– Automatic shutdown
– 2.8″ LC Display
– Built-in thermal imaging camera
– Heat measurement via IR or thermocouple
– Resistance measurement and continuity test
– Diode test and capacitance measurement
| Temperature measurement with thermal imaging camera | ||||
| Sampling rate | 3 times per second | |||
| Field of view (FOV) | 21° x 21°C / 0.5 m / 1 ft 7.6″ | |||
| Spatial resolution (IFOV) | 4.53 mrad | |||
| Resolution infrared camera | 80 x 80 Pixel | |||
| Thermal sensitivity / NETD | <0.1°C (0.18°F) at 30°C (86°F) / 100 mK | |||
| Frame rate | 50 Hz | |||
| Focal length | 7.5 mm | |||
| Sensor type | uncooled microbolometer | |||
| Spectral range | 8 … 14 µm | |||
| Measuring range object temperature | -20 … 260°C / -4 … 500°F | |||
| Measurement accuracy | ± 3°C / 5.4°F or 3% of the measured value, at 10 … 35°C / 50 … 95°F ambient temperature and > 0°C / 32°F object temperature | |||
| General Technical Data | ||||
| Display | Colour TFT, 6000 points with status display | |||
| Conversion | TRMS | |||
| Reference standards | IEC/EN61010-1, IEC/EN61326-1 | |||
| Isolation | Double | |||
| Pollution degree | 2 | |||
| Overload category | CAT IV 600 V, CAT III 1000 V | |||
| Battery type | 1 x 7.4V Li-Ion battery, 2300-mAh | |||
| Power supply charger | 100 / 240V AC, 50/60 Hz, 10V DC, 1 A | |||
| Battery level indicator | Yes | |||
| Automatic shutdown | After 15, 30 or 60 minutes of inactivity (deactivatable) | |||
| Fuses | F10A/1000V, 10 x 38 mm (Input 10 A) F800mA/1000V, 6 x 32 mm (Input mA, µA) |
|||
| Test temperature | 18 … 28°C / 64 … 82°F | |||
| Operating conditions | 5 … 40°C / 41 … 104°F, <80% r.H. | |||
| Storage conditions | -20 … 60°C / -4 … 140°F, <80% r.H. | |||
| Maximum operating height | 2000 m / 2187 yd | |||
| Dimensions | 175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in | |||
| Weight | 540 g / 1 lb 3oz | |||
| Technical Data DC Voltage | ||||
| Measuring range | Resolution | Measurement accuracy | Input resistance | Overload protection |
| 600 mV | 0.1 mV | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 6V | 0.001V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 60V | 0.01V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 600V | 0.1V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 1000V | 1V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
| Technical Data AC Voltage (TRMS) | ||||
| Measuring range | Resolution | Measurement accuracy (50 … 60 Hz) |
Measurement accuracy (61 Hz … 1 kHz) |
Overload protection |
| 6V | 0.001V | ± (0.8% of measurement value +5 Dgt)± | (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| 60V | 0.01V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| 600V | 0.1V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| 1000V | 1V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| Technical Data DC and AC voltage (TRMS) | ||||
| Measuring range | Resolution | Measurement accuracy | Input resistance | Overload protection |
| 6V | 0.001V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 60V | 0.01V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 600V | 0.1V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ | 1000V DC / ACrms |
| 1000V | 1V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ | 1000V DC / ACrms |
| Technical Data Direct Current | ||||
| Measuring range | Resolution | Measurement accuracy | Overload protection | |
| 600 µA | 0.1µA | ± (0.9% of measurement value +5 Dgt) | Protection 800-mA / 1000 V | |
| 6000 µA | 1 µA | ± (0.9% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 60-mA | 0.01-mA | ± (0.9% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 600-mA | 0.1-mA | ± (0.9% of measurement value +8 Dgt) | Protection 800-mA / 1000V | |
| 10 A | 0.01 A | ± (1.5% of measurement value +5 Dgt) | Protection 10 A / 1000V | |
| Technical Data Alternating Current (TRMS) | ||||
| Measuring range | Resolution | Measurement accuracy | Overload protection | |
| 600 µA | 0.1 µA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 6000 µA | 1 µA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 60-mA | 0.01-mA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 600-mA | 0.1-mA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V | |
| 10 A | 0.01 A | ± (1.5% of measurement value +5 Dgt) | Protection 10 A / 1000V | |
| Technical Data Coil Current | ||||
| Measuring range | Resolution | Measurement accuracy (50 … 60 Hz) |
Measurement accuracy (61 Hz … 1 kHz) | Overload protection |
| 30 A | 0.01 A | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| 300 A | 0.1 A | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| 3000 A | 1 A | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
| Technical Data Diode Test | ||||
| Test current | <1.5-mA | |||
| Maximum voltage at the open circuit | 3.3V DC | |||
| Resistance and continuity test | ||||
| Measuring range | Resolution | Measurement accuracy | Acoustic warning sound | Overload protection |
| 600 Ω | 0.1Ω | ± (0.5% of measurement value +10 Dgt) | >50 Ω | 1000V DC / ACrms |
| 6 Ω | 0.001 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
| 60 kΩ | 0.01 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
| 600 kΩ | 0.1 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
| 6 MΩ | 0.001 MΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
| 60 MΩ | 0.01 MΩ | ± (2.5% of measurement value +10 Dgt) | >50 Ω | 1000V DC / ACrms |
| Technical Data Frequency | ||||
| Measuring range | Resolution | Measurement accuracy | Overload protection | |
| 40 Hz … 10 kHz | 0.01 Hz … 0.001 kHz | ± (0.5% of measurement value) | 1000V DC / ACrms | |
| 60 Hz | 0.01 Hz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 600 Hz | 0.1 Hz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 6 kHz | 0.001kHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 60 kHz | 0.01kHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 600 kHz | 0.1 kHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 6 MHz | 0.001 MHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| 10 MHz | 0.01 MHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms | |
| Technical Data Duty Cycle | ||||
| Measuring range | Resolution | Measurement accuracy | ||
| 5 … 95% | 0.1% | ± (1.2% of measurement value +2 Dgt) | ||
| Technical Data Capacitance | ||||
| Measuring range | Resolution | Measurement accuracy | Overload protection | |
| 60 nF | 0.01 nF | ± (1.5% of measurement value +20 Dgt) | 1000V DC / ACrms | |
| 600 nF | 0.1 nF | ± (1.2% of measurement value +8 Dgt) | 1000V DC / ACrms | |
| 6 µF | 0.001 µF | ± (1.5% of measurement value +8 Dgt) | 1000V DC / ACrms | |
| 60 µF | 0.01 µF | ± (1.2% of measurement value +8 Dgt) | 1000V DC / ACrms | |
| 600 µF | 0.1 µF | ± (1.5% of measurement value +8 Dgt) | 1000V DC / ACrms | |
| 6000 µF | 1 µF | ± (2.5% of measurement value +20 Dgt) | 1000V DC / ACrms | |
| Technical Data Temperature (Thermoelement Type K) | ||||
| Measuring range | Resolution | Measurement accuracy | Overload protection | |
| -40 … 600°C / -40 … 1112°F | 0.1°C / 0.18°F | ± (1.5% of measurement value 3°C / 5.4°F) | 1000V DC / ACrms | |
| 600 … 1000°C / 1112°F … 1832°F | 1°C / 1.8°F | ± (1.5% of measurement value 3°C / 5.4°F) | 1000V DC / ACrms | |
| PCE-HDM 20 | ||||











รีวิว
ยังไม่มีบทวิจารณ์