Specifications: Fluke 721 Pressure Calibration Instruments
| Specifications 1-Year | |||
| Fluke-721-1601 | Range | Resolution | Accuracy |
| Low pressure sensor | |||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +100 psi, -0.83 bar to 6.9 bar | 0.01 psi, 0.0001 bar | 0.025% of full scale | |
| Fluke-721-1603 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +300 psi, -0.83 bar to 20 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-1605 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +500 psi, -0.83 bar to 34.5 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-1610 | Low pressure sensor | ||
| -14 psi to +16psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1000 psi, 0.00 bar to 69 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-1615 | Range | Resolution | Accuracy |
| Low pressure sensor | |||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-1630 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721-1650 | Low pressure sensor | ||
| -14 psi to +16 psi, -0.97 bar to 1.1 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar | 0.1 psi, 0.01 bar | 0.035% of full scale | |
| Fluke-721-3601 | Range | Resolution | Accuracy |
| Low pressure sensor | |||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 to +100 psi, -0.83 bar to 6.9 bar | .01 psi, 0.0001 bar | 0.025% of full scale | |
| Fluke-721-3603 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +300 psi, -0.83 bar to 20 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-3605 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| -12 psi to +500 psi, -0.83 bar to 34.5 bar | 0.01 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-3610 | Range | Resolution | Accuracy |
| Low pressure sensor | |||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1000 psi, 0.00 bar to 69 bar | 0.1 psi, 0.001 bar | 0.025% of full scale | |
| Fluke-721-3615 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +1500 psi, 0.00 bar to 103.4 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721-3630 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +3000 psi, 0.00 bar to 200 bar | 0.1 psi, 0.01 bar | 0.025% of full scale | |
| Fluke-721-3650 | Low pressure sensor | ||
| -14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
| High pressure sensor | |||
| 0 psi to +5000 psi, 0.00 bar to 345 bar | 0.1 psi, 0.01 bar | 0.035% of full scale | |
| General Specifications | |||
| Instrument setup recall | Last used on power-up | ||
| Environmental | Operating temperature -10°C to +50°C Storage temperature (without batteries) -20°C to +60°C | ||
| Altitude | 2,000 m | ||
| Ingress protection | IP-40 | ||
| Power requirements | 6.0 V DC | ||
| Battery life | >35 hours, typical usage | ||
| Batteries required | (4) Standard AA cells | ||
| Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) | ||
| Weight | 03539 kg (1 lb 3 oz) | ||
| Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe | ||
| Electrical and Temperature Measurement 1-Year | |||
| Function | Range | Resolution | Accuracy |
| mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
| V DC measure | 0 to 30 V DC | 0.001 V | ±0.015% of rdg ±0.002 V |
| Temperature measure (RTD/ Ohms)1 | -40°C to 150°C (-40°F to 302°F) | 0.01°C, 0.01°F | ±0.015% of rdg ±0.02 ohms ±0.1°C (±0.2°F) ±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe accessory |
| Loop power supply | 24 V | N/A | 24 mA @ 24 V |
| 1. Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory | |||
| Temperature Effect | |||
| No effect on accuracy on all functions from 15°C to 35°C | |||
| Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | |||
| Available Pressure Engineering Units | |||
| psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F | |||