| Inside | ||
| Measuring function | ||
| Air temperature | ||
| Measuring range | Resolution | Accuracy |
| 0 … +50 °C | 0.1 | – |
| 32 … 122 °F | ||
| Measuring function | ||
| Rel. Humidity | ||
| Measuring range | Resolution | Accuracy |
| 1 … 99 % | 1 % | – |
| Measuring function | ||
| Air Pressure | ||
| Measuring function | Resolution | Accuracy |
| 300 … 1100 hPa | 0.1 hPa | ± 3 hPa |
| 8.85 … 32.5 inHg | 0.01 inHg | |
| Measuring interval: 48 seconds | ||
| Alarm time: 120 seconds | ||
| Outside | ||
| Measuring function | ||
| Air temperature | ||
| Measuring range | Resolution | Accuracy |
| -40 … 60 °C | 0.1 | ±1 °C |
| -40 … 140 °F | ||
| Measuring function | ||
| Rel. Humidity | ||
| Measuring range | Resolution | Accuracy |
| 1 … 99 % | 1 % | ±4 % within 20 … 80 % |
| ±6 % within 20 … 80 % | ||
| Measuring function | ||
| Rainfall | ||
| Measuring range | Resolution | Accuracy |
| 0 … 9999 mm | 0.3 mm at <1000 mm | ±6 % |
| 1 mm at >1000 mm | ||
| Measuring function | ||
| Wind speed | ||
| Measuring range | Resolution | Accuracy |
| 0 … 50 m/s | 0.1 | ±1 m/s at <5 m/s |
| 0 … 100 mph | ±10 % at >5 m/s | |
| Reception range 100 m, 300 feet | ||
| Frequency: 868 MHz (Europe) | ||
| Measuring interval: 48 seconds | ||
| Protection class: IP X3 | ||
| Other specifications | ||
| 7 inch touchscreen | ||
| Backlit illuminated display | ||
| Setting the time | manual and automatic (DCF 77) | |
| Power supply display | 3 x 1.5 V AA | |
| Power supply outdoor module | 2 x 1.5 V AA | |
| Dimensions display | 230 x 150 mm | |
| Dimensions outdoor module | 400 x 117 mm | |
| Weight display | ca. 551 g | |
| Weight outdoor module | ca. 545 g | |
| Display | ||
| – Indoor temperature in Celsius or Fahrenheit | ||
| – Outside temperature in Celsius or Fahrenheit | ||
| – Indoor humidity | ||
| – Outdoor humidity | ||
| – Air pressure gauge in inHg or hPa | ||
| – Absolute or relative air pressure display selectable | ||
| – Precipitation indication in mm or inch | ||
| – Rain gauge 1 hour, 24 hours, 1 week, 1 month, since the last reset | ||
| – Dew point temperature display | ||
| – Weather forecast | ||
| – Weather forecast trend display | ||
| – Storm warning | ||
| – Display of weather data | ||
| – Programmable alarms for different weather conditions | ||
| – Storage of the minimum and maximum values of the received weather data | ||
| – Wind speed in mph, km/h, m/s, knots or Beaufort selectable | ||
| – Wind direction indicator | ||
| – Wind chill temperature display (sensed temperature) | ||
| – LED backlight | ||
| – Battery life of the weather station about 1 to 2 years | ||
| – Radio clock | ||
| – 12 or 24 hours display | ||
| – Calendar | ||
| – Time zone adjustable | ||
| – Power saving function | ||
| – The weather station display can be used as a wall model or stand model | ||
| – Permanent adjustment of weather data and radio clock signal | ||
| – Ring memory for 4080 complete weather records | ||
| (adjustable storage interval 5 to 240 min) | ||
| Adjustable alarm functions on the weather station | ||
| – Humidity inside max. alarm | ||
| – Temperature inside max. alarm | ||
| – Humidity outside max. alarm | ||
| – Temperature outside max. alarm | ||
| – Wind chill max. alarm | ||
| – Dew point max. alarm | ||
| – Air pressure max. alarm | ||
| – Wind speed max. alarm | ||
| – Wind gust speed max. alarm | ||
| – 1 hour of precipitation max. alarm | ||
| – 24 hrs precipitation max. alarm | ||
| – Humidity inside min. alarm | ||
| – Temperature inside min. alarm | ||
| – Humidity outside min. alarm | ||
| – Temperature outside min. alarm | ||
| – Wind chill min. alarm of the weather station | ||
| – Dew point min. alarm | ||
| – Air pressure min. alarm | ||
| Storable measured values via the weather station (with time / date) | ||
| – 1 hour of precipitation max. | ||
| – 24 hours of precipitation max. | ||
| – Week precipitation max. | ||
| – Month precipitation max. | ||
| – Humidity inside min. | ||
| – Temperature inside min. | ||
| – Humidity of the weather station outside min. | ||
| – Temperature outside min. | ||
| – Wind chill temperature min. | ||
| – Dew point temperatur min. | ||
| – Weather station air pressure min. | ||
| – Humidity inside max. | ||
| – Temperature inside max. | ||
| – Humidity of the weather station outside max. | ||
| – Temperature of the weather station outside max. | ||
| – Wind chill temperature max. | ||
| – Dew point temperature max. | ||
| – Air pressure max. | ||
| – Wind speed max. | ||
| – Wind direction | ||
| – Gusts of wind speed max. | ||
Relative Humidity Meter Station PCE-FWS 20N-1
PCE-FWS 20N-1
Availability : กรุณาติดต่อสอบถาม
เฉพาะลูกค้าที่เข้าสู่ระบบ และเคยซื้อสินค้าชิ้นนี้แล้วเท่านั้น ที่เขียนบทวิจารณ์ได้
สินค้าที่เกี่ยวข้อง
Relative Humidity Meter
Relative Humidity Meter PCE-CMM 8-ICA incl. ISO Calibration Certificate
PCE-CMM 8-ICA
Relative Humidity Meter
Multifunction Relative Humidity Meter PCE-HGP-ICA incl. ISO Calibration Cert.
PCE-HGP-ICA
Relative Humidity Meter
PCE-THB 40
Relative Humidity Meter
PCE-HT 112
Relative Humidity Meter
Relative Humidity Meter PCE-HT 112-ICA Incl. ISO Calibration Certificate
PCE-HT 112-ICA
Relative Humidity Meter
Relative Humidity Meter PCE-HT 114-ICA Incl. ISO Calibration Certificate
PCE-HT 114-ICA
Relative Humidity Meter
PCE-MA 110
Relative Humidity Meter
Relative Humidity Meter PCE-CMM 10-ICA incl. ISO Calibration Certificate
PCE-CMM 10-ICA











รีวิว