Ultrasonic flow meter PCE-TDS 100HSH+ incl. Temperature data logger
according to the transit time difference method / For determining flow velocity and flow / Measurement method for liquids that are as homogeneous as possible
Calculation of flow velocity according to the transit-time principle follows the equation:
![]()
v = measured velocity
T1 = run time of the ultrasonic signal in the flow direction
T2 = run time of the ultrasonic signal against the flow direction
L = length of the ultrasonic wave
α = ultrasonic signal angle to the flow
The transit-time principle requires pipes to be full and have no bubbles and no particles.
Each PCE-TDS series meter is assembled by PCE Instruments in Germany and and factory-calibrated (without any documentation). The reference display of the in-house test stand used by PCE for calibration has a valid DAkkS calibration certificate. This ensures traceability to the Physikalisch-Technische Bundesanstalt (PTB) German national standard. Please note that the meter’s measured values depend on the pipe geometry, material and coating; the medium type, temperature and speed; and the sensor type and measuring method.
– ideal for retrofitting
– installation without process interruption
– easy assembly
– accurate and reliable
– no pressure loss
– maintenance-free, no moving parts
– wear-free
– portable devices for control measurements
| Technical Data Ultrasonic Flow Meter PCE-TDS 100 | |
| Handheld measuring range | -32 … +32 m/s |
| Resolution | 0.0001 m/s |
| Accuracy for DN ≥ 50 mm: for DN < 50 mm: | ±1.5 % of measured value ±3.5 % of measured value |
| Reproducibility | ±1.0 % of measured value |
| Media | All liquids with an impurity |
| <5% and a flow >0.03 m³/h | |
| Flow units | Cubic meter [m³] |
| Liter [l] | |
| Gallon (USA) [gal] | |
| Imperial gallon (UK) [igl] | |
| Million USA gallon [mgl] | |
| Cubic foot [cf] | |
| Barrel (USA) [bal] | |
| Imperial barrel (UK) [ib] | |
| Oil barrel [ob] | |
| Time settings | per day [/d] |
| per hour [/h] | |
| per minute [/m] | |
| and per second [/s] | |
| Data logger | 1800 measurements |
| Interface | USB (for online measurement and reading of the internal memory) |
| Protection | IP 52 |
| Power supply | 3 x AA NiMH rechargeable battery / 2100 mAh |
| (at full charge 12h running time) 100 … 240 V AC 50/60 Hz | |
| Dimensions | 214 x 104 x 40 mm / 8.4 x 4.1 x 1.5″ |
| Weight | 450 g / 15 oz |
| Sensor | nominal width DN 15 … 100, 20 … 108 mm / approx. 3/4 … 4″ nominal width DN 50 … 700, 57 … 720 mm / approx. 2 … 28″ |
| Temperature of liquid | -30 … 160 °C / -22 … 320 °F |
| Dimensions | 50 x 45 x 45 mm / 1.9 x 1.7 x 1.7″ |
| Weight | 260 g / 9oz |
| Technical data evaluation software | |
| – Units of power W, kW, MW, J/h, kJ/h, MJ/h, Btu/h, kBtu/h, MBtu/h | |
| – Units of energy J, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu | |
| – Graphical representation of flow, flow temperature, | |
| return temperature, heat output and heat quantity | |
| – Tabular representation of flow, flow temperature, | |
| return temperature, heat output and heat quantity | |
| – Mobile and stationary measurement mode | |
| – Real-time data logger with unlimited runtime (only limited by PC memory capacity) | |
| – Data export function | |
| – User-guided software operation with step-by-step instructions for | |
| device and software configuration | |
| Technical Data Temperature Datalogger PCE-T 330 | |
| Measuring range thermocouple Type K � | -200 … +1370 °C / -328 … 2498 °F |
| Resolution | 0.01 °C |
| Accuracy* | ±(0.3 % of rdg. +0.40) °C* |
| Measuring range thermocouple Type T | –200 … +400 °C / -328 … 752 °F |
| Resolution | 00.01 °C |
| Accuracy* | ±±(0.3 % of rdg. +0.40) °C* |
| Measuring range thermocouple Type J | –200 … +1200 °C / -328 … 2192 °F |
| Resolution | 00.01 °C |
| Accuracy* | ±±(0.3 % of rdg. +0.40) °C* |
| Measuring rate | 2/s |
| Operating temperature | -10 … +50 °C / 14 … 122 °F |
| Storage temperature | -20 … +60 °C (without batteries) / -4 … 140 °F |
| Power supply | 3 x AAA batteries / 1.2 V battery |
| Battery life | ca. 190 h |
| (without backlight, battery capacity 1200 mAh, | |
| ambient temperature 25 °C) | |
| Protection class | IP52 (with protective cover and connected sensor) |
| Norm/ certification | CE/EMC ROHS |