Specifications: Fluke 289 IMSK Industrial Multimeter Service Kit
| Specifications for 289 | ||
| Function | ||
| DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.025% | |
| AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.4% (True-RMS) | |
| DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.05% | |
| AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.6% (True-RMS) | |
| Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
| Basic accuracy | 1.0% | |
| Resistance | Range / resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| Basic accuracy | 0.05% | |
| Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
| Basic accuracy | 1.0% | |
| Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| Basic accuracy | 0.005% | |
| Connectivity | Optional infrared connector via Fluke ir3000 FC | |
| General Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Battery type | 6 AA alkaline batteries, NEDA 15A IECLR6 | |
| Battery life | 100 hours minimum, 200 hours in logging mode | |
| Temperature | Operating | -20°C to 55°C |
| Storage | -40°C to 60°C | |
| Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
| Electromagnetic compatibility | EMC EN61326–1 | |
| Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
| Shock | 1-meter drop per IEC/EN 61010–1 3rd Edition | |
| Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
| Weight | 870.9 g (28 oz) | |
| Multiple on screen displays | Yes | |
| True-RMS AC bandwidth | 100 kHz | |
| dBV/dBm | Yes | |
| DC mV resolution | 1 μV | |
| Megohm range | Up to 500 MΩ | |
| Conductance | 50.00 nS | |
| Continuity beeper | Yes | |
| Battery/fuse access | Yes/Yes | |
| Elapse time clock | Yes | |
| Time of day clock | Yes | |
| Min-max-avg | Yes | |
| Duty cycle | Yes | |
| Pulse width | Yes | |
| Isolated optical interface | Yes | |
| Auto/touch hold | Yes | |
| Reading memory | Yes | |
| Log to PC | Yes | |
| Interval/event logging | Yes | |
| Logging memory | Up to 15,000 readings | |
| Wireless connectivity (optional) | ||
| Specifications: Fluke i400 AC Current Clamp | |
| Nominal current range | 400 A |
| Continuous current range | 1 A – 400 A |
| Maximum non-destructive current | 1000 A |
| Lowest measurable current | 1 A |
| Basic accuracy | 2% + 0.06 A |
| (45-400 Hz) | |
| (% reading + floorspec) | |
| Useable frequency | 5 Hz – 20 kHz |
| Output level(s) | 1 mA/A |
| Safety Specifications | |
| Safety | CAT IV 600 V, CAT III, 1000 V |
| Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
| Mechanical and General Specifications | |
| Warranty | 1 year |
| Maximum conductor diameter | 32 mm (1.25 in) |
| Maximum conductor size (busbar) | 750 MCM |
| Output cable length | 1.5 m (59 in) |
| Shrouded banana plugs | Yes |