Power Supply</td>
<td class="data" width="50%">6 x 1.5V AAA batteries</td>
</tr>
<tr>
<td class="data" width="50%">Power Consumption (minimum voltage)</td>
<td class="data" width="50%">about 32 mA</td>
</tr>
<tr>
<td class="data" width="50%">Power Consumption (maximum voltage)</td>
<td class="data" width="50%">approximately 89 mA</td>
</tr>
<tr>
<td class="data" width="50%">Environmental Conditions</td>
<td class="data" width="50%">0 &#8230; +40 °C / +32 &#8230; +72 ° F<br />
rel. Humidity &lt;80%</td>
</tr>
<tr>
<td class="data" width="50%">Storage Conditions</td>
<td class="data" width="50%">-20 &#8230; +60 °C / +12 &#8230; +92 ° F<br />
rel. Humidity &lt;80%</td>
</tr>
<tr>
<td class="data" width="50%">Dimensions</td>
<td class="data" width="50%">241.5 mm x 78 mm x 38.5 mm<br />
9.5 in x 3.07 in x 1.51 in</td>
</tr>
<tr>
<td class="data" width="50%">Weight</td>
<td class="data" width="50%">350 g / 0.77 lbs (including batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-cl-20/">Cable Fault Meter PCE-CL 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10474</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-CLT 10</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-clt-10/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:51:07 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10469</guid>

					<description><![CDATA[<p><strong>PCE-CLT 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-clt-10/">Cable Fault Meter PCE-CLT 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center"><strong>Cable Fault Meter PCE-CLT 10</strong></p>
<div style="text-align: center"><strong>Cable length measuring device with high measuring accuracy and fast measuring results / 2.4&#8243; TFT display / Measuring range up to 3000 meters (9842.5 ft) / 20 preset cable types / Compact design / additional storage option for up to 99 cable types</strong></div>
<div>
<p>The cable length measuring device PCE-CLT 10 is a multifunctional device which enables high accuracy and fast measurement results. If used appropriately, the cable length meter can be used to measure cables that have already been installed and are still to be installed. The cable length measuring device can be used to determine cable lengths of up to three kilometers. This is done by a time domain reflectometer. On the cable length measuring device itself, 20 standard types of cables are pre-stored and further storage of up to 99 cable types is also possible on the device itself. The stored data can be viewed directly on the device and can be used as required. Due to the built-in technology comparatively short cables can already be tested. The minimum length that a cable must have, which should be examined with the Cable Length Gauge.</p>
<p>To increase battery life, the device automatically shuts off after 10 minutes of inactivity. This automatic shutdown can be set individually by the user at intervals of 10 minutes. In addition to the automatic shutdown, the device offers a bright TFT display, which makes a quick reading of the measurement results also possible due to its backlighting.</p>
</div>
<p>&#8211; High measuring accuracy up to 3000 m / 9842.5 ft<br />
&#8211; Results after a short measuring time<br />
&#8211; 2.4&#8243; TFT color display<br />
&#8211; Automatic shutdown adjustable<br />
&#8211; Illuminated TFT display<br />
&#8211; 20 pre-set cable types</p>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Measuring range cable length</span></td>
<td valign="top"><span>Depending on the propagation speed of the tested cables </span><br />
<span>5 &#8230; 3000 m / 16.4 &#8230; 9842.5 ft with shortening factor ≤99.9% </span><br />
<span>5 &#8230; 2400 m / 16.4 &#8230; 7874.0 ft with shortening factor ≤80.0% </span><br />
<span>5 &#8230; 2000 m / 16.4 &#8230; 6561.7 ft with shortening factor ≤66.0% </span><br />
<span>5 &#8230; 1500 m / 16.4 &#8230; 4921.3 ft with shortening factor ≤50.0%</span></td>
</tr>
<tr>
<td valign="top"><span>Measurement units</span></td>
<td valign="top"><span>m, ft</span></td>
</tr>
<tr>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>0.1 m</span></td>
</tr>
<tr>
<td valign="top"><span>Measuring principle</span></td>
<td valign="top"><span>Time domain reflectometer</span></td>
</tr>
<tr>
<td valign="top"><span>Selection area</span></td>
<td valign="top"><span>Automatic control range</span></td>
</tr>
<tr>
<td valign="top"><span>Measurement accuracy</span></td>
<td valign="top"><span>± [2% of reading ± 0.2 m] &lt;100 m </span><br />
<span>± [2% of reading ± 0.5 m] ≤100 m</span></td>
</tr>
<tr>
<td valign="top"><span>Impedance selector</span></td>
<td valign="top"><span>Automatic output of the impedance control</span></td>
</tr>
<tr>
