Laser temperature meter for easy measurement of surface temperatures /
Fast response time / Adjustable emissivity / Max-Min function / Alarm function / Measuring range up to 1200 °C / 2192 °F / Thermocouples type K connectable / Software for PC connection
The pyrometer PCE-893-ICA is suitable for simple temperature measurements. The emissivity of the surface can be adjusted on the PCE-893-ICA thermometer. Thus, the thermometer PCE-893-ICA is suitable for almost all surfaces. The dual laser of the thermometer PCE-893-ICA marks the exact center of the measurement spot. This helps the user considerably with non-contact temperature measurement. The thermometer PCE-893-ICA has a backlit display. In addition to the emissivity setting, the user can set limit value alarms over the entire measuring range of the PCE-893-ICA thermometer. The measuring range is from -50 °C to + 1200 °C / -58 … 2192 °F. The measuring spot ratio of the thermometer PCE-893-ICA is 50:1.
In addition to the infrared measurement, a variety of thermocouples Type-K can be connected to the thermometer. Here measurements up to 1370 °C / 2498 °F are possible. The included software and the USB port on the thermometer allow the operator to analyze and store all measurement data on the PC both graphically and in a table.
***ATTENTION*** Our temperature sensors are designed for industrial and laboratory surface temperature measurement ONLY. They are not designed or certified for body temperature measurement or for medical use.
Infrared measurement | |
Infrared measurement | -50 … 1200 °C / -58 … 2192 °F |
Resolution | 0.1 at display <1000 |
1 at display >1000 | |
Accuracy | ±3 °C / 5.4 °F (-50 … 20 °C / -58 … 68 °F) |
±1 % ±1 °C / ±1.8°F (20 … 500 °C / 68 … 932°F) | |
±1.5 % (500 … 1000 °C / 932 … 1832 °F) | |
±2 % (1000 … 1600 °C / 1832 … 2912 °F) | |
The accuracies apply at an ambient temperature of 23 … 25 °C (73 … 77 °F) | |
Repeatability | ±1.5 °C / 2.7 °F (-50 … 20 °C / -58 … 68 °F) |
±0.5 % or ±0.5 °C / 0.9 °F | |
(20 … 1000 °C / 68 … 1832 °F) | |
±1.0 % (1000 … 1600 °C / 1832 … 2912 °F) | |
Thermoelement | |
Measuring range | -50 … 1370 °C / -58 … 2498 °F |
Resolution | 0.1 at display <1000 |
1 at display >1000 | |
Accuracy | ±2.5 °C / ±3.6°F (-50 … 0 °C / -58 … 32°F) |
±0.5 % ±1.5 °C / 3 °F | |
(0 … 1370 °C / 32 … 2498 °F) | |
Measurement spot ratio | 50:1 |
Response time | 150 ms |
Spectral range | 8 … 14 µm |
Emissivity | Adjustable 0.10 … 1.0 |
Display overrange | The display will show “—-“ |
Display laser diode | LCD with backlight |
Output | <1 mW |
Wavelength | 630 … 670 nm |
Classification | Class 2 |
Power supply | 9 V block battery |
Operating conditions | 0 … +50 °C / 32 … 122 °F |
Storage conditions | -10 … +60 °C / 14 … 140 °F |
Weight | ca. 282 g without battery |
Dimensions | 200 x 55 x 150 mm / 7.8 x 2.1 x 5.9″ |
รีวิว