Specifications: Fluke 721Ex Precision Pressure Calibrator
| Specifications 1-Year | |||
| Fluke-721Ex-1601 | Low pressure sensor | ||
| Range | Resolution | Accuracy | |
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +100 psi, -0.83 bar to 6.9 bar | 0.01 psi, 0.0001 bar | 0.025% of full scale | |
| Fluke-721Ex-1603 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +300 psi, -0.83 bar to 20 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-1605 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +500 psi, -0.83 bar to 34.5 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-1610 | Low pressure sensor | ||
| 0 psi to +1000 psi, 0.00 bar to 69 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +500 psi, -0.83 bar to 34.5 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-1615 | Low pressure sensor | ||
| Range | Resolution | Accuracy | |
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-1630 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721Ex-1650 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar | 0.1 psi, 0.01 bar | 0.035% of full scale | |
| Fluke-721Ex-3601 | Low pressure sensor | ||
| Range | Resolution | Accuracy | |
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 to +100 psi, -0.83 bar to 6.9 bar | .01 psi, 0.0001 bar | 0.025% of full scale | |
| Fluke-721Ex-3603 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +300 psi, -0.83 bar to 20 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-3605 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +500 psi, -0.83 bar to 34.5 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-3610 | Low pressure sensor | ||
| Range | Resolution | Accuracy | |
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1000 psi, 0.00 bar to 69 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721Ex-3615 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721Ex-3630 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721Ex-3650 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar | 0.1 psi, 0.01 bar | 0.035% of full scale | |
| General Specifications | |||
| Instrument setup recall | Last used on power-up | ||
| Environmental | Operating temperature -10°C to +45°C Storage temperature (without batteries) -20°C to +60°C | ||
| Altitude | 2,000 m | ||
| Ingress protection | IP-40 | ||
| Power requirements | 6.0 V DC | ||
| Battery life | >35 hours, typical usage | ||
| Batteries required | (4) Standard AA cells | ||
| Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) | ||
| Weight | 03539 kg (1 lb 3 oz) | ||
| Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe | ||
| Electrical and Temperature Measurement 1-Year | |||
| Function | Range | Resolution | Accuracy |
| mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
| Temperature Effect | |||
| No effect on accuracy on all functions from 15°C to 35°C | |||
| Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | |||
| Available Pressure Engineering Units | |||
| psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F | |||
| Available Pressure Engineering Units | |||
| ATEX | Ex ia IIB T3 Gb (Ta= -10… +45 °C) | ||
| KEMA 10 ATEX 0168X | |||
| IECEx | Ex ia IIB T3 Gb (Ta= -10…+45 °C) | ||
| II 2 G IECEx CSA 10.0013X | |||