<td valign="top"><span>Shortening factor / propagation speed  </span></td>
<td valign="top"><span>Adjustable from 1.0 &#8230; 99.9%</span></td>
</tr>
<tr>
<td valign="top"><span>Cable types</span></td>
<td valign="top"><span>20 standard cables</span></td>
</tr>
<tr>
<td valign="top"><span>Memory</span></td>
<td valign="top"><span>99 memory slots for individual cables</span></td>
</tr>
<tr>
<td valign="top"><span>Connector type</span></td>
<td valign="top"><span>BNC, RJ45</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td valign="top"><span>2 x 1.5V AA battery</span></td>
</tr>
<tr>
<td valign="top"><span>Battery status indicator</span></td>
<td valign="top"><span>Yes</span></td>
</tr>
<tr>
<td valign="top"><span>Automatic shutdown</span></td>
<td valign="top"><span>Adjustable between 10 and 60 minutes</span></td>
</tr>
<tr>
<td valign="top"><span>Menu languages</span></td>
<td valign="top"><span>German, English</span></td>
</tr>
<tr>
<td valign="top"><span>Operating temperatur</span></td>
<td valign="top"><span>0 &#8230; 40°C / 32 &#8230; 104°F</span></td>
</tr>
<tr>
<td valign="top"><span>Storage temperature</span></td>
<td valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122°F</span></td>
</tr>
<tr>
<td valign="top"><span>Relative humidity</span></td>
<td valign="top"><span>0 &#8230; 80% rel. humidity</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-clt-10/">Cable Fault Meter PCE-CLT 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10469</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-LT 12</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-12/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:40:17 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10460</guid>

					<description><![CDATA[<p>Cable fault meter PCE-LT 12 Voltage tester with many me [...]</p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-12/">Cable Fault Meter PCE-LT 12</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center;"><strong>Cable fault meter</strong><strong> PCE-LT 12<br />
Voltage tester with many measuring functions / For electricians and IT employees / Analysis of network connection cables / Telephone connection test / Voltage and current measurement / NCV / backlight</strong></div>
<div></div>
<div>The voltage tester is a versatile measuring instrument. In addition to the standard voltage and current measurements, the voltage tester also has a network analysis. With this network analysis, the voltage tester can be used to check, for example, LAN connections for their correct wiring and function. Telephone connections can also be checked for their function with this voltage tester. If cables can not be found again, the voltage tester also helps here.</div>
<div></div>
<div>Thanks to the cable finder function of the voltage tester, the operator can find the required cable in no time at all. To do this, the voltage tester must be connected to the connection of a cable. The voltage tester now acts as a transmitter. With the supplied receiver you can now easily find the desired cable in, for example, a wiring harness or behind walls with the voltage tester.</div>
<div></div>
<div>To check whether a voltage is applied to a cable, the voltage tester has an NCV (Not Connected Voltage) function. With this function, the voltage tester must only be held to the line. Both acoustically and visually, the voltage tester signals the operator that a voltage is applied to the line. Thanks to this contactless measuring function, the voltage tester reduces accidents at work due to electric shock.</div>
<div></div>
<div>&#8211; Extensive network connection testing<br />
&#8211; Telephone connection examination<br />
&#8211; Acoustic cable finder function<br />
&#8211; Robust housing for mobile use<br />
&#8211; Voltage, current, resistance measurement<br />
&#8211; Contactless voltage detection</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>AC</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top" width="86"><strong>Resolution</strong></td>
<td colspan="2" valign="top" width="244"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">200 mV</td>
<td valign="top">0.1 mV</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20V</td>
<td valign="top">0.01V</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top">200V</td>
<td valign="top">0.1V</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top">750V</td>
<td valign="top">1V</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Maximum input voltage: 750V AC</td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 &#8230; 400 Hz</td>
</tr>
<tr>
<td colspan="4" valign="top">Conversion RMS</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>DC</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">200 mV</td>
<td valign="top">0.1 mV</td>
<td colspan="2" valign="top">± (0.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2V</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">± (0.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20V</td>
<td valign="top">0.01V</td>
<td colspan="2" valign="top">± (0.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">200V</td>
<td valign="top">0.1V</td>
<td colspan="2" valign="top">± (0.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">1000V</td>
<td valign="top">1V</td>
<td colspan="2" valign="top">± (0.8% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Maximum input voltage: 1000V DC</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Alternating current</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">200 μA</td>
<td valign="top">0.1 μA</td>
<td colspan="2" valign="top">± (1.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2000 μA</td>
<td valign="top">1 μA</td>
<td colspan="2" valign="top">± (1.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20-mA</td>
<td valign="top">0.01-mA</td>
<td colspan="2" valign="top">± (1.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">200-mA</td>
<td valign="top">0.1-mA</td>
<td colspan="2" valign="top">± (1.5% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2 A</td>
<td valign="top">0.001 A</td>
<td colspan="2" valign="top">± (3.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20 A</td>
<td valign="top">0.01A</td>
<td colspan="2" valign="top">± (3.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overload protection at μA, mA: 200-mA / 1000V fuse</td>
</tr>
<tr>
<td colspan="4" valign="top">Overload protection at A: 10 A / 500V fuse</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current μA: 2000 μA</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current mA: 200-mA</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current A: 10 A.</td>
</tr>
<tr>
<td colspan="4" valign="top">Frequency range: 40 &#8230; 400 Hz</td>
</tr>
<tr>
<td colspan="4" valign="top">Conversion RMS</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Direct current</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">200 μA</td>
<td valign="top">0.1 μA</td>
<td colspan="2" valign="top">± (1.2% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2000 μA</td>
<td valign="top">1 μA</td>
<td colspan="2" valign="top">± (1.2% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20-mA</td>
<td valign="top">0.01-mA</td>
<td colspan="2" valign="top">± (1.2% + 5 digits)</td>
</tr>
<tr>
<td valign="top">200-mA</td>
<td valign="top">0.1-mA</td>
<td colspan="2" valign="top">± (1.2% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2 A</td>
<td valign="top">0.001 A</td>
<td colspan="2" valign="top">± (2.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20 A</td>
<td valign="top">0.01A</td>
<td colspan="2" valign="top">± (2.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td colspan="4" valign="top">Overload protection at μA, mA: 200-mA / 1000V fuse</td>
</tr>
<tr>
<td colspan="4" valign="top">Overload protection at A: 10 A / 500V fuse</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current μA: 2000 μA</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current mA: 200-mA</td>
</tr>
<tr>
<td colspan="4" valign="top">maximum input current A: 10 A.</td>
</tr>
<tr>
<td colspan="4" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring function</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Resistance</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">200 Ω</td>
<td valign="top">0.1 Ω</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2 kΩ</td>
<td valign="top">0.001 kΩ</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20 kΩ</td>
<td valign="top">0.01 kΩ</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">200 kΩ</td>
<td valign="top">0.1 kΩ</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">2 MΩ</td>
<td valign="top">0.001 MΩ</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top">20 MΩ</td>
<td valign="top">0.01 MΩ</td>
<td colspan="2" valign="top">± (1.0% + 5 digits)</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Diode measurement</strong></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">Indicates the forward voltage</td>
<td valign="top">1 mV</td>
<td colspan="2" valign="top">&#8211;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Continuity test</strong></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Measuring range</strong></td>
<td valign="top"><strong>Resolution</strong></td>
<td colspan="2" valign="top"><strong>Accuracy</strong></td>
</tr>
<tr>
<td valign="top">Beep at &lt;70 Ω</td>
<td valign="top">0.1 Ω</td>
<td colspan="2" valign="top">&#8211;</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong>Other specifications</strong></td>
<td colspan="3" valign="top"></td>
</tr>
<tr>
<td valign="top">Range selection</td>
<td colspan="3" valign="top">Automatically and manually</td>
</tr>
<tr>
<td valign="top">Measurement with receiver</td>
<td colspan="3" valign="top">Detecting cable bridges, detecting cable runs</td>
</tr>
<tr>
<td valign="top">Measurement with network function</td>
<td colspan="3" valign="top">Detection of open and closed circuits,</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">wrong connection, &#8220;split pair&#8221;, &#8220;reverse&#8221; connection,</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">Network integration test, screening test</td>
</tr>
<tr>
<td valign="top">Further measurement function</td>
<td colspan="3" valign="top">&#8220;NCV&#8221; detection, telephone connection testing</td>
</tr>
<tr>
<td valign="top">Display</td>
<td colspan="3" valign="top">LCD, 1999 digits</td>
</tr>
<tr>
<td valign="top">Overload indicator</td>
<td colspan="3" valign="top">&#8220;OIL&#8221;</td>
</tr>
<tr>
<td valign="top">Automatic shutdown</td>
<td colspan="3" valign="top">After 15 minutes of inactivity</td>
</tr>
<tr>
<td valign="top">Fuses</td>
<td colspan="3" valign="top">F10A / 500V, F200mA / 1000A</td>
</tr>
<tr>
<td valign="top">Battery indicator</td>
<td colspan="3" valign="top">Display when battery is discharged</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td colspan="3" valign="top">9V block battery</td>
</tr>
<tr>
<td valign="top">Operating conditions</td>
<td colspan="3" valign="top">0 &#8230; 40°C / 32 &#8230; 104°F</td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="3" valign="top">-10 &#8230; 50°C / 14 &#8230; 122°F</td>
</tr>
<tr>
<td valign="top">Dimensions</td>
<td colspan="3" valign="top">195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td colspan="3" valign="top">Approx. 400 g / &lt; 1 lb (with batteries)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-12/">Cable Fault Meter PCE-LT 12</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10460</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-180 CBN</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-180-cbn/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:37:35 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10458</guid>

					<description><![CDATA[<p><strong>PCE-180 CBN</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-180-cbn/">Cable Fault Meter PCE-180 CBN</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-180 CBN is a handheld, portable, battery-powered wire tracer or cable locator that consists of an amplifier probe and acoustic signal or tone generator. This locating device is designed to detect wires or cables hidden behind walls or insulation.<br />
&#8211; Uses an acoustic signal to detect wires and cables, including network and coaxial cables<br />
&#8211; Features a 3-position toggle switch (and 3-color LED) for line polarity, continuity and voltage testing<br />
&#8211; Comes with red and black test leads with alligator clips<br />
&#8211; Has a standard 4-conductor modular cord and plug<br />
&#8211; Battery powered<br />
&#8211; Recessed on / off button prevents accidental activation and battery drain<br />
&#8211; Adjustable volume and selection of either single solid tone or dual alternating tone<br />
&#8211; Compatible with other signal or tone generators used to detect wires or cables<br />
&#8211; Contains built-in headphone jack</p>
<p><strong>Technical specifications</strong><br />
Detection method: Acoustic signal<br />
Tones: Pulsing or continuous<br />
Connections: RJ-11, alligator clips and headphone jack<br />
Power supply: 2 x 9 V batteries<br />
Certifications: CE, IEC / EN 61010-1:01<br />
Operating conditions: 0 &#8230; +50 °C / +32 &#8230; +122 °F and 5 &#8230; 95% rh<br />
Dimensions: 60 x 65 x 30 mm / 2.36 x 2.56 x 1.18&#8243; signal generator and 245 x 60 x 30 mm / 9.65 x 2.36 x 1.18&#8243; amplifier probe<br />
Weight: 120 g / 0.26 lb signal generator and 140 g / 0.31 lb amplifier probe</p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-180-cbn/">Cable Fault Meter PCE-180 CBN</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10458</post-id>	</item>
		<item>
		<title>PoE tester / cable tester PCE-POE 10</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/poe-tester-cable-tester-pce-poe-10/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:35:49 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10456</guid>

					<description><![CDATA[<p><strong>PCE-POE 10</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/poe-tester-cable-tester-pce-poe-10/">PoE tester / cable tester PCE-POE 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div>
<div style="text-align: center"><strong>PoE tester with three test functions / transmitter and remote unit / LCD / RJ45 connections </strong><strong>/ flashlight function / PoE standard detection</strong></div>
<div></div>
<div>The PoE tester has 3 test modes. This enables the PoE tester to perform a continuity test of the Ethernet cables, to identify the PoE types and to measure the PoE performance. This makes the PoE tester an ideal tool for every network technician and installer of Ethernet cables.</p>
<p>The PoE tester consists of a transmitter / main unit and a remote unit. In the continuity test mode, the PoE tester can also determine whether all wires of the Ethernet cable are connected correctly. The PoE tester can also measure the performance of connected PoE devices. This is used for troubleshooting and detection in the network.</p></div>
<div></div>
</div>
</div>
<div>&#8211; continuity test</div>
<div>&#8211; Cable test</div>
<div>&#8211; voltage measurement</div>
<div>&#8211; Detection of the PoE standard</div>
<div>&#8211; PoE power measurement</div>
<div>&#8211; LCD with graphics menu</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong>Continuity test</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">cable types</td>
<td valign="top">STP, UTP</td>
</tr>
<tr>
<td valign="top">Maximum cable length</td>
<td valign="top">600 m</td>
</tr>
<tr>
<td valign="top">Connection type</td>
<td valign="top">Sender -&gt; remote unit</td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top">Sender -&gt; router / switch</td>
</tr>
<tr>
<td valign="top"><strong>PoE exam</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Measuring range</td>
<td valign="top">5 &#8230; 60 V</td>
</tr>
<tr>
<td valign="top">Standard recognition</td>
<td valign="top">802.3af / at (standard / non-standard)</td>
</tr>
<tr>
<td valign="top">power</td>
<td valign="top">0 &#8230; 18 W.</td>
</tr>
<tr>
<td valign="top"><strong>Power function</strong></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top">Voltage measuring range</td>
<td valign="top">0 &#8230; 60 V</td>
</tr>
<tr>
<td valign="top">Current measuring range</td>
<td valign="top">0 &#8230; 3 A</td>
</tr>
<tr>
<td valign="top">Power measurement range</td>
<td valign="top">0 &#8230; 180 W.</td>
</tr>
<tr>
<td valign="top">Entrance protection</td>
<td valign="top">48 V / 5 mA DC</td>
</tr>
<tr>
<td valign="top">Max. Operating current</td>
<td valign="top">80 mA</td>
</tr>
<tr>
<td valign="top">Loop length</td>
<td valign="top">10 m, 100 m, 1000 m</td>
</tr>
<tr>
<td valign="top">Power supply</td>
<td valign="top">3 x 1.5 V AAA batteries</td>
</tr>
<tr>
<td valign="top">connections</td>
<td valign="top">RJ45</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/poe-tester-cable-tester-pce-poe-10/">PoE tester / cable tester PCE-POE 10</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10456</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-191 CB</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-191-cb/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 07:32:31 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10414</guid>

					<description><![CDATA[<p><strong>PCE-191 CB</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-191-cb/">Cable Fault Meter PCE-191 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>PCE-191 CB is a handheld, portable wire tracer, cable detector or cable fault meter used for locating wires and cables hidden behind walls and insulation. Comprised of a signal transmitter and receiver, this easy-to-use cable locating device emits an acoustic alarm.<br />
&#8211; Detects live cables and wires (it is not necessary to remove the fuse)<br />
&#8211; Compact design<br />
&#8211; CE, IEC / EN 61010-1:01 safety ratings</p>
<table>
<tbody>
<tr>
<td colspan="2"><strong>Technical specifications</strong></td>
</tr>
<tr>
<td>Detection method</td>
<td>Acoustic signal</td>
</tr>
<tr>
<td>Power range</td>
<td>220 to 240 V AC</td>
</tr>
<tr>
<td>Frequency range</td>
<td>50 / 60 Hz</td>
</tr>
<tr>
<td>Power supply</td>
<td>Transmitter: Electric power<br />
Receiver: 9 V battery</td>
</tr>
<tr>
<td>Weight</td>
<td>300 g / 0.67 lb</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-191-cb/">Cable Fault Meter PCE-191 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10414</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-170 CB</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-170-cb/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 04:53:13 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10411</guid>

					<description><![CDATA[<p><strong>PCE-170 CB</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-170-cb/">Cable Fault Meter PCE-170 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Cable fault meter</strong><strong> PCE-170 CB<br />
Locating device with a network cable finder function / Cable finder adjustable intensity / Suitable for mobile applications / Continuity check / RJ 45, RJ 11, BNC, coaxial cable</strong></div>
<div></div>
<div>The locating device is a universally applicable measuring device. With this locating device, for example, RJ11 ISDN telephone lines can be checked for their function. For this purpose it is sufficient to connect the RJ 11 plug of the locating device to the telephone socket. The locator instantly shows the operator if this port is connected. A ringing test is also possible with the locating device. For this, the connection must be called via an external telephone. Another function of the locating device is the testing of LAN connections in sockets. In this test method, the locating device indicates a short circuit, incorrect wiring, &#8220;reversed&#8221; or &#8220;split pairs&#8221;.</div>
<div></div>
<div>Another special feature of the locating device is the storage option. All additional modules of the locating device can be safely plugged into the main module. This prevents the loss of a module at the locating device. Even the exposed test leads of the locating device can be stored safely. Thanks to this stowage possibility, the locating device can be easily transported.</div>
<p>&#8211; Network cable continuity test<br />
&#8211; Intensity of the receiver adjustable<br />
&#8211; Cable protection cap for safe transport<br />
&#8211; All modules stowed in the transmitter<br />
&#8211; ISDN connection test<br />
&#8211; Continuity test with cables</p>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top" width="0"><span>Test functions</span></td>
<td valign="top" width="0"><span>Network Cable Testing</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Coaxial cable test</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Network cable Finder</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Continuity test</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Telephone line test</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Continuity test</span></td>
<td valign="top"><span>Continuity is signaled up to 10 Ω</span></td>
</tr>
<tr>
<td valign="top"><span>Input voltage</span></td>
<td valign="top"><span>Max. 24V</span></td>
</tr>
<tr>
<td valign="top"><span>Connections</span></td>
<td valign="top"><span>RJ45, BNC, RJ11,</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Crocodile clips red and black</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply (transmitter)         </span></td>
<td valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply (receiver)</span></td>
<td valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, &lt; 80% rh</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td valign="top"><span>210 x 80 x 50 mm / 8.3 x 3.1 x 2 in</span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td valign="top"><span>About 416 g / &lt; 1 lb</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-170-cb/">Cable Fault Meter PCE-170 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10411</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-LT 20</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-20/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 04:51:13 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10407</guid>

					<description><![CDATA[<p><strong>PCE-LT 20</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-20/">Cable Fault Meter PCE-LT 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Cable fault meter</strong><strong> PCE-LT 20<br />
Cable tester for network cables, coaxial cables, single cores, telephone lines etc. / Set consisting of cable tester and remote unit / For assignment of wires and cable search</strong></div>
<div></div>
<div>The cable tester PCE-LT 20 is used to determine the correct assignment of wire pairs in network cables. Furthermore, the cable tester can be used to locate lines and determine the connection between cables. The cable tester is a universally applicable test device for the electrician and service technician. The cable tester PCE-LT 20 consists of a main unit and a remote display. The remote unit is used to control the assignment of the wire pairs on a remote network socket.</div>
<div></div>
<div>Furthermore, the remote unit of the cable tester is also used as a receiver for the locating signal for cable search. Using the USB sockets, the connection can be checked by a USB cable using the cable tester. The cable tester PCE-LT 20 can also be used to check analog telephone systems. For this purpose, the main unit is simply connected to a telephone jack instead of a terminal. Two LEDs on the cable tester signal an incoming call.</div>
<div></div>
<div>&#8211; Automatic / manual test of lan cables<br />
&#8211; Main and remote unit<br />
&#8211; Testing of coaxial cables, single cores, etc.<br />
&#8211; Easiest operation<br />
&#8211; Cable location up to 50 cm depth<br />
&#8211; For testing of analog telephone systems</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><span>Display</span></td>
<td valign="top"><span>LED bargraph displays</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Multicolor LEDs</span></td>
</tr>
<tr>
<td valign="top"><span>Sound</span></td>
<td valign="top"><span>Square-wave signal 1 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Over voltage protection </span></td>
<td valign="top"><span>80V DC</span></td>
</tr>
<tr>
<td valign="top"><span>Tones</span></td>
<td valign="top"><span>Fast / slow pulse</span></td>
</tr>
<tr>
<td valign="top"><span>Remote unit range<br />
</span></td>
<td valign="top"><span>1 Hz &#8230; 12 kHz</span></td>
</tr>
<tr>
<td valign="top"><span>Locating depth</span></td>
<td valign="top"><span>Max. 50 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Operating conditions</span></td>
<td valign="top"><span>0 &#8230; 40°C / 32 &#8230; 104°F, max. 80% rh</span></td>
</tr>
<tr>
<td valign="top"><span>Storage conditions</span></td>
<td valign="top"><span>-10 &#8230; 50°C / 14 &#8230; 122°F, max. 80% rh</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply</span></td>
<td valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Dimensions</span></td>
<td valign="top"><span>Main unit: 263 x 55 x 37.3 mm / 10.4 x 2.2 x 1.5 in   </span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Remote unit: 180 x 82 x 43.8 mm / 7.1 x 3.2 x 1.7 in </span></td>
</tr>
<tr>
<td valign="top"><span>Weight</span></td>
<td valign="top"><span>Main unit: 210 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>Remote unit: 280 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Standards</span></td>
<td valign="top"><span>EN61326-1</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>IEC 61000-4-2</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>IEC 61000-4-3</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>IEC 61000-4-8</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"><span>CISPR11</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-lt-20/">Cable Fault Meter PCE-LT 20</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">10407</post-id>	</item>
		<item>
		<title>Cable Fault Meter PCE-186 CB</title>
		<link>https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-186-cb/</link>
		
		<dc:creator><![CDATA[Admin Amet]]></dc:creator>
		<pubDate>Wed, 20 Jan 2021 04:49:26 +0000</pubDate>
				<guid isPermaLink="false">https://amet.co.th/?post_type=product&#038;p=10401</guid>

					<description><![CDATA[<p><strong>PCE-186 CB</strong></p>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-186-cb/">Cable Fault Meter PCE-186 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="text-align: center"><strong>Cable fault meter PCE-186 CB<br />
Cable finder with voltage tester / Non-conducting probe tip / Headphone jack / RJ-11 Plug with crocodile clamps / For line break detection / For non-live cables / Transport bag </strong></div>
<div></div>
<div>The cable finder PCE-186 CB consists of a transmitter and a receiver. The transmitter of the line finder has many functions. For example, the line finder can be used to find wires in walls or break cables. Another function of the line finder is the testing of telephone sockets. To do this, the RJ-11 connector must be plugged into the telephone socket to be tested. The transmitter of the line finder signals an incoming call based on the LEDs. This feature does not require a phone for verification.</div>
<div></div>
<div>In addition to these functions, the line finder has a multimeter function. This allows AC voltages and DC voltages up to 1000 VDC to be measured. Furthermore, resistance measurements and continuity measurements are possible. Because of this variety of functions, the line finder is an optimal helper for maintenance and repair work on cables.</div>
<div></div>
<div>&#8211; Voltage measurement AC / DC<br />
&#8211; For detection of line interruptions<br />
&#8211; Non-conductive probe tip<br />
&#8211; Sensitivity adjustment<br />
&#8211; Transport bag<br />
&#8211; Cable tracking in walls and cable duct<br />
&#8211; Different beeps<br />
&#8211; Resistance measurement</div>
<div></div>
<div>
<table border="0" cellspacing="0" bgcolor="#FFFFFF">
<tbody>
<tr>
<td valign="top"><strong><span>AC voltage measurement</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>Accuracies</span></td>
</tr>
<tr>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
<td valign="top"><span>± 1% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>1 m V</span></td>
<td valign="top"><span>± 1% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
<td valign="top"><span>± 1% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
<td valign="top"><span>± 1% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>750V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 1% + 5 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>DC</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>Accuracies</span></td>
</tr>
<tr>
<td valign="top"><span>400 mV</span></td>
<td valign="top"><span>0.1 mV</span></td>
<td valign="top"><span>± 0.5% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4V</span></td>
<td valign="top"><span>1 mV</span></td>
<td valign="top"><span>± 0.5% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>40V</span></td>
<td valign="top"><span>10 mV</span></td>
<td valign="top"><span>± 0.5% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>400V</span></td>
<td valign="top"><span>100 mV</span></td>
<td valign="top"><span>± 0.5% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>750V</span></td>
<td valign="top"><span>1V</span></td>
<td valign="top"><span>± 0.5% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Resistance</span></strong></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td valign="top"><span>Resolution</span></td>
<td valign="top"><span>Accuracies</span></td>
</tr>
<tr>
<td valign="top"><span>400 Ω</span></td>
<td valign="top"><span>0.1 Ω</span></td>
<td valign="top"><span>± 1.2% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4 kΩ</span></td>
<td valign="top"><span>1 Ω</span></td>
<td valign="top"><span>± 1.2% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>40 kΩ</span></td>
<td valign="top"><span>10 Ω</span></td>
<td valign="top"><span>± 1.2% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>400 kΩ</span></td>
<td valign="top"><span>100 Ω</span></td>
<td valign="top"><span>± 1.2% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>4 MΩ</span></td>
<td valign="top"><span>1 kΩ</span></td>
<td valign="top"><span>± 1.2% + 3 Dgt</span></td>
</tr>
<tr>
<td valign="top"><span>40 MΩ</span></td>
<td valign="top"><span>10 kΩ</span></td>
<td valign="top"><span>± 2.0% + 4 Dgt</span></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Input impedance</span></td>
<td colspan="2" valign="top"><span>10 MΩ</span></td>
</tr>
<tr>
<td valign="top"><span>Overvoltage protection</span></td>
<td colspan="2" valign="top"><span>500V DC</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><strong><span>Continuity test</span></strong></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Measuring range</span></td>
<td colspan="2" valign="top"><span>Beep</span></td>
</tr>
<tr>
<td valign="top"><span>400 Ω</span></td>
<td colspan="2" valign="top"><span>&gt; 25 Ω</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Line detection</span></td>
<td colspan="2" valign="top"><span>By beep</span></td>
</tr>
<tr>
<td valign="top"><span>Beep switchable</span></td>
<td colspan="2" valign="top"><span>Slowly pulsating tone</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>Fast pulsating tone</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"></td>
</tr>
<tr>
<td valign="top"><span>Locating depth</span></td>
<td colspan="2" valign="top"><span>Max. 50 cm</span></td>
</tr>
<tr>
<td valign="top"><span>Connections</span></td>
<td colspan="2" valign="top"><span>RJ-11 plug, coconut clamps</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply receiver    </span></td>
<td colspan="2" valign="top"><span>9V block battery</span></td>
</tr>
<tr>
<td valign="top"><span>Power supply transmitter</span></td>
<td colspan="2" valign="top"><span>9V block battery (transmitter function)</span></td>
</tr>
<tr>
<td valign="top"></td>
<td colspan="2" valign="top"><span>2 x 1.5V AAA (voltmeter)</span></td>
</tr>
<tr>
<td valign="top"><span>Environmental conditions         </span></td>
<td colspan="2" valign="top"><span>0 &#8230; 50°C / 32 &#8230; 122°F, 5 &#8230; 95% rh</span></td>
</tr>
<tr>
<td valign="top"><span>Weight transmitter</span></td>
<td colspan="2" valign="top"><span>About 265 g / &lt; 1 lb</span></td>
</tr>
<tr>
<td valign="top"><span>Weight receiver</span></td>
<td colspan="2" valign="top"><span>About 89 g / &lt; 1 lb</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.amet.co.th/shop/cable-fault-meter/cable-fault-meter-pce-186-cb/">Cable Fault Meter PCE-186 CB</a> appeared first on <a href="https://www.amet.co.th">Amet Co.,Ltd</a>.</p>